Loading...
HomeMy WebLinkAboutT-404365Y N 3.1 3 Q Z g 0 Q O O N O cV 00 cV O t7� 3 v Lri r� 2 N I N LL_ I N W 0 i U 0 t` O U 0) I 41 a) fn C O Q 0) 0) t3 J` d rn Fn a) O 0) O O O O t7� �U O 4 t` fn J` O N C 0) > 0 C O C 0) L LO z O Z W ry TO POWE SOURCE I 1 5 8 4 8 24 6 43 8 RMC PVC APPLICATION APPLICATION KEY SERVICE NEUTRAL O SERVICE GROUND 0 GROUNDING ELECTRODE CONDUCTOR ® BONDING JUMPER O GROUNDING BUSHING (TYP. ALL RMC CONDUIT TERMINATIONS) © GROUNDED NEUTRAL BUS (COPPER) O7 SERVICE ENCLOSURE ® EQUIPMENT GROUNDING CONDUCTOR O JUNCTION BOX ❑ 0 r U J m Of ❑ SUPPLEMENTAL GROUND 10 SUPPLEMENTAL GROUND 1O w w O w w RIGID PVC CONDUIT (PVC) APPLICATION GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION GROUND DETAILS 10 ELECTRICAL LOAD SUPPORT (LUMINAIRE POLE AND TRAFFIC SIGNAL POLE) 21 TO GROUNDING TERMINAL OR CONNECTION TO 11 COPPER SOLDERLESS CRIMP CONNECTOR EQUIPMENT GROUNDING SYSTEM 12 GALVANIZED STEEL RIGID METAL CONDUIT (RMC) 22 BONDING JUMPER ATTACHED TO BOX WALL 13 RIGID PVC CONDUIT (PVC) COUPLING NUT 23 BONDING JUMPER ATTACHED TO BOX LID(S) 14 O OPTION A - 10' RMC WITH FIELD BEND GROUND STUD. # 8 AWG (MIN.) x 4' (FT) TINNED APPROVED ADAPTER FITTING BRAIDED COPPER. GROUNDING BUSHING 24 END BELL BUSHING OPTION B - 10' RMC (TYP• ALL NON-METALLIC CONDUIT TERMINATIONS) GS FACTORY ELBOWS 5 CODE SIZED PVC APPROVED ADAPTER FITTING GS COUPLING 26 HIGH -DENSITY POLYETHYLENE CONDUIT (HDPE) GROUNDING BUSHING NON-METALLIC CONDUIT (PVC) SCHEDULE 80 15 GROUND ROD 28 BOX LID(S) GROUND STUD 16 EDGE OF FOUNDATION, POLE OR SERVICE SUPPORT 29 CABLE VAULT 17 CLAMP 30 PULL BOX 18 JUNCTION BOXORB DRAIN TILE WITH APPROVED 31 ITS CABINET 19 CONCRETE CODE SIZE RMC 32 EDGE OF FOUNDATION 20 TO SERVICE NEUTRAL BUS 33 TRAFFIC SIGNAL CABINET 1O Required to supplement equipment grounding for luminaire standards with direct burial aerial feeds, or where required in the plans ORequired at all service and separately derived systems O3 Type D service cabinet shown. Use this concept for Type E cabinet or transformer. Type D service cabinet shall be installed on lower surface of foundation only. Type B service cabinet and transformer cabinet shall be installed on raised surface of foundation only. 4O Type B modified service cabinet O5 Grounding electrode conductor and equipment grounding conductor shall not be routed through lug on grounding bushing. SERVICE GROUND O2 DETAIL O SERVICE GROUND O2 DETAIL O TFTYFE D SERVICE CABINET CONTINUED ON SHEET 2 CONTINUED ON SHEET 2 NOTES 1. If parallel circuits of different sizes are contained in one conduit, the size of the grounding conductor shall be determined on the basis of the largest conductor. Only one grounding conductor is required for each conduit, regardless of the number of circuits contained. 2. Service ground per serving utility require- ment. If the utility uses aluminum service conductors, an approved AI-Cu pressure - type ground connector shall be used to secure the service neutral to the copper neutral bar In the Service enclosure. Except for the above, all grounding conductors shall be copper. 3. Equipment grounding conductors and grounding electrode conductors shall be sized in accordance with the National Electrical Code (No. 8 minimum). 