Loading...
HomeMy WebLinkAboutAgenda AGENDA Planning & Development Committee Regular Meeting 4:45 PM - Monday, January 11, 2021 Video-conference 1. Adoption of 2018 Construction Codes a) AB - 2782 Community & Economic Development Department recommends adoption of an ordinance adopting by reference and amending the most recent versions of the Renton Electrical Code, the International Building Code, the Washington State Energy Code, the International Residential Code, the International Mechanical Code, the National Fuel Gas Code, The Uniform Plumbing Code, and the International Property Maintenance Code. Currently, due to the spread of COVID-19, all regularly-scheduled committee meetings will be held as necessary via video-conference. City hall is closed to the public. If you would like to attend this week's meeting remotely, you can do so by going to https://us02web.zoom.us/j/89516018786 Zoom Meeting ID 895 1601 8786 Passcode 482876 You can call through Zoom at 253.215.8782 and use the Meeting ID AB - 2782 City Council Regular Meeting - 04 Jan 2021 SUBJECT/TITLE: Adoption of 2018 Construction Codes RECOMMENDED ACTION: Refer to Planning & Development Committee DEPARTMENT: Community & Economic Development Department STAFF CONTACT: Rob Shuey, Building Official EXT.: 7290 FISCAL IMPACT SUMMARY: N/A SUMMARY OF ACTION: Every three years the International Code Council Updates the international codes. These codes include the building code, residential code, mechanical code, property maintenance code, accessibility code and others. In turn, the State of Washington reviews the codes and adopts them with their own amendments. Pursuant to state law, all cities within the state must adopt the codes and amendments at the local level, concurrently with the state. These codes were to be adopted statewide on July 1, 2020, but because of delays created by COVID-19, the State of Washington decided to put off the adoption of the codes until February 1, 2021. In addition to the International codes, updated versions of other codes such as the Uniform Plumbing Code and the Washington State Energy Code are also being adopted pursuant to state law. The purpose of this code adoption is to remain in compliance with RCW 19.27.031 that requires the city to adopt these codes. EXHIBITS: A. Draft Ordinance STAFF RECOMMENDATION: Approve the proposed code changes and adoption of the related ordinance. AGENDA ITEM #1. a) 1  CITY OF RENTON, WASHINGTON  ORDINANCE NO. ________  AN ORDINANCE OF THE CITY OF RENTON, WASHINGTON; AMENDING  SUBSECTION 4‐5‐030.B.2; SECTION 4‐5‐040; SUBSECTIONS 4‐5‐050.A AND 4‐5‐ 050.C;  AND SECTIONS 4‐5‐051, 4‐5‐055, 4‐5‐090, 4‐5‐100, 4‐5‐110, AND 4‐5‐130 OF THE RENTON MUNICIPAL CODE; ADOPTING BY REFERENCE AND AMENDING THE MOST RECENT VERSIONS OF THE RENTON ELECTRICAL CODE, THE INTERNATIONAL BUILDING CODE, THE WASHINGTON STATE ENERGY CODE, THE INTERNATIONAL RESIDENTIAL CODE, THE INTERNATIONAL MECHANICAL CODE, THE NATIONAL FUEL GAS CODE, THE UNIFORM PLUMBING CODE, AND THE INTERNATIONAL PROPERTY MAINTENANCE CODE; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. THE CITY COUNCIL OF THE CITY OF RENTON, WASHINGTON, DO ORDAIN AS FOLLOWS:  SECTION I. All portions of the Renton Municipal Code in this ordinance not shown in  strikethrough and underline edits remain in effect and unchanged.  SECTION II. Subsection 4‐5‐030.B.2 of the Renton Municipal Code is amended as  shown below. All other provisions in 4‐5‐030.B remain in effect and unchanged.  B.INDIVIDUAL MOBILE/MANUFACTURED HOME INSTALLATION: 1.Installation Permit Required: An installation permit from the Development Services Division shall be required for installation of each  manufactured/mobile home and to connect to utilities. An installation permit shall  not be issued for the location of any mobile home unless the mobile home park  has been issued an occupancy certificate and a license from the Building Official.  2.Installation Requirements: All mobile home installations shall comply with Chapter 296‐150B‐200 M WAC, entitled General Installation Requirements  for Mobile Manufactured Homes. Setbacks, lot coverage and related DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  2  requirements shall be completed and approved and issued prior to the occupation  of each mobile home.  3. Insignia Required: Mobile homes constructed after July 1, 1968 shall  bear the insignia of approval for plumbing, heating and electrical installation  according to chapter 43.22 RCW.  SECTION III. Section 4‐5‐040 of the Renton Municipal Code is amended as follows:  4‐5‐040 RENTON ELECTRICAL CODE:  The most recently published 2020 edition of The Washington Cities Electrical  Code, Parts 1, 2 and 3, as published by the Washington Association of Building  Officials and amended by the City of Renton, is adopted by reference, and shall be  known as the Renton Electrical Code.  