HomeMy WebLinkAboutEx08_C_Advisory_Notes_Green's_LandingDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 2 LUA21-000053 ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Jill Ding, 425-430-6598, jding@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and wh ere no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division’s approval of this work is required prior to final inspection and approval of the permit. 4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is being cleared. 5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way with in the area defined by the drip line of any tree to be retained. 6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. Development Engineering: (Contact: Brianne Bannwarth, 425-430-7299, bbannwarth@rentonwa.gov) 1. See comment memo dated March 30, 2021 Fire Authority: (Contact: Corey Thomas, 425-276-9582, cthomas@rentonrfa.org) 1. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is paid at building permit issuance. Credit will be granted for any existing homes that are removed or retained. 2. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet Exhibit 8 DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE ADVISORY NOTES TO APPLICANT Page 2 of 2 LUA20-000053 of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. Existing hydrants can be counted toward the requirements as long as they meet current code including 5 -inch storz fittings. It appears existing hydrants will meet minimum code requirements. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Fire sprinkler systems are required for all homes on dead end streets with only 16 -feet wide access streets, this applies to lots 2 and 3. Technical Services: (Contact: Amanda Askren, 425-430-7369, aaskren@rentonwa.gov) 1. None Community Services: (Contact: Leslie Betlach, 425-430-6619, lbetlach@rentonwa.gov) 1. None Police: (Contact: Cyndie Parks, 425-430-7521, cparks@rentonwa.gov) 1. None Building: (Contact: Rob Shuey, 425-430-7235, rshuey@rentonwa.gov) 1. None DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: March 30, 2021 TO: Jill Ding, Senior Planner FROM: Brianne Bannwarth, Development Engineering Manager Michael Sippo, Civil Engineer III SUBJECT: Utility and Transportation Comments for Green’s Landing 201 Hoquiam Ave NE LUA21-000053 We have reviewed the application for the Green’s Landing at 201 Hoquiam Ave NE (APN(‘s) 1523059219) and recommend approval based on the following conditions of approval and the following review comments: CONDITION OF APPROVAL: 1. Extension of 8-inch diameter sewer main is required on the entire NE 2nd Street frontage from the existing sewer manhole (facility ID MH4319) located at the intersection of Hoquiam Ave NE and NE 2nd Street, to provide future service to properties located upstream. Since this project is a resubmittal of a previously expired land use application (LUA 18-000024) and there has been a civil construction permit application submitted (C19000460) that has received one round of review by the City, the applicant is encouraged to review the City comments on the Civil Construction Permit Application and ensure that all comments are addressed within the Civil construction Permit Application. REVIEW COMMENTS EXISTING CONDITIONS The site is approximately 1.16 acres (50,534 square feet) in size. The site currently contains a single-family residence with an attached garage/shop. Free standing carport and three outbuildings. Water Water service is provided by King County Water District 90. The applicant has provided a Water Service Availability certificate from King County Water District 90. The Water Service availability certificate mentions that the developer will have to replace approximately 120 linear feet of 6- inch AC water main with 8-inch ductile iron water main on NE 2nd street frontage. DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE Green’s Landing LUA 21-000053 Page 2 of 5 Sewer Wastewater service is provided by the City of Renton. There is an existing 8-inch wastewater main located in Hoquiam Ave NE frontage (see City plan no. S-3651). There is no existing wastewater main on NE 2nd Street frontage. Storm There is an existing 12-inch diameter stormwater conveyance on the opposite side of Hoquiam Ave NE. Streets The site is a corner parcel and has frontages on two public streets Hoquiam Ave NE and NE 2nd Street. NE 2nd Street is a residential street with an available right of way (ROW) width of 60 feet. Hoquiam Ave NE is a residential street with an available ROW width of 30 feet. CODE REQUIREMENTS WATER 1. The developer shall provide the water improvements required by King County Water District #90. The information from the King County Water District #90 approved water plans should be provided at construction permit stage. Fire hydrants and fire flow should meet the requirements of Renton Regional Fire Authority. 2. A King County Water District #90 acceptance letter should be provided to City at time of final short plat. SEWER 1. Extension of 8-inch diameter sewer main is required on the entire NE 2nd Street frontage from the existing sewer manhole (facility ID MH4319) located at the intersection of Hoquiam Ave NE and NE 2nd Street, to provide future service to properties located upstream. The sewer manhole facility ID MH4319 that the required sewer extension must connect to is somewhat deep, approximately 12 feet. The sewer main extension will need to extend across NE 2nd Street frontage at a slope that will enable sewer to be provided to the maximum number of properties to the west. 2. All lots are to be served by individual side sewers with minimum 2% slope. Gravity sewer service is required. 