Major Franchise Permit: MFP20002670
IVR Number: 20002670
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:06/24/2020Application Date:0423059062Parcel Number: 1421 UNION AVE NE
Permit Type:08/14/2020Issue Date:Franchise
Permit Work Class:08/16/2021Expiration Date:Major Utility
Job Number: 101117857Franchise Type:Electric
Description: Puget Sound Energy Electric NE 11TH ST & UNION AVE NE Replace/install distribution poles and install OH/UG
switches/reclosers to create a distribution automation scheme for increased reliability.
REVISION: Replace P03. See attached plan.
RESTORATION PER CITY OF RENTON STANDARDS
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031ApplicantX
Carli Bunkelman
PSE/POTELCO - Billing
6905 S 228th St
Kent, WA 98032
B: (253) 437-6708Contact
NGUYEN KHOA D+KIM-ANH 330 QUINCY AVE NE
RENTON , WA 98059
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 1ϭ/Ϯϱ/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.܆ A copy of the Traffic Control Plan (TCP) Application form.
2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
܆ Include map(s) showing the location of the project and work area.
܆ Be legible lettering and clear, contrasting, symbols of viewing or printing.
܆ Must indicate street names, and north arrow and scale.
܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
܆ Types of plans required:
܆ Work hour plan – show all mobility impacts during construction hours.
܆ Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
܆ Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
܆ Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
Scott Warlick CED 8/14/2020
Monday - Friday 8:00AM - 3:00PM
MFP20002670
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
x TCP must be approved prior to commencing the work, and all permit conditions shall be met.
x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
x Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
x Approved Temporary TCP must be at the work site during work hours.
x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
x Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
NE 11TH ST NE 10TH PLTACOMA AVE NE
NE 11TH ST
P01A
P01
2020
2020
2020
151515151616
17171515
15151414UNION AVE NENE 11T
H
S
T
NE 10TH ST
NE 10TH
CT
BUSSTOP
BUSSTOP
M6-2RIGHTKEEPR4-7BRIGHT
KEEP
R4-7B
ROAD
WORKAHEAD W20-1RIGHT
SHOULDER
CLOSED W21-5aRW1-4L200'200'200'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1
100'ROADWORKAHEADW20-1
100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1W1-4R200'200'ROADWORKAHEADW20-1
100'R9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bS/W
CLOSED R9-9S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADPLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE
LLC
000
000
0000 NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKRESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.
N PSE PUGETSOUNDENERGY
JOB#101117857
Union Ave NE & NE 11th St, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 1 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
MFP20002670
NE 11TH ST NE 10TH PLTACOMA AVE NE
P01A
2020
2020
151515151616
17171515
15151414UNION AVE NEUNION AVE NENE 11TH ST
NE 10TH ST
NE 10TH CT
BUSSTOP
BUS
STOP
BUSSTOP
M6-2RIGHTKEEPR4-7BRIGHT
KEEP
R4-7B
ROADWORK
AHEAD W20-1RIGHTSHOULDERCLOSED
W21-5aRW1-4L200'200'200'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1
100'ROADWORKAHEADW20-1
100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1W1-4R200'200'ROADWORKAHEADW20-1
100'S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADR007-L
R9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bS/W
CLOSED R9-9PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999
INFRASOURCE
LLC
0
00
00
0000
0 NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
N PSE PUGETSOUNDENERGY
JOB#101117857
Union Ave NE & NE 11th St, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 2 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
MFP20002670
UNION AVE NENE 14TH PL
P02
UNION AVE NE141314
141314
121212111113111114122121
1010RIGHTKEEPR4-7BRIGHT
KEEP
R4-7BROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L200'200'200'ROAD
WORK
AHEAD W20-1W1-4R200'200'ROADWORKAHEADW20-1100'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888
-9999INFRASOURCE
LLC
000
0
0000
00 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKRESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.M6-2ROADWORKAHEADW20-1350'ROADWORKAHEADW2
0
-
1
350
'
D
E
T
O
U
R
M4-9bR9-11SID
E
W
A
L
K
CL
O
S
E
D
AH
E
A
D
S/WCLOSEDR9-9S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADNE S
U
N
S
E
T
S
T
N PSE PUGETSOUNDENERGY
JOB#101117857
Union Ave NE & NE 11th St, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 3 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
MFP20002670
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
UNION AVE NENE 24TH ST
P03
NE 23RD PL
PRIVATE DRIVE
20201515 17171515 12
12 1218
132ND AVE SEM6-2RIGHT
KEEP
R4-7BRIGHTKEEPR4-7BROADWORK
AHEAD RD-WK-AHDW1-4R200'200'ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L200'200'200'S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/W
CLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1
100'X'X'PLACE W20-1 SIGNS ON ALL
ADJACENT STREETS WITHIN
FEET OF WORK AREA
ROAD
WORK
AHEAD W20-1ROADWORKAHEADW20-1N PSE PUGETSOUNDENERGY
JOB#101117857
Union Ave NE & NE 11th St, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 4 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
MFP20002670
NE 12TH STP04UNION AVE NE1313BUSSTOPBUSSTOP 1413141515BUSSTOPBUSSTOPNE 11TH PL
STOP
FLAGGER
STOP
FLAGGER
ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4200'200'ROADWORKAHEADW20-1
W20-4ONE LANEROADAHEAD200'200'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7A100'RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREEMERGENCY VEHICLES WILL BEALLOWED TO PASS WORK ZONE.MOVE BUS STOP 150' WEST. NOTIFYKING COUNTY METRO CONTACTEDAT 206-477-1150 FIVE DAYS INADVANCE OF SCHEDULED DATE.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857Union Ave NE & NE 12th Stl, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 5 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
NE 7TH ST
NE 7TH STMONROE AVE NENE 7TH STP051212 212117171717MONROE AVE NE
BUS
STOPBUSSTOP
MONROE AVE NENE 7TH ST 11 11 11 10varNE 7TH STKIRKLAND AV NE161616161616
BUSSTOPBUSSTOPSTOP
FLAGGERSTOPFLAGGER
W20-7ARO
A
D
WO
R
K
AH
E
A
D W20-1W20-4ON
E
L
A
N
E
RO
A
D
AHE
A
D100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'FLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONER9-11SIDE
W
A
L
K
CLOS
E
D
AHEA
D
DE
T
O
U
RM4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADMOVE BUS STOP 150' WEST. NOTIFYKING COUNTY METRO CONTACTEDAT 206-477-1150 FIVE DAYS INADVANCE OF SCHEDULED DATE.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#1011178573116 NE 7th St, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 6 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
P06 KIRKLAND AVE NEKIRKLAND AVE NENE 9TH ST
NE 10TH S
T
1616
1818
17171717
1515STOP
FLAGGER
STOP
FLAGGER
W20-7AROAD
WORK
AHEAD W20-1W20-4ONE LANE
ROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'ROADWORKAHEADW20-1
100'
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.