The City shall at all times keep on file with the City Clerk, for reference by the  general public, not less than one copy of The Washington Cities Electrical Code.  SECTION IV. Subsection 4‐5‐050.A of the Renton Municipal Code is amended as follows:  A. ADOPTION:  1. The 2015 2018 Edition of the International Building Code (IBC)  including the adoption of ICC/ANSI A117.1‐2009, Requirements for Accessible and  Useable Buildings and Facilities, as adopted and amended by the State Building  Code Council in chapter 51‐50 WAC, as published by the International Code  Council, excluding Chapter 1, Administration, is adopted by reference, together  with the following amendments and additions. The Construction Administrative DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  3  Code, as set forth in RMC 4‐5‐060, shall be used apply in place of IBC Chapter 1,  Administration.  2. Exceptions to the IBC:  The provisions of this code do not apply to temporary growing structures  used solely for the commercial production of horticultural plants including  ornamental plants, flowers, vegetables, and fruits. “Temporary growing structure”  means a structure that has the sides and roof covered with polyethylene,  polyvinyl, or similar flexible synthetic material and is used to provide plants with  either frost protection or increased heat retention. A temporary growing structure  is not considered a building for purposes of this code.  The provisions of this code do not apply to the construction, alteration, or  repair of temporary worker housing except as provided by rule adopted under  Chapter 70.114A RCW or Chapter 37, Laws of 1998 (SB 6168). “Temporary worker  housing” means a place, area, or piece of land where sleeping places or housing  sites are provided by an employer for his or her employees or by another person,  including a temporary worker housing operator, who is providing such  accommodations for employees, for temporary, seasonal occupancy.  3. Appendix E – Supplementary Accessibility Requirements of the 2015  2018 Edition of the International Building Code is also adopted by reference.  The 2015 2018 International Existing Building Code (IEBC) is included in the  adoption of the International Building Code as provided by IBC Section  101.4.7101.5.11 of the Construction Administrative Code, as set forth in RMC 4‐5‐DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  4  060.A.6, and amended in WAC 51‐50‐480000, et seq., including Appendix A,  Guidelines for the Seismic Retrofit of Existing Buildings, excluding Chapter 1, Part  2, Scope and Administration. The Construction Administrative Code, as set forth  in RMC 4‐5‐060, shall be used apply in place of IEBC Chapter 1, Part 2, Scope and  Administration. Provided that detached one‐and two‐family dwellings and  multiple single‐family dwellings (townhouses) not more than three (3) stories  above grade plane in height with a separate means of egress, and their accessory  structures not more than three (3) stories above grade plane in height, shall  comply with the IEBC or the International Residential Code (IRC).  4. The 2015 2018 International Swimming Pool and Spa Code (ISPSC) is  included in the adoption of the International Building Code as provided by IBC  Section 3109.1 and amended in WAC 51‐50‐3109, and as provided by IRC Section  R326 and amended in WAC 51‐51‐0328, excluding Chapter 1, Scope and  Administration. The Construction Administrative Code, as set forth in RMC 4‐5‐ 060, shall be used apply in place of ISPSC Chapter 1, Scope and Administration.  The design and construction of swimming pools, spas and other aquatic recreation  facilities shall comply with the International Swimming Pool and Spa Code ISPSC,  where the facility is one of the following, except that public swimming pool  barriers are regulated by WAC 246‐260‐031(4):.   a.  For the sole use of residents and invited guests at a single‐family  dwelling; DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  5  b.  For the sole use of residents and invited guests of a duplex owned  by the residents; or  c.  Operated exclusively for physical therapy or rehabilitation and  under the supervision of a licensed medical practitioner.  All other “water recreation facilities” as defined in RCW 70.90.110 are  regulated under chapters 246‐260 and 246‐262 WAC.   SECTION V. Subsection 4‐5‐050.C of the Renton Municipal Code is amended as follows:  C. CITY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE:  1. Standpipe Requirements: Height: Section 905.3.1 of the International  Building Code is amended to read as follows:  a. 905.3.1, Height: Class III standpipe systems shall be installed  throughout a building where the floor level of the highest story is located more  than twenty feet (20') above the lowest level of the fire department vehicle  access, or where the floor level of the lowest story is located more than twenty  feet (20') below the highest level of fire department vehicle access.  