Loading...
HomeMy WebLinkAboutMFP20004847.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20004847 IVR Number: 20004847 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:10/17/2020Application Date:3342101265Parcel Number: 923 N 31ST ST Permit Type:11/03/2020Issue Date:Franchise Permit Work Class:11/03/2021Expiration Date:Minor Utility Job Number: 168351Franchise Type:Cable Description: Comcast to bore 128' in ROW and place 2" PVC. Begin at pole SE corner of 910's property. Bore 2' then bore 72' under driveway. Bore 21' then bore 23 under road and continue boring 10' to private property. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Fahm Saelee Prince Telecom Applicant Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Akisha Brown Prince Telecom Inc 551A Mews Dr New Castle, DE 19720 B: (302) 482-8893 C: (302) 482-8892 Contractor Business License Number: 29850Electrical Contractor: PRINCTL834BF Construction Contractor: PRINCTL862PS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP20004847 Scott Warlick 10/21/2020 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS MFP20004847 Scott Warlick CED 10/21/2020 CSG 168351 0 923 N 31st St Renton Permitting Requesting to bore 128' in r/w and place 2" PVC. Begin at pole SE corner of 910's property bore 2' then bore 72' under driveway with potential cuts, bore 21', then bore 23' under road and continue boring 10' to private property. Date: ENGINEERED FOR:0 0 Comcast ESS DatePrepared By:0 Rev 27116 27117 27120 POLE 2' ROW BORE 72' DWB 21' ROW BORE 23' ROAD BORE 10' ROW BORE POTENTIAL CUTPOTENTIAL CUT POTENTIAL MFP20004847 W W W W W W W W W W W W W W W W W W W W W W W W W W W W City Storm line requires a minimum of 5' horizontal separation and 10' from water main.Recommend crossing the street here or hugging the back of the ROW line in order to meet separations City Sewer main POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS <21'><23'>N 31st St KENNY"S TRAFFIC ZONE PLANS Kenny StertzLongview , Watraficplayr@aol.comTCS # 5663 NORTH NOT TO SCALE cones - flagger -ROADWORKAHEADW20-1W20-7aW20-4100'ABC100'100'ONE LANEROADAHEADPrince telecom telecommunicationsinstallation Fahm Salee 253-891-2899 JOB # CSG168351 916910 923 920 <10'><72'><2'>ROAD WORKAHEAD W20-1W20-7bABBE PREPAREDTO STOP100'100'W20-7a C 100'ROADWORKAHEADW20-1W20-7bABBE PREPAREDTO STOP100'100'Burnett Ave NROADWORKAHEADW20-1 W20-4 100' A B 100'ONE LANEROADAHEADRoad borepotential cut - Pole - SIGN SPACING = X (FEET) (1) FREEWAYS & EXPRESSWAYS RURAL HIGHWAYS RURAL ROADS RURAL ROADS and URBAN ARTERIALS RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED 55/70 mph 60/65 mph 45/55 mph 35/40 mph 25/30 mph 25mph or less 1500ft +/- 800ft +/- 500ft +/- 350ft +/- 200ft +/-(2) 100ft +/-(2) (1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED 10ft LANE 11ft LANE 12ft LANE L L L1/2L 1/2L 1/2L Lanewidth MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting SHOULDER TAPERS(assume 10ft shoulders) 1/3L Devices(FT)LengthMPH 2025303540455055606570 70105150205270450500550600650700 668810161415161719 355575105135225250275300325350 345569889910 75115165225295495550605660715770 679911181516181920 406085115150250285305330370385 3455698991011 80125180245320540600660720780840 6710912191618192122 406590125160270300330360390420 345561099101112 2025303540455055606570 2535507090150170185200220235 33344666677 Shoulder tapers equalsshoulder Width x Speed/3 MINIMUM TAPER LENGTH = L (feet) POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70 LANEWIDTH(feet) 101112 105115125 150165180 205225245 270 295320 450 495540 500 550600 550605660 660720 -----780 840 TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS) STATIONARYOPERATION(ft) 30 MIN. 100 max. MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION 4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE LONGITUDINAL BUFFER SPACE = B ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION BUFFER DATALONGITUDINAL BUFFER SPACE = B SPEED (mph)LENGTH (ft)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 CHANNELIZING DEVICE SPACING CHART (FEET) 50/70 35/45 20/30 mph *Half-Spacing*TAPER TANGENT 20 N/A 40 30 20 80 60 40N/A www.invarion.com MFP20004847