HomeMy WebLinkAboutP_TIPlanForReference_210217_v1WH
DN
AV
AV
FEC
FECFEC
FECFECFEC
FEC
FEC
FEC FEC
UP
FEC
EGRESS AND LIFE SAFETY NOTES
GENERAL NOTES
1. EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT
SPECIAL KNOWLEDGE, EFFORT OR THE USE OF A SPECIAL KEY OR LATCH.
2. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING
AN OCCUPANT LOAD OF 50 OR MORE OR AN "H" OCCUPANCY.
3. UNLATCHING FORCE OF PANIC HARDWARE SHALL NOT EXCEED 15 POUNDS
WHEN APPLIED IN THE DIRECTION OF TRAVEL.
4. MEANS OF EGRESS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS
OCCUPIED WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE
FOOT CANDLE AT WALKING SURFACE LEVEL EXIT ILLUMINATION FIXTURES
SHALL BE ON A SEPARATE NIGHT LIGHT CIRCUIT WITH BATTERY BACK-UP
EXIT ILLUMINATION SHALL BE PROVIDED FOR NOT LESS THAN 90 MINUTES
VIA STORAGE BATTERIES, OR ON-SITE GENERATOR.
5. CORRIDORS SHALL BE MAINTAINED WITH A MINIMUM CLEAR WIDTH OF 44"
AND 7'-6" MINIMUM HEIGHT.
6. EXIT DOORS SHALL BE A MINIMUM OF 32" CLEAR WIDTH & MAXIMUM 48"
WIDE LEAF. MINIMUM 6'-8" DOOR HEIGHT.
7. DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED CORRIDOR
EXIT WIDTH BY MORE THAN HALF.
8. MAIN EXIT DOORS WITHOUT PANIC HARDWARE SHALL HAVE A SIGN WITH
LETTERS ON A CONTRASTING BACKGROUND STATING: “THIS DOOR TO
REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED”
9. EXIT ACCESS HAS BEEN BASED UPON PROGRAM INFORMATION PROVIDED
TO NELSON BY THE INTENDED OCCUPANT OF THIS SPACE. ARCHITECT
SHALL NOT BE HELD RESPONSIBLE FOR ANY CONSEQUENCES WHICH
MAY RESULT FROM THE CHANGE OF USE OR OCCUPANT LOAD AFTER
PROJECT COMPLETION.
10. TACTILE EXIT SIGNAGE SHALL BE REQUIRED. TACTILE SIGNS SHALL BE
MATTE FINISH, WITH CHARACTERS THAT CONTRAST WITH THE
BACKGROUND. SUBMIT SIGN SAMPLE TO ARCHITECT FOR APPROVAL.
FINISHES: 1/4" P95 BACKPAINTED ACRYLIC. PAINT: MANUFACTURER,
COLOR. COLOR (ROWMARK) APPLIQUE WITH CLASSIC RASTER BRAILLE.
PROVIDE SIGNS AT THE FOLLOWING LOCATIONS:
A. EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY
A TACTILE SIGN WITH THE WORD "EXIT".
B. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL
EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE
IDENTIFIED BY A TACTILE SIGN WITH THE FOLLOWING WORDS,
"EXIT STAIR DOWN", "EXIT RAMP DOWN", EXIT STAIR UP", OR "EXIT
RAMP UP".
C. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL
EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT
PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH
THE WORDS, "EXIT ROUTE".
D. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM, OR AREA TO A
CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT
SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE
WORDS, "EXIT ROUTE".
E. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE
IDENTIFIED BY A SIGN WITH THE WORDS, "TO EXIT".
11. SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF SINGLE DOOR AND RIGHT
SIDE OF DOUBLE DOORS FROM DIRECTION OF EGRESS.
12. SIGNAGE AND TACTILE FLOOR DESIGNATIONS SHALL BE LOCATED AT EACH
STAIR IDENTIFYING EACH STAIR BY NAME OR NUMBER.
13. FOR A-3 OCCUPANCIES PROVIDE SIGNAGE POSTING THE ROOM CAPACITY.
14. SIGNAGE AND TACTILE SIGNAGE SHALL BE LOCATED AT EACH DELAYED
EGRESS LOCK READING "KEEP PUSHING. THIS DOOR WILL OPEN IN 15
SECONDS. ALARM WILL SOUND."
15. SIGNAGE AND TACTILE SIGNAGE SHALL BE PROVIDED AT EACH EXIT DOOR
WITH DELAYED EGRESS LOCK, AND SHALL BE LOCATED ABOVE AND WITHIN
12" OF DOOR EXIT HARDWARE.
A. FOR DOORS THAT SWING IN THE DIRECTION OF EGRESS, THE SIGN
SHALL READ "KEEP PUSHING. THIS DOOR WILL OPEN IN 15
SECONDS. ALARM WILL SOUND."