3. The development is subject to applicable wastewater system development charges based on the size of the new domestic water to serve the project. a. SDC fee for sewer is based on the size of the new domestic water to serve the project. The current sewer fee for a 1-inch meter is $3,450.00 per meter. b. SDC fees are payable at construction permit issuance. 4. The Central Plateau Interceptor Special Assessment District fee (SAD) fee will be applicable on the project. The SAD fee is $538.48 per lot. The fee is due at construction permit issuance SURFACE WATER 1. A geotechnical report, dated August 7, 2015, completed by Robert M. Pride, LLC for the site has been provided. An infiltration testing report dated October 19, 2017, prepared by Riley Group was also provided. The submitted report describes the site as containing silty sand to a depth of approximately 3 feet below grade. The soils are underlain with recessional outwash/weathered lodgment till deposits. The infiltration testing report included log from one test pit in the site near DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE Green’s Landing LUA 21-000053 Page 3 of 5 NE 2nd Street. Infiltration tests and geotechnical report meeting all the requirements of the 2017 City of Renton Surface Water Design Manual (RSWDM) should be provided with the construction permit. The infiltration testing should be performed at a minimum at the location where infiltration on-site BMPs are proposed for the project. The location of the infiltration test currently included in the report is near NE 2nd Street and the full infiltration BMP is proposed in Tract A access tract, located further away from the infiltration test location. 2. A Preliminary Drainage Plan and Technical Information Report (TIR), dated March 20, 2019 and revised on October 22, 2020, was prepared by Litchfield Engineering with the Land Use Application. Based on the City of Renton’s flow control map, the site falls within the Flow Control Standards Forested site conditions and is within the Lower Cedar Drainage Basin. The development is subject to Directed Drainage Review in accordance with the 2017 Renton Surface Water Design Manual (RSWDM). The site is located in the Flow Control Standard Forested Site Conditions. All nine core requirements and the six special requirements have been discussed in the Technical Information Report. A private combined detention/wet vault is proposed to meet the detention and water quality requirements of the project. The location of the proposed stormwater vault is within the tract located inside the project as shown in the plans. The stormwater tract is proposed to gain access directly from NE 2nd Street by means of a driveway. The detention/water quality vault shall be designed in accordance with the RSWDM. All new conveyance systems constructed as part of the project must be sized to RSWDM standards for the total tributary area that the storm systems serve. A drainage plan and Technical Information Report (TIR) per RSWDM should be provided with the construction permit. Analysis should be included to show that the downstream facilities have the capacity to meet the drainage from the site and the upstream tributary area. 3. Appropriate on-site BMPs will be required to help mitigate the new runoff created by this development. A preliminary drainage plan, including the application of on-site BMPs, has been included with the land use application. The final drainage plan and TIR shall be prepared in accordance with RSWDM and must be submitted with the civil construction permit application. a. Final evaluation of the application of on-site BMPs to the maximum extent feasible will be completed during civil construction permit review. Additional infiltration tests are required to be done on the site where infiltration BMPS are proposed. If the infiltration tests do not provide information that the required minimum infiltration rate is available at the proposed full infiltration BMP location, the applicant may be required to apply additional on-site BMPs in order to meet the minimum requirements outlined in Core Requirement #9. This may impact the maximum ground impervious surface allowed on the lots, which may impact the building square footage. 4. Separate building permit is required for the stormwater vault. 5. A Construction Stormwater General Permit from Department of Ecology will be required for projects that have clearing and grading exceeding one acre. 6. Surface water system development fee is applicable to the project. The current rate of this fee is $2,000 per new single-family residence. This is payable prior to issuance of the construction permit. The rate that is current at the time of construction permit issuance will be applicable on the project. TRANSPORTATION DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE Green’s Landing LUA 21-000053 Page 4 of 5 1. The site has frontage on Hoquiam Ave NE and NE 2nd Street. 