HomeMy WebLinkAboutS-412401N
N
�
CL�
CL_
O
p
I
N I I E EXISTING RET. RR TIE WADE �
0
I �
HOUSE � EXISTING
N HOUSE
N I_
0
I SSCO
o RIM=421.72
o N
ABC
C I o Q0 PROPOSED 1 " WATER METER EX/STING 3/4" WA TER SERVICE AND
Ln 00 -- -_ TO BE INSTALLED BY CITY FORCES METER TO BE CUT AMD CAPPED AT
of SD---A-WAMY-METER P-E�1/T-IS_REQ_UIRED THE MAIN LINE BY CITY FORCES. A
SDMH _ ---------------------- ___---- WATER METER PERMIT IS REQUIRED
RIM=423.12 : SD -
INV=416.98 12"E) o � v 12" CONC. SD o CBSLL
INV=416.78�12"SE) cylo SSMH SD RIM-435.33 30' RIGHT OF WAY EASEMENT
w a RIM=423.89 / SD SD INV=432.38 8"N PER KCOUNTY RECORDING
IEX/STING POWER POLE SA 4TH S INV=432.23(12"E) NUMBER 6417479
o TO BE RELOCA TED INV= 431.91(12 "W)
I o �jLLIINE = 8" GI
U) 0!�� ED OF
� I
CB M'T. PROPOSED POWER PROPOSED 2f00 N s� s�' " w
RIM=423.22 7 7' - --�- - 3400
INV=417.84(18"S) POLE L CATION 0 DETENTION VAULT113
- - -
INV=417.79(18"W) I 0 68 "' V.
� 1f00
--------- 2f 2f1 PROPOSED VERTICAL CURB FOUND 2" BRASS DISC W/
51. ; I H PUNCH IN 4"X4" GONG.
CB 18" ADS r___________ , ROPOSED 1 WATER METER
° ° _ - I °°° BE INSTALLED BY CITY FORCES. MONUMENT & CASE
RIM=419.98 ° e g° L •'° ° o . a ° ° (MARCH 2005)
INV=416.08(18"E) 4 - ----- -- __ y . ° 4 . e A ►CATER METER PERM/T /S
INv-416.08(18"N) I I ° REQjy/RED
12" ADS 4 .3 ' LOT 1 ROOF/FOOTING LOT 2 SEWER ° °
`- DRAIN CONNECTION CONNECTION ° 43
s D M H I EX/ 77NG LIGH77NG POLE • • 1
RIM = 421.87 A D HANDHOLE TO BE I Q , A.. DRIVEWA Y -
RELOCATED ° 10 LANDSCAPE
INv-411.43(4"S) t PROPOSED w - - - -4 ° .a • m \ BUFFER
INV-41 1 .39(4"N) FOUND 2" BRASS DISC W/ ~ RIM- 21.66 Qi LOT 2 ROOF/F0077NG
PUNCH IN 4"X4" CONC. 5 SIDEWALK z I INV_415.58(12"NW) % DRAIN CONNECTION \
MONUMENT & CASE I V-415.10 12"W I
(SEP 2013) RELOCA D S7REET LIGHT AND ( ) LA IC ° EXl1NG ROCKE�?Y
HANOHOLE. S E C.O.R. S7D PLANS I REMOVE F NCE - - - TO BE\REMOVED
117.2, 119, >2 124, 135 AND ✓013 EXlS77NG GRA VEL � \
ss M H 10' PR/1/ATE EX/S77N� GRA VEL DR/IIf_WA Y
I SS RIM - 421.63 SEWER EASEMENT °
NV-41 6.6 W TO BE A;MOVED
I(CTR C NEL) ' � SHE ° I
S MH z
LOT 1 SEWER SERVICE.59 1 I U I I
Z
69 ISF A N N G 2
U BUILDING PAD I PI A 9, 271 fSF S H O
4270 BUILDING PAD w
Q L / 433.0 SH D ? 12'CH \ \
_j / EXISTING 7REES o 1
-� EX177NG HOUSE TO
Q I TO BE RETAINED ti LOT 1 ROOF/F0017NG / RE 0 EX/AIS77NG ROCKERY \ LOT Ij DRAIN CONNEC770N 4709 NE 24TH ST S ED z TO REMAIN b
/ r P OXIMATE DRAIN DECK I
IELD LOCATION q� \
j10 0' I �
-_ /
RO KERY
151.5 \
SD
I - - - - - - - LOT 2 ROOF/FOOTING
- - SD SD D S 2 - DRAIN CONNECTION
NE24TH ST I ® - ---- - - -� ��' , uu
15' RVA STORM EASEMENT „ W 168.4 158.47
I 73 LF INFIL TRA77ON TRENCH
FOUND 2" BRASS DISC W/ 0 I / 40 LF/NFILIRA77ON TRENCH
PUNCH IN 4"X4" GONG. I z 36 LF /NF/L TRA77ON TRENCH
MONUMENT & CASE 0 /
DOWN 0.5' (SEP 2013) I " CONNECT TO EX. CB EX/S77NG ROCKERY
TO BE REMOVED
C
" 41.5,
00
0
LOT 2
EXISTING HOUSE
PROJECT NO. 18265
� gIDEKO
OF INA.4,.
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
off•.• pF 41846 PLANNING
Sj DESIGN SURVEYING
ONAL E
/-_�5-Z_f5 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
SURVEYED: XXX SCALE. HORIZONTAL: NAD 1983/1991 CITY OF
DESIGNED: SHM
DRAWN: AR RENT 0 N
ONE INCH DATU M
CHECKED: SHY AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
NO. REVISION BY I DATE I AP P R APPROVED: SHM SCALE ACCORDINGLY
LOI
N
SCALE: 1" = 20'
0 10 20 40
"O!!�
STORM BMPS
REQUIRED STORM BMPS 877 ,r
PROWDED 1,400 ,r
R-412402,
RECORD DRAWING S-4124 011
W-4 7 240 7
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SITE HORIZONTAL CONTROL,
AND COMPOSITE UTILITY PLAN
✓ANUARY 2020
FIELDBOOK:
PAGE:
DRAWING NO:
Cl. 02