FLAGGERS WILL ASSIST
PEDESTRIAN AROUND
WORK ZONE
R9-11SIDEWALKCLOSEDAHEADS/W
CLOSEDR9-9S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADN PSE PUGETSOUNDENERGY
JOB#101117857
912 Kirkland Ave NE, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 7 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
MFP20002670
NE 11TH PL
P07101010101818 5 13 11 10LYNNWOOD AVE NENE 12TH ST
17171616
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
W20-7AROAD
WORK
AHEAD W20-1W20-4ONE LANEROADAHEAD
100'100'100'W20-7
A
ROA
DWORK
A
H
E
AD
W20-
1
B
E
PR
E
P
A
R
ED
TOST
O
P
W3-4100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'W20-7A100'PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999
INFRASOURCE LLC
000
00000
00 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
FLAGGERS WILL ASSIST
PEDESTRIAN AROUND
WORK ZONES/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADS/W
CLOSED R9-9R9-11SIDEWALK
CLOSED
AHEAD
N PSE PUGETSOUNDENERGY
JOB#101117857
912 Kirkland Ave NE, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 8 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
MFP20002670
NE 7TH STINDEX PL NEP08NE 7TH
ST1616STOP
FLAGGER
STOP
FLAGGER
W20-7AROAD
WORK
AHEAD W20-1W20-4ONE LAN
E
ROAD
AHEAD
100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEAD
W20-1 BEPREPAREDTOSTOPW3-4100'100'100'S/W
CLOSEDR9-9S/WCLOSEDR9-9R9-11SIDEWA
L
K
CLOSED
AHEADR9-11SIDEWALKCLOSEDAHEADPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKFROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK FLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONERESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREEMERGENCY VEHICLES WILL BEALLOWED TO PASS WORK ZONE.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857NE 7th St & Index Pl NE, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 9 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKP09
NE 4TH ST JEFFERSON AVE NEIN
D
E
X
A
V
E
N
E
NE 4TH
S
T
NE 3RD ST
JEF
F
E
R
S
O
N
A
V
E
N
E1818131317
17
17
17
2222BUSSTOP
20
1212
1
1
1
1
1
1
1
0
1
0 1011111111STOP
FLAGGER
STOP
FLAGGERS/WCLOSEDR9-9DETOURM4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W2
0
-
7
AROADWORKAHEADW2
0
-
1
BEPREPAREDTOSTOPW3
-
4
100'
100'
100
'
W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'
1
0
0
'
100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'
350'
R
O
A
D
W
O
R
K
A
H
E
A
D
W20-1
B
E
P
R
E
P
A
R
E
D
T
O
ST
O
P
W3-4350'350'RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.
FLAGGERS WILL ASSIST
PEDESTRIAN AROUND
WORK ZONE
N PSE PUGETSOUNDENERGY
JOB#101117857
NE 4th st & Jefferson Ave NE, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 10 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
MFP20002670
NE 4TH STNE 4TH STOLYMPIA AVE NEP10P10BP10A10 10 10 1010 10 10 1010 10 11 10 10ONLY10 10 11 10 10ONLYMONROE AVE NENE 4TH STBUSSTOP1616ARRW-BRD ROADWORKAHEADW20-1350'350'350'RIGHT LANECLOSEDAHEADW20-5RW4-2LROADWORKAHEADW20-1350'ROADWORKAHEADW20-1 350'
ROAD
WORKAHEAD W20-1350'S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9bPLACE PDETOUR SIGNS AT CROSSWALK/INTERSECTION EAST/SOUTH OF QUEEN AVE NE &NE 4TH ST.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857NE 4th St & Olympia Ave NE, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 11 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDPOLECHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
NE 4TH STNE 4TH STOLYMPIA AVE NEP10P10B10 10 10 1010 10 10 1010 10 11 10 10ONLY10 10 11 10 10ONLYMONROE AVE NENE 4TH ST1616ARRW-BRD S/WCLOSEDR9-9S/WCLOSEDR9-9ROADWORKAHEADW20-1350'RIGHT LANECLOSEDAHEADW20-5RW4-2L350'350'ROADWORKAHEADW20-1350'ROADWORKAHEADW20-1 350'ROADWORKAHEADW20-1100'
ROAD
WORKAHEAD W20-1350'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/W
CLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9bPLACE PDETOUR SIGNS AT CROSSWALK/INTERSECTION EAST/SOUTH OF QUEEN AVE NE &NE 4TH ST.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857NE 4th St & Olympia Ave NE, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 12 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDPOLECHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
P11 SUNSET BLVD NENE 9TH CT
N
E
9
TH
S
TABERDEEN AVE NE12121111
1111
1212
1118
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROAD
WORK
AHEAD W20-1BEPREPA
R
E
D
TOSTOP W3-4200'200'200'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-410
0
'
100
'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD200'200'200'W20-7A
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
N PSE PUGETSOUNDENERGY
JOB#101117857
Aberdeen Ave NE & Sunset Blvd NE, Renton, WA 98056
6/4/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 13 of 15
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 010741
Exp.5/31/2021
stephen.gadke@pse.com
(425) 424-6431
TEMPORARY TRAFFIC CONTROL PLAN
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
55 +
60/65
45/55
35/40
30
25
SIGN SPACING
"X"
800
500'
350'
200'
100'
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
MFP20002670
SW110 10 10 10
10 10 10 10
10111111111011111111NE S
UN
SET
B
L
VD
NE
SUNSE
T
B
LV
D1717 10 10 10 1010 10 10 10 161610 10 10 1017171818NE 12TH STKIRKLAND AVE NEKIRKLAND AVE NENE 12TH STJEFFERSON AVE NEHARRINGTON PL NE
ARRW-BRD
ROADWORK
AHEAD W20-1100'100'100'RIGHT LANECLOSEDAHEAD W20-5RW4-2LROADWORKAHEADW20-135
0
'ROADWORKAHEADW
2
0
-
1
350
'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1
100'
S/W
CLOSED R9-9DETOUR M4-9bR9-11SIDEWALK
CLOSED
AHEAD S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bPLACE PDETOUR SIGNS ATCROSSWALK/ INTERSECTION EAST,/NORTH OF HARRINGTON AVE NE &NE 12TH ST.NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857NE 4th St & Olympia Ave NE, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 14 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDPOLECHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
1111111616
NE 7TH STSUNSET BLVD NE
111111131312121414
ABERDEEN AVE NE
NE 6TH PL P12STOP
FLAGGERSTOP
FLAGGER
W20-7AROAD
WORK
AHEAD W20-1W20-4ONE LANE
ROADAHEAD100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4200'
200'200'
W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
200'
200'200'PLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARKRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREEMERGENCY VEHICLES WILL BEALLOWED TO PASS WORK ZONE.DETOURM4-9bS/WCLOSEDR9-9S/W
CLOSEDR9-9FLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONENPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101117857NE 4th St & Olympia Ave NE, Renton, WA 980566/4/2020safaa.alneema@pse.com(425) 398-6077SHEET 15 of 15CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20002670
P03*
***
**
*
**
*
**
P02
P01
P04P07
SW1
P06
P05
P08
P10P09
P11
*P12
N
Vicinity Map
101117857-R3ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
101117857 PRE-14 DA SWITCHES
Owner / Developer Contact Info
officeATTN:
N/A
N/A
N/A
COLIN O'BRIEN 425.457.5377PHONE
CABLE TV
11475544 101117857
N/A 593204224
N/A 108...
