HomeMy WebLinkAboutP_Preliminary_Civil_Plan_Set_&_Landscape_Plan_10302020_v1RHRHRHRHRHRHMGMGMGMGMGMGMGLaLaLaLaLaLaEgEgEgEgEgEgEgEgEgAZAZLOT 1LOT 2N 24TH ST.MEADOW AVE. N.BOTANICAL NAMEFull and Matching, min. 8'-10' htFull and Matching, min. 8'-10' htFull and Matching, min. 8'-10' htFull and Matching, min. 8'-10' htFull and Matching, min. 8'-10' htCercidiphyllum japonicum* Street TreeAcer griseum*Amelanchier grandiflora 'Autumn Brilliance'*Prunus x yeodensis 'Yoshino'*Acer circinatum*KatsuraPaperbark MapleServiceberryFlowering CherryVine Maple1-1/2" cal1-1/2" cal1-1/2" cal1-1/2" cal1-1/2" calTREE PLANT SCHEDULEAll street trees to be specimen grade with a single leader. Tree height listed is from top of rootball to top of tree at time ofplanting. Damaged trees shall be replaced with same species and minimum 2" caliper.COMMON NAMEQTYSIZEREMARKSPer RMC 4-4-070 (F)(2), minimum 1 street tree planted per address, where curb cuts, driveway, and utilities do not allowthe required trees to be planted.Per RMC 4-4-070 (F)(3), where there is insufficient space or no public frontage, street trees are required in the frontyard.Per RMC 4-4-130(C)(9)(d), minimum of two (2) significant trees is required for every five thousand (5000) square feet ofSingle Family Development. Tree desntiy may consist of a combination of existing trees, replacement trees and streetfrontage landscaping.TREES31122Full and MatchingFull and MatchingFull and MatchingFull and MatchingFull and MatchingFull and Matching/Plant 30" o.c.Full and Matching/Plant 30" o.c.Full and Matching/Plant 36" o.c.Azalea sp. 'Hino Crimson'*Miscanthus sinensis*Euonymus fortunei 'Emerald n Gold'*Lavandula sp.*Rhododendron 'Purple Splendour'*Erica sp. 'Mediterranean Pink'*Bergenia sp. 'Bressingham Ruby'*Arctostaphyllos uva-ursi*Evergreen AzaleaMaiden GrassEuonymusLavenderRhodieHeatherElephant EarKinnikinnik2 gallon2 gallon2 gallon2 gallon2 gallon1 gallon1 gallon1 gallonAs req'dAs req'dAs req'dMGLa*Considered drought tolerant in Pacific Northwest once establishedRHPlant in groups of minimum 15 plants of each species. Hold back 16" from trees, shrubs and adjacent edges.AZ*Considered drought tolerant in Pacific Northwest once establishedSHRUBS and GROUND COVEREgNote: tree caliper is measured 4' above finish gradeBOTANICAL NAMECOMMON NAMEQTYSIZEREMARKS27966PLANT SCHEDULEIN COMPLIANCE WITH CITY OF RENTON STANDARDSJEFF VARLEY landscape architect19819 30th Dr SE Bothell Washington 98012email varley_jeff@hotmail.com phone 425-466-9430www.varleylandscape.comVARLEY VARLEY VARLEYLANDSCAPE PLAN2L-11"=20'-0" SHEET SIZE 22"x34"NORTHEXISTING ONSITE TREETO BE RETAINEDEXISTING ONSITE TREE TO BEREMOVED, TYPICAL. SEE ARBORISTREPORT FOR TREE INFORMATIONTREE PROTECTION FENCE. SEESHEET L-2 FOR TREEPROTECTION FENCING DETAILAND NOTES10' WIDTH LANDSCAPEBUFFER REQUIREDLANDSCAPING WITHIN PUBLICRIGHT OF WAY TO BE INSTALLEDPRIOR TO PLAT RECORDINGONSITE LANDSCAPING TO BEINSTALLED AT THE TIME OFHOME CONSTRUCTION10'-0"2 TREES / 5000 SQ5000 / 10,277 = 2.04 ONSITE TREES REQ'D1 EXISTING TREE3 PROPOSED TREES=4 TREES2 TREES / 5000 SQ5000 / 9,536 = 2.04 ONSITE TREES REQ'D1 EXISTING TREE3 PROPOSED TREES=4 TREES
IN COMPLIANCE WITH CITY OF RENTON STANDARDSJEFF VARLEY landscape architect19819 30th Dr SE Bothell Washington 98012email varley_jeff@hotmail.com phone 425-466-9430www.varleylandscape.comVARLEY VARLEY VARLEYLANDSCAPE NOTES and DETAILS2L-2LANDSCAPE NOTES00000720702TREE PROTECTION DETAILTREE PRESERVATION NOTES1. THE DRIPLINE OF PROTECTED TREES SHALL BE MARKED PRIOR TO CLEARING ANDGRADING ACTIVITIES.2. 3" OF COMPOSTED WOODCHIPS SHALL BE PLACED WITHIN THE DRIPLINE OF ALLRETAINED TREES.3. TREE PROTECTION FENCING SHALL BE PURCHASED IN CONTINUOUS ROLLS AND CUT TOTHE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY,FENCING SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST WITH MIN. 6" OVERLAP,AND SECURELY FASTEN BOTH ENDS TO THE POST.4. THE TREE PROTECTION FENCE SHALL BE INSTALLED AND MAINTAINED AT THE DRIPLINEFOR ALL PROTECTED TREES. FENCING SHALL COMPLETELY SURROUND THE REQUIREDTREE PROTECTION AREA. FENCING SHALL REMAIN IN PLACE UNTIL THE GOVERNINGJURISDICTION AUTHORIZES THE REMOVAL OR ISSUES A FINAL CERTIFICATE OFOCCUPANCY, WHICHEVER OCCURS FIRST.5. TREE PROTECTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBANCEACTIVITIES.6. NO STORAGE OF MATERIALS OR EQUIPMENT WITHIN THE CRITICAL ROOT ZONE ISALLOWED. DURING DEVELOPMENT, NO PERSON SHALL ATTACH ANY OBJECT TO ANYDESIGNATED FOR PROTECTION.7. REPLACE/REPAIR PROTECTIVE FENCING AS REQUIRED.8. GRADE SHALL NOT BE FILLED OR CUT WITHIN THE DRIPLINE OF ANY TREE DESIGNATEDTO REMAIN WITHOUT PRIOR REVIEW BY THE GOVERNING JURISDICTION'S QUALIFIED TREEPROTECTION PROFESSIONAL AND ADVANCE, WRITTEN APPROVAL FROM THE DIRECTOR.9. TO THE GREATEST EXTENT PRACTICAL, UTILITY TRENCHES SHALL BE LOCATED OUTSIDEOF THE ROOT PROTECTION ZONE OF TREES TO BE RETAINED. BORING OR TUNNELINGWITHIN THE PROTECTED ARE MAY BE CONSIDERED AN ALTERNATIVE, BUT SHALL REQUIREDTHE ADVANCE, WRITTEN APPROVAL OF THE DIRECTOR.10. TREES AND OTHER VEGETATION TO BE RETAINED SHALL BE PROTECTED FROM EROSIONAND SEDIMENTATION.00