Loading...
HomeMy WebLinkAboutT-404364GROUND STUD (TYP) (SEE NOTE 4) z O 0 z M M v N N O LL LL O x 0 LU LO z I I HEADED ANCHOR SHEAR STUD - 3/8" (IN) x 3" (IN), 10 COUNT STUDS EVENLY SPACED AROUND FRAME i Q Equipment Grounding Conductor O2 Copper Solderless Crimp Connector 0 Equipment Bonding Jumper < Foundation < See Contract for conduit size and number 48" U 42" 36" <4> SEE HINGE DETAIL 1/8" GAP B BETWEEN LIDS 3a 0 w Q CO J i0 Z LU tv > w to 0 C0 m M • -------------------- _ a DIAMOND PATTERN (SEE NOTE 2) i i I I 1" 4 STUDS EVENLY SPACED (TYP.) PLAN VIEW LOCKING LID STANDARD DUTY JUNCTION BOX 3/16" TOP OF SOIL SURFACE #5 HOOP WITH 8" (IN) LU o OVERLAP - 2 TIES 0 m O v \ 0 7_CO z z �L� w N = 1— 0 rr 0 Y U 3/16 1 1/2 m FRAME - L 1 3/4" (IN) x - z 1/2" (IN) x 3/15" (IN) 0 (TYP.) 3/16 1/4 k WWF - TIED IN 2 PLACES TO HEADED ANCHOR SHEAR STUD (SEE NOTE 10) 3/8" (IN) x 3" (IN) HEADED ANCHOR SHEAR STUD - WELDED TO LIP PLATE (SEE NOTE 10) - CL SEE NOTE 8 OI I SEE HANDLE DETAIL I- 1 I--� ------- L", • s I I J (TVP.) 3/16 1 1/2 Al 19" 19" COVER MARKING DETAIL NOTES z 1" (TYP.) ^ 1- (TYP,) 1. All box dimensions are approximate. Exact configurations vary among manufacturers. 2. Minimum lid thicknesses are shown. Junction Boxes installed in sidewalks, walkways, and ITI shared-use paths shall have a slip -resistant coating on the lid and lip cover plate and shall be installed with the surface flush with and matched to the grade of the sidewalk, walkway, or shared -use path. The non -slip lid shall be identified with permanent markings on the 4 4 4 O 4 O 1/4" CLEAR underside, indicating the type of surface treatment (see Contract Documents for details) and O-n---a--Q--o5Z the year of manufacture. The permanent marking shall be 1/8" (in) line thickness formed with gyp" I T S_ ALL AROUND a mild steel weld bead and shall be laced prior to hot -di p p p galvanizing. 0�4�Q�vOvO SEE NOTE 8 3. Lid support members shall be 3/16" (in) min. thick steel C, L, or T shape, welded to the frame. Exact configurations vary among manufacturers. 4. A 114-20 NC x 3/4" (in) S. S. ground stud shall be welded to the bottom of each lid; include (2) S. S. nuts and (2) S. S. flat washers. 5. The hinges shall allow the lids to open 180•. 6. Bolts and nuts shall be liberally coated with anti -seize compound. 7. Connect Equipment Bonding Jumper to ground stud on lid. As an alternative to the ground stud connection, the Equipment Bonding Jumper shall be attached to the front face of the hinge pocket with a 5/16-20 NC x 3/4" (in) S. S. bolt, (2) each S. S. nuts, and (2) each S. S. flat washers. Equipment Bonding Jumper shall be #8 AWG min. x 4' (ft) of tinned braided copper. 8. The System Identification letters shall be 1/8" (in) line thickness formed by a mild steel weld bead. See Cover Marking detail. Grind off diamond pattern before forming letters. See Standard Specification 9-29.2(4) for details. 9. See the Standard Specifications for alternative reinforcement and class of concrete. 10. See Standard Plan J-40.10 for Welded Wire Fabric and Headed Anchor Shear Stud attachment details. 11. Capacity - conduit diameter = 24" (in) 12. Lid Bolt Down Attachment Tab provides a method of retrofitting by using a mechanical process in lieu of welding. Attachment Tab shown depicts a typical component arrangement; actual configurations of assembly will vary among manufacturers. See approved manufacturers' shop drawing for specifics. 