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Removal
OH Expense
LEGEND
CONDUIT RISER
OVERHEAD TRANSFORMER
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
SECONDARY HANDHOLE
EXISTING CONDUCTOR TO BE REMOVED
OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
ENERGY CUSTOMER DEMAND POINT
OR
OR
OR
OVERHEAD JUMPER CONNECTION
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
RECLOSER
GOOGLE MAPS
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 1 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
GENERAL SPECIFICATIONS
Project Information:
Project Name: 2405E053 DA EGT-12
Notification Number: 11428792
WBS # Distribution Electric -E-Distribution Automation - Dist:
R.10009.12.03.01 for 2019 CAPITAL: $ 1,115,833
R.10009.12.03.05 for 2019 OMRC: $ 45,767
System Planner and phone number: Bill Foster (425) 456-2750
Conceptual Estimate: CAP: $ 1,161K
Required In-Service Date: 2019
Location- City/County: Bellevue /KING
Is this a multi year project or revision to previous scope (Y/N):N
Project Justification:
This project is to improve the performance of President Park circuit 14 which has 5 outages in the
2013 -2017 study period (4 are Non-Storm) with the other proposed Circuits having a total 7
outages (6 non-storm).
Project Summary:
This project is to improve the performance of President Park circuit 14 which has 5 circuit outages
between 2013 and 2017. A Distribution Automation scheme is proposed dividing the circuit into 2
Zones with an additional 2 zones to the north.
Zone 1 will be between PRE PCB-14 and X11162#
Zone 2 will be between X11162# and X355 (NO with HIG-13)
Additional zones north of X188 and north of X11161 will be upgraded to SCADA but not part of DA.
Zone 3 will be between PRE PCB-11 and X676
Zone 4 will be between X676, X77904, X1929 (NO with HIG-16), and X363 (NO with PRE-12)
Zone 5 will be between X77904 and X569 (NO with HIG-13)
Zone 6 will be between PRE PCB-12 and X1928#
Zone 7 will be between X1928# and X363 (NO with PRE-11)
Zone 8 will be between HIG PCB-16 and REC #1#
Zone 9 will be between REC #1# and X678
Zone 10 will be between X678 and X1929 (NO with PRE-11)
Zone 11 will be between HIG PCB-13 and U1925
Zone 12 will be between U1925 and X569 (NO with PRE-11), X355 (NO with PRE-14)
Design Detail:
This project will install 10 new SCADA Reclosers, change out recloser controllers to SCADA at 1
location and replace a PMH-9 pad mount switch to SCADA unit to help isolate problem area. The
Project team will evaluate and defined how each substation breaker will be handled to allow this
automation to occur.
On President Park 14 (PRE-14):
In the area of X11162, located on transmission pole 17\2, grid 318564-167127 Replace the GOPI
with a new Recloser and Controller. While this location works fine for this DA scheme Planning
believes pole 318535-167128 might be a location with better location for parking. If this location is
preferred planning would encourage keeping the same switch number for this location since it circuit
functionally is the same.
At X0188 located on pole grid 318711-167123, replace the existing controller if necessary with a
new unit that has SCADA capability. NOTE this location (and X11161 will not be part of this
Distribution Automation scheme but will provide an additional segment of protection when settings
are coordinated.
At X11161 located on pole grid 319027-167130, replace the GOPI with a new Recloser and
Controller and extend TPX from pole grid# 319006-167130.
NOTE this location (and X0188 will not be part of this Distribution Automation scheme but will
provide an additional segment of protection when settings are coordinated.
At X355 located on grid 318639-167103 (Normal Open between PRE-14 & HIG-13), replace the
GOPI with a new Recloser and Controller and use TPX from the 25 kVA transformer at grid#
318635-167126.
On President Park 11 (PRE-11):
At X0676 located at grid 318352-166830, Replace whatever is necessary to make this Recloser &
Controller SCADA enabled.
At X77904 located on grid 318464-166801, replace the GOPI with a new Recloser and Controller
and use TPX from the 50 kVA transformer at grid# 318449-166801.
At X569 located on grid 318626-166846(Normal Open between PRE-11 & HIG-13), replace the
GOPI with a new Recloser and Controller and install TPX from the 37.5 kVA transformer at grid#
318613-166827.
At X1929 located on grid 318320-166761(Normal Open between PRE-11 & HIG-16), replace the
GOPI with a new Recloser and Controller and use TPX from the 100 kVA transformer at grid#
318326-166782.
At X363 located on grid 318128-166766 (Normal Open between PRE-11 & PRE-12), replace the
GOPI with a new Recloser and Controller and use TPX from the 25 kVA transformer at grid#
318142-166770.
On President Park 12 (PRE-12):
In the area of X1928, located on grid 318113-166892 replace the GOPI with a new Recloser and
Controller. While this location works fine for this DA scheme Planning believes pole 318113-166910
might be a better location for parking. It might may make sense to replace pole this to the east for
good extended access. If this location is preferred planning would encourage keeping the same
switch number for this location since it circuit functionally is the same.
On Highlands 16 (HIG-16):
Install REC #1 in the area of south of grid 318495-166472 Install a new pole, with a new Recloser
and Controller. Intercept and use TPX from the 25 kVA transformer at grid# 318495-166472.
Communication with the City of Renton should be made prior to permitting to discuss the value of
this Distribution Automation project to the community and this location.
On Highlands 13 (HIG-13):
At U1925 grid# 318650-166771, replace PME-9 with a pad mount SCADA VISTA 422. Install a 507
vault with a non-skid lid for a 25 kVA transformer near Jbox 318649-166771 and connect with a C
phase 1/0 cable. Trench conduit and TPX to provide a 120V power to switch LVE.
Infrastructure Impacts:
List units added by this project
Reclosers: 12 SCADA units
Switches: 1 pad mount SCADA 422 units
Construction Criteria:
Engineers are to review ownership of all poles they are planning to replace early in the
process so that ample time can be provided in notifying foreign pole owners.
Replace or add poles as needed with poles of sufficient class, height and condition to
accommodate the reconductor. Any 40' pole requiring replacement will be replaced with
minimum 45' pole where possible.
