Loading...
HomeMy WebLinkAboutP_SitePlan_210217_v1VV COMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACT COMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACT COMPACTCOMPACT COMPACT COMPACTCOMPACTCOMPACT COMPACT COMPACTCOMPACTCOMPACT COMPACT COMPACTCOMPACT CCCCCCCCDNCFECFECFECFECFECFECFECFECFECFECFECC123456789ABCDEFGC.2HJKLJ.2N.I.CELECTRIC VEHICLE DUAL CHARGING STATIONS, SERVICING (6) PARKING STALLS INCLUDING 1 ACCESSIBLE STALLFUTURE ELECTRIC VEHICLE DUAL CHARGING STATIONS, SERVICING (6) PARKING STALLS12 TRAILER STALLS RESTRIPPED TO 16 PARKING STALLSEXISTING DUMPSTER LOCATION(E) FIRE HYDRANT(E) PROPERTY LINEMONSTER ROAD SWMONSTER ROAD SW(E) FIRE DEPARTMENT CONNECTION(E) FIRE HYDRANT(E) FIRE HYDRANT(E) FIRE HYDRANT(E) UTILITY VAULTS(E) RIGHT OF WAY(E) RIGHT OF WAY(E) ACCESSIBLE PRIMARY BUILDING ENTRANCE(E) PRIMARY BUILDING ENTRANCE - OTHER TENANT(E) FIRE HYDRANT(E) FIRE HYDRANTNEW ACCESSIBLE PARKING STALL AND WALKWAY TO CONNECT TO EXISTING ACCESSIBLE ROUTENEW COMPACTORNEW DUMPSTER LOCATION FOR (3) 6' X 5' DUMPSTERSFUTURE ELECTRIC VEHICLE DUAL CHARGING STATIONS, SERVICING (6) PARKING STALLS, BASIS OF DESIGN: CHARGEPOINT CT4000 LEVEL 2 COMMERCIAL EV CHARGER, REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION1AN.06AN.052(E) ACCESSIBLE PATH OF TRAVEL(E) ACCESSIBLE PATH OF TRAVEL FROM RIGHT OF WAY(E) ACCESSIBLE PARKING STALLSNEW PRE-MANUFACTURED DOCK RAMPAN.055AN.0618TYP.(E) SKYLIGHTS, TYP.NEW MECHANICAL EQUIPMENT, REFER TO MECHANICAL DRAWINGS, TYP.6AN.06DUMPSTER SCREENING - 6' TALL CHAINLINK FENCE WITH WHITE VIEWGUARD SLATS TO MATCH BUILDING EXTERIOR(NO BUILD)ACCESS AND UTILITY EASEMENT(E) 40' - 0"(E) 40' - 0"(E) 30' - 0"LANDSCAPE DEPTH(E) 10' MIN(E) 25' - 7"(E) 40' - 0"(E) +/- 114'(E) 125'(E) 180'(E) 25' - 0"(E) +/- 210'(E) 25' - 0"(E) +/- 100'PROPOSED OCCUPANCY BREAKDOWN (GROSS SF) PER PLANNINGBUSINESS: 16,388 SFWAREHOUSE: 77,735 SFPARKING REQUIRED: BUSINESS: MIN: 2 PER 1000 SF MAX: 4.5 PER 1000 SFMIN: 33 STALLS MAX: 74 STALLSWAREHOUSE: 1 PER 1500 SF = 52 STALLSTOTAL: MIN: 85 STALLS MAX: 126 STALLSPARKING PROPOSED: 93 STALLS ACCESSIBLE STALLS REQUIRED: PROPERTY: 148 TOTAL STALLS ON SITE PROPOSED (139 EXISTING + 9 NEW)CODE: 101-150 STALLS = 5 ACCESSIBLE STALLS REQUIREDACCESSIBLE STALLS PROPOSED: TENANT: 3 STALLS (2 EXISTING + 1 NEW)PROPERTY: 5 STALLS (4 EXISTING + 1 NEW)EV CHARGING STALLS REQUIRED:INITIAL: 5% OF STALLS = 4.3 STALLSFUTURE: 20% OF STALLS = 17.2 STALLSEV CHARGING STALLS PROPOSED:INITIAL: 5% OF STALLS = 6 STALLSFUTURE: 20% OF STALLS = 17.2 STALLSPARKING ANALYSISPROPOSED OCCUPANCY CATEGORY: OFFICE, EDUCATIONAL AND INSTITUTIONAL DEVELOPMENTSRECYCLING REQUIRED: MIN: 2 SF PER 1000 SF = 188 SFREFUSE REQUIRED: MIN: 4 SF PER 1000 SF = 376 SFTOTAL: 565 SFPROPOSED AREAS:INTERNAL RECYCLING & REFUSE ROOM: 155 SFCOMPACTOR ESTIMATED: 225 SFSITE DUMPSTERS/BINS ESTIMATED: 220 SFTOTAL: 600 SFRECYCLING & REFUSE ANALYSISNEW ACCESSIBLE PARKING STALL CONVERTED FROM EXISTING STANDARD STALLNEW ACCESSIBILITY PATHWAY STRIPPING AND SYMBOLNEW SIDEWALK EXTENSION WITH SLOPE, NOTE: SLOPE SHALL BE 1:12 MAX. & CROSS SLOPE SHALL BE 1:48 MAX., PER IBC SECTION 1012NEW EV DUAL HEAD CHARGING STATION SERVING NEW ACCESSIBLE STALL AND ADJACENT STALL.REMOVE LANDSCAPE FROM AREA SHOWN DASHED AND PROVIDE ASPHAULT LEVEL WITH EXISTING. REPAIR SPRINKLER SYSTEM AND IRRIGATION AS REQUIRED.NEW CURB TO MATCH EXISTING ON SITE CURBS, REFER TO DETAIL ON THIS SHEETNEW ACCESSIBLE PARKING SIGNAGE, REFER TO DETAIL ON THIS SHEETNOTE: PROVIDE DETECTABLE WARNING TEXTURE PER CODE, TYPICAL ALL WHEELCHAIR RAMPS7' - 5"MAX 1:12SLOPE UPCHARGEPOINT CT4000 LEVEL 2 COMMERCIAL EV CHARGER WITH 2 CU. FT. UNDERGROUND CONCRETE BASEALIGNPARKING STALLPARKING STALL2' - 0"CURB STOP, TYP.3"1'-6"5'-0" MIN.1'-6"5"1/2"1'-0"STATEREQUIREDPRE-MANUF. SIGNSET POST IN CONC.4" DIA. STEEL POST W/ CAPVANACCESSIBLEFINISH GRADEGALVANIZED MOUNTING BOLTSDISABLEDPARKINGPERMITNOTE:INSTALL SIGN AT ALL ACCESSIBLE PARKINGSTALLS. SPACES DESIGNATED FOR VAN PARKINGSHALL HAVE ADDITIONAL SIGN "VAN ACCESSIBLE"MOUNTED BELOW.5'-0"6"MAXABCONCRETE SIDEWALKASPHALT PAVINGNOTE:CURB RAMP VERTICAL RISE SHALLBE 6" MAX., PER IBC SECTION 1012NORTHWWW.NELSONWORLDWIDE.COMNelson Architecture & Interiors, Inc.1200 Fifth Ave., Suite 1300Seattle, WA 98101Phone: (206) 408-8500Reviewed By:Proj #:KEY PLAN:(AREA NOT IN SCOPE)PROJECT DIRECTORY:PROLOGIS12720 GATEWAY DR. SUITE 110TUKWILA, WA 98168TEL: (206) 414-7625ARCHITECT OF RECORD:NELSON WORLDWIDEATTN: Jennifer Wyman1200 5TH AVENUE SUITE 1300SEATTLE, WA 98101TEL: (206) 408-8500EMAIL: jwyman@nelsonww.comGENERAL CONTRACTOR:BNBUILDERSATTN: DAN HUBER2601 4TH AVENUE #350SEATTLE, WA 98121TEL: (206) 382-3443EMAIL: dan.huber@bnbuilders.comSTRUCTURAL ENGINEER:KPFFATTN: ERIK LOFTHUS1601 5TH AVENUE, SUITE 1600SEATTLE, WA 98101TEL: (206) 622-5822EMAIL: Erik.Lofthus@kpff.com2/11/2021 11:34:19 AM C:\Users\KJones\Documents\My Revit Projects\2019\20.0004357.000-SEA124 - Monster Rd_kevansKJ5TB.rvtAN.05SITE PLANTENANT IMPROVEMENTBUILDOUT601 MONSTER RD SWRENTON, WAChecker20.0004357.000MONSTER ROAD1/32" = 1'-0"AN.05SITE AND ROOF PLAN1Issue: No: Date:ISSUE FOR PERMIT 02.12.20211/8" = 1'-0"AN.05ENLARGED SITE PLAN21/4" = 1'-0"AN.05ENLARGED SITE PLAN - EV CHARGER53/4" = 1'-0"AN.05ACCESSIBLE PARKING SIGNAGE41/2" = 1'-0"AN.05ACCESSIBLE RAMP CURB3