Loading...
HomeMy WebLinkAboutMFP20005122.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20005122 IVR Number: 20005122 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:11/04/2020Application Date:0323059096Parcel Number: 2741 WHITMAN PL NE, LOT Permit Type:11/06/2020Issue Date:Franchise Permit Work Class:11/08/2021Expiration Date:Minor Utility Job Number: 105090792Franchise Type:Electric Description: Puget Sound Energy Electric ER CITY OF RENTON'S BRAD STOCCO'S REQUEST. 1Ø PRIMARY U/G LINE EXTENSION SERVING 19 NEW SINGLE FAMILY HOMES. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL SOUND BUILDING & DEVELOPMNT 23837 43RD AVE S KENT , WA 98032 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 1ϭ/Ϯϱ/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.܆ A copy of the Traffic Control Plan (TCP) Application form. 2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ܆ Include map(s) showing the location of the project and work area. ܆ Be legible lettering and clear, contrasting, symbols of viewing or printing. ܆ Must indicate street names, and north arrow and scale. ܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ܆ Types of plans required: ܆ Work hour plan – show all mobility impacts during construction hours. ܆ Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ܆ Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ܆ Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering MFP20005122 Scott Warlick CED 11/6/2020 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019 APPLICANT AGREES TO ALL THE FOLLOWING: x TCP must be approved prior to commencing the work, and all permit conditions shall be met. x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). x Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. x Approved Temporary TCP must be at the work site during work hours. x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. x Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date W H I T M A N PL NE WHITMAN PL NE WHITMAN PL NE SE 95T H WA Y SE 95 T H W A Y P01 ADJUST CONTROLS AS NEEDED FOR SE LANE WORK SINGLE PHASE PRIMARY U/G LINE EXTENSION TRENCHING ROUGHLY 50' NW & 50'SW ONTO CUSTOMERS PROPERTY UTILITY WORK AHEAD W21-7 ONE LANEROADAHEAD CW20-4 W20-7A UTILITY WORK AHEAD W21-7 ONE LANE ROAD AHEAD CW20-4 W20-7A 100' 100' 100' 100' W20-7A BE PREPARED TO STOP W20-7b UTILITY WORK AHEAD W21-7 K&D Services, as the preparer of this traffic control plan makes no representation as to its' general adequacy or being approved for implementation. Approval must result from the Traffic Engineer or other Public Official having statutory enforcement authority in the jurisdiction. Utilization and implementation of this plan shall be a result of that approval. Ref. MUTCD 2009 6A-01 (10) Notes: 1. Maintain ped. access to and through crosswalks 2. Maintain Min. 10' lanes 3. Maintain local access 4. Notify Transit Authority at least 48 hrs. in advance of bus stop closure 5. Traffic control plan and all devices shall comply with MUTCD, PROWAG & WSDOT 6. DEVICE SPACING Flag Taper 20' Signs per WSDOT Tapers per WSDOT 7. 