If a pole is replaced, transfer existing equipment to new pole where possible and where
existing condition is in good condition.
Fuse all unfused laterals and request switch numbers for all non-numbered devices.
Coordinate tree trimming/mowing and access construction as required.
Replace all double bushing, leaking, and rusting transformers. Ensure that all grasshopper
fuses are replaced with appropriately sized fuses.
Replace all Open-wire secondary with triplex.
Remove all secondary cross arms and splice all services to the poles.
Install grid number boards on all PSE poles where they're missing.
Install new OH switches and/or switch number boards at all lateral fuse locations where
missing and required by PSE standards.
Install stirrups as required within the replacement area.
Replace all brown glass insulators.
Provide for tree trimming as required.
Replace all trip-o-link cutouts with link-break type.
Regarding the entire project:
Provide planner with preliminary work sketch prior to permitting and a final work sketch when
project is released to POTELCO. Please notify Planner when the project is scheduled, then
complete. Keep Planner notified of correspondence with ROW.
General
-All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards
are available upon request.
-Work sites shall be kept clear of debris and all construction materials; equipment and
packing shall be removed daily.
-Return all unused and removed poles, transformers and hardware to PSE, storeroom. All
copper shall be coiled and returned the day it is removed from the poles. Remove all
unused pins and insulators.
-Return all streetlights, area lights and floodlights to Sumner yard.
Preconstruction
- Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by permitting
agency, in advance of starting work in Right-of-way involving a Permit.
- All system switching shall be approved by System Operations (425-882-4652) a minimum
of 48 hours in advance.
- Notify customers of all outages 48 hours in advance.
Work Drawings & Documents
- Field design changes shall be approved by PSE Project Manager or Engineer.
- Mark all field changes, equipment ID numbers and Underground cable information in red on
Foreman's copy of worksketch.
- Return one Foreman's copy of worksketch to Project Manager at completion of job.
- When permits are required, a copy shall be available on work site at all times.
Safety
- Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements.
- Refer to PSE standards 6275.9050 for personal protective grounding requirements.
- Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements.
- Proper line clearances shall be taken at the beginning, and released at the end, of each work
day, or as otherwise instructed by the System Operator.
- Provide signs, barricades, and traffic control in conformance with permit regulations.
- Utilize flagging and other vehicle traffic control as necessary and in conformance with local
traffic regulations.
- Maintain traffic flow as required by permitting agency.
Erosion & Sediment Control
- Refer to PSE standards 0150.3200 for minimum requirements.
- Comply with all requirements of permitting agency.
- Installed erosion & sediment devices shall be maintained until vegetation has been
re-established or disturbed soil has been otherwise permanently stabilized.
Joint Facilities
- Coordinate with Communication Companies for transfers.
TOP VIEW
FLOWING DITCH or BODY OD WATER
SLOPE
Secure bottom of fence
with gravel bags
Place straw mulch
on disturbed areaExcavated or
Augered Hole
Pole
SLOPE
Install silt fence around
pole excavation
UTILITY POLE EROSION CONTROL DETAIL
Not to scale Adjacent to flowing ditches or bodies of water
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:NICK COULSON
425.495.0982
nick.coulson@pse.com
U-MAPS & 1/4 SECTIONS
2305E010 NW 03-23-05
2305E011 SW 03-23-05
2305E013 NE 04-23-05
2305E015 SW 04-23-05
2305E016 SE 04-23-05
2305E029 NE 08-23-05
2305E033 NE 09-23-05
2305E034 NW 09-23-05
2305E035 SW 09-23-05
2305E036 SE 09-23-05
2305E038 NW 10-23-05
2305E061 NE 16-23-05
2305E062 NW 16-23-05
2305E032 SE 8-23-05
OH MAPS UG MAPS
2305E040
2305E088
OVERHEAD CONSTRUCTION
Poles & Structures
-Poles are to be installed or relocated as staked. Unless otherwise noted, all pole
location measurements are from the center of the pole.
-All new poles set shall be the class indicated on the sketch, or better. Do not set a
lower class pole than specified.
-Install ground plate assembly on all new poles. Install Switch Ground Assembly per
standard specification 6014.1000 at new gang operated switch locations.
-Install grid numbers on all new and existing poles as shown on sketch.
-Straighten existing poles as indicated or as necessary.
-Treat all field-drilled poles with copper napthenate wood preservative.
-Remove old poles after communication companies have transferred off and return to
PSE storeroom. Fill and crown pole holes and restore area similar to adjacent
landscaping.
Conductors & Equipment
-Transfer all overhead and underground primary, secondary and service conductors
and guys to new poles set, unless otherwise indicated on this sketch.
-Transfer existing transformers to new poles unless otherwise indicated on this sketch.
-Use stirrups to connect all overhead and underground primary taps, and all
transformers. Install at all sites being worked within the scope of the project where
they are currently missing.
-Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600
amp switch jumpers. Install tree wire conductor for jumpers on all poles that are
double deadended with tree wire.
-Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
-Connect primary taps and transformers to same phase as existing unless otherwise
shown on the drawing.
-All neutral connections to be made with solid compression connectors. Connect all
pole grounds to common neutral.
-Use Load-interrupter cutouts (with arc shields) on all primary overhead and
underground taps with fused protection above 40T.
-Install Wildlife Protectors on all transformers.
HIG-13,-16
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
3.4.2020 D.N.90% REVIEW
1.6.2021 D.N.CONSTRUCTION DOCUMENTS
MFP20002670
*
***
*
*
*
**
*
*
*
*101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 2 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
OVERHEAD CIRCUIT - BEFORE
SCALE: N.T.S.
P03
P02
P04
P01
HIG-13,-16
P10
P09
P08 P05
P06
P07
SW1
P11
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P12
3.4.2020 D.N.90% REVIEW
MFP20002670
R X188DA
RX11161DA
R
X355DA
NO
R
X0676DA
R
X77904DARX569DA
R
X1929DA
NO
RX363DA
R
X1928DA
R X82214DAS
U1925DA
X11162DAR
X678DA
R 101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 3 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
OVERHEAD CIRCUIT - AFTER
SCALE: N.T.S.
