Loading...
HomeMy WebLinkAboutD_Shoreline_Exemption_BRPS_210126_v1DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT PLANNING DIVISION CERTIFICATE OF EXEMPTION FROM SHORELINE SUBSTANTIAL DEVELOPMENT DATE: January 26, 2021 PROJECT NUMBER: LUA21-000019, SME PROJECT NAME: King County Black River Pump Station Emergency Fish Screen Repair PROJECT MANAGER: Clark H. Close, Senior Planner PROPERTY OWNER: City of Renton, 1055 S Grady Way, Renton, WA 98057 APPLICANT/CONTACT: Awet Kassa, King County Wastewater Treatment Division | Environmental & Community Services Section, 201 S Jackson St KSC-NR- 5500, Seattle, WA 98104 PROJECT LOCATION: 550 Monster Road SW, Renton, WA 98057 PROJECT DESCRIPTION: The applicant, King County Wastewater Treatment Division (WTD), is requesting a Shoreline Exemption for emergency maintenance and repairs at the Black River Pump Station (BRPS), located at 550 Monster Rd SW, Renton, WA (APN’s 3779200090 and 7229500281) (see attached drawings). The BRPS is located on a concrete dam that spans the Black River channel, conveys all Springbrook Creek flow to the Green River, and is a critical component of the Green River flood control system. The BRPS has operated continually since it was constructed in 1972 and the pump station protects against signification flood damage that could occur if the Green River flood flows back up in the Black River. The repair project is in the Resource Conservation zone and is within the Black River/Springbrook Creek Shoreline Jurisdiction, Reach A (BRSC-A). The Black River is a Shoreline of the State and a Type S stream. Recent heavy rains made two (2) existing King County fish screens inoperable at the BRPS, which is a violation of local, state, and federal fish protection regulations. Due to the storm flows, the fish screens at the BRPS have become blinded with sediment and the inefficient screen cleaning system resulted in increased hydraulic force on the screens. This force caused two screens (6E and 6W) to bend and be permanently deflected. These issues pose a significant risk to the operation of the BRPS, both in terms of flood control operations as well as for fish protection, to keep fish from entering the pump bay. The hydraulic forces on the screens pose a risk of further damage occurring to the screens. The work to correct the current situation would require the following efforts: a. Expedited Fish Screen Replacement – Remove and replace the damaged screens with in-kind and available spare screens as soon as possible. b. Diving Services for Expedited Fish Screen Maintenance – Remove sediment upstream of the fish screens to help free the screens to be raised. c. Fish Screen Cleaning – Raise the “stuck” fish screens out of the channel so they can be cleaned. DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 City of Renton Department of Community & Economic Development King County Black River Pump Station Emergency Fish Screen Repair Administrative Report & Decision LUA21-000019, SME Report of January 26, 2021 Page 2 of 3 D_Shoreline_Exemption_BRPS_210126_v1 The work to restore the BRPS to a state comparable to its original