Exceptions:  i. Class I standpipes are allowed in buildings equipped throughout  with an automatic sprinkler system in accordance with Section 903.3.1.1 or  903.3.1.2.  ii. Class I manual standpipes are allowed in open parking garages  where the highest floor is located not more than one hundred fifty feet (150')  above the lowest level of fire department vehicle access. DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  6  iii. Class I manual dry standpipes are allowed in open parking  garages that are subject to freezing temperatures, provided that the hose  connections are located as required for Class II standpipes in accordance with  Section 905.5.  iv. Class I standpipes are allowed in basements equipped  throughout with an automatic sprinkler system.  v. Group R‐3 does not require standpipes.  b2.  Section 905.3 of the International Building Code is amended to add  a new subsection, to read as follows:  905.3.89, High Rise Building Standpipes: Standpipe risers shall be  combination standpipe/sprinkler risers using a minimum pipe size of six inches  (6"). Two (2) two and one‐half‐inch (2‐1/2") hose connections shall be  provided on every intermediate floor level landing in every required stairway  unless otherwise approved by the fire code official. Where pressure reduction  valves (PRV) are required, each hose connection shall be provided with its own  PRV. The system shall be designed to provide a minimum flow of three  hundred (300) gpm at a minimum pressure of one hundred fifty (150) psi  (maximum two hundred (200) psi) at each standpipe connection, in addition  to the flow and pressure requirements contained in NFPA 14.  23. Dry Standpipes: Section 905.8 of the International Building Code is  amended to read as follows: DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  7  Dry standpipes when approved by the fire code official are acceptable  in other than high‐rise buildings.  4. Snow Loads: Section 1608 of the International Building Code is  amended as follows:  1608.1 General.  Minimum Design Roof Snow Load shall be twenty‐five (25) pounds per  square foot. When using this roof snow load it will be left to the engineer’s  judgment whether to consider drift or sliding snow. However, the engineer  shall consider a rain on snow surcharge of at least five (5) pounds per square  foot for roof slopes less than five degrees (5°).  All remaining sections of 1608 are not adopted.  35. Elevator Car Size to Accommodate Ambulance Stretcher: Section  3002.4 of the International Building Code is amended to read as follows:  3002.4 Elevator car to accommodate ambulance stretcher. Where  elevators are provided in buildings four (4) or more stories above, or four (4)  or more stories below, grade plane; or in any R‐1, R‐2, Group B medical care  office; or I occupancy building provided with an elevator regardless of the  number of stories, at least one (1) elevator shall be provided for fire  department emergency access to all floors. The elevator car shall be of such a  size and arrangement to accommodate an ambulance stretcher forty inches  (40”) by eighty‐four inches (84”) (610 mm by 2,134 mm) with not less than  five‐inch (5”) (127 mm) radius corners, in the horizontal, open position and DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  8  shall be identified by the international symbol for emergency medical services  (star of life). The symbol shall not be less than three inches (3”) (76 mm) in  height and shall be placed inside on both sides of the hoistway door frame.   SECTION VI. Section 4‐5‐051 of the Renton Municipal Code is amended as follows:  4‐5‐051 WASHINGTON STATE ENERGY CODE ADOPTED:  The Washington State Energy Code (WSEC), as adopted by the State Building Code  Council in chapters 51‐11C and 51‐11R WAC, excluding the Administration  sections C106 C107 through C111 and R106 R107 through R111, is adopted by  reference. The Construction Administrative Code, as set forth in RMC 4‐5‐060,  shall be used applied in place of the Administration sections C106 C107 through  C111 and R106 R107 through R111.   Exception:  The provisions of this code do not apply to temporary growing structures used  solely for the commercial production of horticultural plants including ornamental  plants, flowers, vegetables, and fruits. A temporary growing structure is not  considered a building for the purposes of this code. However, the installation of  other than listed, portable mechanical equipment or listed, portable lighting  fixtures is not allowed.  