SW1
P04
P01
HIG-13,-16
P02
P07
P06
P05
P08
P09
P10
P03
P11
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
3.4.2020 D.N.90% REVIEW
MFP20002670
PRE
14
P01ABCN
318535-167128
T17\3
318549-16712725kVA 120/240v25TUNK
P01A
318564-167127T17/2X11162
318532-167123 336.4MCMACSR336.4MCMACSRABCNSHUFFLETON-PRESIDENT PARK1101
4100
4103
4101
X11162 DA
318535-167128
P01B 101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 4 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P01
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P01A (318564-167127)
EX. 65' CL 1, 1960 POLE TO BE REMAIN
REMOVE EXISTING GANG OPERATED SWITCH, SW #X11162 2-24R x 2
-TRANSFER SW # X11162 TO RECLOSER ON POLE P01
PROVIDE JUMPER CONNECTION TO CONTINUE CIRCUIT
-INSTALL (3) INSULATORS ON PRIMARY ARMS PER STD 6015.1000 (INDCSA)
-INSTALL #4/0 JUMPER CABLES (MID 8454500)
-INSTALL (3) #4/0 WEDGES (MID 2368200)
P01B (31859-167129)
FOR REFERENCE ONLY
P01 (318535-167128)
EX. 85' CL H1, 2019 POLE TO REMAIN
INST 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH #X11162 DA
BUILD GROUND BUS UNDER CUTOUT ARM SIMILAR TO STD 6043.1020 FIG 5
-INSTALL (2) 4" RIGID CLEVIS (INDNRC)
-INSTALL "C" CONNECTORS (MID 2162700)
-INSTALL #4/0 SD BARE CU JUMPERS FROM NEUTRAL TO BUS (MID 8595700)
-INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P01B ON CIRCUIT PRE-14
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P01B
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P01
318535-167128
15.5kV Viper Recloser
Not To Scale 9946807
3.4.2020 D.N.90% REVIEW
MFP20002670
PRE
14
P02
X188 DA318711-167123X188R
318708-167123
318725-16712337.5kVA 120/240v25TUNK
4/0ACSR4/0ACSR1415
1421
1433
1409
P02A
AØADG351
ABCN
ABC
ABCN
AØ43634
BØ43635
CØ43636
40T
X1466
318705-16712875kVA 120/240v
TR2
101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 5 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P02
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
TR2 (318705-167128)
FOR REFERENCE ONLY
P02A (318708-167123)
FOR REFERENCE ONLY
P02 (318711-167123)
EX. 45' CL UNK, 1973 POLE TO REMAIN
REMOVE EXISTING SEL351R RECLOSER CONTROLLER 2-24R
INST SEL651RA RECLOSER CONTROLLER (MID 9999667) PER STD 6023.1020 2-24N
RE-ASSIGN SWITCH # X188 DA
RECLOSER IS POWERED WITH TRIPLEX SOURCED FROM TR2 ON CIRCUIT PRE-14
RECLOSER IS ORIENTED WITH SOURCE TERMINALS FACING POLE P02A
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
3.4.2020 D.N.90% REVIEW
Site:
Grid #:
Controller Company ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
CONTROLLER REMOVED
12kV
P02
318711-167123
Site:
Grid #:
Controller Company ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
CONTROLLER INSTALLED
12kV
9999667
P02
318711-167123
MFP20002670
PRE
14
P03 NW 03-23-05(2305E010)SE 04-23-05(2305E013)P03A
AØAFS975
BØAFS976
CØAFS977
CRP10
319027-167130X11161X11161 DA
319006-167130100TX3578
319014-167134
BØ25304
ABCN4/0ACSRABCN to GRID 319041-167131319041-167131100TUNK
4/0ACSR2401
2407 101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 6 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P03
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P03A (319006-167130)
FOR REFERENCE ONLY
P03 (319027-167130)
EX. 50' CL 3, 2010 POLE TO BE REPLACED
REMOVE EXISTING GANG OPERATED SWITCH, SW#X11161 2-24R x 2
INSTALL 50 FOOT CLASS H1 OR BETTER POLE PER STD 6010.1000 (PD50H1) 2-23
-INSTALL 1 FEET (SE) AWAY FROM EXISTING POLE
INSTALL 600A G&W VOLTAGE SENSOR IN-LINE WINGARM RECLOSER
(MID 9946808) PER STD 6023.1030 (REC15VGWWI) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH# X11161 DA
BUILD GROUND BUS UNDER CUTOUT ARM SIMILAR TO STD 6043.1020 FIG 5
-INSTALL (2) 4" RIGID CLEVIS (INDNRC)
-INSTALL "C" CONNECTORS (MID 2162700)
-INSTALL #4/0 SD BARE CU JUMPERS FROM NEUTRAL TO BUS (MID 8595700)
-INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P03A ON CIRCUIT PRE-14
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P03A
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946808
9999667
600 A TERMINAL POLE (GROUND BUS EXAMPLE)
6043.1020, Fig. 5
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P03
319027-167130
15.5kV RECLOSER 800 A FOR WINGARM
Not To Scale 9946808
3.4.2020 D.N.90% REVIEW
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P03 319027-167130 50 H1
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P03 319027-167130 50 3 2010
MFP20002670
PRE
14P04
HIG
13
NO
318638-167121
318639-167103X355
318639-167091
25kVA 120/240v
ABC
336.4MCMACSR
40184010
0
ABCCBA336.4MCMACSR
INSTALL 4" HMA ASPHALT PER
CITY OF RENTON STANDARDS
TO CREATE
30'x4'x4" DEEP PULL OFF AREA
P04
NO
318639-167110X355 DA
318640-167126
318635-167126T16/6X25kVA 120/240v
P04
70'101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 7 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P04
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P04A (318638-167121)
FOR REFERENCE ONLY
P04 (318639-167103)
EX. 45' CL UNK, 1960 POLE TO BE REPLACED
REMOVE EXISTING N.O. GANG OPERATED SWITCH, SW #X355 2-24R x 2
INSTALL 50 FOOT CLASS H1 OR BETTER POLE PER STD 6010.1000 (PD50H1) 2-23
-INSTALL 70 FEET (E) AWAY FROM EXISTING POLE
-RENAME POLE 318639-167110
INST 9' 3PH DBL DE ASSY PER STD 6033.1046 (DDE3315)
INSTALL N.O. 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH #X355 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P04A ON CIRCUIT PRE-14
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P04A
INST OVERHEAD BRIDLE SVC PER STD 6024.1000 (BSTPX)
-INSTALL TO SVC ADRESS 4010 NE 12TH ST RENTON 98056
INST 10" SINGLE HELIX ANCHOR EAST L=15' PER STD 6012.1000 (ANDH1)
INST 3/8" PRI DOWN GUY EAST L=15' PER STD 6013.0100 (GYD3SA)
INST 3/8" NEU DOWN GUY EAST L=15' PER STD 6013.0100 (GYD3SAN)
TRANSFER NEUTRAL
TRANSFER OH SVC
COMM TO TRANSFER COMM RISER
INSTALL GRID #
TOP EXISTING POLE 1' ABOVE COMMUNICATIONS
REMOVE EXISITNG POLE AFTER ALL COMMUNICATIONS HAVE TRANSFERRED 2-129
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P04 318639-167110 50 H1
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P04 318639-167103 45 UNK 1960
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P04
318639-167110
3.4.2020 D.N.90% REVIEW
