Loading...
HomeMy WebLinkAboutP_Grant Place Townhomes_APPROVED Revised Water Main Conns_20210111.pdfGGGP "CAUTION" 8" HIGH PRESSURE GAS MAIN PP CP PPPPCGGGGGGSSMH #9 SSMH #4 S-0463 SSMH #2 SSMH #1 CB #8 (TYPE I) STORMFILTER MANHOLE SFMH#1 (TYPE II-72"Ø) CB #14 (TYPE II-48"Ø) EX SDMH-1 (TYPE II-SOLID LID) 5.33' 4.16' 3' COVER CB #2 (TYPE I) CB #1 (TYPE I) 2.66' 5.00' 3.08' 3.66' COVER · · · · · · · · Know what's below. before you dig.Call R FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. DIMENSIONS SHOWN ARE POTHOLE DEPTHS DIMENSIONS SHOWN ARE POTHOLE DEPTHS IN COMPLIANCE WITH CITY OF RENTON STANDARDS ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 1/8/2021RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 WATER MAIN CROSSINGS W1.0 1 1 W-3910 20069 DEVELOPMENT ENGINEERING Bbannwarth 01/11/2021