HomeMy WebLinkAboutR-395509Ln m C'7 O I 0 W U) z 75 O 0 z O z W rr m a z J u_ IN ROW, SAWCUT AND RESTORE PAVING IN PER CITY OF RENTON TRENCH RESTORATION AND OVERLAY REQUIREMENTS EX PAVING ON SITE: IMPORTED — STRUCTURAL FILL COMPACTED IN 8" MAX LIFTS TO 95% DENSITY. IN ROW: CDF BACKFILL PER COS REQ. MIN. AGG. TYPE - 22 COMPACTED TO 95% DENSITY W MAX W=1.5 x PIPE DIA + 18"MIN FOR 6" W=27"MIN 8" W=30"MIN 12"W=36"MIN TYPICAL TRENCH SECTION NC RESTORE 1 LANDSCAPE PER LA PLANS WYE OR 1/8 BEND CLEANOUT NTS Z. 00ol NTS X < /5\ x z NOTES: 00 :5i 30" RING &COVER 1. CATCH BASINS TO BE CONSTRUCTED IN ACCORDANCE W/ ASTM C 478 (AASHTO M 199) & ASTM C 890 UNLESS OTHERWISE SHOWN ON PLANS J OR NOTED IN THE STANDARD SPECIFICATIONS. = 00 .:..:•. -' HANDHOLDS ' 2. HANDHOLDS IN RISER OR ADJUSTMENT SECTION SHALL HAVE 3" MIN. _... 30" DIAMETER '• FLAT SLAB COVER CLEARANCE, STEPS IN CATCH BASIN SHALL HAVE 6" MIN. CLEARANCE. NO STEPS ARE REQUIRED WHEN "B" IS 4' OR LESS. STEPS AND LADDER SIZE PER PANS 3. ALL REINFORCED CAST IN PLACE CONCRETE SHALL BE CLASS A. ALL =~ '' j• ' PRECAST CONCRETE SHALL OBTAIN 4000 PSI @ 28 DAYS. 4. PRECAST BASES SHALL BE FURNISHED W/ CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MIN. m =" 5. KNOCKOUT OR CUTOUT HOLE SIZE IS EQUAL TO PIPE OUTER DIA. PLUS MORTAR >= z PRECAST BASE W/ CATCH BASIN WALL THICKNESS. MAX. HOLE SIZE IS 36" FOR 48" CATCH FILLET y' INTEGRAL RISER BASIN, 42" FOR 54" CATCH BASIN. MINIMUM DISTANCE BETWEEN ';. GRAVEL BACKFILL HOLES IS 8". 1 "J 6" ~ 1 " FOR PIPE BEDDING, 6" MIN. COMPACTED 6. RING & COVER SHALL BE IN ACCORDANCE W/ STANDARD 48 DIA.-6 54"DIA.-8" * -0" DEPTHFOR PRECAST , SPECIFICATIONS & MEET THE STRENGTH REQ'MTS OF FEDERAL SPECIFICATION RR F621D MATING SURFACES SHALL BE FINISHED BASES ONLY REINFORCING STEEL TO ASSURE NON -ROCKING FIT. (FOR PRECAST BASE W/ INTEGRAL RISER) 0.15 SO. IN/FT IN EACH DIRECTION FOR 48"DIA. 7. ALL BASE REINFORCING STEEL SHALL HAVE A MIN. YIELD STRENGTH 0.19 SQ. IN/FT IN EACH DIRECTION FOR 54"DIA. OF 60,000 PSI & BE PLACED IN THE UPPER HALF OF THE BASE "0"RING SEPARATE CAST IN PLACE OR WITH 1" MIN. CLEARANCE. SEPARATE PRECAST BASE 8, THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE ROUNDED. REINFORCING STEEL (FOR SEPARATE BASE ONLY) 0.23 SQ. IN/FT IN EACH DIRECTION FOR 48"DIA. 0.19 SQ. IN/FT IN EACH DIRECTION FOR 54"DIA. ' FOR SEPARATE CAST PRECAST BASE JOINT IN PLACE ONLY. 5 CB TYPE 2 NTS 7 design PLLC A CIVIL ENGINEERING COMPANY 219 First Avenue S., Suite 401 Seattle WA 98104 206 402 4644 CONCRETE PRE MOLDED JOINT FILLER 2 BID ADDENDUM # 1 3 BID ADDENDUM # 2 5 CONSTRUCTION ASI-1 CASTING PER NOTE 3 PROVIDE BLOCK IN LANDSCAPED AREAS TEST PLUG RISER DIAMETER SHALL MATCH PIPE RUN nv .