B. FOR DOORS IN THE OPPOSITE DIRECTION OF EGRESS, THE SIGN
SHALL READ "KEEP PULLING. THIS DOOR WILL OPEN IN 15 SECONDS.
ALARM WILL SOUND."
16. SIGNAGE AND TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT AND
ELEVATOR SERVING A REQUIRED ACCESSIBLE SPACE. SIGNAGE SHALL
BE INSTALLED INDICATING THE LOCATION OF ACCESSIBLE MEANS OF
EGRESS.
17. EXITS IN EXCESS OF THOSE REQUIRED BY THE CODE WITHOUT A RAMP
AND MORE THAN 24" ABOVE GRADE SHALL HAVE SIGNS "EXIT STAIR
DOWN"
18. EXIT SIGNAGE SHALL BE INTERNALLY ILLUMINATED AT ALL TIMES WITH
EMERGENCY ELECTRICAL BACK-UP POWER.
19. EXIT SIGN ILLUMINATION SHALL NOT BE LESS THAN 5 FOOT CANDLES EXIT
SIGNS SHALL HAVE TWO POWER SOURCES, ONE FROM THE PREMISES
WIRING SYSTEM, THE OTHER FROM BATTERIES.
20. FINAL PLACEMENT OF EXIT SIGNS IS SUBJECT TO APPROVAL AND
MODIFICATION OF THE FIRE DEPARTMENT FIELD INSPECTOR.
21. REFER TO TACTILE SIGNAGE DETAIL _______.
TENANT GROSS FLOOR AREA - LEVEL 01:
OCCUPANT FLOOR AREAS: OCCUPANCY FLOOR AREA TABLE BELOW
CODE ANALYSIS - LEVEL 1
GROSS FLOOR AREA - LEVEL 01:164,480 SF
EXITING PROVIDEDREQUIRED
EXIT WIDTH - OTHER EGRESS
COMPONENTS:
0.15" X OCC LOAD [W/ SPRINKLERS]
0.15" X 504=75.6"
ARTICLE 1005.3.2
36" X 10 = 360"
72" X 1 = 72"
[TOTAL DOOR EXIT WIDTH=432"]
NUMBER OF EXITS:
GROUPS B & S-1
11
TABLE 1006.2.1 &
TABLE 1006.3.1
501 - 1000 OCC LOAD = 3 EXITS
COMMON PATH OF EGRESS:
GROUP B & S-1
SEPARATION OF EXITS:463'-9"
EXIT ACCESS TRAVEL DISTANCE:
GROUP B & S-1
SECTION 1007
TABLE 1017.2
100' MAX. W/ SPRINKLERS
MIN 1/3 MAX OVERALL DIAGONAL
DIM OF SPACE SERVED W/ SPR
622'-7"/3 = 207'-6"
B: 300' W/ SPRINKLERS
S-1: 250' W/ SPRINKLERS
65'-10"
48'-0"
91,160 SF
ROOM / AREA NAMEFLOOR AREAFUNCTION OF SPACE (TABLE 1004.1.2)SQ. FT. PEROCCUPANT (TABLE 1004.1.2)MAX. OCCUPANTLOADOCCUPANCY CLASSIFICATION(SEC 303-312) ACCESSORY USE / % FLOOR AREABREAKROOM 15 SF 133
YES /
2.8%
NO
1ST FLOOR
SMALL ASSEMBLY 15 SF 18
A-3
A-3 AS
ACCESSORY TO B
2,002 SF
275 SF
15 SF 36540 SF
BREAK ROOM
CONFERENCE ROOM
RECEPTIONROOM #104
114
145 SMALL ASSEMBLY YES /
5.6%
OFFICE/
REPROGRAPHICS
WAREHOUSE
-
-
9,651 SF BUSINESS 150 SF 64 B
75,802 SF STORAGE/ SHIPPING 300 SF 253 S-1
8.4%TOTAL 504
PLUMBING FIXTURE REQUIREMENTS
OCCUPANCY
USE LOAD
WATER CLOSETS / URINALS
RATIO MALE
(50%)
FEMALE
(50%)
SINGLE
OCCUPANCY RATIO
LAVATORIES DRINKING FOUNTAIN
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
WAREHOUSE
(S-1)1 PER 100
SUBTOTALS
TOTAL REQUIRED
TOTAL PROPOSED
1. WHERE DRINKING FOUNTAIN ARE REQUIRED, NOT FEWER THAN TWO DRINKING FOUNTAIN
SHALL BE PROVIDED. HIGH & LOW TO COMPLY WITH ICC/ ANSI 117.1-2009
2. A SINGLE DRINKING FOUNTAIN WITH TWO SEPARATE SPOUTS (HIGH-LOW) CAN SUBSTITUTE
TWO SEPARATE DRINKING FOUNTAINS.
