HomeMy WebLinkAboutMFP20004847.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP20004847
IVR Number: 20004847
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:10/17/2020Application Date:3342101265Parcel Number: 923 N 31ST ST
Permit Type:11/03/2020Issue Date:Franchise
Permit Work Class:11/03/2021Expiration Date:Minor Utility
Job Number: 168351Franchise Type:Cable
Description: Comcast to bore 128' in ROW and place 2" PVC. Begin at pole SE corner of 910's property. Bore 2' then bore 72'
under driveway. Bore 21' then bore 23 under road and continue boring 10' to private property. Pothole all existing
utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Fahm Saelee
Prince Telecom
Applicant
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP20004847
Scott Warlick 10/21/2020
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
MFP20004847
Scott Warlick CED 10/21/2020
CSG 168351 0 923 N 31st St Renton Permitting
Requesting to bore 128' in r/w and place 2" PVC. Begin at pole SE corner of 910's
property bore 2' then bore 72' under driveway with potential cuts, bore 21', then bore
23' under road and continue boring 10' to private property.
Date:
ENGINEERED FOR:0
0
Comcast ESS
DatePrepared By:0 Rev
27116
27117 27120
POLE
2' ROW BORE
72' DWB
21' ROW BORE
23' ROAD BORE
10' ROW BORE
POTENTIAL CUTPOTENTIAL CUT
POTENTIAL
MFP20004847
W W W W W W W W W W W W W W W W W W W W W W W W W W W W
City Storm line
requires a minimum of
5' horizontal
separation and 10'
from water main.Recommend crossing
the street here or
hugging the back of
the ROW line in order
to meet separations
City Sewer main
POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS
<21'><23'>N 31st St
KENNY"S TRAFFIC ZONE PLANS
Kenny StertzLongview , Watraficplayr@aol.comTCS # 5663
NORTH
NOT TO SCALE
cones -
flagger -ROADWORKAHEADW20-1W20-7aW20-4100'ABC100'100'ONE LANEROADAHEADPrince telecom
telecommunicationsinstallation
Fahm Salee
253-891-2899
JOB # CSG168351
916910
923
920
<10'><72'><2'>ROAD
WORKAHEAD W20-1W20-7bABBE PREPAREDTO STOP100'100'W20-7a
C
100'ROADWORKAHEADW20-1W20-7bABBE PREPAREDTO STOP100'100'Burnett Ave NROADWORKAHEADW20-1 W20-4
100'
A B
100'ONE LANEROADAHEADRoad borepotential cut -
Pole -
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L Devices(FT)LengthMPH
2025303540455055606570
70105150205270450500550600650700
668810161415161719
355575105135225250275300325350
345569889910
75115165225295495550605660715770
679911181516181920
406085115150250285305330370385
3455698991011
80125180245320540600660720780840
6710912191618192122
406590125160270300330360390420
345561099101112
2025303540455055606570
2535507090150170185200220235
33344666677
Shoulder tapers equalsshoulder Width x Speed/3
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70
LANEWIDTH(feet)
101112
105115125
150165180
205225245
270
295320
450
495540
500
550600
550605660 660720
-----780 840
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
BUFFER DATALONGITUDINAL BUFFER SPACE = B
SPEED (mph)LENGTH (ft)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
www.invarion.com
MFP20004847