HomeMy WebLinkAboutMFP21000637.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP21000637
IVR Number: 21000637
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:02/11/2021Application Date:7231501970Parcel Number: 124 WILLIAMS AVE S
Permit Type:03/02/2021Issue Date:Franchise
Permit Work Class:03/02/2022Expiration Date:Minor Utility
Job Number: 477863Franchise Type:Cable
Description: Comcast to proof and pull RG 11 through existing conduit, dig and intercept and set vault, bore 39'. Pothole all
existing utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Fahm Saelee
Prince Telecom
Applicant
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP21000637
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
Scott Warlick 3/2/2021
MFP21000637
Scott Warlick CED 3/2/2021
Date:ROW Aerial
Project Manager:ROW Underground 65
Transport Aerial
Legend
SOW P2#Heavy# 477863
Route Overview
Construction Notes:
1. Using 2" conduit placed for Job #353148 pull 136' RG-11
from available tap in vault.
2. Set vault during Job #353148 or dig and intercept and set
vault.
3. Bore 39' to buildging with 2 concrete cuts (9x4) & (2x3).
Pull Rg--11
4. Place 2" exterior molding, Core drill into ceiling space and
pull 65' RG-11 to network closet.
Project Name InControl 124 Williams Ae S, Renton Wa 98057Address
Private Aerial
Private UndergroundContractor Logo
Prepared By:Scott Barker
2/10/2021
Sheet Number:
2
FootagesRev.Date
ENGINEERED FOR:
Route Overview
Transport Underground
175
New Ped
New Vault
Existing U/G
ExistingAerial
New U/G
New Aerial
V
Pole
Lock Box
Footage
Text Box
Callout Arrow
New Tap
Text
150'
x
1
V
39'65'
V136'Job in process
#353148
Kristen Gulbrand Financial Adviser
1
2
3 4
Job in process
#353148
Set vault to avoid dig and intercept
later
MFP21000637
Date:
Project Manager:
Legend
SOW
Right of Way
Construction Notes:
1. Using 2" conduit placed for Job #353148 pull 136' RG-
11 from available tap in vault.
2. Set vault during Job #353148 or dig and intercept and
set vault.
3. Bore 39' to buildging with 2 concrete cuts (9x4) &
(2x3). Pull Rg--11
4. Place 2" exterior molding, Core drill into ceiling space
and pull 65' RG-11 to network closet.
P2#Heavy# 477863 Project Name InControl Address 124 Williams Ae S, Renton Wa 98057
Contractor Logo
Prepared By:Scott Barker Date
ENGINEERED FOR:
2/10/2021
3
Rev.
Right of Way
Sheet Number:
New Ped
New Vault
Existing U/G
ExistingAerial
New U/G
New Aerial
Interior Path
V
Pole
Lock Box
Footage
Text Box
Callout Arrow
New Tap
Phase Identifier
Text
150'
x
1
V
V
3x2 Cut
9x4 Cut
4
1 1
1
1
2
2
3
3
MFP21000637
This location is too close to the
street tree. The Vault shall be
installed in the hardscape with
traffic rated lid and non skid finish
Prince telecom
telecommunications
installation
Fahm Salee
206-743-2173
JOB # CSG477863
Williams Ave S
116
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
BUFFER DATALONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCELONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L Devices(FT)LengthMPH
2025303540455055606570
70105150205270450500550600650700
668810161415161719
355575105135225250275300325350
345569889910
75115165225295495550605660715770
679911181516181920
406085115150250285305330370385
3455698991011
80125180245320540600660720780840
6710912191618192122
406590125160270300330360390420
345561099101112
2025303540455055606570
2535507090150170185200220235
33344666677
Shoulder tapers equalsshoulder Width x Speed/3
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70
105115125
150
165180
205225245
270
295320
450
495540
500
550600
550
605660 660720
-----780 840
LANEWIDTH(feet)
1011
12
drivewaycones -SPOTTER -ARROWBOARD -
115' Taper
110SIDEWALKCLOSEDR9-9SIDEWALKCLOSEDR9-9SIDEW
ALK CLOSEDAHEADCROSS HERE
R9-11 SIDEWALK CLOSEDAHEADCROSS HERER9-11
NO PARKING7 AM -6 PMFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
R7-T38drivewaydrivewaysidewalk
planter strip w/rock
parking Lane
sidewalk parking Lane
-Sidewalk shall be closed
-Spotter/Flagger will be onsite to stop any
Pedestrians get pass the work area
NOTES :
-No Parking signs shall be placed 24hrs
in advance of work
ROADWORKAHEADW20-1W4-2W20-5100'
ABC
100'100'LEFT LANECLOSEDAHEADvault
KENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION
PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOP
KENNY STERTZTRAFFIC CONTROL SUPERVISOR
Washington Oregon ID# WA016416 743390((ONE
WAY
ONE
WAY
sidewalksidewalk<39'><136'>
NORTH
NOT TO SCALE
124
vault
9'x4'Open cut 2'x3'<<65'>www.invarion.com
MFP21000637