Loading...
HomeMy WebLinkAboutExh.29_Massing_Modulation.pdf3 4 4 ' - 0 " 1 3 6 ' - 0 " 1 6 ' - 0 " 1 3 6 ' - 0 " 1 6 ' - 0 " 4 0 ' - 0 " 4 0 ' - 0 " 8 ' - 0 " 4 0 ' - 0 " 8 ' - 0 " 4 0 ' - 0 " 4 0 ' - 0 " 8 ' - 0 " 4 0 ' - 0 " 8 ' - 0 " 4 0 ' - 0 "240' - 0"88' - 0"16' - 0"136' - 0"40' - 0"8' - 0"40' - 0"40' - 0"8' - 0"40' - 0"8' - 0"40' - 0"75' to Grade Plane16' - 0"56' - 6"Block A is 75' height allowed per approved CU-H (5' higher than the proposed building) Minimum Modulation Dimensions per Renton UDR Required variety of modulations for buildings over 160' per Renton UDR. While no specifics are listed to these, full height and double the width and depth of the minimum would be assumed to meet this requirement Only one roof feature is required per Renton Urban Design Regulations 4' 2' No code maximum for building length. Proposal complies with Lot Coverage. 2 7 0 '1 3 '2 3 '1 1 3 '1 6 '1 0 5 '2 2 '1 2 '2 3 '1 2 '2 2 '1 2 '1 1 '1 1 '1 2 '3 3 '1 2 '2 3 '1 2 '4 '126'69'16'41'11'12'18'11'12'33'13'70' to Grade Plane36'24'11' Proposed modulation exceeds what is required in Urban Design District D Regulations The longest proposed facade length is 113' and has more additional deep cuts into the facade than required. The allowable facade length is 160'. Fulfills "other articulation beyond what is already required in Urban Design District D Regulations". Typical 4' depth of modulation at balconies Block A - Modulation DiagramsDevCo | Solera Renton December 16, 2020 MP-10.0Master Site Plan Modification / Site Plan Review Blocks A & B 1 Block A - Minimum Modulation 3 Block A - Proposed Modulation A Projected cornice as roof extension feature. Urban Design Regulations require at least one roof line element. The proposal has two distinct roof line elements in addition to the typical roof edge condition and fulfills "other articulation beyond what is already required in Urban Design District D Regulations." B Sloped roofs serve as sheds and butterfly roof forms with projected overhangs as roof extension features. C Fan canopy between facades as extended feature elements required by Condition 23. D Curved chamfered building corner as gateway expression at 11th and Sunset Blvd. Not required by Urban Design District D Regulations. Features a curved roof brow as an additional extended roof feature element. Fulfills "other articulation beyond what is already required in Urban Design District D Regulations." CONDITION 23 The Applicant shall provide modulations (both vertical and horizontal) on Mixed Use Buildings A & B beyond what is required by Design District D Regulations. The exterior cladding and articulation on each building shall be a diverse mix of high quality materials commensurate to the overall size and scale of the building. The building shall incorporate upper story setbacks, roof extension features, extended feature elements on the building corners abutting NE 11th St. and NE Sunset Blvd, or other articulation beyond what is already required in the Urban Design District 'D' Regulations. These modulation and articulation features shall be shown on colored elevation sheets and represented on three- dimensional renderings to be submitted with their respective Administrative site plan review applications to be reviewed and approved by the planning Current Planning Project Manager prior to site plan issuance. A B C C D A A B GATEWAYS Intent: To distinguish gateways as primary entrances to districts or to the City, special design features and architectural elements at gateways should be provided. While gateways should be distinctive within the context of the district, they should also be compatible with the district in form and scale. A 4 4 0 ' - 0 " 1 3 6 ' - 0 " 1 6 ' - 0 " 1 3 6 ' - 0 " 1 6 ' - 0 " 1 3 6 ' - 0 "16' - 0"64' - 0"85' to Grade Plane2' - 0" 4' - 0" 85' height allowed per approved CU-H (15' higher than the proposed building) Minimum Modulation Dimensions per Renton Urban Design Regulations Required variety of modulations for buildings over 160' per Renton UDR. While no specifics are listed to these, full height and double the width and depth of the minimum would be assumed to meet this requirement Only one roof feature is required per Renton UDR No code maximum for building length. Proposal complies with Lot Coverage. 4 0 '8 '4 0 '8 '4 0 '4 0 '8 '4 0 '8 '4 0 '4 0 '8 '4 0 '8 '4 0 '4 3 6 '1 1 '9 3 '1 5 '1 0 2 '1 6 '1 0 2 '1 6 '6 8 '1 3 '1 1 '1 2 '1 2 '1 2 '3 3 '1 2 '1 1 '1 6 '1 1 '1 2 '2 2 '2 4 '1 1 '1 2 '3 3 '1 2 '1 2 '1 2 '1 1 '2 3 '1 3 '2 2 '1 2 '1 1 '36' - 6"23' - 6"70' to Grade Plane11' - 0" 11' - 0" 11' - 0" Proposed modulation exceeds what is required in Urban Design District D Regulations The longest proposed facade length is 102' and has more additional deep cuts into the facade than required. The allowable facade length is 160'. Fulfills "other articulation beyond what is already required in Urban Design District D Regulations". Typical 4' depth of modulation at balconies Block B - Modulation DiagramsDevCo | Solera Renton December 16, 2020 MP-10.1Master Site Plan Modification / Site Plan Review Blocks A & B 1 Block B - Minimum Modulation 3 Block B - Proposed Modulation A A A A B B C C C C D CONDITION 23 The Applicant shall provide modulations (both vertical and horizontal) on Mixed Use Buildings A & B beyond what is required by Design District D Regulations. The exterior cladding and articulation on each building shall be a diverse mix of high quality materials commensurate to the overall size and scale of the building. The building shall incorporate upper story setbacks, roof extension features, extended feature elements on the building corners abutting NE 11th St. and NE Sunset Blvd, or other articulation beyond what is already required in the Urban Design District 'D' Regulations. These modulation and articulation features shall be shown on colored elevation sheets and represented on three- dimensional renderings to be submitted with their respective Administrative site plan review applications to be reviewed and approved by the planning Current Planning Project Manager prior to site plan issuance. GATEWAYS Intent: To distinguish gateways as primary entrances to districts or to the City, special design features and architectural elements at gateways should be provided. While gateways should be distinctive within the context of the district, they should also be compatible with the district in form and scale. A Projected cornice as roof extension feature. Urban Design Regulations require at least one roof line element. The proposal has two distinct roof line elements in addition to the typical roof edge condition and fulfills "other articulation beyond what is already required in Urban Design District D Regulations." B Sloped roofs serve as sheds and butterfly roof forms with projected overhangs as roof extension features. C Fan canopy between facades as extended feature elements required by Condition 23. D Curved chamfered building corner as gateway expression at 11th and Sunset Blvd. Not required by Urban Design District D Regulations. Features a curved roof brow as an additional extended roof feature element. Fulfills "other articulation beyond what is already required in Urban Design District D Regulations."