3. WATER DISPENSERS SHALL BE PERMITTED TO SUBSTITUTE MAXIMUM 50% OF THE DRINKING
FOUNTAINS.
4. DRINKING FOUNTAIN IS NOT REQUIRED IN RESTAURANTS SERVING WATER IN CONTAINERS.
--
MALE
(50%)
SINGLE
OCCUPANCY
FEMALE
(50%)
--
1 PER 75 PER
GENDERASSEMBLY
(A-3)
RATIO REQUIRE
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
133
253
1.77
1.27
1.77
1.27
4.86 4.86
5 5
9 10
1 PER 200
1 PER 100
.5 .5
3.1 3.1
4 4
7 8
1 PER 500
1 PER 1000
0.27
0.25
2
4
A-3 AS
ACCESSORY TO B
NO
NO
OCCUPANT LOAD (USABLE SF) - LEVEL 01:
88,270 SF
TENANT GROSS FLOOR AREA - LEVEL 01:
OCCUPANT FLOOR AREAS: OCCUPANCY FLOOR AREA TABLE BELOW
CODE ANALYSIS - MEZZANINE
GROSS FLOOR AREA - LEVEL 01:2,963 SF
EXITING PROVIDEDREQUIRED
EXIT WIDTH - OTHER EGRESS
COMPONENTS:
0.15" X OCC LOAD [W/ SPRINKLERS]
0.15" X 14 =2.1"
ARTICLE 1005.3.2
36" X 2 = 72"
[TOTAL DOOR EXIT WIDTH=72"]
NUMBER OF EXITS:
GROUPS B
2
TABLE 1006.2.1 &
TABLE 1006.3.1
1 - 500 OCC LOAD = 2 EXITS
COMMON PATH OF EGRESS:
GROUP B
SEPARATION OF EXITS:61'-10"
EXIT ACCESS TRAVEL DISTANCE:
GROUP B
SECTION 1007
TABLE 1017.2
100' MAX. W/ SPRINKLERS
MIN 1/3 MAX OVERALL DIAGONAL
DIM OF SPACE SERVED W/ SPR
79'-5"/3 = 26'-6"
300' W/ SPRINKLERS 99'-3"
40'-0"
2,963 SF
ROOM / AREA NAMEFLOOR AREAFUNCTION OF SPACE (TABLE 1004.1.2)SQ. FT. PEROCCUPANT (TABLE 1004.1.2)MAX. OCCUPANTLOADOCCUPANCY CLASSIFICATION(SEC 303-312) ACCESSORY USE / % FLOOR AREAMEZZANINE
ROOM #OFFICE-2,152 SF BUSINESS 150 SF 14 B
TOTAL 14
NO
OCCUPANT LOAD (USABLE SF) - LEVEL 01:
2,152 SF
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
1 PER 25
FIRST 50;
THEN 1 PER 50
EXCEEDING 50
BUSINESS
(B)
OCCUPANT
LOADS OF 15
OR LESS CAN
BE SERVED
WITH ONE
RESTROOM
132 1.82 1.82
1 PER 40
FIRST 80;
THEN 1 PER 80
EXCEEDING 80
1.33 1.33
1 PER 100
1.32
1.27 1.27
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
G
C.2
770 SF
ELEC
153
275 SF
MEDIUM CONF.
