HomeMy WebLinkAboutPRE_Meeting SummaryPREAPPLICATION MEETING FOR
601 Monster Rd Tenant Improvements
PRE 20-000299
CITY OF RENTON
Department of Community & Economic Development
Planning Division
January 7, 2021
Contact Information:
Planner: Jill Ding, 425.430.6598, jding@rentonwa.gov
Public Works Plan Reviewer: Brianne Bannwarth, 425-430-7299,
bbannwarth@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 425.430.7235
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
formal submittal.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
Monster Road Building Tenant Improvement
PRE20-000299
Page 1 of 4
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: January 6, 2021
TO: Jill Ding, Senior Planner
FROM: Brianne Bannwarth, Development Engineering Manager
SUBJECT: Monster Road Building Tenant Improvement
601 Monster Road SW
PRE20-000299
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel 2423049008.
The following comments are based on the pre-application submittal made to the City of Renton by the
applicant.
Water
1. The project is within the City’s water service area in the 196-hydraulic pressure-zone. The site is
outside of the City’s wellhead protection areas.
2. The static water pressure is approximately 70 psi at ground elevation of 404 feet.
3. There is an existing 12-inch water main surrounding the existing building that can deliver a maximum
flow capacity of 4,000 GPM (see water plan no. W-4042).
4. There is an existing 16-inch water main located in Union Ave NE that can deliver a maximum flow
capacity of 5,700 GPM (see water plan no. W-024502).
5. There is an existing 2-inch domestic water meter serve with a 2-inch RPBA that is intended to serve
the existing tenant space (see water plan W-404203).
Monster Road Building Tenant Improvement
PRE20-000299
Page 2 of 4
6. Based on the information provided with the pre-application submittal documents, no additional water
main improvements are anticipated. If changes are made to the scope of the proposal, additional
requirements may apply.
Monster Road Building Tenant Improvement
PRE20-000299
Page 3 of 4
Sanitary Sewer
1. The project is within the City of Renton’s sanitary sewer service area.
2. There is an 8-inch gravity wastewater main located in Union Ave NE (see record drawing S-015201).
3. There is an existing 8-inch sewer service to the existing building (see sewer plan S-404203).
4. If manufacturing that is proposed, an oil/water interceptor or grease interceptor may be required on
the side sewer service line depending on the type of manufacturing. A grease interceptor shall be
sized in accordance with standards found in the latest edition of the Uniform Plumbing Code (UPC).
The grease interceptor shall drain by gravity to the sewer main and shall be located so that it is
accessible for routine owner maintenance.
5. Based on the information provided with the pre-application submittal documents, no additional
sewer improvements are anticipated. If changes are made to the scope of the proposal, additional
requirements may apply.
Surface Water
1. There is an existing private on-site conveyance system serving the property (see construction drawing
R-4042).
2. Based on the information provided with the pre-application submittal documents, no additional storm
improvements are anticipated. If changes are made to the scope of the proposal, additional
requirements may apply.
Transportation
1. Based on the information provided with the pre-application submittal documents, no additional
transportation improvements are anticipated. If changes are made to the scope of the proposal,
additional requirements may apply.
Monster Road Building Tenant Improvement
PRE20-000299
Page 4 of 4
2. Transportation Impact Fees were paid as part of the Core and Shell Permit for the existing Building.
The Transportation Impact Fees were assessed as warehouse use. If this use changes from this
assessment, additional fees may apply.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: January 7, 2021
TO: Pre-Application File No. PRE20-000299
FROM: Jill Ding, Senior Planner
SUBJECT: 601 Monster Rd Tenant Improvement
601 Monster Rd SW
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other
design changes required by City staff or made by the applicant. The applicant is encouraged to
review all applicable sections of the Renton Municipal Code. The Development Regulations are
available online at www.rentonwa.gov
Project Proposal: The subject property is located at 601 Monster Rd SW at the southwest corner
of Monster Rd SW and Monster Rd SW. The project site totals 418,876 square feet and is zoned
IM. The applicant is proposing a 91,800 square foot tenant improvement within an existing
164,480 square foot industrial building permitted under 601 Monster Rd (LUA18-000234). The
proposed tenant improvement space would be utilized for industrial warehouse/storage (67,609
sq. ft.), office (6,789 sq. ft.) and assembly (2,484 sq. ft.) and factory (13,968 sq. ft.) areas. No
exterior changes to the site or access are proposed. The site is mapped with flood hazard areas,
sensitive and protected slopes, coal mine hazards, and a seismic hazard area.