�nm� mnivivu� n.� MAIN SEWER JOINTS DOWNSPOUT CONNECTION NTS NO. I REVISION SURFACING PER PLAN PATIO DRAIN, JR SMITH MODEL 2010 WITH 8" TYPE A STRAINER, NICKEL BRONZE FINISH, 4" NO HUB OUTLET FERNCO STRONGBACK RC CPLG PATIO DRAIN Cx4" REDUCER C-45' BENDS 6" PVC SDR 35 ASTM 3034 @ S = 2% MIN. CONNECT TO DOWNSTREAM SD PIPE OR STRUCTURE PER PLANS STD. LIGHT DUTY BRONZE GRATE. ALL GRATES SHALL BE LOCKING 8" DIAMETER NYLOPLAST DRAIN BASIN WITH PVC OR CPEP SLOPE %\ OUTLET STUB AS MFR'D BY TO DRAIN \\HANCOR INC. OUTLET PIPE PER PLAN `D INTEGRALLY MOLDED STUB NOTES: PROVIDE ADDITIONAL STUB AS REQ'D FOR INLEfTING PIPES. RIM AND INVERT ELEVATIONS PER PLANS. AREA DRAIN NTS 00ol NTS FERNCO COUPLING TRANSITION SECTION 90° STREET ELBOW AND EXTENSION AS REQUIRED 6" PVC SDR 35 ASTM 3034 @ S = 2% MIN. TO CONNECT TO SD PER PLAN 08 18 2017 SURVEYED_ 08 29 2017 DESIGNED: 11 15 2017 DRAWN: TTG CHECKED: MJE BY DATE APPR APPROVED: THICKEN CONCRETE PAVING SECTION TO 8" AROUND STORMFILTER 2 UNIT ACCESS COVER (2) #6 REBAR d o A A dof �� a mob ° z o neI A ..e " e c I d 'i e ° e VANED INLET GRATE 2'4" 2'-4" 1(TYP) INSIDE RIM INSIDE RIM 4'-83/4" - OUTSIDE RIM PLAN VIEW FLOATABLES BAFFLE PERMANENT POOL ELEVATION FINISHED GRADE 1111111111�1111= ii11II FILTRATION BAY INLET OUTSIDE SECTION B—B STORMFILTER CB NTS SCALE: VERTICAL. NAVE) 1988 1 " = 10, HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY LIFTING EYE (TYP. OF 4) VALL JTLET PIPE ZOM FLOWKIT CHBASIN FOOT '. OF 4) CALL 48 HOURS BEFORE YOU DIG! 811 CITY OF } F RENTON Planning/Building/Public Works Dept. STORMFIL_ CARTRIC PERMANENT POOL ELEVATION CARTR SUP[ FLO CATCHBASIN (TYP. OF 4) CATION NLET UG ON WEIR WALL SECTION A —A 1-CARTRIDGE CATCHBASIN STORMFILTER DATA STRUCTURE ID N/A WATER QUALITY FLOW RATE (cfs) .0044 PEAK FLOW RATE (<1 cfs) .021 RETURN PERIOD OF PEAK FLOW (yrs) 100 CARTRIDGE FLOW RATE (gpm) 7.5 MEDIA TYPE (CSF, PERLITE, ZPG, GAC, PHS) ZPG RIM ELEVATION 32.60 PIPE DATA: I.E. DIAMETER INLET STUB N/A N/A OUTLET STUB 29.85 8" CONFIGURATION O OUTLET 5 SLOPED LID NO SOLID COVER NO NOTES/SPECIAL REQUIREMENTS: T U O Q J AN I� R-395509 W IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 RENTON COMMONS LLC 215 WHITWORTH AVE S, RENTON, WA 98057 CIVIL DETAILS m C� z O O z O DATE: 11/15/2017 FIELDBOOK: PAGE: DRAWING NO: C7.0 ,z SHEET: OF: 15