Loading...
HomeMy WebLinkAboutR-395510WIDTH AND SLOPE VARIES Ln L!7 0� co O Nt 0 W z O 75 O U z O I- z W rr BE PLANTING PER LA PLANS 3" PLUG VALVE AND C.I. VALVE BOX SEE PLANS 4" CEM. CONC. CL. 3000 ° a a 3" CSTC COMPACTED SUBGRADE NOTE: SCORING AND SPECIAL FINISH PER ARCH AND LANDSCAPE DWGS. CEM. CONC. WALK C7.1 NTS EDGE RESTRAINT WHERE PAVERS, REF. LA FOR TYPE PAVERS ARE NOT ADJACENT AND LAYING PATTERN TO STRUCTURE/WALL 1" SAND SETTING BED EXTEND BASE 6" BEYOND 5 EDGE OF PAVERS 6" DEPTH PERMEABLE BASE a. a° a. d d GEOTEXTILE, MIRAFI 140N PROOF ROLLED SUBGRADE NOTES: 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. ALL WORK SHALL BE PER PAVER MFTR'S SPECIFICATIONS. 2. EDGE RESTRAINT SHALL BE "PAVE EDGE RIGID" AND SHALL BE INSTALLED PER MFTR'S RECOMMENDATIONS. 3. PERMEABLE BASE SHALL _BF -�!7Y OF. SEATTLE�MINERAL ,AGGREGATE TYPE, 4. JOINT OPENING AGGREGATE SHALL BE PER PAVER MFTR'S SPECIFICATIONS. A 5. PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. COMPACT TO A DEPTH OF 6" TO 90%-92% OF MAXIMUM DENSITY PER WSDOT 2-03.3(14)D. OVER COMPACTED SUBGRADE SHALL BE SCARIFIED TO 8" MIN AND RECOMPACTED. 6. PLACEMENT OF PERMEABLE BASE SHALL BE PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION 2 PERMEABLE PAVE S NTS o" nvrnn nm nlnr NOTE: PUMP POWER SHALL BE PROVIDED VIA DEDICATED CIRCUIT FROM BUILDING ELECTRICAL PANEL PER ELEC. AND NEC REQUIREMENTS. BACKUP POWER SHALL BE PROVIDED BY ON SITE PORTABLE GAS GENERATOR. n4p PLAN INLET 'E a" INLET PIPE EXTERIOR CONTROL PANEL WITH ALARM AND MANUAL GENERATOR TRANSFER SWIITCH. MOUNT TO BLDG PER PLANS RIM 33.20 12" 3" PVC SCH. 80 DISCHARGE PIPING WITH REDUCER AND UNION BEFORE ELBOW \R\ ALARM ELEV. 29.50 2ND PUMP ON ELEV. 28.50 1ST PUMP ON ELEV. 28.00 p' as . PUMP OFF ELEV. 24.33 ° WET WELL BOTTOM ELEV. 23.50 • e° *SUBMERGENCE PER MFR 1. RECOMMENDATION NOTES: SECTION A 1. LIFT STATION MANHOLE SHALL BE 60" DIA. PRECAST CONCRETE, OR APPROVED EQUIVALENT & SHALL MEET H-20 TRAFFIC LOADING CRITERIA. THE PUMPS SHALL BE DUPLEX NON -CLOG PUMPS OF THE SUBMERSIBLE QUICK -DISCONNECT TYPE. THE SYSTEM SHALL BE DESIGNED TO PERMIT GROUND LEVEL REMOVAL OF PUMPING UNITS FROM THE WET WELL FOR INSPECTION OR SERVICE. 2. PUMPS SHALL BE EXPLOSION PROOF HOMA SUBMERSIBLE MODEL TP49V24/V1FN1, 230V, SINGLE PHASE, 1.7 HP, OR APPROVED EQUIVALENT, WITH SEAL PROBE AND SIZED TO OPERATE AT'111 GPM'WITH 10.5 FEET TOTAL DYNAMIC HEAD. -/5\ 3. CONTROL PANEL SHALL BE MODEL IS-WD1P-4-1022 DUPLEX CONTROL PANEL AS MANUFACTURED BY SEEWATER INC., OR APPROVED EQUIVALENT AND SHALL PROVIDE ALTERNATING SERVICE, WITH SEAL FAILURE CIRCUIT INDICATOR, 120V AC CONVENIENCE OUTLET, ALARM LIGHT AND HORN, AND ANTI CONDENSATE HEATER. DUPLEX STORM PUMP NTS Al design PLLC A CIVIL ENGINEERING COMPANY 219 First Avenue S., Suite 401 Seattle WA 98104 206 402 4644 4" DEPTH PERVIOUS CEMENT CONCRETE A 6" DEPTH PERMEABLE BASE NOTES: 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2. PROTECT PERVIOUS CONCRETE DURING CURING BY COVERING W/ PLASTIC SHEETING AND MAINTAIN PLASTIC SHEETING AND/OR OTHER PROTECTION TO ENSURE NO SEDIMENT DEPOSITION OCCURS WHILE SITE, SOILS ARE�QIS_TUR ED 3. PERMEABLE BASE SHALL BE CITY OF SEATTLE MINERAL AGGREGATE TYPE 24. 4. PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. COMPACT TO A DEPTH OF 6" TO 90%-92% OF MAXIMUM DENSITY PER WSDOT 2-03.3(14)D. OVER COMPACTED SUBGRADE SHALL BE SCARIFIED TO 8" MIN AND RECOMPACTED. 