condition would occur within the ordinary high-water mark of the Black River or on the uplands immediately adjacent to the Black River. The proposed project would not alter the current use of the facility or property. The proposed project does not include any fill or excavation, nor the removal of any trees, nor does it include any work that would exceed 35 feet above the average grade level or obstruct any views. The proposed work would occur as soon as permits are received or January 29, 2021, whichever occurs first. SEC-TWN-R: SW ¼ of Section 13, Township 23N, and Range 4E W.M. LEGAL DESCRIPTION: JUNCTION ADD POR TRS 21-22-23-24 & 25A & POR TRS 26 & 29 RENTON SHORELANDS 2ND SUPL ADD BEG SW COR SEC 13-23-04 TH E 1271.74 FT TH N TAP ON BDRY LN BET TRS 28 & 29 OF SD RENTON SHORELANDS 2ND SUPL ADD & TPOB TH CONTG N 275 FT TH W 280.69 FT TH S 59-53-47 W 377.52 FT TH S 74-13-19 W TO ELY MGN OF CO RD TH SELY ALG SD ELY MGN TO SLY BDRY OF SD TR 29 TH ELY ALG SD SLY BDRY TO TPOB ALSO BEG TPOB ABOVE DESC TH N 250 FT TH ON TANGENT CURVE TO RGT RAD OF 627.46 FT TAP ON BDRY LN BEG TRS 26 & 27 OF SD RENTON SH LDS 2ND SUPL ADD TH SWLY ALG SD BDRY LN TO BEG LESS PORTION FOR CO ROAD LESS POR FOR RD PERREC#9704291916 RENTON SHORELANDS 2ND SUPL POR OF TR 28 ALL 30 & POR GL 6 IN SEC 13-23-04 DAF BEG S 87-26-48 E 1271.74 FT E OF SW COR TH N TO NLY MGN CO RD & TPOB TH N TO NLY LN TR 28 TH SWLY ALG NLY LN OF TRS 28 & 30-31 TO ELY MGN CO RD TH SELY & ELY ALG SD RD TO TPOB LESS PORTION FOR TRACT 31 LESS PORTION FOR CO ROAD LESS POR FOR RD PERREC#9704291916 WATER BODY/REACHES: Black River/Springbrook Creek Reach A EXEMPTION JUSTIFICATION: An exemption from a Shoreline Management Substantial Development Permit is hereby Approved on the proposed project in accordance with RMC 4-9-190C ‘Exemption from Permit System’ and for the following reasons: The project meets the requirements of an emergency because it requires immediate action within a time frame too short for full compliance with a shoreline management permit. The damaged fish screens and recent sediment build-up, due to a severe storm event, pose a significant risk to the operation of the BRPS, both in terms of flood control operations as well as for fish protection, and are a threat to public health, safety and the environment. The proposed development is: Consistent with the Shoreline Management Act. Not Applicable to the guidelines of the Department of Ecology where no Master Program has been finally approved or adapted by the Department. Consistent with the City of Renton Shoreline Master Program. (King County Assessor) DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 City of Renton Department of Community & Economic Development King County Black River Pump Station Emergency Fish Screen Repair Administrative Report & Decision LUA21-000019, SME Report of January 26, 2021 Page 3 of 3 D_Shoreline_Exemption_BRPS_210126_v1 SIGNATURE & DATE OF DECISION: ___________________________________________________ __________________ Vanessa Dolbee, Planning Director Date RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on February 9, 2021. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. EXPIRATION: Two (2) years from the date of decision (date signed). Attachment(s): Drawings for Diving Services for Fish Screen Maintenance at the BRPS cc: Darlene Gaziano, King County Wastewater Treatment Division Kerrie McArthur, Confluence Environmental Company DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 1/26/2021 | 2:51 PM PST RECEIVED Clark Close 01/21/2021 PLANNING DIVISION Note-All Elevations shown are NGVD29. Diving Services for Expedited Fish Screen Maintenance at the BRPS Work Order DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 XXXXXXXXXXXXXXXXXX XXXXXXXXXXXXX5001 9.19 111 5003 8.88 142 5048 9.14 142 5090 9.09 142 1.ALL PARKING AND STAGING SHALL BE SITUATED TO FACILITATE CONTINUOUS KING COUNTYACCESS TO ALL GATES, DOORS AND EQUIPMENT.2.GRAVEL ACCESS ROAD FOR NORTH SIDE OF STATION CAN BE ACCESSED FROM MONSTERROAD SW, FURTHER WEST OF VIEW SHOWN IN THIS DRAWING. PROVIDE NOTICETWO-WEEKS PRIOR TO CONSTRUCTION TO PROJECT REPRESENTATIVE (TO NOTIFY KINGCOUNTY PARKS DEPARTMENT) FOR ACCESS OR USE OF LAKE TO SOUND TRAIL, PERSPECIFICATION 01 14 30. ACCESS TO TRAIL IS LIMITED TO VEHICLES WITH A MAXIMUM OFTYPE H20 LOADING AND TRAIL OBSTRUCTION SHALL BE MINIMIZED. CONTRACTOR SHALLPREPARE AND SUBMIT A TRAFFIC CONTROL PLAN, WHICH SHALL BE IMPLEMENTED DURINGUSE OF THE LAKE TO SOUND TRAIL, PER SPECIFICATION 01 55 26.3.REFER TO G-00001 FOR NORTH SIDE GRAVEL ACCESS ROAD CONNECTION TO MONSTERROAD.4.PROVIDE SPECIFIC PROPOSAL AND OBTAIN WRITTEN APPROVAL FROM PROJECTREPRESENTATIVE PRIOR TO LEAVING A TRAILER OR ANYTHING ELSE OUTSIDE TO REMAINOVERNIGHT (OR LONGER).5.THIS DRAWING DEPICTS GENERAL ACCESS FOR THE PUMP STATION SITE. AERIAL PHOTOAND SURVEY FEATURES ARE NOT ACCURATELY ALIGNED, AND ARE NOT SUITABLE FORDIMENSIONING. CONTRACTOR SHALL DETERMINE DIMENSIONS AND CLEARANCES FORACCESS AS NEEDED.NOTES:PRIMARY SITEACCESSPRIMARY BUILDING ACCESS15'H x 12'W ROLLUP DOORAPPROXIMATE LOCATIONOF EXISTING PUMPS1 THROUGH 4 MONSTER ROAD SWOF336-12345DESIGNED/DRAWN:PROJECT ENGINEER:PROJECT MANAGER:CONTRACT NO:DRAWING NO:SCALE:PROJECT FILE NO:DATE:SHT NO / TOTALREVNO:12345EFGHBCDACHECKED:REFERENCE1"0NOREVISION DESCRIPTIONBYAPVDDATEEFGHBCDA DEPARTMENT OF NATURAL RESOURCES & PARKSWATER AND LAND RESOURCES DIVISIONAPPROVED BY:58Know what's below.RCall before you dig.BLACK RIVER PUMP STATION IMPROVEMENTSHIGH-USE ENGINESOCTOBER 2020T. BEAN 1129574BORDER FILE EDITION: 1129574-Dsize-TB-BorderC:\pw_workdir\den003\ch2mhill_dyang1\d0469850\1129574-OF336-G-10001.dwg | Layout: LayoutPLOTTED: Oct 16, 2020-01:47:34pm By dyang1XREFS: 1044885xBASEMAP2.dwg; wetlands_HEC_delineated.dwg; x_HC_Pump-Plant PMX REV.dwg; x_OHM.dwg; 1129574-Dsize-TB.DWG; blackriver_aerial_r_w_jpg.dwg; PE-ELB-WA__Erik_stamp.dwgIMAGES: BRPS.jpg;SITE ACCESS PLANG-100016R. REISERE. BRODAHLS. DORANAS NOTED0T. DAVISSECONDARY BUILDINGACCESS, 15'H x 12'WROLLUP DOORGRAVEL ACCESS ROAD TONORTH SIDE OF STATION0306090SCALE: 1"= 30'TEMPORARY CONSTRUCTION STAGING AREA AND WORK LIMITS, MAINTAIN ACCESS FORKING COUNTY STAFF AT ALL TIMES, OR COORDINATE TO OBTAIN WRITTEN APPROVALFROM PROJECT REPRESENTATIVE FOR