28" Cones 36" Barrels 48" Signs 24" Paddle 8. Adjust to field conditions PLEASE SCHEDULEWITH DISPATCH @ 800-343-4049 OPT.1 AND PROVIDE A COPY OF THE APPROVED TRAFFIC CONTROL PLAN Legend ConeONE LANEROADAHEAD CW20-4 one lane road ahead Flagger Pole W20-7A Flagger AheadBE PREPAREDTO STOP W20-7b be prepared to stopUTILITYWORKAHEADW21-7 utility work ahead Work Truck INVENTORY: 3-UTILITY WORK AHEAD 3-FLAGGER AHEAD 2-ONE LANE ROAD AHEAD 1-BE PREPARED TO STOP 3-FLAGGERS 15-CONES NOT TO SCALE N S EW NOTIFY EMS, FIRE AND POLICE 72 HOURS IN ADVANCE NOTIFY EMS,FIRE AND POLICE72 HOURS IN ADVANCE CUSTOMER: CONTACT: LOCATION: DATE:W/O # Designed By: Garrett Hooper Off:800-343-4049 Ext 5860Cell # 425-551-8297WATCP@KNDSERVICES.NET WSTCS#010855 PUGET SOUND ENERGY MITCH PETERSON 425-398-6071 13429 SE 95TH WAY RENTON, WA 4-23-19 105090792 www.invarion.com MFP20005122 W H I T M A N PL NE WHITMAN PL NE WHITMAN PL NE SE 95T H WA Y SE 95 T H W A Y P01 ADJUST CONTROLS AS NEEDED FOR SE LANE WORK SINGLE PHASE PRIMARY U/G LINE EXTENSION TRENCHING ROUGHLY 50' NW & 50'SW ONTO CUSTOMERS PROPERTY UTILITY WORK AHEAD W21-7 ONE LANEROADAHEAD CW20-4 W20-7A UTILITY WORK AHEAD W21-7 ONE LANE ROAD AHEAD CW20-4 W20-7A 100' 100' 100' 100' W20-7A BE PREPARED TO STOP W20-7b UTILITY WORK AHEAD W21-7 K&D Services, as the preparer of this traffic control plan makes no representation as to its' general adequacy or being approved for implementation. Approval must result from the Traffic Engineer or other Public Official having statutory enforcement authority in the jurisdiction. Utilization and implementation of this plan shall be a result of that approval. Ref. MUTCD 2009 6A-01 (10) Notes: 1. Maintain ped. access to and through crosswalks 2. Maintain Min. 10' lanes 3. Maintain local access 4. Notify Transit Authority at least 48 hrs. in advance of bus stop closure 5. Traffic control plan and all devices shall comply with MUTCD, PROWAG & WSDOT 6. DEVICE SPACING Flag Taper 20' Signs per WSDOT Tapers per WSDOT 7. 28" Cones 36" Barrels 48" Signs 24" Paddle 8. Adjust to field conditions PLEASE SCHEDULEWITH DISPATCH @ 800-343-4049 OPT.1 AND PROVIDE A COPY OF THE APPROVED TRAFFIC CONTROL PLAN Legend ConeONE LANEROADAHEAD CW20-4 one lane road ahead Flagger Pole W20-7A Flagger AheadBE PREPAREDTO STOP W20-7b be prepared to stopUTILITYWORKAHEADW21-7 utility work ahead Work Truck INVENTORY: 3-UTILITY WORK AHEAD 3-FLAGGER AHEAD 2-ONE LANE ROAD AHEAD 1-BE PREPARED TO STOP 3-FLAGGERS 15-CONES NOT TO SCALE N S EW NOTIFY EMS, FIRE AND POLICE 72 HOURS IN ADVANCE NOTIFY EMS,FIRE AND POLICE72 HOURS IN ADVANCE CUSTOMER: CONTACT: LOCATION: DATE:W/O # Designed