5. PLACEMENT OF PERMEABLE BASE SHALL BE PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION PERMEABLE PAVEMENT NTS WATERTIGHT CONDUIT COUPLING AND BUSHING 30" RING AND WATERTIGHT C.I. COVER. MARKED "DRAIN". OLYMPIC FOUNDRY #MH69. UPPER RAIL SUPPORT 3" CHECK VALVE, GRUNDFOS COMPRESSION FITTING INTERMEDIATE RAIL SUPPORT 8" INLET IE 26.45 SEEN ■ A 8" OVERFLOW IE 30.00 SET RAIL BRACKETS TO PROVIDE CLEAR ACCESS FROM MH OPENING 6" INLET IE 28.44 SECTION B 4. RAIL SYSTEM: PUMPS SHALL BE INSTALLED ON A RAIL -GUIDED LIFTING ASSEMBLY. BRACKETS SHALL BE MFTR'D BY HOMA OR APPROVED EQUIVALENT, EQUIPPED WITH STAINLESS STEEL PULL RODS. PIPE RAILS AND ALL MOUNTING HARDWARE AND FASTENERS SHALL BE STAINLESS STEEL. 5. LIFTING CABLE: THE STAINLESS STEEL CABLE TO RAISE AND LOWER PUMP SHALL BE OF SUFFICIENT LENGTH TO EXTEND FROM THE PUMP TO THE MANHOLE OPENING. PROVIDE A HOOK TO ATTACH THE CHAIN OR CABLE WHEN NOT IN USE. THE LIFTING CABLE SHALL BE SIZED ACCORDING TO THE PUMP WEIGHT. 6. FLOATS / PUMP CONTROLS: PUMP LEVEL FLOAT CONTROLS AND HIGH-LEVEL ALARM FLOAT SHALL BE MECHANICAL OPERATION, SEEWATER. ALL CONTROLS SHALL BE EXPLOSION PROOF, SUITABLE FOR HAZARDOUS ATMOSPHERE. CONTROLS AND COMPONENTS SHALL BE SUITABLE FOR THE PURPOSES INTENDED AND SHALL BE ACCEPTABLE TO THE CITY/STATE ELECTRICAL INSPECTOR. 7. A FLOAT MOUNTING BRACKET SHALL BE PROVIDED WITH STRAIN RELIEFS THAT SUPPORT AND HOLD THE LEVEL CONTROL CORDS. CONTINUOUS CORDS ARE TO RUN FROM PUMPS AND LEVEL CONTROLS TO THE JUNCTION BOX. SPLICES SHALL ONLY BE ALLOWED IN THE JUNCTION BOX. THE BRACKET SHALL BE FABRICATED FROM STAINLESS STEEL, AND SHALL BE ATTACHED TO THE MANHOLE WITH STAINLESS STEEL FASTENERS. 2 BID ADDENDUM # 1 3 BID ADDENDUM # 2 5 CONSTRUCTION ASI-1 NO. I REVISION 08 18 2017 SURVEYED_ 08 29 2017 DESIGNED: TTG 11 15 2017 DRAWN: TTG CHECKED: WE BY DATE APPR I APPROVED: SCALE: VERTICAL. NAVD 1988 1 " = 10' HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY m Lf) SAWCUT JOINT Ln TIE BARS @ r `14 30" O.C. O o O d d dQ T .Q 3" CRUSHED SURFACING TOP COURSE CONTRACTION/SCORE JOINT PREMOLDED JOINT FILLER. SET FILLER CEM. CONC. CL 4000 Y2" BELOW FIN. SURFACE AND SEAL 1.75" WITH ELASTOMERIC SEALANT KEYWAY ' ^ d - L / v d d - v D ti ° a D ;, d ci D+3' D O o p T T 18 (TYP) \ 3" CRUSHED SURFACING J CONSTRUCTION JOINT TOP COURSE COMPACTED SUBGRADE. NOTE: 1. D = 6" 2. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. REFER LA FOR FINISH, COLOR, AND SCORING co O O CEM. CONC. PAVEMENT NTS T rr n 40 40 MAINTAIN 6" MIN. . AP . . . . CLEARANCE OVER CRPL13:GRADE AND PROVIDE ETHAFOAM 0- CUSHION BETWEEN CRPL. i FINISHED ckf 35 CONNECT 3rj TO CB AND 8" SD GRADE IE 30.65 I . EX 12" SD PROP. 6" 30 30 IE 28.55t 8 PVC C900 CLEANOUT . . . . SD ® 2%. FIRST 8"X4" WYE WITH 4"X3 PIPE JOINT REDUCER. CONNECT TO SHALL BE ONE : 3" PUMP .DISCHARGE LINE. 25 FULL PIPE STICK 25 APPROXIMATE SOUTH OF CB - 8" WYE CONNECTION FOR LOCATION OF EX. . . . . NO JOINTS OVER STATION OVERFLOW " 52" CEDAR RIVER ' ' ' . . . . CRPL. . . . . . .\PUMP DISCHARGE . . PIPELINE (CRPL) 20 20 STORM DRAIN PROFILE SCALE: HORZ. 1" = 10' VERT. 1" = 5' R-395510 Lu IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 CALL 48 HOURS BEFORE YOU DIG! 811 CITY OF } F RENTON Planning/Building/Public Works Dept. RENTON COMMONS LLC 215 WHITWORTH AVE S, RENTON, WA 98057 CIVIL DETAILS m z O 73 2 O U z O DATE: 11/15/2017 FIELDBOOK: PAGE: DRAWING NO: C7.1 Iz SHEET: 10 OF: 15