Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-404366
Y U) W Q Z g Q r s— O N O N 00 N O am 3 U] N I In LL_ 0 In I U) 0 0 I` 0 U () L I +, 0) U) C 6 CL 0) In 0 L CL rn U) 0) s` rn a) 0 U) a To f '.f 6 3 i I 11 12 1 2 3 I I 1 21 KEY 1 CENTER PIPE 3 0 SIDE MOUNT 11 CHASE NIPPLE 4 TYPE A - PEDESTRIAN 12 O3 NIPPLE TYPE H - VEHICLE ® SERRATED ELBOW 13 SERRATED OR FLANGED ELBOW © REAMED TEE WITH SET SCREW 0 REAMED ELBOW WITH SETSCREW �8 BRONZE TERMINAL COMPARTMENT WITH: 0 eGASKETED COVER •FASTENERS • WIRE LEADS *MOUNTING SADDLE FOR SIDE MOUNTS ON ROUNDITAPERED POLES - OMIT SADDLE ON 2 MULTI -SIDED POLES j e 1/4" (IN) DIAM. DRAIN HOLE e 12-POSITION TERMINAL STRIP e WIREWAY FOR SIDE MOUNTS O9 BRONZE COLLAR - 4 1/4" (IN) I.D. OFFSET OPENING W/SET SCREWS 10 ORNAMENT CAP 11 NEOPRENE GASKET 12 WASHER 13 CONDUIT LOCKNUT 14 TYPE E HINGE CLAMSHELL MOUNT - LEFT OR RIGHT, SEE CONTRACT G 15 FASTENER WITH SPACER - e 1/2" (IN) LAG SCREWS ON WOOD POLE g e 1/2" (IN) BOLTS TAPPED TO METAL POLE 16 FLATHEAD SOCKET BOLT 17 1/2" (IN) INSERT HOLE FOR EXTERNAL WIRE ENTRANCE (REQUIRED ON TIMBER POLE MOUNTING ONLY) 18 TERMINAL BLOCK AND PHENOLIC TAG 19 INSULINER - 1" (IN) MIN. DIAM. HOLE 20 SIGNAL HEAD WITH BACKPLATE 21 FIELD DRILL POLE AND INSERT AN INSULINER TOP MOUNT OR SIMILAR DEVICE TO PROTECT CONDUCTORS 2© SIMILAR TO ®WITH BRONZE INTEGRAL COLLAR TYPE D - PEDESTRIAN - OFFSET BRONZE COLLAR TO FRONT 23 1/2" (IN) DIAM. x 3" (IN) LONG BOLT WITH WASHER OR VEHICLE (SHOWN) -• OFFSET BRONZE COLLAR TO BACK TIIIIIIIIIIIIIIIIIIIIIIIi 0 366 SIDE MOUNT TYPE B - PEDESTRIAN TYPE K -VEHICLE TYPE E MOUNTING DETAILS I I I TOP MOUNT TYPE C - PEDESTRIAN TYPE F - VEHICLE �f `.% -•-•-•-•-•-•-SDI -- - - - - - ,- ----------- PEDESTRIAN HEAD SIDE MOUNT (LEFT SIDE SHOWN) TYPE E - COUNTDOWN LED PEDESTRIAN HEAD NOTES 1. See Contract for head type, mounting height, and orientation. 2. All nipples, fittings, and center pipes shall be 1 1/2" (in) diameter. 3. Install neoprene gasket inside head when flanged elbows are supplied. 4. Extend wire sheath a minimum of 1" (in) inside all signal and sign housings and terminal compartments. 5. Apply bead of silicone to the serrated ring and around the perimeter of all top openings prior to installation of fittings. 6. See Standard Specification 9-29.16 for backplate requirements. Where required, prismatic sheeting shall be applied in accordance with the manufacturer's recommendations. The application surface of the backplate shall be cleaned, degreased with isopropyl alcohol, and dried prior to application of the sheeting. 7. Drill a 1/4" (in) drain hole in the bottom of each signal display assembly, and one in the bottom of each pedestrian head. When signal display assembly is mounted horizontally, drill a 1/4" (in) drain hole at the lowest point of each section of the signal assembly. SIGNAL HEAD MOUNTING" DETAILS N POLE AND POST TOP MOUNTINGS STANDARD PLAN J-75.10-02 SHEET 1 OF 1 SHEET APPROVED FOR(�,,UBBLI ATIPyr Jul 10 2015 7:19 AM STATE DESIGN ENGINEER_.,518 MAP Washington State Department of Transportation 6 w LL w J in 0 m KEY O END CAP O2 1 112" (IN) DIAM. CONDUIT LOCKNUT O3 1 1/2" (IN) DIAM. CHASE NIPPLE ARM MOUNT ® STEEL WASHER TYPE L O5 NEOPRENE GASKET © BRONZE SERRATED ELL FITTING WITH: e 3/8" (IN) STAINLESS STEEL THROUGH BOLT AND NUTS e THREE STAINLESS STEEL SET SCREWS AT SLIPFITTER CONNECTION e THREE ALLEN HEAD STAINLESS STEEL SET SCREWS AT CONDUIT NIPPLE CONNECTION O7 SERRATED RING WITH PINS ® HEX LOCKNUT WITH: e TWO ALLEN HEAD STAINLESS STEEL SET SCREWS *PIN RECEPTACLES