34 CABINET GROUNDING BUSS (COPPER) - RIGID PVC OUTERDUCT WITH PVC OR PE INNERDUCT 36 GALVANIZED STEEL RIGID METAL CONDUIT OUTERDUCT WITH PVC OR PE INNERDUCT TYPICAL 37 O EQUIPMENT GROUNDING CONNECTION POINT IN CABLE VAULT OR PULL OXBETWE BETWEEN TESERVIICES GROUNDING DETAILS 38 DETECTABLE UNDERGROUND WARNING TAPE. COIL 2' INSIDE CABINET, CABLE VAULT, OR PULL BOX STANDARD PLAN J-60.05-01 39 TRANSFORMER CABINET SHEET 1 OF 3 SHEETS 40 GROUNDING CONDUCTOR NON -INSULATED (FROM REINFORCING CAGE) 41 BOX FRAME BONDING ATTACHMENT POINT APPROVED FOR PUBLICATION 42 GROUND LUG WELDED TO CABINET WALL (WI TINNED COPPER BUSS) .r� Carpenter, Jeff �W r % Jul 21 2016 8:33 AM 43 CABINET MAIN BONDING JUMPER STATE DESIGN ENGINEER 44 ITS CAMERA, RAMP METER, TRAFFIC DATA STATION, HIGHWAY ADVISORY RADIO Washington State Department of Transportation 45 UNGROUNDED CABINET NEUTRAL BUSS (COPPER) -" SEE STANDARD PLAN J-10.10 15 6' - 0" MIN. 15 RIGID PVC CONDUIT (PVC) APPLICATION TrTYP`EFDJ SERVICE CABINET I lnJ 15 SEE STANDARD PLAN J-10.10 6'-0"MIN. 15 GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION D 15 6'-0"MIN. 15 RIGID PVC CONDUIT (PVC) APPLICATION SERVICE GROUND 2O 15 DETAIL O SERVICE GROUND O2 15 6' - 0" MIN. 15 GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION 15 DETAIL O SEE KEY ON SHEET 1 FOR PARTS cosign TYPICAL GROUNDING DETAILS STANDARD PLAN J-60.05-01 SHEET 3 OF 3 SHEETS APPROVED FOR PUBLICATION Carpenter, lea Ad 212016 833 AM STATE DESIGN ENGINEER Adft Washington State Department of Transportation CONTINUED FROM SHEET 1 COMBINED GALVANIZED STEEL RIGID METAL CONDUIT (RMC) AND RIGID PVC CONDUIT (PVC) APPLICATION CONTINUED —FROM SHEET 1 RIGID PVC CONDUI (PVC) APPLICATIC CONTINUED FROM SHEET GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION A 31 ! 45 ITS - COMBINED ! ! 31 I i ITS -COMBINED GALVANIZED STEEL I ! GALVANIZED STEEL ! RIGID METAL CONDUIT (RMC)AND I ITS - COMBINED GALVANIZED STEEL 5 19 15 F,•_•1••_••_� RIGID METAL CONDUIT RIGID PVC CONDUIT (PVC) APPLICATION. 1.— RIGID METAL CONDUIT (RMC) AND RIGID (RMC) AND RIGID PVC FIBER OPTIC CABLE ONLY, PVC CONDUIT (PVC) APPLICATION CONDUIT (PVC) NO METALLIC CONDUCTORS APPLICATION A ITS - GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION TOP OF PAVEMENT 38 OR EXISTING GROUND (2 8 36 SECTION OA FROM DIFFERENT SERVICE 2 TOP OF PAVEMENT __. _ OR EXISTING 38 GROUND NT FROM DIFFERENT SERVICE 13)SHOWN 6 OR 27 POSSIBLE SECTION O "SEE CONTRACT PLANS 41 LJ L J 41 �aJ ITS GALVANIZED STEEL RIGID LJ �29, j v I i !! 31 r FRONT \\v 3 s 19 15 TYPICAL GROUNDING DETAILS METAL CONDUIT RMC APPLICATION FIBER OPTIC CABLE ONLY - NO METALLIC CONDUCTORS I ITS -GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION STANDARD PLAN J-60.05-01 4 8 4 9 SHEET 2 OF 3 SHEETS 40 40 APPROVED FOR PUBLICATION ......._ ..............._........ _.. Carpenter, Jeff Jul 212016 8:33 AM $ 44 $ STATE DESIGN ENGINEER Washington State Department of Transportation MAP 23 41 28 22 11 T 404365 • U W W O Z Z W V/ o Z_ H J L� Z O U L� t"1 N N H � Q 3 W w 0 j a Q W Q c Z 0 O E.2 o 2 • c w N N rn o N LLI m d~ (N J Z 0 O LU LL > .L toa v� Q9LLI N O � a W dj m v Y U - O Z V Z_ U Z0 Q Z OW Z LU = N LL LU = ? O a 0 Z O_ U LL (n LL V Z ULU W Z Q 0 J a Z 0 Z Y 0 U) I— Z NW LL SHEET61/SIG-17 OF: 70 JOB NO.: 17534 DWG: DETS—PDFS—SH 35