HomeMy WebLinkAboutRS_OLD TIR_Walmart OGP 2_210218_v1.pdf6162 S. Willow Drive, Suite 320
Greenwood Village, CO 80111
303.770.8884 •GallowayUS.com
January 11th, 2021
Mr. Justin Johnson
Community & Economic Development
Civil Construction
1055 South Grady Way
Renton, WA 98057
RE: Drainage Conformance Letter for Technical Information Report – Retail Expansion –
Walmart Store #2516-240
Dear Mr. Johnson,
The purpose of this letter is to demonstrate that the drainage characteristics of the Pickup expansion
improvements for the Walmart Supercenter, Store #2516 in Renton, WA is in conformance with the
Technical Information Report – Retail Expansion dated February 25th, 2010 (per stamp date) by
Pac Land.
SUMMARY
The subject property is located at 743 Rainier Ave S, Renton, WA 98057, a previously developed lot
(part of the previous Walmart expansion) that consists of an existing Walmart with associated paved
parking, totaling an area of 13.65 Acres. It is bound to the north by SW 7th Street, east by Rainier Ave
S, and south & west by adjacent businesses.
The project area consists of approximately 0.30 Acres. The existing area is comprised of paved
parking lot, sidewalk, and landscape islands. Improvements to the site include the addition of a Pickup
building expansion (4,547 SF), conversion of landscape islands to pavement (824 SF), installation of a
Pickup canopy, re-striping of existing parking lot, relocation of existing waterline and hydrant,
relocation of storm sewer, the addition of 2 manholes, and relocation of an existing light pole.
DRAINAGE BASIN PATTERNS
Improvements to the site will not change the existing drainage basin areas and drainage shall follow
the existing drainage patterns for basins 2a and 2b outlined in the Technical Information Report –
Retail Expansion report (Note: these areas are indicated as proposed conditions within the existing
report). Portions of the landscape areas in proposed drainage basins 2a and 2b are being modified as
part of this project and will become impervious pavement. Total additional areas for basins 2a and 2b
are 824 SF between the basis. In addition to the changes illustrated above, 4,547 SF of existing
impervious area (sidewalk and pavement) will be removed and replaced by the proposed building
expansion. Roof drains from the proposed building expansion will tie into the existing catch basin to
the north. The existing roof drain in this area will be removed and a larger 10” PVC drain will be
installed.
Existing basin and proposed basin areas are shown in the tables on the following page.
Wal-Mart Stores Inc.
Walmart #2516 Pickup Expansion
01-11-2021
Galloway & Company, Inc.Page 2 of 4
Existing basin areas per Technical Information Report – Retail Expansion report.
(Note: These are listed as Proposed Sub-Basin areas in Table 2 of the above-mentioned report.)
Proposed basin areas based on new construction.
Surface Proposed Sub-Basins
1 2a 2b 3
Roof 150,244 4,209 338 0
Garden
Center
0 4,701 0 0
Landscaping 0 50,921 8,833 5,112
Pavement
(PGIS)
2,548 272,843 27,048 37,433
Sidewalk 0 24,776 3,620 1,927
Gravel 0 0 0 0
Total 152,792 357,450 39,839 44,472
SITE HYDROLOGY
Existing drainage patterns outlined in the Technical Information Report – Retail Expansion shall
remain unchanged with the current improvements.Existing basins 2a and 2b were broken down from
the existing report and runoff rates can be found below.
Proposed drainage patterns will follow the existing drainage patterns. Drainage basin 2a will maintain
the same area as noted previously, however, pervious areas (landscape island areas) will be
1 2a 2b 3
Roof 150,244 0 0 0
Garden
Center 0 4,701 0 0
Landscaping 0 51,795 8,783 5,112
Pavement
(PGIS)2,548 276,524 27,496 37,433
Sidewalk 0 24,430 3,560 1,927
Gravel 0 0 0 0
Total 152,792 357,450 39,839 44,472
Surface Existing Sub-Basins
Event Peak Q Rate (CFS)
2-year - 24 Hr 3.3151
10-year 5.1105
100-year 7.0812
Ex. Basin 2a Runoff Rates
SBUH Method
Event Peak Q Rate (CFS)
2-year - 24 Hr 0.3495
10-year 0.551
100-year 0.7726
Ex. Basin 2b Runoff Rates
SBUH Method
Wal-Mart Stores Inc.