MFP20002670
PRE
11
P05
318351-16682310kVA 120/240v
318352-166830X0676RHLWS
X0676 DA
318363-16684965TUNK
318355-166843
336.4MC
M
A
C
S
R
336.4MCMACSR
3000
32043116
3110
756
P05A
101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 8 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P05
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P05A (318363-166849)
FOR REFERENCE ONLY
P05 (318352-166830)
EX. 50' CL H1, 2016 POLE TO REMAIN
REMOVE EXISTING SEL351R RECLOSER CONTROLLER 2-24R
INST SEL651RA RECLOSER CONTROLLER (MID 9999667) PER STD 6023.1020 2-24N
RE-ASSIGN SWITCH #X0676 DA
RECLOSER IS POWERED WITH TRIPLEX SOURCED FROM P05A ON CIRCUIT PRE-11
RECLOSER IS ORIENTED WITH SOURCE TERMINALS FACING POLE P05A
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
3.4.2020 D.N.90% REVIEW
Site:
Grid #:
Controller Company ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
CONTROLLER REMOVED
12kV
P05
318352-166830
Site:
Grid #:
Controller Company ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
CONTROLLER INSTALLED
12kV
9999667
P05
318352-166830
MFP20002670
PRE
11
P06
318464-166801X77904X77904 DA
912
908
ABC
336.4MCMACSR318449-16680150kVA 120/240v to 318479-166802101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 9 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P06
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P06A (318449-166801)
FOR REFERENCE ONLY
P06 (318464-166801)
EX. 45' CL 1, 2007 POLE TO REMAIN
REMOVE EXISTING GANG OPERATED SWITCH, SW #X77904 2-24R x 2
-NAME IN FIELD IS INCORRECTLY LABELED CK00444
INSTALL 600A G&W VOLTAGE SENSOR IN-LINE RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWTI) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH #X77904 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P06A ON CIRCUIT PRE-11
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P06A
BUILD GROUND BUS UNDER CUTOUT ARM SIMILAR TO STD 6043.1020 FIG 5
-INSTALL (2) 4" RIGID CLEVIS (INDNRC)
-INSTALL "C" CONNECTORS (MID 2162700)
-INSTALL #4/0 SD BARE CU JUMPERS FROM NEUTRAL TO BUS (MID 8595700)
REMOVE EXISITNG POLE STUB 2-129
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P06
318464-166801
3.4.2020 D.N.90% REVIEW
MFP20002670
HIG
13
P07
PRE
11
X569 DA
318626-166846
X569NO
318644-166846
318611-166846
ABC336.4MCMACSR336.4MCMACSR3233
P07A
318613-166827
37.5kVA 120/240v CBAN336.4MCMACSR
ASPLUNDH TO PROVIDE
VEGETATION MANAGEMENT
101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 10 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P07
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P07A (318611-166846)
EX. 45' CL UNK, 2011 POLE TO REMAIN
FOR REFERENCE ONLY
P07 (318626-166846)
ASPLUDH TO PROVIDE VEGETATION MANAGEMENT
EX. 45' CL UNK, 1973 POLE TO BE REPLACED
REMOVE EXISTING GANG OPERATED SWITCH, SW #X569 2-24R x 2
INSTALL 50 FOOT CLASS H1 OR BETTER POLE PER STD 6010.1000 (PD50H1) 2-23
-NEW POLE TO BE PLACED IN EXISTING POLE HOLE (CUT & KICK)
INST 9' 3PH DBL DE ASSY PER STD 6033.1046 (DDE3315)
-ROLL NEUTRAL DOWN TO COMMON POSITION
INSTALL 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH #X569 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P07A ON CIRCUIT PRE-11
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P07A
TRANSFER NEUTRAL
TRANSFER OH SVC
COMM TO TRANSFER COMM RISER
INSTALL GRID #
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P07 318626-166846 50 H1
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P07 318626-166846 45 UNK 1973
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P07
318626-166846
3.4.2020 D.N.90% REVIEW
MFP20002670
PRE
11
P08
HIG
16
NO
318320-166761X1929X1929 DA
318317-166744
318326-166782
25kVA 120/240v
100kVA 120/240v
336.4MCMA
C
S
R
2905
2913
666
3019CBAN336.4MC
M
A
C
S
R ABCN2
2
101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 11 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P08
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P08A (318326-166782)
FOR REFERENCE ONLY
P08 (318320-166761)
EX. 40' CL 1, 1980 POLE TO BE REPLACED
REMOVE EXISTING GANG OPERATED SWITCH, SW#X1929 2-24R x 2
INST 50 FOOT CLASS H1 POLE PER STD 6010.1000 (PD50H1) 2-23
-INSTALL 2 INCHES (NE) AWAY FROM EXISTING POLE
INSTALL THREE-PHASE DOUBLE DEADEND WINGARM FRAMING
PER STD 6033.4026 (DDW313)
-ROLL NEUTRAL DOWN TO COMMON POSITION
INSTALL N.O. 600A G&W VOLTAGE SENSOR WINGARM RECLOSER
(MID 9946808) PER STD 6023.1030 (REC15VGWW) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH# X1929 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P08A ON CIRCUIT PRE-11
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P08A
REPLACE EXISTING PRI & NEU DOWN GUYS TO EXISTING ANCHOR
-INST 3/8" PRI DOWN GUY PER STD 6013.0100 (GYD3SA)
-INST 3/8" NEU DOWN GUY PER STD 6013.0100 (GYD3SAN)
TRANSFER NEUTRAL
TRANSFER OH SVC
COMM TO TRANSFER
INSTALL GRID #
TOP EXISTING POLE 1' ABOVE COMMUNICATIONS
REMOVE EXISITNG POLE AFTER ALL COMMUNICATIONS HAVE TRANSFERRED 2-129
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P08 318320-166761 50 H1
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P08 318320-166761 40 1 1980
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946808
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P08
318320-166761
3.4.2020 D.N.90% REVIEW
MFP20002670
PRE
11
P09
PRE
12
X363 DA318128-166766X363NO
318142-16677025kVA 120/240v
318114-166767T54397.5MCMAACABC
409
2920
443
397.5MCMAACCBAP09A
101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 12 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P09
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
P09A (318142-166770)
FOR REFERENCE ONLY
P09 (318128-166766)
EX. 45' CL 2, 2007 POLE TO REMAIN
REMOVE EXISTING N.O. GANG OPERATED SWITCH, SW#X363 2-24R x 2
LOWER EXISTING NEUTRAL TO 10'-7” FROM TOP OF POLE
INSTALL N.O. 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH#363 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P09A ON CIRCUIT PRE-11
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P09A
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P09
318128-166766
3.4.2020 D.N.90% REVIEW
MFP20002670
P10A
PRE
12
P10B
NE 16-23-05
(2305E061)
