Loading...
HomeMy WebLinkAboutM_LineOfSightDiagrams_210217_v1DN LEVEL 01 0" MEZZANINE 15' -0" 1 2 3 4 5 6 7 8 9 T.O. FASCIA 33' -7" T.O. RIDGLINE 39' -10"5' - 5"6' - 8 1/2"7' - 0"7' - 6"6' - 8 1/2"5' - 5"6' - 8 1/2"6 AN.06 5' - 6"MONSTER ROAD 275' - 0" BUILDING BEYOND, TYP. EXISTING PARAPETEXISTING SKYLIGHTS, TYP.NEW MECHANICAL EQUIPMENT WITH INTEGRATED SCREEN, TYP.8' - 5"(E) PARKING LOT NEW MECHANICAL EQUIPMENT WITHOUT INTEGRATED SCREEN, TYP.10' - 4"CLEAR10' - 0"29' - 9 1/2" PRE-MANUFACTURED RAMP, BASIS OF DESIGN: BLUFF MANUFACTURING GROUND TO DOCK YARD RAMP MODEL 16SYS12030NU SAFETY CHAIN CONNECTION TO EXISTING TILT-UP CONCRETE PANEL 19 AN.06 AN.0620 LEVEL 01 0" MEZZANINE 15' -0" ABCDEFGC.2 T.O. FASCIA 33' -7" T.O. RIDGLINE 39' -10" 1 AN.06 CHARGING STATIONS BEYOND, TYP.5' - 6"MONSTER ROAD(N) PARKING LOT 77' - 9"6' - 8 1/2"6' - 8 1/2"2' - 8 1/2"6' - 8 1/2"7' - 0"7' - 6"5' - 2"3' - 10 1/2"5' - 5"4' - 7"10' - 2"EXISTING PARAPET EXISTING SKYLIGHTS, TYP. NEW MECHANICAL EQUIPMENT WITH INTEGRATED SCREEN, TYP.3 1/2"7' - 0"6' - 8 1/2"NEW MECHANICAL EQUIPMENT WITHOUT INTEGRATED SCREEN, TYP. LEVEL 01 0" MEZZANINE 15' -0" 7 T.O. FASCIA 33' -7" EXISTING CONCRETE TILT-UP WALL EXISTING OVERHEAD DOOR OPENING EXISTING GRADE AT TRUCK COURT PRE-MANUFACTURED RAMP AT LOADING DOCK DOOR CONCRETE CURB FOR RAMP ATTACHMENT LEVEL 01 0" 19 AN.06 EXISTING CONCRETE TILT-UP WALL EXISTING OVERHEAD DOCK DOOR PRE-MANUFACTURED RAMP AT LOADING DOCK DOOR 9' - 0" 10' - 4" CLEAR 10' - 0" WWW.NELSONWORLDWIDE.COM Nelson Architecture & Interiors, Inc. 1200 Fifth Ave., Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Reviewed By:Proj #: PROJECT DIRECTORY: PROLOGIS 12720 GATEWAY DR. SUITE 110 TUKWILA, WA 98168 TEL: (206) 414-7625 ARCHITECT OF RECORD: NELSON WORLDWIDE ATTN: Jennifer Wyman 1200 5TH AVENUE SUITE 1300 SEATTLE, WA 98101 TEL: (206) 408-8500 EMAIL: jwyman@nelsonww.com GENERAL CONTRACTOR: BNBUILDERS ATTN: DAN HUBER 2601 4TH AVENUE #350 SEATTLE, WA 98121 TEL: (206) 382-3443 EMAIL: dan.huber@bnbuilders.com STRUCTURAL ENGINEER: KPFF ATTN: ERIK LOFTHUS 1601 5TH AVENUE, SUITE 1600 SEATTLE, WA 98101 TEL: (206) 622-5822 EMAIL: Erik.Lofthus@kpff.com 2/10/2021 4:11:37 PMC:\Users\KJones\Documents\My Revit Projects\2019\20.0004357.000-SEA124 - Monster Rd_kevansKJ5TB.rvtAN.06 LINE OF SITE STUDIES TENANT IMPROVEMENT BUILDOUT 601 MONSTER RD SW RENTON, WA Checker20.0003376 MONSTER ROAD 1" = 20'-0"AN.06 LINE OF SITE - FROM EAST1 1/4" = 1'-0"AN.06 ENLARGED PLAN AT PRE-FAB RAMP18 1" = 20'-0"AN.06 LINE OF SITE - FROM NORTH6 Issue: No: Date: ISSUE FOR PERMIT 02.12.2021 1/8" = 1'-0"AN.06 SECTION THROUGH RAMP19 3/8" = 1'-0"AN.06 RAMP ELEVATION20 LINE OF SIGHT STUDIES