The provisions of this code do not apply to the construction, alteration, or repair  of temporary worker housing except as provided by rule adopted under Chapter  70.114A RCW or Chapter 37, Laws of 1998 (SB 6168). “Temporary worker housing”  means a place, area, or piece of land where sleeping places or housing sites are DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  9  provided by an employer for his or her employees or by another person, including  a temporary worker housing operator, who is providing such accommodations for  employees, for temporary, seasonal occupancy.  SECTION VII. Section 4‐5‐055 of the Renton Municipal Code is amended as shown on  Attachment A.  SECTION VIII. Section 4‐5‐090 of the Renton Municipal Code is amended as follows:  4‐5‐090 INTERNATIONAL MECHANICAL CODE ADOPTED:  A. ADOPTION BY REFERENCE:  The 2015 2018 Edition of the International Mechanical Code (IMC), as adopted  and amended by the State Building Code Council in chapter 51‐52 WAC, as  published by the International Code Council, is adopted by reference with the  following additions, deletions and exceptions: Provided, that Chapter 1, Scope and  Administration, is not adopted and the Construction Administrative Code, as set  forth in RMC 4‐5‐060, shall be used applied in place of IMC Chapter 1, Scope and  Administration. Provided, that the installation of fuel gas distribution piping and  equipment, fuel gas‐fired appliances and fuel gas‐fired appliance venting systems  shall be regulated by the 2018 International Fuel Gas Code. Provided, that  detached one (1) and two (2) family dwellings and multiple single‐family dwellings  (townhouses) not more than three (3) stories high with separate means of egress  and their accessory structures not more than three (3) stories above grade plane  in height shall comply with the International Residential Code. Provided, that the  standards for liquefied petroleum gas installations shall be the 2014 2020 Edition DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  10  of NFPA 58 (Liquefied Petroleum Gas Code) and the 2014 2018 Edition of ANSI  Z223.1/NFPA 54 (National Fuel Gas Code). References in this code to Group R shall  include Group I‐1, Condition 2 assisted living facilities licensed by Washington  State under chapter 388‐78A WAC and Group I‐1, Condition 2 residential  treatment facilities licensed by Washington state under chapter 246‐337 WAC.  B. EXCEPTIONS:  The provisions of this code do not apply to temporary growing structures used  solely for the commercial production of horticultural plants including ornamental  plants, flowers, vegetables, and fruits. “Temporary growing structure” means a  structure that has the sides and roof covered with polyethylene, polyvinyl, or  similar flexible synthetic material and is used to provide plants with either frost  protection or increased heat retention. A temporary growing structure is not  considered a building for purposes of this code.  C. CONFLICTS:  In the case of conflict between the duct sealing or insulation requirements of  Section 603 or 604 of this code and the duct sealing or insulation requirements of  chapters 51‐11C/ and 51‐11R WAC, the Washington State Energy Code shall  govern.  SECTION IX. Section 4‐5‐100 of the Renton Municipal Code is amended as follows:  4‐5‐100 NATIONAL FUEL GAS CODE ADOPTED:  The 2015 2018 Edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54), as  adopted by the State Building Code Council in chapter 51‐52 WAC, as published DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  11  by NFPA, is adopted by reference. The Construction Administrative Code, as set  forth in RMC 4‐5‐060, shall be applied for the administration of this code.  SECTION X. Section 4‐5‐110 of the Renton Municipal Code is amended as follows:  4‐5‐110 UNIFORM PLUMBING CODE ADOPTED:  The 2015 2018 Edition of the Uniform Plumbing Code (UPC), as adopted and  amended by the State Building Code Council in chapter 51‐56 WAC, as published  by the International Association of Plumbing and Mechanical Officials, is adopted  by reference with the following additions, deletions and exceptions: Provided,  that Chapter 1, Administration, is not adopted and the Construction  Administrative Code, as set forth in RMC 4‐5‐060, shall be used in place of UPC  Chapter 1, Administration. Provided, that Chapters 12 and 14 of the Uniform  Plumbing Code are not adopted. Provided, that those requirements of the  Uniform Plumbing Code relating to venting and combustion air of fuel‐fired  appliances as found in Chapter 5 and those portions of the code addressing  building sewers are not adopted.  The following appendices of the 2015 2018 Edition of the Uniform Plumbing Code  as adopted and amended by the State Building Code Council in chapter 51‐5657  WAC, as published by the International Association of Plumbing and Mechanical  Officials, are also adopted by reference: Appendix A – Recommended Rules for  Sizing the Water Supply System; Appendix B – Explanatory Notes on Combination  Waste and Vent Systems; Appendix I – Installation Standards for Pex Tubing  Systems for Hot‐ and Cold‐Water Distribution. In addition, Appendix C – Alternate DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  12  Plumbing Systems, excluding Sections C303.3 and C304.0 through C601.9, is  adopted by reference.  