SE 09-23-05
(2305E036)
P10
37.5kVA 120/240v X1928 DA
PRE
12
318112-166973T4825kVA 120/240v318113-166940T47100TX2843
318113-16692437.5kVA 120/240v
318113-166910T45
318113-166892X1928 ABCNSHUFFLETON-PRESIDENT PARK
0
318107-166948
3401 #4ACSR3401
P10C
P10D
50kVA 120/240v
TPX L=315'101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 13 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P10
SCALE: 1"=30'
HIG-13,-16
P10A (318113-166892)
EX. 45' CL UNK, 1984 POLE TO REMAIN
REMOVE EXISTING GANG OPERATED SWITCH 2-24R x 2
-TRANSFER SW#X1928 TO RECLOSER ON POLE P10
PROVIDE JUMPER CONNECTION TO CONTINUE CIRCUIT
-INSTALL (6) INSULATORS ON PRIMARY ARMS PER STD 6015.1000 (INDCSA)
-INSTALL #4/0 JUMPER CABLES (MID 8454500)
-INSTALL (6) #4/0 WEDGES (MID 2368200)
P10B (318113-166910)
EX. 95' CL H1, 2010 POLE TO REMAIN
INSTALL 37.5KVA TRANSFORMER PER STD 6025.1000 (TRFPXF) 2-24X
-TAP A PHASE
P10 (318113-166924)
EX. 50' CL UNK, 1965 POLE TO BE REPLACED
REMOVE EXISITNG 37.5KVA TRANSFORMER 2-24R
INSTALL 50 FOOT CLASS 1 OR BETTER POLE PER STD 6010.1000 (PD501) 2-23
-NEW POLE TO BE PLACED IN EXISTING POLE HOLE (CUT & KICK)
INST 9' 3PH DBL DE ASSY PER STD 6033.1046 (DDE3315)
INSTALL 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH #X1928 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P10B ON CIRCUIT PRE-12
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P10B
TRANSFER NEUTRAL
TRANSFER OH SVC
COMM TO TRANSFER
INSTALL GRID #
P10C (318113-166940)
EX.80' CL UNK, 1984 POLE TO REMAIN
FOR REFERENCE ONLY
P10D (318112-166973)
EX.80' CL UNK, 1984 POLE TO REMAIN
REMOVE EXISITNG 25KVA TRANSFORMER 2-24R
INSTALL 50KVA TRANSFORMER PER STD 6025.1000 (TRFRXF) 2-24X
-TAP A PHASE
P10C - P10D
INSTALL #1/0 OH TRIPLEX, L= 315'2-20A
-SOURCED FROM P10D
SPLICE TRIPLEX TO EXISTING (S)
P10B - P10
REMOVE EXISTING TRIPLEX 2-20A
P10- P10C
REMOVE EXISTING TRIPLEX 2-20A
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P10 318113-166924 50 1
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P10 318113-166924 50 UNK 1984
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P10
318133-166924
37.5kVA
Installed at site:
Grid Number:
kVA Rating:
TRANSFORMER INSTALLATION (OH)
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
Foreman to redline the following information
37.5kVA 120/240v
6211300
P10B
318113-166910
P10
318113-166924
3.4.2020 D.N.90% REVIEW
Installed at site:
Grid Number:
kVA Rating:
TRANSFORMER INSTALLATION (OH)
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
Foreman to redline the following information
50kVA 120/240v
6211350
P10D
318112-166973
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P10D
318112-166973
25kVA
MFP20002670
P11
HIG
16
P11A
X82214 DA
318495-166472
318491
166472
75kVA 120/240v25TX9235
318508-166483 ????
318525-166475
318478-166472100TUNK
BØACC924
964
318484-16646675kVA 120/240v
336.4MCMACSR336.4MCMACSR45'101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 14 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
P11
SCALE: 1"=30'
HIG-13,-16
SITE SPECIFIC NOTES:
P11A (318495-166472)
FOR REFERENCE ONLY
P11 (318491-166472)
INST 45 FOOT CLASS H1 OR BETTER POLE PER STD 6010.1000 (PD45H1) 2-23
-INSTALL 45 FEET (S) AWAY FROM EXISTING POLE P11A
INST 9' STD ARM 3PH TAN ASSY PER STD 6033.1012 (TAN313)
INSTALL 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-ASSIGN SWITCH #X82214 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD P11A ON CIRCUIT HIG-16
ORIENT RECLOSER WITH SOURCE TERMINALS FACING POLE P11A
INSTALL GRID #
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P11 318491-166472 45 H1
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P11
318491-166472
3.4.2020 D.N.90% REVIEW
MFP20002670
P12
X678 DA
HIG
16
318383-166442 336.4MCMACSR
336.4MCMA
C
S
R
318377-166462
X678
318374-166481
37.5kVA 120/240v
25T
UNK
678 2029 2033
700 2028
2102
2106
2105
2101 CBAB
CBACBAABC318373-166448CBA336.4MCMACSR101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/20201
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 15 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
HIG-13,-16
SITE SPECIFIC NOTES:
P12 (318377-166462)
EX. 45' CL 4, 1959 POLE TO BE REPLACED
REMOVE EXISTING GANG OPERATED SWITCH, SW#X678 2-24R x 2
INSTALL 50 FOOT CLASS H1 OR BETTER POLE PER STD 6010.1000 (PD50H1) 2-23
-INSTALL 1 FOOT (N) AWAY FROM EXISTING POLE
INST 9' 3PH DBL DE ASSY PER STD 6033.1046 (DDE3315)
INSTALL 600A G&W VOLTAGE SENSOR RECLOSER
(MID 9946807) PER STD 6023.1020 (REC15VGWT) 2-24N x 2
-INSTALL SEL-651RA CONTROLLER (MID 9999667)
-INSTALL CONTROL CABLES (MID 9996186)
-INSTALL VOLTAGE SENSING CABLE (MID 9999670)
-RE-ASSIGN SWITCH#X678 DA
INSTALL TAP FOR RECLOSER TRANSFORMER ON THE SOURCE SIDE OF THE DEADEND
-TAP STREET SIDE PHASE OF CONDUCTOR TOWARD THE WEST ON CIRCUIT HIG-16
ORIENT RECLOSER WITH SOURCE TERMINALS FACING THE WEST
TRANSFER NEUTRAL
TRANSFER OH SVC
TRANSFER OH STREET LIGHT #SLAP1861
INSTALL GRID #
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P12 318377-166462 50 H1
Site:
Grid #:
Recloser Company ID#:
Controller Company ID#:
Recloser Material ID#:
Controller Material ID#:
Foreman to redline the following information
kV Rating:
RECLOSER INSTALLED
12kV
9946807
9999667
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
P12
SCALE: 1"=20'
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P12 318377-166462 45 3 1959
P12
318377-166462
3.4.2020 D.N.90% REVIEW
MFP20002670
HIG
13
SW1
318650-166771U1925U1925 DA
318649-166771
AØEHG000
BØEHG001
CØEHG002
AØ32128
BØ32129
CØ32130
AØACT561
BØACT562
CØACT563
AØACA997
AØACA994
BØACA995
CØACA996
AØ13982
BØ13983
CØ13984
AØACT564
BØACT565
CØACT566
1209
10' x 10'
ACCESS EASEMENT
V01A V01B
318649-166772
V01
AØ13982
BØ13983
CØ13984 AØEHG000
BØEHG001
CØEHG002
AØ32128
BØ32129
CØ32130
SW1
AØ13982
BØ13983
CØ13984 AØEHG000
BØEHG001
CØEHG002
AØ32128
BØ32129
CØ32130
V01A
V01B
V01
U1925 DA
318649-166772
318649-166771 101117857-R3UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
N.COULSON 425.495.0982
D. NESKOW 206.979.6335
N/A N/A N/A
D.NESKOW 206.979.6335 1/4/2021
RW 113757 RENTON/KING
PRE-14 RENTON DA SWITCHES
E-OH SYS. REL. Upgrades - Reclosers - Dist.