By: Garrett Hooper Off:800-343-4049 Ext 5860Cell # 425-551-8297WATCP@KNDSERVICES.NET WSTCS#010855 PUGET SOUND ENERGY MITCH PETERSON 425-398-6071 13429 SE 95TH WAY RENTON, WA 4-23-19 105090792 www.invarion.com MFP20005122 W H I T M A N P L N E SE 9 5 t h W A Y COAL CREEK PKWY SE 42' R50'TRACT B26' 42' EXISTING 1Ø AØ - AEC304 BØ - AEC305 CØ - AEC306 EXISTING FEEDER AØ - AEC262 BØ - AEC263 CØ - AEC264 60' SITE PLAN N Vicinity Map 47.515892, -122.159773 Owner / Developer Contact Info officeATTN: SOUND BUILDING & CONSTRUCTION 23905 43rd AVE S KENT, WA 98032 JASWINDER SINGH 206-790-5385 PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 105092300 N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Comm. H.H. Relocation Removal Misc. Wire Job Order Distribution HP Svc/MSA 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 105090792107057815SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 710' 27 3000 115 AMPS 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:RANDY BLACKIE 425.457.2614 randy.blackie@pse.com SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RANDY BLACKIE 425.457.2614 01/25/19 K.COSTLEY 425.272.7075 08.18.20 K.COSTLEY 425.272.7075 08.18.20 JOHN SINGLETON 425-417-1149 01/25/19 RW - 113350 NEWCASTLE CHRISTELLE RIDGE 1Ø PRIMARY U/G LINE EXTENSION - 19 S/F LOTS (P#0323059096) SE 95TH WAY & DUVALL AVE NE, RENTON, WA 98058 N/A IP 088-60 107057815 105090792 1" = 50'1 OF 3 KING 30 CIKNC QCSOKE SEC3-T23N-R05E 204.086 204.086 2305E010 2305E040 2305E010 PRE-14 COMCAST BILL WALKER 253.288.7538 CENTURY LINK KENNETH LUU 206.346.0144 R.O.W. ALEX MALESIS 425-462-3436 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105090792 107057815 106350397 506672616 506672613 JOINT TRENCH DETAIL Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter, install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller, install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 Primary & Secondary-Mainline Gas & Communications (NTS) OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE REQUESTING TO CLOSE N.O. @ THIS LOCATION DURING CONSTRUCTION, CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE PRE-14 5/22/19 364 408 385 17 -- 381 408 385 VAULT DETAIL @ V01,V02 & V03 NOT TO SCALE TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONT575 HH 2" Excavation - 19-1/2 cubic yards SIDE VIEW 5'-4"Crushed 6" Rock TOP VIEW 9' 11' 7'-0" 4'-0" 1' 4'-8" VAULT DETAIL @ J01 NOT TO SCALE SITE SPECIFIC NOTES At J01 (319122-167248) -INTERCEPT EXISTING 1/0 - 3Ø FROM P01 TO J02 -INSTALL EXISTING CABLE #'s (AØ-AEC304, BØ-AEC305 AND CØ-AEC306) -SEE TABLES ON PAGE 2 FOR EQUIPMENT INSTALL At P01 (319138-167247) -INSTALL 1/0 AL 3PH PRIMARY TERMINATION ON EXISTING ARM -INSTALL (3) LOAD INTERUPTORS & SURGE ARRESTERS, FUSE @ 100T (3412700) -INSTALL SWITCH # T82113 -INSTALL (3) STIRRUPS (2254100) -INSTALL 4” PRIMARY