Where a conflict exists between the provisions of Appendix I and the  manufacturer’s installation instructions, the conditions of the listing and the  manufacturer’s installation instructions shall apply.  SECTION XI. Section 4‐5‐130 of the Renton Municipal Code is amended as follows:  4‐5‐130 INTERNATIONAL PROPERTY MAINTENANCE CODE:  A. INTERNATIONAL PROPERTY MAINTENANCE CODE ADOPTED:  The 2015 2018 Edition of the International Property Maintenance Code (IPMC)  is adopted as amended, added to, or excepted in this title, and shall be applicable  within the City, except Chapter 1, Scope and Administration, and Sections 303,  307, 308, and 507, which are not adopted. The Construction Administrative Code,  as set forth in RMC 4‐5‐060, shall be used applied in place of IPMC Chapter 1,  Scope and Administration.   B. AMENDMENTS:  The following amendments to the Code are hereby adopted:  1. Section 301.2, Responsibility, of the 2018 Edition of the IPMC, is  amended to read as follows:  Responsibility: The owner of the premises shall maintain the structures  and exterior property in compliance with these requirements, except as  otherwise provided for in this code. A person shall not occupy as owner‐ occupant or permit another person to occupy premises which are not in a DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  13  sanitary and safe condition and which do not comply with the requirements of  this section.  2. Subsection 301.3, Vacant buildings structures and land, of the 2018  Edition of the IPMC, is deleted in its entirety and replaced by the following:  301.3 Vacant buildings: All vacant buildings and premises thereof must  comply with this Code. Vacant buildings shall be maintained in a clean, safe,  secure and sanitary condition provided herein so as not to cause a blighting  problem or otherwise adversely affect the public health, safety, or quality of  life.  301.3.1 Appearance: All vacant buildings must appear to be occupied,  or appear able to be occupied with little or no repairs.  301.3.2 Security: All vacant buildings must be secured against outside  entry at all times. Security shall be by the normal building amenities such as  windows and doors having adequate strength to resist intrusion. All doors and  windows must remain locked. There shall be at least one operable door into  every building and into each housing unit. Exterior walls and roofs must remain  intact without holes.  301.3.2.1 Architectural (cosmetic) structural panels: Architectural  structural panels may be used to secure windows, doors, and other openings  provided they are cut to fit the opening and match the characteristics of the  building. Architectural panels may be of exterior grade finished plywood or DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  14  Medium Density Overlaid plywood (MDO) that is painted to match the building  exterior or covered with a reflective material such as plexi‐glass.  Exception: Untreated plywood or similar structural panels may be used  to secure windows, doors and other openings for a maximum period of thirty  (30) days.  301.3.2.2 Security fences: Temporary construction fencing may be  used for a maximum period of thirty (30) days as a method to secure a building  from entry.  301.3.3 Weather protection: The exterior roofing and siding shall be  maintained as required in section 304.  301.3.4 Fire Safety:  301.3.4.1 Fire protection systems: All fire suppression and alarms  systems shall be maintained in a working condition and inspected as required  by the Fire Department.   301.3.4.2 Flammable liquids: No vacant building or premises or  portion thereof shall be used for the storage of flammable liquids or other  materials that constitute a safety or fire hazard.  301.3.4.3 Combustible materials: All debris, combustible materials,  litter and garbage shall be removed from vacant buildings, their accessory  buildings and adjoining yard areas. The building and premises shall be  maintained free from such items. DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  15  301.3.4.3 Fire inspections: Periodic Fire Department inspections may  be required at intervals set forth by the Fire Chief.   301.3.5 Plumbing fixtures: Plumbing fixtures connected to an  approved water system, an approved sewage system, or an approved natural  gas utility system shall be installed in accordance with applicable codes and be  maintained in sound condition and good repair or removed and the service  terminated in the manner prescribed by applicable codes.  