RENTON, WA 98059
N/A N/A
N/A 101117857
AS NOTED 16 OF 16
KING N/A N/A QCSOKE
.N/A N/A
...PRE-11,-12,-14
COMCAST
N/A
800-934-6489
CENTURY LINK
N/A
800-778-9140
N/A
N/A
N/A
N/A
N/A
N/A
SW1
SCALE: 1"=20'
HIG-13,-16
SITE SPECIFIC NOTES:
V01 (EXISTING VAULT) SW1 (NEW) - U1925 (318650-166771)
REMOVE EXISTING S&C PME-9 SWITCH
REMOVE EXISTING 5x9 PME-9 LID
INSTALL 5x9 54"x60" VAULT LID (MID 7656904 or 9998665 DEPENDING ON LEGACY MANUF.
UTILITY VAULT or HANSON PRECAST)
INSTALL NEW SCADA PADMOUNT VISTA 422 SWITCH MID 9998778
POWER NEW VISTA SWITCH WITH 120v FROM V01B
RE-USE SW #U1925 & RENAME TO U1925DA
ORIENT SWITCH PER DETAIL "1"
V01A (EXISTING VAULT) (318649-166771)
V01B - (318649-166772)
INSTALL SINGLE PHASE LOOP FEED ANTI-SKID TOTAL UNDERGROUND
TRANSFORMER PER STD 6045.7000 (TUT1SLA)
INTERCEPT EXISTING 200A CABLE 32128-A
SW1 UNDERGROUND CIRCUIT MAP (BEFORE)
SCALE: N.T.S.
10.2.2019 D.N.SYSTEM PROTECTION/60% REVIEW
DETAIL 2: S&C VISTA 422 PADMOUNT SWITCH (220172-167948) U406DA (PROPOSED)
NOT TO SCALE
3
2
1
3
2
1 1
2
3
3
2
1
S&C TYPE PME-9 INTERNAL WORLD
NOT TO SCALE
PADMOUNT SWITCH U1925 (EXISTING)
EHG002-C
EHG001-B
EHG000-A
13982-A
13983-B
13984-C
ACT564-A
ACT565-B
ACT566-C
ACT563-C
ACT562-B
ACT561-A
SECONDARY CABLE & CONDUIT TABLE
LOCATION CABLE Assumed
Lot Corner
CONDUIT VOLTAGE
DROP
VOLTAGE
FLICKER ASBUILT INFORMATION
SIZE LENGTH
Design
(ft)
SIZE LENGTH
Design
(ft)
BENDS
Foreman - Complete
FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable)
V01B V01A 1/0 Triplex 20'2(2)10'1
V01A V01 1/0 Triplex 20'2(2)10'1
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-Complete
LB (600A)DC (200A)
V01 318650
166771 EXISTING Matid:--
SW1 318650
166771
5x9 54"x60" LID
Matid:
7656904/9998665
PADMOUNT VISTA
422 SWITCH
Matid: 9998778
--
V01A 318649
166771 EXISTING Matid:--
V01B 318649
166772
Total UG Transformer
Matid: TUT1SLA
PADMOUNT VISTA
422 SWITCH
Matid: 9998778
WAY 4 WAY 3 WAY 2 WAY 1
SCADACONTROLLERTERMINATION SIDE
OPERATIONSIDE
EHG000-AEHG001-BEHG002-C13982-A13983-B 13984-CACT564-AACT565-BACT566-C72"
15.5"
60"ACT561-AACT562-BACT563-C71"
SW1 UNDERGROUND CIRCUIT MAP (AFTER)
SCALE: N.T.S.
3.4.2020 D.N.90% REVIEW
MFP20002670
Puget Sound Energy
355 110th Ave NE
Bellevue, WA 98004
6/18/2020
City of Renton
Community and Economic Development Administrator
1055 S Grady Way
Renton, WA 98057
Subject: Variance to Renton Code 4-6-090 Utility Lines – Underground Installation
To whom it may concern,
The purpose of this letter is to apply for a variance to install a new distribution pole and overhead
recloser (switch) within the city of Renton ROW. This new distribution pole and recloser will be part of
an automation scheme that will increase reliability to the electric customers within the city limits by
automatically switching and re-routing power during an outage. The proposed location of the new pole
can be referenced on the attached construction drawings as P11 on page 14, approximately 175’ north
of the intersection of Sunset Blvd NE and Aberdeen Ave NE.
PSE is requesting to install a new pole and overhead switch at this location for the following reasons:
• The general area of this pole provides a relative balance in circuit customer count for the
distribution automation scheme. It divides the Highland’s Circuit-16 customer count into 3
equal switching zones which is optimum for an automation scheme
• The proposed location of the pole provides adequate space to keep PSE’s crews safe to pull over
and engage in ongoing maintenance and operation with minimal impact to transportation flows.
PSE’s crews will be parking next to the pole multiple times a year and would prefer an area that
is safe to work
• New reclosers require their own poles to adequately function properly and be maintained.
There are no existing poles between NE 12th St and NE 7th St that do not already have equipment
and/or hardware on them that wouldn’t require extensive extra work to allow the scheme to
function properly.
Along with this request, and as mentioned during our pre-app meeting on February 19th, PSE will comply
with any future requests from the city of Renton to underground this new pole and adjacent spans if a
new development were to arise on the lot to the East (or for any other reason requiring the
undergrounding of the pole and adjacent spans).
We at Puget Sound Energy look forward to your ruling in this matter. If you have any further questions
or concerns, please feel free to contact me at 425-495-0982.
Respectfully,
Nick Coulson, Project Manager
425-495-0982
Nick.coulson@pse.com
MFP20002670