Current Use: The subject site is currently occupied with a 164,480 square foot industrial
building.
Zoning: The subject site is located within the Medium Industrial (IM) zoning designation. The
site is also located within the Employment Area Valley Comprehensive Plan designation. Light
manufacturing and fabrication, office uses, and warehouse uses are outright permitted uses
within the IM zone. More information is required regarding the proposed assembly and
factory uses to ensure that the proposed uses meet the definition of light manufacturing and
fabrication and are permitted uses.
601 Monster Rd TI
Preapplication Meeting
January 7, 2021
Development Standards: The project would be subject to RMC 4-2-130A, “Development
Standards for Industrial Zoning Designations” (noted as “IM standards” herein). These
standards are available online.
Minimum Lot Size, Width and Depth – There are no minimum requirements for lot width or
depth within the IM zone, however, there is a minimum lot size requirement of 35,000 square
feet. No changes to existing lot dimensions are proposed.
Lot Coverage – There is no minimum lot coverage requirement within the IM zone, except for
the limitations imposed by the City’s landscaping requirements. No changes to the existing
building footprint are proposed.
Setbacks – Setbacks are the distance between the building and the property line or any private
access easement. The required setbacks in the IM zone for properties not next to a Principal
Arterial or residential properties are as follows: 15 feet for a front yard and side yard along a
street; zero for the rear yard; zero for the interior side yards; and a 10-foot landscaped setback
is required from a freeway. No exterior additions to the building are proposed.
Building Height – There is no maximum building height requirement within the IM zone.
Parking – Parking for vehicles and bicycles, loading areas, and driveways shall be provided
in accordance with the provisions of the current parking regulations of RMC 4-4-080,
“Parking, Loading, and Driveway Regulations.”
The following ratio would be applicable to the site:
Use Ratio Square footage proposed Required
Spaces
Manufacturing
and
fabrication,
laboratories,
and assembly
and/or
packaging
operations
A minimum of
1.0 per 1,000
square feet of
net floor area
and a maximum
of 1.5 spaces per
1,000 square feet
of net floor area
(including
warehouse
space).
16,452 sq. ft. 16-25
Office A minimum of 2.0
per 1,000 square
feet of net floor
area and a
maximum of 4.5
parking spaces
per 1,000 square
feet of net floor
area.
6,789 sq. ft. 14-31
601 Monster Rd TI
Preapplication Meeting
January 7, 2021
Warehouse A minimum and
maximum of 1 per
1,500 square feet
of net floor area.
67,609 sq. ft. 101
Based on the square footages proposed, the proposal would be required to provide 131-157
parking spaces. The applicant would be required to provide a parking study at the time of
formal land use/building permit application demonstrating compliance with the required
parking. It should be noted that the parking regulations specify standard stall dimensions.
Surface parking stalls must be a minimum of 9 feet x 20 feet, compact dimensions of 8½ feet x
16 feet, and parallel stall dimensions of 9 feet x 23 feet; compact surface parking spaces shall
not account for more than 30 percent of the spaces in the surface parking lots.
ADA accessible stalls must be a minimum of 8 feet in width by 20 feet in length, with an adjacent
access aisle of 8 feet in width for van accessible spaces. The required number of ADA accessible
stalls, based on the total number of spaces, must be provided.
Bicycle parking shall be provided in compliance with RMC 4-4-080F.11, at a rate of 10 percent
of the number of required parking spaces. Bicycle parking shall be provided for secure
extended use and shall protect the entire bicycle and its components and accessories from
theft and weather. Acceptable examples include bike lockers, bike check-in systems, in-
building parking, and limited access fenced areas with weather protection.
Landscaping – Except for critical areas, all portions of the development area not covered by
structures, required parking, access, circulation or service areas, must be landscaped with
native, drought-resistant vegetative cover. Please refer to landscape regulations (RMC 4-4-070
and RMC 4-4-080F.7) for further general and specific landscape requirements. Ten feet (10') of
on-site landscaping is required along all public street frontages, with the exception of areas for
required walkways and driveways.
Surface parking lots with 15-50 parking spaces are required to provide 15 square feet of interior
parking lot landscaping per parking space, as specified below:
Interior Parking Lot Landscaping: Any interior parking lot landscaping area shall be a minimum
of eight feet (8') in width and 12’ deep. Landscaping shall be dispersed throughout the parking
area and shall include a mixture of trees, shrubs, and groundcover as follows:
a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi-family, commercial,
and industrial uses. At least one tree for every six (6) parking spaces within the lot interior shall
be planted.
b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped area shall be
planted. Up to fifty percent (50%) of shrubs may be deciduous.
c. Ground cover shall be planted in sufficient quantities to provide at least ninety percent (90%)
coverage of the landscaped area within three (3) years of installation.
d. There shall be no more than fifty feet (50') between parking stalls and an interior parking lot
landscape area.