2. NE 2nd Street is a residential street with an available right of way (ROW) width of 60 feet. The required pavement width on NE 2nd Street is 32 feet, to match the existing width of the corridor west of the site. Per RMC 4-6-060, street frontage improvements including 0.5 feet wide curbs, 5 feet wide sidewalk, 8 feet wide landscaped planter back of sidewalk, drainage improvements, and streetlights are required on NE 2nd Street. However, the applicant has provided a modification request to allow the sidewalk to be placed directly back of the curb to allow the frontage to be consistent with the remainder of the corridor. Staff recommends approval of this modification request to provide consistent frontage within the corridor. Therefore, the required street and frontage improvements will include 32 feet wide pavement, 0.5 feet wide curb, 5 feet wide sidewalk, 8 feet wide planter back of the sidewalk, drainage improvements, and street light ing that meets the City’s standards. Per RMC 4-6-060, half street frontage improvements will be required to be built on NE 2nd Street frontage by the developer. Per RMC 4-6-060, residential streets are required to have a pavement thickness of 4 inches of HMA over 6 inches of crushed rock or match the existing thickness if greater than the thickness required by the code. a. The street cross section submitted with the land use application shows a total pavement width of 36 feet and should be revised accordingly. 3. Hoquiam Ave NE is a residential street with an available right of way (ROW) width of 30 feet. To provide consistency with the street and frontage along the corridor to the north of the site, the applicant has requested a street modification request to 16 feet half street paved width from the edge of the existing travel edge (that will provide a total 38 feet wide pav ed surface), 0.5 feet wide curb, 5 feet wide sidewalk, and 8 feet wide planter located back of the sidewalk. Staff recommends approval of this modification request to provide consistent frontage within the corridor. Therefore, the required street and frontage improvements will include a 38 feet wide pavement, 0.5 feet wide curb, 5 feet wide sidewalk, 8 feet wide planter back of the sidewalk, drainage improvements, and street lighting that meets city standards. Right of way dedication of approximately 30 feet is required, subject to survey. Per RMC 4-6-060, half street frontage improvements are required to be built on Hoquiam Ave NE frontage by the developer. Per RMC 4-6-060, residential streets are required to have a pavement thickness of 4 inches of HMA over 6 inches of crushed rock or match the existing thickness if greater than the thickness required by the code. 4. Residential street intersections shall have a minimum turning radius of 25 feet (RMC 4-6-060). 5. Lots 5 and 6 are proposed to gain access from Hoquiam Ave NE by means of individual driveways. Lots 1, 2, 3, and 4 are proposed to gain access from Hoquiam Ave NE by means of a private shared access in a tract of minimum 16 feet width. The paved travel width in the private access tract should meet the requirements of the Renton Regional Fire Authority. An access easement is required on the private access tract. Shared driveway should meet the requirements of RMC 4-6- 060.J and individual driveways should meet the requirements of RMC 4.4.080.I. The driveways should be located as far away as possible from the street intersection of NE 2nd Street and Hoquiam Ave NE. Maximum width of single-family driveways for two car garage is 16 feet. The stormwater tract is proposed to gain access from NE 2nd Street by means of a driveway. 6. Payment of the transportation impact fee is applicable on the single-family houses at the time of building permit issuance. The current transportation impact fee rate is $10,861.69 per single family house. The transportation impact fee that is current at the time of building permit will be applicable, payable at issuance of building permit. DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE Green’s Landing LUA 21-000053 Page 5 of 5 7. All utilities are required to be undergrounded including any within the property frontage. Undergrounding of utilities shall be as per the requirements of RMC 4-6-090. GENERAL COMMENTS 1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property frontage or within the site must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls. 3. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements. a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required except for water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 4. Please see the City of Renton Development Engineering website for the Construction Permit Application and Construction Permit Process and Submittal Requirements. Please contact the City to schedule a construction permit intake meeting. a. All civil plans shall conform to the current City of Renton survey and drafting standards. Current drafting standards can be found on the City of Renton website. b. A separate plan submittal will be required for a construction permit for utility work and street improvements. All plans shall be prepared by a licensed Civil Engineer in the State of Washington. c. All plan review for the City is now paperless. Please see http://rentonwa.gov/paperless/ for more information. 5. Fees quoted in this document reflect the fees applicable in the year 2021 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. 6. Technology fee will be applied to all permit fees. DocuSign Envelope ID: DDDFD573-0B6A-46D3-BFD5-B5DECCF164EE