156
448 SF
VESTIBULE
155
118 SF
SERVER ROOM
154
156 SF
OFFICE
143
1929 SF
SCAN
145
2219 SF
STAGING
125
1206 SF
RESEARCH
123
8793 SF
SORT
144 6073 SF
VESTIBULE
122
5637 SF
COPY PRINT
110
156 SF
TEAM ROOM
113
102 SF
TEAM ROOM
115
101 SF
SHARED OFFICE
116
127 SF
MOTHER'S RM
117
101 SF
OFFICE
118
183 SF
COPY/ PRINT
109
69 SF
SHARED OFFICE
108
69 SF
SHARED OFFICE
107
310 SF
SERVICE AREA
106
298 SF
VESTIBULE
105
513 SF
RECEPTION
101
584 SF
OFFICE
121
97 SF
SHARED OFFICE
120
95 SF
SHARED OFFICE
119
101 SF
SUPPLY
102
55 SF
STORAGE
103
65 SF
RESTROOM
104
832 SF
CORRIDOR
112
2002 SF
BREAKROOM
165
666 SF
BLDG STOR
164
306 SF
ELEC
163
290 SF
FIRE RISER
162
214 SF
ENTRY
151
396 SF
NETWORK
150
598 SF
BLDG STORAGE
148
869 SF
MECH RM
147333 SF
GENERATOR RM
146
1459 SF
CORRIDOR
111
20471 SF
WAREHOUSE STORAGE
139 1305 SF
ARCHIVE
142
164 SF
NETWORK
141
78 SF
ENTRY
140
974 SF
OUTBOUND
136
2855 SF
INBOUND
138
1154 SF
INBOUND
134
3452 SF
INBOUND
131
1892 SF
OUTBOUND
132
4470 SF
OUTBOUND
133
1522 SF
OUTBOUND
135
2996 SF
SCANNING
127
2258 SF
VESTIBULE
126
64 SF
ENTRY
129
84 SF
NETWORK
130
428 SF
WOMEN'S RESTROOM
161
426 SF
MEN'S RESTROOM
160
174 SF
JANITOR
159
93 SF
RESTROOM
158
95 SF
RESTROOM
157
365 SF
PASSAGE
170
SMALL ASSEMBLY
270 SF
15 SF/OCCUPANT
ASSEMBLY
OCCUPANCY
2002 SF
15 SF/OCCUPANT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT EXIT
ASSEMBLY
ACCESSORY TO
B OCCUPANCY
540 SF
15 SF/OCCUPANT
EXIT
EXIT SEPARATION +/-463'-9"
COMMON PATH OF EGRESS +/-
32' - 3" [100' ALLOWED]
MAX EXIT TRAVEL +/- 65' - 10"
[250 ALLOWED]
COMMON PATH OF EGRESS +/- 7' - 8"
[100' ALLOWED]
MAX EXIT TRAVEL +/- 51' - 1" [250
ALLOWED]
COMMON PATH OF EGRESS
+/- 48' - 0" [100' ALLOWED]
MAX EXIT TRAVEL +/- 102' - 0"
[300 ALLOWED]
COMMON PATH OF EGRESS +/- 25 - 6"
[100' ALLOWED]
MAX EXIT TRAVEL +/- 131' - 3" [250
ALLOWED]
311 SF
SECURE SHELVING
124
155 SF
TRASH
114
151 SF
STORAGE
128
2008 SF
IMAGING
137
1438 SF
CORRIDOR
152
FE
EXIT DOOR
COMMON PATH OF TRAVEL
EXIT ACCESS TRAVEL
LIFE SAFETY LEGEND
EXIT SIGN
EXIT SEPARATION
SPACE DIAGONAL
EXIT
FIRE
or
FIRE MARSHALL ENTRY DOOR
NOT IN SCOPE
FIRE RATED PARTITION
6 7 8 9
A
B
C
D
C.2
2952 SF
MEZZANINE
201
67' - 8"
EXIT SEPARATION +/-61'-10"
COMMON PATH OF EGRESS +/- 40 - 0"
[100' ALLOWED]
MAX EXIT TRAVEL +/- 99' - 3" [300
ALLOWED]
NORTH
WWW.NELSONWORLDWIDE.COM
Nelson Architecture & Interiors, Inc.
1200 Fifth Ave., Suite 1300
Seattle, WA 98101
Phone: (206) 408-8500
Reviewed By:Proj #:
KEY PLAN:
(AREA NOT IN SCOPE)
PROJECT DIRECTORY:
PROLOGIS
12720 GATEWAY DR.
SUITE 110
TUKWILA, WA 98168
TEL: (206) 414-7625
ARCHITECT OF RECORD:
GENERAL CONTRACTOR:
BNBUILDERS
ATTN: DAN HUBER
2601 4TH AVENUE #350
SEATTLE, WA 98121
TEL: (206) 382-3443
EMAIL:
dan.huber@bnbuilders.com
STRUCTURAL ENGINEER:
KPFF
ATTN: ERIK LOFTHUS
1601 5TH AVENUE, SUITE 1600
SEATTLE, WA 98101
TEL: (206) 622-5822
EMAIL: Erik.Lofthus@kpff.com
2/12/2021 1:55:20 PMC:\Users\AMansour\Documents\My Revit Projects\2019\20.0004357.000-SEA124 - Monster Rd_AMansour.rvtAN.01
LIFE SAFETY PLAN
TENANT IMPROVEMENT
BUILDOUT
601 MONSTER RD SW
RENTON, WA
Checker20.0004357.000
MONSTER ROAD
1" = 20'-0"AN.01
LIFE SAFETY PLAN - LEVEL 11
1" = 20'-0"AN.01
LIFE SAFETY PLAN - MEZZANINE2
Issue: No: Date:
ISSUE FOR PERMIT 02.12.2021
NELSON WORLDWIDE
- ADAM SEGALLA, AOR
ATTN: KIRSTEN JONES
1200 5TH AVENUE SUITE 1300
SEATTLE, WA 98101
TEL: (206) 408-8515
EMAIL: KJones@nelsonww.com