Perimeter parking lot landscaping is required, as specified below:
Perimeter Parking Lot Landscaping: Such landscaping shall be at least ten feet (10') in width as
measured from the street right-of-way. Standards for planting shall be as follows:
601 Monster Rd TI
Preapplication Meeting
January 7, 2021
a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi-family, commercial,
and industrial uses at an average minimum rate of one tree per thirty (30) lineal feet of street
frontage.
b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped area. Up to fifty
percent (50%) of shrubs may be deciduous.
c. Ground cover in sufficient quantities to provide at least ninety percent (90%) coverage of the
landscaped area within three (3) years of installation.
Please refer to landscape regulations (RMC 4-4-070) for further general and specific landscape
requirements. The applicant has indicated that the proposal would not result in changes to the
existing onsite landscaping.
Refuse and Recycling Areas – Refuse and recycling areas need to meet the requirements of
RMC 4-4-090, “Refuse and Recyclables Standards.” For office, educational, and institutional
developments, a minimum of 2 sq. ft. for every 1,000 sq. ft. of building gross floor area
shall be provided for recyclable deposit areas and a minimum of 4 sq. ft. for every 1,000 sq.
ft. of building gross floor area shall be provided for refuse deposit areas with a total
minimum area of 100 sq. ft.. Required location criteria and screening are provided in the
code section. The applicant would be required to provide 184 square feet of recyclable
deposit areas and 367 square feet of refuse deposit areas, compliance with the refuse and
recyclable deposit area standards would be verified at the time of formal land
use/building permit review.
Screening – Screening must be provided for all surface-mounted and roof top utility and
mechanical equipment. Screening regulations are detailed in RMC 4-4-095.
Fences – If the applicant intends to install any fences as part of this project, the location must be
designated on the landscape plan. All existing fences and security gates should be depicted on
the site survey and include type of fence, material, and height. A fence detail should also be
included on the landscape plan as well for new proposed fencing.
Lighting – New parking lot and building lighting would require a lighting plan and shall meet the
lighting standards (RMC 4-4-075).
Access: Access to the subject site is proposed to remain in its current configuration via curb cuts
off of Monster Rd SW.
Significant Tree Retention: If tree removal is proposed, a tree inventory and a tree retention
plan along with a tree retention worksheet shall be provided with the formal land use
application. According to the proposed regulations, the tree retention plan must show
preservation of at least 10 percent (10%) of significant trees and indicate how proposed building
footprints would be sited to accommodate preservation of significant trees that would be
retained. The Administrator may authorize the planting of replacement trees on the site if it can
be demonstrated to the Administrator’s satisfaction that an insufficient number of trees can be
retained.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees
on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their
associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen
inches ( 18") caliper.
601 Monster Rd TI
Preapplication Meeting
January 7, 2021
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and Other significant non- native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods
are used as part of an approved enhancement project within a critical area or its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City’s discretion.
Critical Areas: The site is mapped with flood hazard areas, sensitive and protected slopes, coal
mine hazards, and a seismic hazard area. No critical areas reports would be required as all
proposed improvements would be interior to the existing building.
Environmental Review: The proposal would be subject to Environmental (SEPA) Review as the
proposal includes the change of use to an existing building larger than 4,000 sf.
Permit Requirements: The proposed project would require Environmental (SEPA) Review.
Environmental (SEPA) Review would be processed within an estimated time frame of 6-8 weeks.
The current application fees would total $1,680 ($1,600 SEPA Review + $80 technology fee =
$1,680), all fees are subject to change. Detailed information regarding the land use application
submittal is available online at www.rentonwa.gov. In addition to the required land use
permits, separate construction and building permits would be required.
Impact Mitigation Fees: In addition to the applicable building and construction fees, the
following impact fees would be required prior to the issuance of building permits.
A Fire Mitigation fee based on the rate established by the Renton Fire Authority would
be assessed.
A Transportation Mitigation Fee based on the fee established in the ITE manual would
be required.
Note: When the formal application materials are complete, the applicant is strongly
encouraged to have one copy of the application materials pre-screened prior to submitting
the complete application package. Please contact Jill Ding, Senior Planner at 425 -430-6598 or
jding@rentonwa.gov for an appointment.