RISER ON EXISTING STANDOFF BRACKETS SITE #FROM TO H1A LOT 1 20 DED. CONDUIT & WIRE 2-36, 2-54A V03 LOT 6 35 DED. CONDUIT & WIRE 2-36, 2-54A V02 LOT 9 45 DED. CONDUIT & WIRE 2-36, 2-54A V01 LOT 17 35 DED. CONDUIT & WIRE 2-36, 2-54A 135 DEDICATED FACILITIES (105090792) fStub Location & RF XFMR SPAN ADDITIONAL FOOTAGE REMARKS LABOR UNITS TOTAL FT. = CROSSINGS CONDUIT TABLE GAS POWER Length X-ING Location Size Type Qty Location Size Type Qty NO.from to (in)sched each N-S-E-W (in)sched each (ft) X01 "A"LOT 20 NO GAS 2 80 1 70 PRIMARY ONLY X02 LOT 20 LOT 1 2 40 1 SOUTH 3 1 50 GAS SVC, SECONDARY X03 LOT 16 LOT 11 4 40 1 WEST 2 1 30 GAS MAIN, PRIMARY X04 LOT 15 LOT 12 2 40 1 EAST 3 1 30 GAS SVC, SECONDARY X05 LOT 7 LOT 3 2 40 1 WEST 3 1 50 GAS SVC, SECONDARY X06 LOT 6 LOT 4 2 40 1 WEST 3 2 50 GAS SVC, SECONDARY 2" SCHED 40 YELLOW PVC (ft) =180 4" SCHED 40 YELLOW PVC (ft) =30 100 2" SCHED 80 GREY PVC (ft) 230 3" SCHED 80 GREY PVC (ft) Total 2" PVC Plug /Caps =8 Total 4" PVC Plug /Caps =2 4 = Total 2" PVC Plug Caps 10 = Total 3" PVC Plug Caps Remarks (type of crossing) (Primary, Feeder, Secondary, St. Light, Gas only, etc.,) 80 80 80 80 80 WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P01 J01 1/O PRIMARY 3 50' Total Feet (Wire Size & Type) Removed N/A N/A N/A RETURN SYSTEM TO NORMAL AFTER CONSTRUCTION DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H1C TO METER LOCATION CIRCUIT FEET REMOVED: 50' REDUCED FLAMMABILITYV03 -RETIRE SWITCH # X9719 At GRID (318910-1673416) -CLOSE EXISTING NWO DURING CONSTRUCTION -RETURN TO NORMAL UPON COMPLETION OF CONSTRUCTION (SEE OH-MAP) MFP20005122 EXISTING 1Ø AØ - AEC304 BØ - AEC305 CØ - AEC306 EXISTING FEEDER AØ - AEC262 BØ - AEC263 CØ - AEC264 PROPOSED 1Ø AØ - EHS413 PROPOSED 1Ø AØ - EHS410 BØ - EHS411 CØ - EHS412 PROPOSED 1Ø AØ - EHS415 PROPOSED 1Ø AØ - EHS414 PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM SCALE: NONE UNDERGROUND CIRCUIT MAP (2305E010) SCALE: 6" = 1 MILE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PRIMARY CABLE & CONDUIT TABLE CONDUIT LOCATION Size Qty Design BENDS PULL PULL Cable Design Foreman- Complete Cable Numbers from to (in) Length (ft)90°45°22°11°(lbs) Rev (lbs)Size (ft)A B C Manufacturer Compound Year P01 J01 4 1 20 2 1/0 AL JKT 80 EHS410 EHS411 EHS412 J01 V01 2 1 380 1 3 1 1/0 AL JKT 400 EHS413 V01 V02 2 1 140 2 2 1/0 AL JKT 160 EHS414 V02 V03 2 1 190 1 2 1/0 AL JKT 210 EHS415 V03 E01 2 1 10 1 1 2" PVC (ft) & Bends =720 2 4 7 3 1.23 0.51Qts 850 = Total 1/0 AL JKT (ft) PRIMARY CABLE Foreman Please Record Actual Amount Installed (Conduit & Cable) ASBUILT Vault & Equipment Table Site Grid Vault Size Type & Size Primary Bushings Transformer ASBUILT INFORMATION Number & Cover Equipment ID Numbers Foreman-Complete in Vault LB DC (Company ID)(Include Trf Phase tapped) 50 KVA MP TRF Unistrut HH 120/240 2 -MINU1SL 6045.1010 AØ Matid:Matid:6247100 42X48X38 37.5 KVA MP TRF Unistrut HH 120/240 2 -MINU1SL 6045.1010 AØ Matid:7663001 Matid:6247050 42X48X38 50kVA RF MP Unistrut HH 120/240 1 1 MINU1SR 6045.1010 AØ Matid:7663001 Matid:9995529 4'8"x7'x5'J-Box Below Grade w/2-3' Sq Doors w/4-Pos J-Bus x3 7 5 JBOX15L 6055.1030 Matid:7663200 Matid:7625900 CAP (7630600) J01 319122 167248 V01 V02 V03 319099 167249 319090 167243 319091 167224 MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED TRANSFORMER TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF3' 3' REDUCED FLAMMABILITY 3' @ V01 & V02 @ V03 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RANDY BLACKIE 425.457.2614 01/25/19 K.COSTLEY 425.272.7075 08.18.20 K.COSTLEY 425.272.7075 08.18.20 JOHN SINGLETON 425-417-1149 01/25/19 RW - 113350 NEWCASTLE CHRISTELLE RIDGE 1Ø PRIMARY U/G LINE EXTENSION - 19 S/F LOTS (P#0323059096) SE 95TH WAY & DUVALL AVE NE, RENTON, WA 98058 N/A IP 088-60 107057815 105090792 AS STATED 2 OF 3 KING 30 CIKNC QCSOKE SEC3-T23N-R05E 204.086 204.086 2305E010 2305E040 2305E010 PRE-14 COMCAST BILL WLAKER 253.288.7538 CENTURY LINK KENNETH LUU 206.346.0144 R.O.W. ALEX MALESIS 425-462-3436 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SITE 7663001 Length 4" PVC (ft) & Bends =20 2 0.19 0.17Qts 42X48X38 OVERHEAD CIRCUIT MAP (2305E040) SCALE: 6" = 1 MILE SITE CLOSE THIS NWO DURING CONSTRUCTION MFP20005122 SCALE: NONE CONDUIT DIAGRAM TYPICAL NOTCH-OUT FOR TRANSFORMER, SCALE: NONE & SECONDARY PEDESTAL/HANDHOLE BACK OF EASEMENT STANDARD EASEMENT LINE ROW 10' PL 1' 4' - 5' Min. 1' 7'7' TRANSFORMER (WHEN PRESENT) CONDUIT LEGENDS SECONDARY 2" SECONDARY 3" PRIMARY 2" PRIMARY 4" 42" 45°42" 1' 45°Property LineRoad Side Top View of Mainline Trench for Single Stubout Location 3'Property LineRoad Side Top View of Mainline Trench for Pedestal or Double Stubout Location 42"45° 3' 45° STUBOUT EXCAVATION DIMENSIONS Not to scale THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) @ H1B SHALL BE STAGGERED CONNECTOR BARS IN THE FRONT NEUTRALS SHALL BE 18" 16" 13" 12"10" 2" 10" Pedestal will accept up to six 3" conduits SEALED WITH FOAM CONDUIT SHALL BE 120 PVC CONDUIT ELBOWS TYPICAL 24" RADIUS DB SIDE VIEW WITH CONDUIT 10" 18"16" 13" 10" 2" 36" FRONT VIEW WITH CONDUIT Lock Cover Captive L-Bolt service Customer's conductors Set handhole flush to final grade Side View 17" Approx 30" Approx 2" 18" Captive L-Bolt Lock Cover, 10 lbs 40-1/2"27-1/4" Conductors enter from beneath and shall be folded back with handhole SECONDARY HANDHOLE DETAIL NOT TO SCALE SECONDARY HANDHOLE DETAIL @ H1A NOT TO SCALE SECONDARY HH/PEDESTAL TABLE Site Pedestal Number of Remarks or Positions (Include phasing information) Handhole Required H1A Handhole 5 HH16350(6050.2000) AØ H1B Pedestal 5 SEPL6(6050.1000) AØ H1C Handhole 2 HH13350(6050.2000) AØ - CHARGE TO 105092300 ROAD SIDE NATIVE SECONDARY POWER ROAD SIDE