FRAME AND VANED GRATE
3r` D 30+
5 \ S+
OR IT
\L ONE 93 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
a/
#3 BAR EACH CORNEF
#3 BAR EACH SIDE
#3 BAR EACH ....
PRECAST BASE SECTION
#3 BAR EACH CORNER
18" MIN.
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
12"
PLAIN CONCRETE
ALL METAL PIPE
15"
CPSSP*
12"
(STD. SPEC. 9-05.20)
SOLID WALL PVC
15"
(STD. SPEC. 9-05.120))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
NOTES
1. As acceptable altematives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
PUBLIC WORKS CATCH BASIN TYPE 1 STD. PLAN - 200.00
DEPARTMENT
�t:N,tp MARCH 2O08
4'MIN
i' DEPTH 2"- 4'ROCK
3
2' SETTLING DEPTH . r
1.F SEDIMENT STORAGE
1' DEPTH 3/4" - 1-112" WASHED GRAVEL
CROSS SECTION
NTS
V OVERFLOW DEPTH
OUTFLOW
CHANNELIF
-- - CONSTRUCTED BY
g EXCAVATION.
&MAX
-IiO FILTER FABRIC FENCING
NOTE:
MAY BE CONSTRUCTED BY EXCAVATION
OR BY BUILDING A BERM
��Y o PUBLIC WORh� SEDIMENT TRAP STD. PLAN - 211.00
DEPARTMENT
P�NTp$ MARCH 2O08
NOTES
TOP
1. This frame is designed to accommodate 20" x 24" grates or
covers
2. Provide two holes in the frame that are vertically aligned with Ithe
grate or cover slots. Tap each hole to accept
24 1/4"
a 5/8" - 11 INC x 2"alien head cap screw.
11fi
Location of bolt down holes varies among different
y�
manufacturers.
WPM
3. Refer to Standard Specification 9-05.15(2) for additional
r
r
requirements.
SECTION
RECESSED ALLEN
HEAD CAP SCREW ,�
7i_ /8"_I 1/8" 5/8" - 11 NC x 2" \(WWI- IIIBII
i -
y ISOMETRIC VIEW
1 5/8" -I-
\ FRAME
r w
z v2"
SECTION
BOLT -DOWN DETAIL
DETAIL B SEE NOTE 2
iy
PUBLIC WORKS RECTANGULAR FRAME STD. PLAN - 204.00
DEPARTMENT
MARCH 2O08
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS.
6' MAX.
wI
POST SPACING MAY BE INCREASED
TO 8' IF WIRE BACKING IS USED
2"x2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED '
FILTER FABRIC
i li III �
MINIMUM 4"x4"TRENCH
BA.KFILL TRENCH WITH
NATIVE SOIL ,
\ / D
D2"x4" WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
30-100SIEVESIZE(0.60-1.11MM)FORSILTFILM
AOS(ASTM D4751)
50-100 SIEV E SIZE (0,30-0.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D491)
0.025EC^-1 MINIMUM
GRAB TENSILE STRENCHT(ASTM D4632)
180LBS. MIN. FOR EXTRASTRENGH FABRIC
100LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRAB TENSI LE ELONGATION ASTM D4632
30%MAX.
ULTRAVIOIATE RESISTANCE(ASTM D435S)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3A. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4s SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.6 IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
STD. PLAN - 214.00
�. PUBLIC WORD SILT FENCE
DEPARTMENT MARCH 2008
nOnn WA fl 0 nn
design PLLC
A CIVIL ENGINEERING COMPANY
219 First Avenue S., Suite 401
Seattle WA 98104
206 402 4644
2 BID ADDENDUM # 1
3 BID ADDENDUM # 2
5 CONSTRUCTION ASI-1
NO. I REVISION
e
21/2"
BOLT -DOWN SL(
DETAIL AND NOl
TOP "'
SECTION (B)i
NOTES
1 Provide two slots in the cover that are vertically aligned
with the holes in the frame.Location of bolt -down slots
varies among different manufacturers.
�
a Alternative reinforcing designs are acceptable in
lieu of the rib design.
3. Refer to Standard Specification 9-05.15(2) for additional
requirements
39" R - SEE NOTE 2
4, For Frame details, see City of Renton
SECTION
Standard Plan 204.00.