Walmart #2516 Pickup Expansion
01-11-2021
Galloway & Company, Inc.Page 3 of 4
exchanged for impervious pavement areas and building roof area in exchange for pavement areas.
Drainage basin 2b will also maintain the same area, however, impervious areas will be exchanged for
pervious areas. The changes in the proposed drainage basins produced the following flow
information.
Detailed calculations can be found in Appendix B of this Report.
RETENTION/DETENTION ANALYSIS
As stated in the Retention/Detention System section of the Technical Information Report – Retail
Expansion, unless the 24-hour storm increases by more than 0.50 cfs from the pre-developed peak
runoff rate, the project is exempt from runoff control. Given that Basin 2a only increases by 0.0057 cfs
and Basin 2b only decreases by 0.0004 cfs, this project is exempt under the provision.
BIOSWALE TREATMENT
The existing biofiltration swale in the northwestern portion of the site will still maintain the treatment of
the Basin 2b area. As noted in the Technical Information Report – Retail Expansion report,
additional water quality was provided for the additional pavement area. This bioswale outlined in the
New PGIS section of the Technical Information Report – Retail Expansion report, shall facilitate in
providing the additional water quality. Per the existing report, the bioswale for Basin 2b was
overdesigned for the required conditions and given the minimal increase in flow rates, the existing
bioswale will suffice in providing the required water quality for the proposed development.
The existing bioswale design was verified using the following parameters:
The resultant swale design requires a minimum bottom width of 7.58 feet and a minimum treatment
length of 90.9 feet. Given that the swale was designed with an 8-foot bottom width and a 115 foot
treatment length, with a 1.0% longitudinal slope, the swale design fits into the parameters.
Calculations showing the existing bioswale characteristics accommodating the additional flows can be
found in Appendix C.
Event Peak Q Rate (CFS)
2-year - 24 Hr 3.3208
10-year 5.1157
100-year 7.0858
Prop. Basin 2a Runoff Rates
SBUH Method
Event Peak Q Rate (CFS)
2-year - 24 Hr 0.3491
10-year 0.5505
100-year 0.7721
Prop. Basin 2b Runoff Rates
SBUH Method
Criteria Value
2-yr, 24-hr flow 0.3491 cfs
Design Flow Depth 0.25 feet
Mannings Coeff 0.35
Residence Time 9 minutes
Side Slope 3.0 H:V
Bioswale Design Criteria - Single Event
Wal-Mart Stores Inc.
Walmart #2516 Pickup Expansion
01-11-2021
Galloway & Company, Inc.Page 4 of 4
CONCLUSIONS
Given the minor increase in flows (0.0057 cfs) for Basin 2a and the decrease in flows (0.0004 cfs) for
Basin 2b, as well as the fact that the bioswale can accommodate the additional flow rates as designed;
the improvements outlined in this conformance letter comply with the existing drainage report and
therefore no additional modifications are necessary.
Sincerely,
GALLOWAY
Brandon D. Alley, PE
Principal - Galloway US
BrandonAlley@gallowayUS.com
NOTE:
See attached documents for further drainage information:
Addendum A: Drainage Map
Addendum B: Drainage Detention Calculations
Addendum C: Bioswale Calculations
01/12/2021
APPENDIX A
PROPOSED DRAINAGE MAP
WWW W W
WW
SD
SD
1 inch = 100 ft.
( IN FEET )
GRAPHIC SCALE
0100 100 200 40050 RENTON, WAWAL-MART STORES, INC.BENTONVILLE, AR WAL-MART SUPERCENTER #2516-240SHEET
JOB No.
