HomeMy WebLinkAboutMFP21000637.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP21000637 IVR Number: 21000637 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:02/11/2021Application Date:7231501970Parcel Number: 124 WILLIAMS AVE S Permit Type:03/02/2021Issue Date:Franchise Permit Work Class:03/02/2022Expiration Date:Minor Utility Job Number: 477863Franchise Type:Cable Description: Comcast to proof and pull RG 11 through existing conduit, dig and intercept and set vault, bore 39'. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Fahm Saelee Prince Telecom Applicant Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Akisha Brown Prince Telecom Inc 551A Mews Dr New Castle, DE 19720 B: (302) 482-8893 C: (302) 482-8892 Contractor Business License Number: 29850Electrical Contractor: PRINCTL834BF Construction Contractor: PRINCTL862PS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP21000637 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS Scott Warlick 3/2/2021 MFP21000637 Scott Warlick CED 3/2/2021 Date:ROW Aerial Project Manager:ROW Underground 65 Transport Aerial Legend SOW P2#Heavy# 477863 Route Overview Construction Notes: 1. Using 2" conduit placed for Job #353148 pull 136' RG-11 from available tap in vault. 2. Set vault during Job #353148 or dig and intercept and set vault. 3. Bore 39' to buildging with 2 concrete cuts (9x4) & (2x3). Pull Rg--11 4. Place 2" exterior molding, Core drill into ceiling space and pull 65' RG-11 to network closet. Project Name InControl 124 Williams Ae S, Renton Wa 98057Address Private Aerial Private UndergroundContractor Logo Prepared By:Scott Barker 2/10/2021 Sheet Number: 2 FootagesRev.Date ENGINEERED FOR: Route Overview Transport Underground 175 New Ped New Vault Existing U/G ExistingAerial New U/G New Aerial V Pole Lock Box Footage Text Box Callout Arrow New Tap Text 150' x 1 V 39'65' V136'Job in process #353148 Kristen Gulbrand Financial Adviser 1 2 3 4 Job in process #353148 Set vault to avoid dig and intercept later MFP21000637 Date: Project Manager: Legend SOW Right of Way Construction Notes: 1. Using 2" conduit placed for Job #353148 pull 136' RG- 11 from available tap in vault. 2. Set vault during Job #353148 or dig and intercept and set vault. 3. Bore 39' to buildging with 2 concrete cuts (9x4) & (2x3). Pull Rg--11 4. Place 2" exterior molding, Core drill into ceiling space and pull 65' RG-11 to network closet. P2#Heavy# 477863 Project Name InControl Address 124 Williams Ae S, Renton Wa 98057 Contractor Logo Prepared By:Scott Barker Date ENGINEERED FOR: 2/10/2021 3 Rev. Right of Way Sheet Number: New Ped New Vault Existing U/G ExistingAerial New U/G New Aerial Interior Path V Pole Lock Box Footage Text Box Callout Arrow New Tap Phase Identifier Text 150' x 1 V V 3x2 Cut 9x4 Cut 4 1 1 1 1 2 2 3 3 MFP21000637 This location is too close to the street tree. The Vault shall be installed in the hardscape with traffic rated lid and non skid finish Prince telecom telecommunications installation Fahm Salee 206-743-2173 JOB # CSG477863 Williams Ave S 116 SIGN SPACING = X (FEET) (1) FREEWAYS & EXPRESSWAYS RURAL HIGHWAYS RURAL ROADS RURAL ROADS and URBAN ARTERIALS RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED 55/70 mph 60/65 mph 45/55 mph 35/40 mph 25/30 mph 25mph or less 1500ft +/- 800ft +/- 500ft +/- 350ft +/- 200ft +/-(2) 100ft +/-(2) (1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. CHANNELIZING DEVICE SPACING CHART (FEET) 50/70 35/45 20/30 mph *Half-Spacing*TAPER TANGENT 20 N/A 40 30 20 80 60 40N/A BUFFER DATALONGITUDINAL BUFFER SPACE = B SPEED (mph) LENGTH (ft)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS) STATIONARYOPERATION(ft) 30 MIN. 100 max. MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION 4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCELONGITUDINAL BUFFER SPACE = B ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED 10ft LANE 11ft LANE 12ft LANE L L L1/2L 1/2L 1/2L Lanewidth MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting SHOULDER TAPERS(assume 10ft shoulders) 1/3L Devices(FT)LengthMPH 2025303540455055606570 70105150205270450500550600650700 668810161415161719 355575105135225250275300325350 345569889910 75115165225295495550605660715770 679911181516181920 406085115150250285305330370385 3455698991011 80125180245320540600660720780840 6710912191618192122 406590125160270300330360390420 345561099101112 2025303540455055606570 2535507090150170185200220235 33344666677 Shoulder tapers equalsshoulder Width x Speed/3 MINIMUM TAPER LENGTH = L (feet) POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70 105115125 150 165180 205225245 270 295320 450 495540 500 550600 550 605660 660720 -----780 840 LANEWIDTH(feet) 1011 12 drivewaycones -SPOTTER -ARROWBOARD - 115' Taper 110SIDEWALKCLOSEDR9-9SIDEWALKCLOSEDR9-9SIDEW ALK CLOSEDAHEADCROSS HERE R9-11 SIDEWALK CLOSEDAHEADCROSS HERER9-11 NO PARKING7 AM -6 PMFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T38drivewaydrivewaysidewalk planter strip w/rock parking Lane sidewalk parking Lane -Sidewalk shall be closed -Spotter/Flagger will be onsite to stop any Pedestrians get pass the work area NOTES : -No Parking signs shall be placed 24hrs in advance of work ROADWORKAHEADW20-1W4-2W20-5100' ABC 100'100'LEFT LANECLOSEDAHEADvault KENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOP KENNY STERTZTRAFFIC CONTROL SUPERVISOR Washington Oregon ID# WA016416 743390((ONE WAY ONE WAY sidewalksidewalk<39'><136'> NORTH NOT TO SCALE 124 vault 9'x4'Open cut 2'x3'<<65'>www.invarion.com MFP21000637