Loading...
HomeMy WebLinkAboutR-395506U")LO LO C? M CO N N � � I z O G 75 O U z O z w rr CD / / V I N L L l \\ I \\ L I V TV AND TEL NOT LOCATED IN THIS AREA c0 TELEPHONE VAULT ELEC AND WATER MAIN x / IN CURB LINE TV / 8 PV BRICK STA 12+29.50, 0.33' RT CONCRETE SIDEWALK FIRE HYDRANT MARKER L PER COR STD PLAN 310.3 WHITWO 12+35.7, 13.0' RT TEE ------ ---- - TOP 12" DI ELEV.=27.2'----- ---- -- _...... STA rn 12771i RT CONNECT TO EX. SR 2" DOME C WATER SRVC STUB W/ REQ. FITTINGS I o CO MPER-COR STD PI D f 320.2 S D - 12+74.9, 13.0' RT . TOP 12" DI ELEV.=27.6' ' STA RT 6" SIDE SEWER PER �„� o I (1) 12 GATE VALVE (MJ) COR STD PLAN 406 1 STA l i+75. 5, 1 .�T H AVE, 0 �m BRICK GAS VALVE 1 1 CD COORD. COR TRANSFER SERVICE TO NEW 12" All+ r E--------- - ---- U t�_w SERVICE TRANSFER ------ U DON Y COR CREWS AFTER 0 H SD MAIN IS OPERATIONAL. W �u SD- 1 = I� 12.9' SEE OJTE21156 9 BEISIN PIPE nr1 rnTin.i 252 LF 12" DI WATER i W 12+38.0, CD - TOP VALVE ELEV.=28.7. S A N I Thka( E E� M A I 0 I13+50 w - ----jZ 'EMENT T IPING I I I I I GAS MAIN PER I I J FIELD LOCATES I STA 13+30.00, 14.5 RT N I W ' END PIPE DEFLECTIO I = --- --___ - -=---- ---�_ - _�_=12+94.3,13.3'RT G-0� 13+36.1 14.4'RT ff All „ TOP 12" DI ELEV.=27.6' -a - G TOP 1-1/2" IRON H2O RUNNING EAST -WEST ELEV.=30.7' N o cn 13+46.7, 14.6 RT MET R TOP 12" DI ELEV =27 2' 0 0 HH� I V V DU T TEL DUCT ----------- ,UCT 12+17.7, 21.5' RT -- - CQ ---- ------ --- -- ----- ----- - 4" CO D IT PS I V VEY - --- ------------ - R S I D E WA K---- -1--v ---------------- i �RAIVCHiSE E fiE ------ CON. P B W R POLYPIG OBTAINED P OUT UNDE D TO 97 - - - ETER BO ER COR F 0 Q I 12+29.9, y � � � STRE LI HT H N (1) 4" CONDUIT (CLINK) i � x ST 2.00 RT UNDER SEPARATE FRANCHISE / I TE L E P ]ONE V A U L T- RFIYDRANT SERE ER S EET 6.0 �� PERMIT OBTAINED BY I CENTURY LINK 4" FIRE RVICE%D D6 /PIV P� OR STD P N 12+85.1, 13.2' RT 3 PROVIDE' c3'x1.5' / Q F TOP 12' DI ELEV.=27.5' I E HIED ROCK SUMP ( 12+55.8, 13.1' RT TOP TAP WEST ELEV.=27.3' I i Q� EL W VAU1IN HOLE 0 WILKINS 350XL DCVA PE TOP 12" DI ELEV.=27.6' COR S D PLAN 340.8 , n L b 1 I J 12+85.4, 22.8' RT C DAVID EVANS AND ASSOCIATES INC. WATER METER I I x 20300 WOODINVILLE SNOHOMISH ROAD I a _ C)0 Q NORTHEAST, SUITE A. 425-415 2000 i t AS CONSTRUCTED FIELD INFORMATION DEPICTED c G I ON THIS MAP REPRESENTS THE RESULTS OF A SRVEY MADE ON DEC. 13, 2017, DEC. 14, 2017, DEC. 18, 2017, JANUARY 12, 2018 AND MARCH 12, 2018 AND CAN ONLY BE CONSIDERED AS INDICATING THE GENERAL CONDITIONS EXISTING AT THAT TIME. 40 30 . . . . . . . F PROP. 6" _ SS CROSSING SS .PIPE BOTTOM: 28.30 WATER PIPE TOP: 27.63 . . . . . . . . . . . . J W �.� . .M.�. .. o EX. SS CROSSING . . . . . . z �p o r� TO BE ABANDONED . . . . NU �! W r) 4Wi w x" x `-� �. C) . . w 20 :SOY Q Z Yg � J U � J U jam. Q 0 cl cl 0 Q C) LU LLI C' L'U C, cn c:1 0 N � N. j.