301.3.5.1 Freeze protection: The building’s water systems shall be  protected from freezing.  301.3.6 Electrical: Electrical service lines, wiring, outlets or fixtures not  installed or maintained in accordance with applicable codes shall be repaired,  removed or the electrical services terminated to the building in accordance  with applicable codes.  301.3.7 Heating: Heating facilities or heating equipment in vacant  buildings shall be removed, rendered inoperable, or maintained in accordance  with applicable codes.  301.3.8 Interior floors: If a hole in a floor presents a hazard, the hole  shall be covered and secured with three‐quarter inch (3/4") plywood, or a  material of equivalent strength, cut to overlap the hole on all sides by at least  six inches (6").  301.3.9 Termination of utilities: The code official may, by written  notice to the owner and to the appropriate water, electricity or gas utility, DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  16  request that water, electricity, or gas service to a vacant building be  terminated or disconnected.  301.3.9.1 Restoration of service: If water, electricity, or gas service has  been terminated or disconnected pursuant to section 301.3.9, no one except  the utility may take any action to restore the service, including an owner or  other private party requesting restoration of service until written notification  is given by the code official that service may be restored.  301.3.10 Notice to person responsible: The code official may inspect  the building and premises whenever the code official has reason to believe  that a building is vacant, subject to a duly issued court warrant, if there is a  present danger, or under the terms of to exercise the City’s community  caretaking function, or where otherwise authorized by law. If the code official  determines that a vacant building violates any provision of this section, the  code official shall notify in writing the owner of the building or real property  upon which the building is located, or other person responsible, of the  violations and required corrections and shall be given a time frame to comply.  301.3.10.1 Alternate requirements: The requirements and time  frames of this section may be modified under an approved Plan of Action.  Within thirty (30) days of notification that a building or real property upon  which the building is located is in violation of this section, an owner may  submit a written Plan of Action for the code official to review and approve if  found acceptable. A Plan of Action may allow: DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  17  1) Extended use of non‐architectural panels.  2) Extended use of temporary security fencing.  3) Extended time before the demolition of a building is required.  4) For substandard conditions to exist for a specific period of time,  provided the building is secured in an approved manner. When considering a  Plan of Action, the building code official shall take into consideration the  magnitude of the violation and the impact to the neighborhood.  301.3.11 Enforcement: Violations of this section shall be enforced  according to the provisions and procedures of RMC 1‐3‐2 and subject to the  monetary penalties contained therein.  301.3.11.1 Abatement: A building or structure accessory thereto that  remains vacant and open to entry after the required compliance date is found  and declared to be a public nuisance. The code official is hereby authorized to  summarily abate the violation by closing the building to unauthorized entry.  The costs of abatement shall be a lien against the real property and may be  collected from the owner in the manner provided by law.  301.3.11.2 Unsafe buildings and equipment: Any vacant building or  equipment therein declared unsafe is subject to the provisions of RMC 4‐5‐ 060 and the demolition provisions of RMC 4‐5‐060.  3. Section 302.4, Weeds, of the 2018 Edition of the IPMC, is amended to  read as follows: DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  18  Weeds: All premises and exterior property shall be maintained free  from weeds or plant growth in excess of twelve inches (12”) in height on  developedment property or twenty‐four inches (24") in height on vacant land.  All noxious weeds shall be prohibited. Weeds shall be defined as all grasses,  annual plants and vegetation, other than trees or shrubs; provided, however,  this term shall not include cultivated flowers and gardens.  Upon failure of the owner or agent having charge of a property to cut  and destroy weeds after service of a notice of violation, they shall be subject  to the provisions of RMC 1‐3‐2, Civil Code Enforcement of Code.  4. Section 308, Rubbish and Garbage, of the 2018 Edition of the IPMC, is  deleted in its entirety and replaced with a new Section 308, Residential Outdoor  Storage, which shall read as follows:  308 Residential Outdoor Storage:  308.1 Purpose: The purpose of this section is to define and regulate  the outdoor storage of materials on residential property while maintaining the  character and use intended for single family residential neighborhoods.  