SPECIFIC TIMES WHEN ACCESS WILL BEOBSTRUCTED OR MUST BE LIMITED.DEDICATED CONSTRUCTION STAGING AREA. COORDINATE FINAL DIMENSIONS IN THEFIELD WITH THE PROJECT REPRESENTATIVE.WORK AREA LIMITS SHALL BE WITHIN FENCED AREAS NORTH AND SOUTH OF PUMPSTATION BUILDING, EXTERNAL WALKWAYS OUTSIDE OF PUMP HOUSE BUILDING ANDWITHIN BUILDING.MAINTAIN 20-FT CLEARANCE BETWEEN SITE TRAILER AND BOLLARDS AROUND FUELSTORAGE TANK TO ALLOW FUEL TRUCK CLEARANCE THROUGH THE SITE.SEE DRAWING M-40001 FOR REMOVAL OF EXISTING CONCRETE STOP LOGS ANDSTORAGE OF NEW FRP STOP LOGS IN EXISTING STOP LOG STORAGE AREA.KEY NOTES:112233PERSONNELACCESS DOOR1CONSTRUCTIONACCESS FROMMONSTER ROADSEEFOR PUMP FLOORACCESS PLANXXXXXXXXXXXXXXXXXEXISTING CHAINLINK FENCEBULK DIESEL FUELSTORAGE TANKSAND PANELVEHICLEACCESS GATEVEHICLEACCESS GATEEXISTINGTRANSFORMERSTAGING AREAFOR TRAILERSTAGING AREA FORADDITIONAL PARKING2244TABLE OF EXISTING CONTROL POINTS:TABLE NOTES:1.NORTHINGS AND EASTINGS PROVIDED IN TABLE ARE ACCURATEAND PROVIDED FOR REFERENCE, BUT LOCATIONS ON PLAN VIEWARE INACCURATE AND APPROXIMATE COMPARED TO AERIALPHOTO. (SEE NOTE #5 ABOVE)2.POINTS NOT SHOWN ON THIS DRAWING ARE OUTSIDE OF VIEW.(AS INDICATED WITH "ɸ")55G-100021EXISTING CHAINLINK FENCEVEHICULARACCESS GATEPERSONNELACCESS GATE11[5001][5003][5090][5048]ɸɸ2G-4000121G-40001SITE AND ACCESS PLAN1"=30'SCALE:10/21/2020G-2SITE PLAN FORSLURRY PUMPINGRoute the 4" dischargehose to the downstreamside of the station.Hydraulic power pipingbetween the power unit andthe submersible pump, aswell as the 4" discharge hosefrom the pump to thedownstream side of thestation.Diesel-FueledPower Unit forSlurry PumpDocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 Route the hydraulic power hose and discharge hose for the slurry pump on the pier walkway S-4 This cross section provides the general layout of the BRPS. See attached section on S-13 for section through screens 6E&6W. DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 ;.,.::.::..:: :.;::::.::.:~:.::: ~~~;"::~~~"'-"::'''::F 0+ •••• ':-: I ,.: . : '7"aj .. ~"., • ";"';£',. -:> ... :=.-....... "'''. :~.;". ~:~"::'" ":-::- : I , I I I L-J ZZ '·o ' zZ'.o" ~---~~----4---~~-----r--~~----~------ ~.' ---~t COL ~ A . S ' S ~ 1~==~~1 ~------~ ~ , E.L . z..S'·~,'- ~.~J_~)L CD DETAIL J'2' ~ 1'-0" TYP IC AL PEDES TAL TYPICAL CORNER PEDESTAL r V~·+ COUI-J .... e:R, ~UNK '&OL" <e ,,'.0"0.<.. '1l"~ 1/4" I!A~ '. ___ ~V PLAN >f!..' :.1 '-0' DETA IL '/7..". '·-0" Izt " .. \ l... '2.'><. '2.",,-'4" \ 2." E.XF '::'01 "" FILLER ( \ v"," MASTIC SE .... U:.R TYR 'OET"'IEEIo..l PED""-AROUND TRE .... C~ ~I~S ~ l!DTTON1 h ,,' EX PA}I"'ION .:JOINT FILLE R ii (r).% .. ~A.'e,. PI<O). :?>" 2," _ f <'l SECTION SE CTI ON DETAIL l.'OW:ZI SECTION I -------1 'Z~'-o" SECTION ~CLF ~LL314'~ (.OlII:.. Co.I-1C\'\0!?5 e4'·O" o/c '------ I' Y1·· "-0' e 0 ,Yz.' "'ELI:I£I:I PIPE HMIt~lI.A\L S" SECTION '/z'" ,'·0" 'Z 3 4 S 10 NOTE5 : IOl2HS 10 15 10 I. WALKWAY GRATING &:ARING BARS S~ALL!.E 1'><, ~/I6"x l'''bO.CALl OlliE-II- GRJI..'II'IG "'f\~1.1. B~ 17'4. YI~; .. I'Ir\'"O.C. 2..DIMENSIONS FOR 51CcE' OF OPelo\\I'G;~' A"JCHOR BOLTS DE'PE'NDENT ON PUM P MANUFACTURER. 