O9 1 1/2" (IN) DIAM. CONDUIT NIPPLE 10 1 112" (IN) DIAM. HEX LOCKNUT 11 MOUNTING ASSEMBLY 12 BRONZE ELEVATOR PLUMBIZER WITH 3/8" (IN) STAINLESS STEEL THROUGH BOLT, WASHERS, AND TWO NUTS 13 ALUMINUM ARM WITH SET SCREW 14 SLOTTED TUBE WITH CLOSURE STRIP 15 2 1/2" (IN) I.D. MIN, TUBE CLAMP 16 INTERNALLY THREADED CLAMP ASSEMBLY WITH: • TWO SET SCREWS • 1/2" (IN) x 0.045" (IN) STAINLESS STEEL BANDS • 7/16" (IN) SCREW BUCKLES WITH SWIVELS, NUTS, AND WASHERS • BAND CLIPS WITH ALLEN HEAD STAINLESS STEEL SET SCREWS 17 BRONZE MESSENGER HANGER WITH: e 1/2" (IN) DIAM. J-BOLTS e CABLE LOCK BAR e RIVET e COTTER KEY 18 BRONZE INTERNALLY THREADED WIRE ENTRANCE WITH: e BUSHING INSERT OR RUBBER GROMMET *ALLEN HEAD STAINLESS STEEL SET SCREW 19 BRONZE BALANCE ADJUSTER (WHERE REQUIRED) 20 MULTI -HEAD MOUNTING ASSEMBLY 21 LOWER ARM ASSEMBLY © SERRATED RING WITH NO PINS 23 SERRATED WASHER 24 1 1/2" (IN) DIAM. SERRATED OR FLANGED ELBOW 25 CENTER SUPPORT WITH 1 1/2" (IN) DIAM. HUBS WITH COVER AND GASKET 26 1 1/2" (IN) DIAM. SERRATED COUPLING 27 1 1/2" (IN) BREAKAWAY TETHER ASSEMBLY WITH OPTIONAL EXTENDER BAR 28 SERRATED CROSS w x U H w LL } in J O U } m i » 27 SPAN WIRE TYPE P (1 HEAD) ARM MOUNT TYPE LE Im 13 ARM MOUNT TYPE N SPAN WIRE TYPE P-5S (TYPE P WITH 5-SECTION HEAD) ARM MOUNT TYPE M ARM MOUNT TYPE M-SS (TYPE M WITH 5-SECTION HEAD) HOUSING FIXTURE CONNECTION DETAIL SPAN WIRE TYPE Q (2 HEADS) TYPE R (3 HEADS) TYPES (4 HEADS) NOTES 1. Type M mounting shall have "O" ring groove and seal on top and bottom of signal attachment. 2. Type M mounting for conventional heads shall have a 2" (in) diameter opening at the signal attachment. 3. Type M mounting for optically programmed heads shall have a 3 1/2" (in) diameter opening at the signal attachment. 4. Type N mounting with optically programmed heads shall be installed with 14" (in) nominal arms. 5. See Standard Plan J-75.30 for tether wire and backplate requirements. 6. Apply bead of silicone around the perimeter of all top end Cap openings prior to installation of the end cap assembly. 7. See Standard Specification 9-29.16 for backplate requirements. Where required, prismatic sheeting shall be applied in accordance with the manufacturer's recommendations. The application surface of the backplate shall be cleaned, degreased with isopropyl alcohol, and dried prior to application of the sheeting. 8. Drill a 1/4" (in) drain hole in the bottom of each signal assembly. When signal display assembly is mounted horizontally, drill a 1/4" (in) drain hole at the lowest point of each section of the signal assembly. NOTE: BACKPLATES NOT SHOWN FOR CLARITY SIGNAL HEAD MOUNTING DETAILS - MAST ARM AND SPAN WIRE MOUNTINGS STANDARD PLAN J-75.20-01 SHEET 1 OF 2 SHEETS APPROVED FOR PUBLICATION Carpenter, Jeff Jul 10 2015 7:18 AM STATE DESIGN ENGINEER s'n WO Washington Stare Department of Transportation NOTE: BACKPLATES NOT SHOWN FOR CLARITY SIGNAL HEAD MOUNTING DETAILS - MAST ARM AND SPAN WIRE MOUNTINGS STANDARD PLAN J-75.20-01 SHEET 2 OF 2 SHEETS APPROVED FOR PUBLICATION Carpenter, Jeff x!' Jul 10 2015 7:18 AM STATE DESIGN ENGINEER I n T Washington Stare Department of Transportation • U H W W O Z Z W Z r � J Z 0 U N 2 U_0 of H N Q W Q Z � 0 i It a 0 0 0 Q 0 D_ D_ Q W a c Z 0 0 E o c �rL3� 6 >C CO N m M D_ 7 (N Z o N� LL O U W n/ LL N .j w a 1 w 0S ' -O O v N m W CL W N dj 0 m m a Y U U (n O Z V Z_ U ZR Q Z F Z LU Z = 3 LL = 0 LLI W 2 ? O J F_ W 0 Z O U LL 0 LL ~ U Z 0 0 0 W Z W ' Q 0 J Q Z Y Z O in Z LLU LL SHEET:62/SIG-18 OF: 70 JOB NO.: 17534 DWG: DETS-PDFS-SH 36