308.2 Allowed residential outdoor storage: For RC and R‐1 zoned  properties, a maximum of four hundred (400) square feet of area may be used  for outdoor storage. For R‐4, R‐6, and R‐8 zoned properties, a maximum of two  hundred (200) square feet of area may be used for outdoor storage. For R‐10  and R‐14 zoned properties, a maximum of one hundred feet (100') of area may DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  19  be used for outdoor storage. Outdoor storage in excess of the above limits is  not permitted.  308.3 Prohibited areas for outdoor storage: Outdoor storage is  prohibited on residentially zoned property in the following areas:  Front yards  Side yards  Slopes greater than fifteen percent (15%)  Designated open spaces or restricted areas  Critical areas, including wetland, streams and associated buffer areas  308.4 Emergency access: Outdoor storage areas shall not prevent  emergency access to the residential structure or any other building.  308.5 Business related storage: Materials stored outdoors on  residentially zoned properties shall not be owned by or used in any business  or industry including a home occupation business.  308.6 Height limitations: Materials stored outdoors on residentially  zoned properties shall be neatly stacked and not exceed a height of six feet  (6'). Tarps may not be utilized for screening cover outdoor storage.  308.7 Firewood: Firewood must be split, neatly stacked, and intended  for use on the premises on which it is stored. Tarps may be used to protect  cover firewood.  308.8 Membrane structures: Membrane structures are considered  outdoor storage, and subject to the location restrictions in section 308.3. Such DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  20  structures shall not exceed two hundred (200) square feet in area. Membrane  structures shall be immediately removed or repaired in the event of disrepair  or in the event of damage caused by weather, fire, collision, accident, or other  forms of damage. Tarps and makeshift covers are prohibited for this use.  308.9 Prohibited materials: Shipping containers and other similar  storage units do not qualify as accessory buildings on residentially zoned  properties, and are prohibited. Hazardous materials are also prohibited for  outdoor storage on residentially zoned properties.  C. COPY ON FILE:  At least one (1) copy of the adopted edition of the International Property  Maintenance Code shall be on file in the office of the City Clerk.  SECTION XII. If any section, subsection, sentence, clause, phrase or work of this  ordinance should be held to be invalid or unconstitutional by a court or competent jurisdiction,  such invalidity or unconstitutionality thereof shall not affect the constitutionality of any other  section, subsection, sentence, clause, phrase or word of this ordinance.  SECTION XIII. This ordinance shall be in full force and effect five (5) days after publication  of a summary of this ordinance in the City’s official newspaper.  The summary shall consist of this  ordinance’s title.      PASSED BY THE CITY COUNCIL this _______ day of ___________________, 2021.                         Jason A. Seth, City Clerk   DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________  21  APPROVED BY THE MAYOR this _______ day of _____________________, 2021.                         Armondo Pavone, Mayor    Approved as to form:             Shane Moloney, City Attorney  Date of Publication:      ORD:2131:12/23/2020 DRAFTAGENDA ITEM #1. a)  22 ATTACHMENT A 4‐5‐055 INTERNATIONAL RESIDENTIAL CODE ADOPTED: The 2015 2018 Edition of the International Residential Code (IRC), as adopted and amended by the State Building Code Council in chapter 51‐51 WAC, as published by the International Code Council, is adopted by reference, with the City’s amendments thereto, as specified in subsections A through C B of this Section. Chapter 1, Scope and Administration, is not adopted and the Construction Administrative Code, as set forth in RMC 4‐5‐060, shall be used in place of IRC Chapter 1, Scope and Administration. Provided, that Chapters 11 and 25 through 43 of the IRC are not adopted. The energy code is regulated by Chapter 51‐11R WAC; the plumbing code is regulated by Chapter 51‐56 WAC; the electrical code is regulated as adopted by RMC 4‐5‐040.  