SCALE
DATE
CHECKED
DRAWN
REVISIONS BY
PB2002516.20
01/08/21
AS NOTED
JES
JSB
1
A
2 3
B NOT FOR CONSTRUCTIONGallowayUS.com6162 S. Willow Drive, Suite 320Greenwood Village, CO 80111303.770.8884DMAP
H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\3 Permit CDs\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\RHA2516_Drainage Map_REV1 - 2019-02-11 - Sid Biddle
DRAINAGE MAP
EXISTING SUB-BASIN DATA
APPENDIX B
DRAINAGE DETENTION CALCULATIONS
Appended on: Friday, January 8, 2021 11:31:19 AM
Existing 2a Event Summary
Record Id: Existing 2a
Licensed to: Unlicensed Copy
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 3.3151 8.00 1.0936 8.2058 SBUH
10 year 5.1105 8.00 1.6964 8.2058 SBUH
100 year 7.0812 8.00 2.3726 8.2058 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 8.2058 ac DCIA 0.00 ac
Pervious CN 96.26 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)7.0168 ac 98.00
Open spaces, lawns,parks (>75% grass)1.189 ac 86.00
Pervious Composited CN (AMC 2)96.2612
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces 30.00 ft 2.0%0.011 2.50 in 0.5232 min
Int Channel CMP Pipe (n=0.024 200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.7434 min
Page 1 of 1
1/8/2021file:///H:/RHA/WA,%20Renton%20-%20RHA002516.20%20-%20743%20Rainier%20Ave...
Appended on: Friday, January 8, 2021 11:49:17 AM
Existing 2b Event Summary
Record Id: Existing 2b
Licensed to: Unlicensed Copy
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 0.3495 8.00 0.1155 0.915 SBUH
10 year 0.551 8.00 0.182 0.915 SBUH
100 year 0.7726 8.00 0.257 0.915 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 0.91 ac DCIA 0.00 ac
Pervious CN 95.35 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)0.713 ac 98.00
Open spaces, lawns,parks (>75% grass)0.202 ac 86.00
Pervious Composited CN (AMC 2)95.3508
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces 30.00 ft 2.0%0.011 0.00 in 0.5232 min
Int Channel CMP Pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.7434 min
Page 1 of 1
1/8/2021file:///H:/RHA/WA,%20Renton%20-%20RHA002516.20%20-%20743%20Rainier%20Ave...
Appended on: Friday, January 8, 2021 11:50:29 AM
Proposed 2a Event Summary
Record Id: Proposed 2a
Licensed to: Unlicensed Copy
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 3.3208 8.00 1.0955 8.2058 SBUH
10 year 5.1157 8.00 1.6985 8.2058 SBUH
100 year 7.0858 8.00 2.3749 8.2058 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 8.2058 ac DCIA 0.00 ac
Pervious CN 96.29 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)7.0369 ac 98.00
Open spaces, lawns,parks (>75% grass)1.1689 ac 86.00
Pervious Composited CN (AMC 2)96.2906
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces 30.00 ft 2.0%0.011 2.50 in 0.5232 min
Int Channel CMP Pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.7434 min
Page 1 of 1
1/8/2021file:///H:/RHA/WA,%20Renton%20-%20RHA002516.20%20-%20743%20Rainier%20Ave...
Appended on: Friday, January 8, 2021 11:51:09 AM
Proposed 2b Event Summary
Record Id: Proposed 2b
Licensed to: Unlicensed Copy
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 0.3491 8.00 0.1153 0.9146 SBUH
10 year 0.5505 8.00 0.1818 0.9146 SBUH
100 year 0.7721 8.00 0.2568 0.9146 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 0.9146 ac DCIA 0.00 ac
Pervious CN 95.34 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)0.7118 ac 98.00
Open spaces, lawns,parks (>75% grass)0.2028 ac 86.00
Pervious Composited CN (AMC 2)95.3392
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces 30.00 ft 2.0%0.011 2.50 in 0.5232 min
Int Channel CMP Pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.7434 min
Page 1 of 1
1/8/2021file:///H:/RHA/WA,%20Renton%20-%20RHA002516.20%20-%20743%20Rainier%20Ave...