� Z N o N ZLLI N N Q N� Q N M N O.O . . . + CV w Q CD NJM + N + NCO <t + CV 'x C7 N .+ N x C' Na + C4 W �.N . L Wr7 + CV . . N Um � �U ��cnF_ ���� �p�zZ. U) W �C/) m C/) C/) M a- Cn :�. (/) . :� U) CV U d En � 11+70 12+00 12+50 WATER MAIN PROFILE SCALE: HORX. 1 " = 10' VERT. 1 " = 5' Al design PLLC A CIVIL ENGINEERING COMPANY L,.; 219 First Avenue S., Suite 401 a Seattle WA 98104 J 206 402 4644 LL 1►[•l REVISION PROPOSED 12" WATER MAIN 13+00 SURVEYED: DESIGNED: TTG DRAWN: TTG CHECKED: WE BY DATE APPR APPROVED: 13+50 SCALE: VERnCAL. NAVD 1988 1 " = 10' HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Ell] 35 30 25 K11 15 CALL 48 HOURS BEFORE YOU DIG! 811 } CITY OF RENTON Planning/Building/Public Works Dept. Z T 0 0 LEGEND CONIC THRUST BLOCKING PER COR STD PLAN 330.2 AND 330.3 GATE VALVE AND VALVE BOX PER COR STD PLAN 330.1 FIRE HYDRANT PER COR STD PLAN 310.1 WATER METER PER COR STD PLAN 320.2 1" WATER SERVICE U.N.O. 12" DI CLASS 52 WATER MAIN U.N.O. 6" PVC SDR 35 ASTM 3034 (U.N.O.) SANITARY SEWER SERVICE ELECTRICAL CONDUITS TEL/DATA CONDUITS NOTES 1. SEE SHEET C1.0 AND C1.1 FOR GENERAL NOTES. 2. SEE SHEET C6.0 FOR PAVEMENT RESTORATION PLAN. 3. VERIFY INVERTS OF ALL EX. SYSTEMS AT PROPOSED POC'S TO NEW LINES PRIOR TO ORDERING OF MATERIAL AND NOTIFY ENGINEER OF ANY DISCREPANCIES AT LEAST 4 WORKING DAYS PRIOR TO STARTING PIPE LAYING OPERATIONS. 4. COORDINATE ALL UTILITY INTERRUPTIONS WITH AFFECTED FACILITY OWNERS. PROVIDE MINIMUM 2 WEEKS ADVANCE NOTICE OF ALL INTERRUPTIONS. 5. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS DURING TRENCH EXCAVATION TO PROTECT EXISTING UTILITIES FROM DAMAGE AND SETTLEMENT. 6. ALL CONCRETE BLOCKING FOR HORIZONTAL BENDS, TEES AND VERTICAL BENDS SHALL BE PER COR STD PLANS 330.2 AND 330.3. 7. ALL MECHANICAL JOINTS FITTINGS AND VALVES SHALL HAVE RESTRAINED GLANDS EQUAL TO MEGALUG SERIES 1100 OR ROMAC ROMAGRIP, EXCEPT WHERE SHACKLE RODS ARE INDICATED. 8. SHACKLE RODS SHALL BE INSTALLED PER COR STD PLAN 330.5. 9. PIPE JOINT DEFLECTION SHALL NOT EXCEED HALF OF THE MANUFACTURE'S ALLOWABLE DEFLECTION. 10. SCHEDULING FOR THE WATER CUT -IN CONNECTION AT S 3RD STREET SHALL BE COORDINATED BY THE CONTRACTOR WITH THE CITY PUBLIC WORKS INSPECTOR AND CITY PROJECT MANAGER. ALL CONNECTIONS TO THE EXISTING WATER MAIN NEED TO BE COMPLETED BY CITY MAINTENANCE CREWS. THE CONTRACTOR IS RESPONSIBLE FOR EXCAVATION OF THE TRENCH, SHORING OF THE TRENCH AND SUPPLYING THE MATERIALS NEEDED FOR THE CUT -IN. 11. PORTION OF SIDE SEWER CROSSING OVER WATER MAIN SHALL BE CONSTRUCTED WITH (1) STICK OF PVC C-900 PIPE, CENTERED ON WATER MAIN. Q J co O 0 T WE H S-395502 W-395502 R-395506 w IN COMPLIANCE WITH CITY OF RENTON STANDARDS M0 W DEVELOPMENT ENGINEERING (/) a- I I Fitz -James 12/13/2017 zO 73 2 O DATE: U RENTON COMMONS LLC 12/13/2017 z 215 WHITWORTH AVE S, RENTON, WA 98057 FIELDBOOK: O PAGE: DRAWINGZ ROW UTILITY PLAN C 5.0 ` AND PROFILE SHEET:6 OF:26 0