13. Unless otherwise noted in the plans or approved by the Engineer, Junction Boxes, Cable Vaults and Pull Boxes shall not be placed within the sidewalk, walkway, shared use path, traveled way or paved shoulders. All Junction Boxes, Cable Vaults, and Pull Boxes placed within the traveled way or paved shoulders shall be Heavy -Duty. 14. Distance between the top of the conduit and the bottom of the Junction Box lid shall be 6" (in) min. to 8" (in) max. for final grade of new construction only. See Standard Specification 8-20.3(5). Where adjustments are to be made to existing Junction Boxes, or for interim construction stages during the contract, the limits shall be from 6" (in) min. to 10" (in) max. See Standard Specification 8-20.3(6). HEX COUPLING NUT (TYP.) - SEE DETAIL "C" 42" 3" (TYP.) TOP OF BASE COURSE 1/2" (IN) STEEL LIFT HOLE - 3/16" C COVER PLATE V (IN) - 2" (IN) TOP OF PAVED (TYP.) DIAM. SURFACE ° • 5 3 s 2 1 W LU I, to z 2" MIN. #5 HOOP WITH ? 8" (IN) OVERLAP - 1„ (TYP.) O 2 TIES ° MIN. •D•° ° 4 m uj OU ?LU a z u_ 1 2 3„ > CRUSHED SURFACING (BASE COURSE OR TOP COURSE) -2 O PER STANDARD SPECIFICATION 9-03.9(3)',', ° N O PVC CONDUIT GRS CONDUIT SECTION AO LID SUPPORT - 3/16" (IN) MIN. THICK f-- 1/2" (IN) STEEL COVER PLATE GROUND STUD WITH 2 NUTS AND 2 WASHERS (TYP.) (SEE NOTE 4) EQUIPMENT BONDING JUMPER (TYP.) (SEE NOTE 7) HEX COUPLING NUT -- S. S. 5116 NC x 7/6" (IN) WITH S. S. 5/16 NC x 3/4" (IN) BOLT AND 4 EACH S. S. WASHERS (TYP.) DETAIL O 30" 20" INSIDE WIDTH OF FOUNDATION GROUND STUD -\ ALTERNATE LOCATION FOR ATTACHMENT OF EQUIPMENT BONDING JUMPER (SEE NOTE 7) (TYP SECTION O CONDUITS NOT SHOWN HINGE DETAIL 2" 1" i 5/8" (IN) x 1" (IN) i VERTICAL SLOT a i IV I 2" BOLT PLATE CHANNEL 3" WELDED WIRE FABRIC (TYP.) (WWF) 44-W2.9 (6 GAGE) (SEE NOTE 9) ° WELDED WIRE HOOP (TYP.) W2.9 (6 GAGE) (SEE NOTE 9) LOCKING LID STANDARD DUTY JUNCTION BOX TYPE 8 STANDARD PLAN J-40.30-04 SHEET 1 OF 2 SHEETS APPROVED FOR PUBLICATION Carpenter, Jeff Apr 28 2016 3:15 PM STATE DESIGN ENGINEER T Washington State Department of Transportation 1/2" (IN) STEEL 5" J HANDLE STOP - COVER PLATE 6" (IN) x 3" (IN) x 1/4" (IN) 3A" (IN) DIAM. HOLE (TYP.) I I ------------------- S. S. PIN WITH SNAP RING GROOVE (TYP.) TOP VIEW - S. S. FLAT WASHER (TYP.) HANDLE STOP S. S. SNAP RING (TYP.) 1/2" (IN) STEEL v COVER PLATE (TYP.) 1/4 1" (IN) x 1" (IN) x 1/4" (IN) (TYP.) HANDLE - BENT 1/2" (IN) STEEL ROD, FLUSH WITH LID FRONT VIEW HANDLE DETAIL 1.1 1 112" 1 3/8" 2 1/4" 1/2 - 13 x 1 1/2 S. S. PENTA HEAD BOLT 3/16 1 1/2 AND 1/2" (IN) S. S. FLAT WASHER i 3l18" LID SUPPORT - 3/16" (li) MIN. THICK 1/2 - 13 x 1 1/2 S. S. PEN TA HANDLE - SEE DETAIL 5/8" (IN) x 1" (IN) 1 3/8" (IN) DIAM. HOLE FRAME - L 1 3/4" (IN x HEAD BOLT AND 1/2" (IN) 3/16 VERTICAL SLOT S. S. FLAT WASHER 1/2" (IN) STEEL COVER PLATE 1/2" (IN) STEEL COVER PLATE 1/2" (IN) x 3/16" (IN) _ (TYP.) = SHOWN CUT AWAY FOR CLARITY FRAME - L 1 3/4" (IN) x 3/16 3/16 1/2' (IN) x 3/16" (IN) BOLT PLATE LID SUPPORT - a a CHANNEL 1/4 3/16" (IN) MIN. THICKNESS 1 3/16 1 1/2 (TYP') 3116 a 6' (IN)HANDLx 3' (N) x 1/4" (IN) BOLT PLATE CHANNEL - a SLOTTED S. S. CHANNEL WITH S. S. CHANNEL NUT WELD TO STEEL COVER PLATE a a 1 a AND SPRING LutauNu LiD STANDARD v WWF - TIED IN 2 PLACES TO HEADED ANCHOR 3/8" (IN) x 3" (IN) HEADED 1/4 ° ' DUTY JUNCTION BOX SHEAR STUD (SEE NOTE 10) a ANCHOR SHEAR STUD - 518" (IN) x 1" (IN) TYPE 8 a WELDED TO LIP PLATE HORIZONTAL SLOT ° (SEE NOTE 10) ° STANDARD PLAN J-40.30-04 a a SLOTTED S. S. CHANNEL X SHEET 2 OF 2 SHEETS WITH S. S. CHANNEL NUT AND SPRING APPROVED FOR PUBLICATION c rpe"ter, Jeff DETAIL D Apr 282016315 PM 3.. DETAIL D . Washington State Department of Transportation " 0 36 STATE DESIGN ENGINEER O ISOMETRIC VIEW T • U H U) 0-1 W O Z Z W V/ o Z J O7 Z O L� N Ir H N C9 Q li.l 0 Z � ULLI U LLI It a. 0 0_ 0_ Q W I-_ c Z 0 0 E o c -0 6 >� N L m M 3 0_ 7 N � Z o IY O L)0.S W n/ LL N j w w = -O O v N m W D_ W V) dj 0 m m v Y U y U in O Z V Z_ U Z Z OF Z LU I.L Z 3 LL NQ I.L = LU W = ? O J Q W o Z O_ F_ 0 LL (n LL. ~ U Z 0 U 0 W Z W ' Q 0 J Z Z Y Z O IlIll— LU LL SHEETA0O/SIG-16 OF: 70 JOB NO.: 17534 DWG: DETS-PDFS-SH 35