APPENDIX C
BIOSWALE CALCULATIONS
1/8/2021
JSB
RCJ
Step#
P-1 0.3491 cfs Water Quality Design Flow
P-2 0.01 ft/ft Swale Slope < 2%, underdrains required
P-3
D-1 0.25 ft
D-2 0.35
D-3 3 H:V
D-4a 7.58 ft
D-4b 9.08 ft
D-5 2.08 sf
90.6 = Length (Feet) Required
D-6 0.17 fps 90.9 = Length (Feet) w/ 9 min rest time
(this is still long enough)
D-7 Yes Okay - V<1.5 fps proceed to SC-1
D-8 D Table III-6.2 (D or E)
D-9 1.70 Table III - 6.6, n =nwq from step D-2
D-10 -ft
D-11 -
D-12 -%
D-13 -fps
D-14 -sf
D-15a -ft
D-15b -ft
D-16 If biofiltration swale is still to wide, see DOE page III-6-17 for more info and options
BIOSWALE DESIGN (SBUH)
Date
Designer
Project Manager
WMT Pickup Expansion #2516
PB2002516.20
On-Site (Redev)
Project Name
Project Number
Swale Title
Channel Width
T=b+2*y*z
b=(A/y)-Z*y
First Approx for VR
Hydraulic Radius
R=(V*R)/Vmax
Actual VR
VR=(1.486*(R1.6668)*S0.5)/n
% Difference
Actual V
V=(VR/R)
Channel X-Sec Area
A=Q/A
New Swale Bottom Width (b)
Degree of retardence
Design Steps (D)
Design Flow Depth (y)
Mannings Roughness Coeff (ᶯwq)
Side Slope (Z)
Swale bottom width (b)
b=(Q*n)/(1.486*y1.667*s0.5)-(Z*y)
Top width (T)
T=b+2*y*z
Area (A)
A=(b*y)+(Z*y2)
Flow Velocity
v=Q/A
Is Design Adequate
Qwq (2-yr, 24-Hr)
Slope of Swale (s)
Select Vegetation to be used Grass Legume Mix
Preliminary Steps (P)
Step#
SC-1 0.77 cfs
SC-2a Good (Good or Fair)
SC-2b 0.25 ft
SC-3 D Table III-6.2 (D or E)
SC-4 3.00 fps Table III-6.3
SC-5 0.043 (Good initial choice 0.04)
SC-6 2.70 Table III - 6.6
SC-7 0.9 ft
SC-8 2.90
SC-9 7.38%%
SC-10 3.22 fps
SC-11 0.24 sf
SC-12 Yes Swale is Stable
1.2 ft
8.00 ft
15.2 ft
SC-13 1.2 ft 115
SC-14 2.2 ft
SC-15 1.16 ft
SC-16a 32.12 sf
SC-16b 15.06 cfs Okay, Capacity > 100-yr, 24-Hr Storm
R=((b*y*t)+(Z*y*t2))/(b+2yt*(Z2+1)0.5)
Channel X-Sec Area
Channel Capacity
Q=(1.486*A*R0.677*s0.5)/n
Hydraulic Radius
A=Q/V
Compare A with Orig
New y =
New b =
b=(Q*n)/(1.486*y1.667*s0.5)-(Z*y)
New T =
T=b+2*y*z
Depth of Flow
y=(t-b)/2z
Total Swale Depth
yt = y+1
X-Sec Area
Degree of Retardance
Max allowed Velocity
Trial Mannings n
First Approx for VR
Hydraulic Radius
R=(V*R)/Vmax
Actual VR
VR=(1.486*R1.667*s0.5)/n
% difference
Actual V
V=VR/R
Qwq (100-yr - 24-Hr)
Condition of vegetation
Height of grass @ first storm
Stability Check Steps (SC)