Loading...
HomeMy WebLinkAboutP_Floor Plans_Middleby_210222_v1.pdfUP UP DN DN JANITOR ELEV. MECH ELEV WOMEN 114 MEN 115 OFFICE 102 [PAULA] OFFICE 103 [ERIKA] OFFICE 104 [WAYNE] OFFICE 105 [NIELS] OFFICE 106 [MARK B.]CUBE [ERIC GLENN PAUL RACHEL] CUBE [PRABH] CUBE [HANNAH] OFFICE 110 [TYLER G.] ENGINEERING LAB 108 SHOWROOM 101 CUBE [MONISHA] CUBE [QUAN] CUBE [TOMAS] CUBE [LEAH] CUBE CAROL S.] CUBE [HOLLY K.] CUBE [ALEX] CUBE [SHRUTI] CUBE [TERESA K.]OFFICE 203 [OPEN] OFFICE 204 [SARAH] OFFICE 205 [LISA] OFFICE 206 [ROBIN] COPIER/ SUPPLIES 211 STORAGE ELEV WOMEN 214 MEN 215STORAGE CONFERENCE 201 SHARED OFFICE 216 [ANGIE P., JANICE] 2'-0" 19'-0"17'-8 1/8"2'-0"11'-1"12'-0 1/4"17'-2"11'-1"13'-2"11'-1"13'-2"11'-1"12'-6" 31'-4"25'-4"18'-11 3/8"19'-0"16'-7 5/8"16'-4 3/8"21'-10 5/8"11'-0"11'-1"11'-0"11'-6"10'-8 3/4"11'-1"11'-1"11'-1"CUBE [OPEN] CHECK-IN AREA 100 31'-4"46'-7"1. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONFLICTS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE START OF CONSTRUCTION. 2. NOT ALL KEYNOTES ON EACH SHEET. 3. DO NOT MEASURE DRAWINGS TO DETERMINE OMITTED DIMENSIONS, CONTACT ARCHITECT. 4. DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE 4" & 4 1/2" (METAL WALLS & WOOD WALLS, RESPECTIVELY) FROM EDGE OF DOOR OPENING TO FINISH FACE OF ADJACENT WALL. 5. PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE STOPPED. 6. IN ALL COMMON SPACES AND ADA ROOMS, ALL LIGHTING CONTROLS, ELECTRICAL PANELBOARDS, ELECTRICAL SWITCHES AND RECEPTACLE OUTLETS, ENVIRONMENTAL CONTROLS, APPLIANCE CONTROLS, OPERATING HARDWARE FOR OPERABLE WINDOWS, PLUMBING FIXTURE CONTROLS, AND USER CONTROLS FOR SECURITY SHALL BE MOUNTED PER ANSI REQUIREMENTS. 7.ALL NEW INTERIOR WALLS TO BE FLOOR TO CEILING GRID. 8.ALL FIREWALL RATINGS SHALL BE MAINTAINED AT STAIRS, ELEVATOR SHAFTS AND ELEVATOR MECHANICAL ROOM. PROPOSED FLOOR PLAN NOTES: TESTING 109 TECH TRAINING 113 LUNCH ROOM 112 CUBE [MATT] CUBE [BRENDA] CUBE [DAVID] SERVER 111 CUBE [OPEN] CUBE [OPEN] CUBE [OPEN] CUBE [OPEN]OFFICE 208 [OPEN] OFFICE 209 [OPEN] 12'-10 7/8"10'-1 1/2"10'-1 1/2"54'-11 5/8" 5'-0" 4'-0" 7'-1 1/8"19'-7 1/4"21'-0"26'-5 1/2"27'-1 7/8" OPEN OFFICE 107 HALLWAY 116 HALLWAY 200 OPEN OFFICE 202 OPEN OFFICE 207 OPEN OFFICE 210 CONFERENCE 212 20'-9"31'-4" 20'-0"9'-0"23'-1 1/2"12'-6"15'-10"12'-6" PLUMBING CALCULATIONS: 2015 INTERNATIONAL BUILDING CODE, CHAPTER 29 - PLUMBING SYSTEMS TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES OCC. B TOTAL OCCUPANTS = 108 108/2 = 54 MEN AND 54 WOMEN REQUIRED PROVIDED PLUMBING FIXTURES MALE FEMALE WATER CLOSETS LAVATORIES OCC. F-2 TOTAL OCCUPANTS = 273 273/2 = 137 MEN AND 137 WOMEN REQUIRED PROVIDED MALE FEMALE OCC. S TOTAL OCCUPANTS = 138 138/2 = 69 MEN AND 69 WOMEN REQUIRED PROVIDED MALE FEMALE WATER CLOSETS LAVATORIES WATER CLOSETS LAVATORIES 4 3 2 2 2 1 3 3 2 2 PLUMBING CALCULATIONS: 2015 INTERNATIONAL BUILDING CODE, CHAPTER 29 - PLUMBING SYSTEMS TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES OCC. B TOTAL OCCUPANTS = 100 108/2 = 50 MEN AND 50 WOMEN REQUIRED PROVIDED PLUMBING FIXTURES MALE FEMALE WATER CLOSETS LAVATORIES 4 3 2 2 2 1 C:\Users\imiakota\Desktop\concordia_logo.gif DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"CONCORDIA TI851 SW 34th St,Renton, WA 98057: 253-272-4214 NOT F O R CONS T R U C TI O N#/ / : : + + A1.0 PROGRAMMING 1 SCALE: FIRST FLOOR PLAN 1/8" = 1'-0"1 SCALE: SECOND FLOOR PLAN 1/8" = 1'-0"2