The standards for liquefied petroleum gas installations shall be 2020 NFPA 58 (Liquefied Petroleum Gas Code) and 2018 NFPA 54 (National Fuel Gas Code). All other fuel gas installations shall be regulated by the 2018 International Mechanical Code and 2018 International Fuel Gas Code. Appendix Q – Tiny Houses, and Appendix U – Dwelling Unit Fire Sprinkler Systems, as found in WAC 51‐51‐60105, are adopted. A. CITY AMENDMENTS TO IRC TABLE R301.2(1), CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA: DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________ 23 Table R301.2(1) of the International Residential Code is amended to read as follows: IRC Table R301.2(1) Climatic and Geographic Design Criteria  Roof Snow Load1 Wind Design2 Seismic Design Category3 Subject to Damage From: Outside Design Temp. – Heat/Cool Ice Barrier Under‐layment Required Flood Hazards5 Air Freezing Index Mean Annual Temp. Speed Topographic Effects Weathering4 Frost Line Depth Termite Decay 25 psf 110 mph See footnote2 D2 Moderate 12" Slight to Moderate 24ºF/83ºF No N/A 113 50ºF  GROUND SNOW LOAD1 WIND DESIGN2 SEISMIC DESIGN CATEGORY SUBJECT TO DAMAGE FROM WINTER DESIGN TEMP ICE BARRIER UNDERLAYMENT REQUIRED FLOOD HAZARDS5 AIR FREEZING INDEX MEAN ANNUAL TEMP Speed (mph) Topographic Effects2 Special Wind Region Windborne Debris Zone Weathering Frost Line Depth Termite 20 110 See Footnote 2 No No D2 Moderate 12” Slight 24° F No N/A 113 50° F MANUAL J DESIGN CRITERIA Elevation Latitude Winter Heating Summer Cooling Altitude Correction Factor Indoor Design Temperature Design Temperature Cooling Heating Temperature Difference 364 Feet 47° 72° F 75° F 0.99 72° F 75° F 45° F DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________ 24 Cooling Temperature Difference Wind Velocity Heating Wind Velocity Cooling Coincident Wet Bulb Daily Range Winter Humidity Summer Humidity 7° F N/A N/A 66 Medium 82% 68%  Footnotes: 1. When using this A roof snow load minimum of twenty‐five (25) pounds per square foot (“psf”)  may be used for design. Iit will be left to the engineer’s judgment whether to consider drift or sliding snow. However, rain on snow surcharge of five (5) psf must be considered for roof slopes less than five degrees (5°). 2. Wind exposure category and Topographic effects (Wind Speed‐up Kzt factor) shall be determined on a site‐specific basis by the Design Professional in Responsible Charge (components and cladding need not consider topographic effects unless otherwise determined by the engineer of record). 3. From IRC Table 301.2(1). 4. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652. DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________ 25 5. The City of Renton participates in the National Flood Insurance Program (NFIP) as specified in City of Renton Resolution No. 1984, dated April 21, 1975. On August 10, 2020, Tthe City’s adopted by Ordinance No. 5977 “The Flood Insurance Study is April 19, 2005 (FIS) for King County, Washington and Incorporated Areas,” effective for all communities in King County on August 19, 2020, with the accompanying , and the number and date of current effective Flood Insurance Rate Maps (FIRMSs). The FIS and FIRMs are on file at the City of Renton, 1055 South Grady Way, Renton, WA 98057. are as follows: 53033CIND0A 04/19/2005 53033C0664F 05/16/1995 53033C0666F 05/16/1995 53033C0668F 05/16/1995 53033C0669F 05/16/1995 53033C0957F 05/16/1995 53033C0976F 05/16/1995 53033C0977F 05/16/1995 53033C0978F 05/16/1995 53033C0979F 05/16/1995 DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________ 26 53033C0981F 05/16/1995 53033C0982F 05/16/1995 53033C0983F 05/16/1995 53033C0984F 05/16/1995 53033C0986F 05/16/1995 53033C0987F 05/16/1995 B. EXCEPTIONS: The provisions of this code do not apply to temporary growing structures used solely for the commercial production of horticultural plants including ornamental plants, flowers, vegetables, and fruits. “Temporary growing structure” means a structure that has the sides and roof covered with polyethylene, polyvinyl, or similar flexible synthetic material and is used to provide plants with either frost protection or increased heat retention. A temporary growing structure is not considered a building for purposes of this code. The provisions of this code do not apply to the construction, alteration, or repair of temporary worker housing except as provided by rule adopted under Chapter 70.114A RCW or Chapter 37, Laws of 1998 (SB 6168). “Temporary worker housing” means a place, area, or piece of land where sleeping places or DRAFTAGENDA ITEM #1. a) ORDINANCE NO. ________ 27 housing sites are provided by an employer for his or her employees or by another person, including a temporary worker housing operator, who is providing such accommodations for employees, for temporary, seasonal occupancy. C. CONFLICTS: In the case of conflict between the duct sealing or insulation requirements of Section 603 or Section 604 of this code and the duct sealing or insulation requirements of Chapter 51‐11C/R WAC, the Washington State Energy Code shall govern.  DRAFTAGENDA ITEM #1. a)