5
3/4" 3/4"
5/8"
9" �-{ 3/4" DIAM. HOLE - 1 1/4"
112" DIAM. HANDLE
518
SECTION (�) I
L i _
BOLT"DOWN SLOT DETAIL
SEE NOTE 1
ISOMETRIC
try PUBLIC WORKS RECTANGULAR SOLID STD. PLAN - 204.10
DEPARTMENT METAL COVER
MARCH 2O08
EX�S"\NG ,0 PO
R=25'MIN.
DRIVEWAYS SHALL BE PAVED TO THE EDGE
OF R-O-W PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO AVOID
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
ENTRANCE BE CROWNED SO THAT
\ RUNOFF DRAINS OFF THE PAD
�O.
INSTALL DRIVEWAY CULVERT IF THERE D
IS A ROADSIDE DITCH PRESENT, AS
PER CITY ROAD STANDARDS
4"-8" QUARRY SPALLS /
GEOTEXTILE /
12"MIN. THICKNESS --�. �a PROVIDE FULL WIDTH OF
NOTES INGRESS/EGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRAB TENSILE STREBNGTH(ASTM D4751) 1200
PSI MIN.
GRAB TENSILE ELONGATION(ASTM D4632)
30%MAX.
MULLEN BURST STRENGTH ASTM D3786-80A)
140OPSIMIN.
ADS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
STD. PLAN - 215.10
PUBLIC WORKS STABILIZED
DEPARTMENT CONSTRUCTION ENTRANCE
�sNTp MARCH 2O08
08Q 18 2017 SURVEYED_
DU 29 2017 DESIGNED:
11 15 2017 TTG
DRAWN:
TTG
CHECKED:
WE
BY DATE APPR APPROVED
O 4 �
of
U
❑ 0
o �
a
O
LU
LU
F \
W \
Z
Z
of
0
Z)
0
LLLJ
DD
D D
OUTFACE TO STREAM DUMP ND POLLUTI
L I
TOP
NOTES
1. Provide two slots in the grate that are vertically aligned with the holes in the frame.
Location of bolt -down slots varies among different manufacturers.
Refer to Standard Specification 9-05.15(2) for additional requirements.
9, The thickness of the grate shall not exceed 1 5/8".
4. Unless otherwise specified, vaned grates shall be used with standard frame
in the travel way, gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
a
0
�e0
0C-
ISOMETRIC
D
SLOT - SEE DETAIL
\ AND NOTE 1
3/8" (9mm) RECESSED
LETTERING
1 114"
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
��Y o PUBLIC WORKS RECTANGULAR STD. PLAN - 204.40
DEPARTMENT HERRINGBONE GRATE
MARCH 2O08
- � 5" MAX.
DRAINAGE GRATE TRIM
GRATEFRAME
o a
° o
SEDIMENT AND DEBRIS
OVERFLOW BYPASS
D D
BELOW INLET GRATE DEVICE
FILTERED o
WATER
o A A
A A
SECTION VIEW
DRAINAGE GRATE
- RECTANGULAR GRATE SHOWN
BELOW INLET GRATE DEVICE
RETRIEVAL SYSTEM (TYP.)
OVERFLOW BYPASS(TYP.)
ISOMETRIC VIEW
NOTES
I. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service.
3. The BIGD shall have a built-in high -flow relief system (overflow bypass).
(3, The retrieval system must allow removal of the BIGD without spilling the collected material.
4. Perform maintenance in accordance with Standard Specification 8-01.3(15).
tity O
PUBLIC WORKS CATCH BASIN FILTER PLAN - 218.30
�= $ DEPARTMENT
�1 N tp MARCH 2O08
CALL 48 HOURS
BEFORE YOU DIG!
811
SCALE:
1" = 10, HORIZONTAL: NAD 1983/1991 CITY OF
RENTON
ONE INCH DATU M
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
LO
T
0
I
T
E1
�J
J
T
rr
R-395512 W
V )
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
RENTON COMMONS LLC
215 WHITWORTH AVE S, RENTON, WA 98057
COR STD DETAILS
m
Cn
Z
O
5
2
O
U
Z
O
DATE:
11/15/2017
FIELDBOOK:
PAGE:
I-_
DRAWING NO:
C7.3
,z
SHEET: OF:
DF: 15