3.SEE I)"'GS M'''j~' M·I2. PIPIIJ(, BLOCKOOTS { INSERTS. Y",': 1'-0" ntH GRAPI-IIC SCALES --u.s. DEPARTMENT Of A&IlICIJLT1JRE SOIL CQNSStVATION SEIlVICE .... , ....... taS. 'Mc.-~w", \"'I~llCMt .... OCM'."~ ~_~w_ ou ..... SmUCTURAl-GENERAl !i'1.v4-PLAN OF OPERATING --JM.c FLOOR ~ DETAILS ........ Pi)" e,o.sr sloe ~ml'Jl1lo GREEN RIVER WATERSHED G~'K . ICIN6 COUNT\'. WASHIN6TON w~m. -1'/"/4? -'~.:, --!~q;z,~ H~"."'"""" ~-~o., MW. NO. DaAJI e..JJt_ UW.t.lI. "",,$-5 .. 4" pump discharge hose hydraulic power hose to and from slurry pump 4" discharge hose to downstream Power unit for slurry pump Left to right: Screens 1E/1W, 2E/2W, 3E/3W, 4E/4W, 5E/5W, 6E/6W, 7E/7W S-5 Engine Room Floor (Pumps and Engines not Shown) Screens 6E&6W in this area See Section on Dwg S-13 See Section A, Dwg S-2 for general layout of BRPS DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 Left to right: Screens 1E/1W, 2E/2W, 3E/3W, 4E/4W, 5E/5W, 6E/6W, 7E/7W Note channel width of 9'-0" S-6 See Section A, Dwg S-2 for general layout of BRPS See Section on Dwg S-13 Screens 6E&6W in this area DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 Channel area upstream of screens is to be cleared of sediment with slurry pump For Screen Details, see Dwg S-80) S-13 Screen 6E Ladder not shown Screen 6W Water level range EL 2.5-4.0 Grating level EL 6.0. Area below grating is a confined space. DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 S-69 Screens 6E&6W in this area. See section on Dwg S-13 DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 The 6" shelf supports the hoist support beams (See Dwg M-14) 3/4" slot width Dwg S-80 The length of the grated opening above the screens is 9'-0" 2'-3" 3/4" slot width The Mechanical Work Order Contractor is responsible for fabricating two new screens (316 SST) 6x6 SST Mesh Detail 2 (See S-13) Detail 3 (See S-13) Detail 1 (see S-13) DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68 ,- :'-v' •..• _.' ...... . L· .. · ..... ~.;,,~ ..... <..,;, ... ~ ..... ,;.,l • .i. ...... ,--_ ... -.; '-"'.:; .... :.::: .~.; ...... - '. -." '. "," .~--. ------...... -~:. .... ".;'" c.~~r·.:~~f"~.··: ,::,", -. . . ",-"'" ..... ';''', , \ PLAN .5c .... u JiI~'!o - I NST R'U M~NT AIR LI NE - ~r~al",,&J;~~< ? ~i ;, ~ r [ .... ~ "~ .;: :~ -.r "~ I , I ' , LJ I ' F ROM PlIMP R ISER , , "m, '" ~., ,," , -, . "~ ~-/ .-IIL,l-l'~+'I ~------- --~ , I ANCI-IOR - SEE DETAII.:~ f+= I;: ~" , ~I L == , 'I;r: , , ,_ 0' L .:.:LI I J ! J ·U -. . -- Ir--++-REAP. SCREEN . REF . D'I.IG . 5·15 (RAISEO POSITION) 0\ \ ~±-+-t-EL'+""$"~' , \ . !il l ~~ SCREE"'. RE~ D:.w'(o. S'7S I' ~. ~ ,'_D' I 8:ij1 ------- ,,, 1. • " 8 If IIIPY"d PsI " I " u.s. w .... TMfJ<f Of A$IlCULII,I.' SOlI. COfG(fIYATIOII SIII'IICI "" ... GREEN RIVY WA1U.SHfO ~_ COU!<TT. W_TON .M-12, -.---. Note-County O&M is responsible for operating the hoists and spray control valves These hoists control the raising and lowering of the Fish Screens These valves control the spray to the Fish Screens as they are being raised out of the channel. Fish Screens 6E&6W are in this channel M-12 DocuSign Envelope ID: 834CE0BE-68CB-44F1-9FFD-6165C9A8CA68