MINIPAD MINIPAD FIELD SIDE PEDESTAL MATERIAL VAULT 6" of crushed rock (base for vault) P/L P/L Power Secondary Power Primary Power Secondary Power Primary Conduit Tel. & TV 12" Min 12" Sand Cover when gas line is in trench Sand 6" or 12" 4" Sand Bedding Gas 12" Min Horizontal Separation Communications 42" Min 21"1' 1' 36" Cover 42" Gas 12" 18" Lower 2" 10" Feeder 38" 2" 4" Sand Bedding 12" Sand Cover 36" Cover 4" Sand Bedding 42" 6" Additional depth when Feeder is required PSE 10' FRONTAGE EASEMENT 1' TRANSFORMER Pedestal PSE 10' FRONTAGE EASEMENT 1' Final Backfill Initial Backfill Trench Depth 42" - 48" JOINT TRENCH DETAIL Not to scale Cover UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP RANDY BLACKIE 425.457.2614 01/25/19 K.COSTELY 425.272.7075 08.18.20 K.COSTLEY 425.272.7075 08.18.20 JOHN SINGLETON 425-417-1149 01/25/19 RW - 113350 NEWCASTLE CHRISTELLE RIDGE 1Ø PRIMARY U/G LINE EXTENSION - 19 S/F LOTS (P#0323059096) SE 95TH WAY & DUVALL AVE NE, RENTON, WA 98058 N/A IP 088-60 107057815 105090792 AS STATED 3 OF 3 KING 30 CIKNC QCSOKE SEC3-T23N-R05E 204.086 204.086 2305E010 2305E040 2305E010 PRE-14 COMCAST BILL WALKER 253.288.7538 CENTURY LINK KENNETH LUU 206.346.0144 R.O.W. ALEX MALESIS 425-462-3436 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed CONDUIT VOLTAGE VOLTAGE ASBUILT INFORMATION SIZE LENGTH Lot Corner SIZE LENGTH BENDS DROP FLICKER Foreman - Complete FROM TO (1/O,4/O, 350) Design (ft) to Meter (ft)(in) Design (ft) 90°45°22°11°(Percent)(Percent) Actual Amount Installed (Conduit & Cable) V01 H1A 350 155 3 155 2 1 2.5 2.2 V01 H1B 350 130 3 130 3 1 2.4 2.1 H1A H1C 350 95 3 95 2 2 2.5 2.8 V01 LOT 16 1/O 20 50 2 20 1 2.2 2.5 V01 LOT 17 1/O 50 50 2 50 1 1 2.5 3.1 V01 LOT 18 1/O 55 50 2 55 1 1 2.6 3.1 H1A LOT 1 350 140 50 3 90 2 1 1.4 3.6 4/O TO METER ( SEE V-DROP) H1A LOT 19 1/O 50 2 2.9 3.1 H1A LOT 20 1/O 50 2 2.9 3.1 H1B LOT 12 4/O 65 50 3 35 2 3.2 3.6 H1B LOT 13 4/O 70 50 2 70 1 3.2 3.7 H1B LOT 14 1/O 50 2 2.9 3.0 H1B LOT 15 1/O 50 2 2.9 3.0 V02 LOT 8 4/O 65 50 2 65 1 1 2.0 3.4 V02 LOT 9 4/O 60 50 2 60 1 1 2.0 3.3 V02 LOT 10 1/O 20 50 2 20 1 1.9 3.1 V02 LOT 11 4/O 75 50 2 75 1 1 2.1 3.5 V03 LOT 3 4/O 135 50 3 85 2 2.1 3.5 V03 LOT 4 1/O 85 50 3 35 2 2.3 3.7 V03 LOT 5 1/O 80 50 3 30 2 2.2 3.6 V03 LOT 6 1/O 50 50 2 50 1 2.0 3.1 V03 LOT 7 1/O 55 50 2 55 1 2.0 3.1 1/O UG Triplex (ft) =415 2" PVC & Bends =520 10 5 1.1 4/O UG Triplex (ft) =470 3" PVC & Bends =655 17 1 4 2.2 350 UG Triplex (ft) =520 Total Qts of Glue =3.3 CHARGE TO 105092300 SIDE VIEW 18" 23-1/4"32-3/4" 2" Captive L-Bolt Lock Cover, 10 lbs 24" Approx Approx 13" Customer's service conductors 4-3/4" X 4-3/4" KNOCKOUT IN 2 PLACES Conductors enter from beneath and shall be folded back with handhole Set handhole flush to final grade Captive L-Bolt Lock Cover SINGLE PHASE SECONDARY HANDHOLE Not to scale 6050.2000 @ H1C MFP20005122