SITE LIGHT P
(1) 1" PVC NC
(3) #8 CU. THWN
EXISTING CONDUIT I I
----------
EXISTING 60A BREAKER PANEL P1 EXISTING 1CONDUIT II
LOCATED IN CLOSET. REMOVE 30A TO BE USED FOR --aa
1 POLE BREAKERS AND INSTALL
NEW 2 POLE 30A LIGHTING BREAKER
PROVIDE ASTRONOMIC DAYLIGHT TIMER
FOR PARKING LOT LIGHT CONTROL.
COORDINATE PROGRAM TIMES WITH
CHURCH FACILITATOR.
Terra Vista N W
Consulting Engineers
J204 SMOKEY PO/NT OR, 1207
ARL/N070N, WA 9822,Y
J,60-691-9272
#W TERRAWSTANKfCOM
NEW CIRCUITS. CONDUIT
ROUTED OVER BUILDING
TO ELECTRICAL CLOSET
IN BASEMENT.
GENERAL NOTES:
1) ALL LIGHT FIXTURES TO BE CONTROLLER BY ASTRONOMIC TIMER FOR AUTOMATIC ON/OFF DAYLIGHT OPERATIONS.
2) LIGHT FIXTURES TO SHUT OFF DURING AFTER BUSINESS HOURS.
2) CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ALL EXISTING UNDERGROUND UTILITIES PRIOR
TO EXCAVATION AND TRENCHING.
3) ALL CONDUIT TRENCH DEPTH TO BE MINIMUM 24" TO TOP OF CONDUIT.
LUMINAIRE SCHEDULE
CALLOUT
SYMBOL
LAMP
DESCRIPTION
BALLAST
MOUNTING
MODEL
INPUT
VOLTS
NOTE >
NOTE 2
IES FILE
WATTS
S1
(48) LED
GALLEON AREA AND ROADWAY
ELECTRONIC
POLE
EATON — STREETWORKS
166
240V 2P 2W
20' HIGH POLE
NO DIMMING,
GAN—AF-03—LED—U-5MQ
p
LUMINAIRE(3) 70 CRI, 4000K, 1050mA
(FORMER COOPER LIGHTING),
CONTROLLED BY TIMER
i
LIGHTSQUARES WITH 16 LEDS EACH AND
GAN—AF-03—LED—U-5MQ
TYPE V MEDIUM OPTICS
S2
(48) LED
GALLEON AREA AND ROADWAY
ELECTRONIC
POLE
EATON — STREETWORKS
166
240V 2P 2W
20' HIGH POLE
NO DIMMING,
GAN—AF-03—LED—U-5MQ
(48) LED
LUMINAIRE(3) 70 CRI, 4000K, 1050mA
ELECTRONIC
(FORMER COOPER LIGHTING),
166
CONTROLLED BY TIMER
LIGHTSQUARES WITH 16 LEDS EACH AND
GAN—AF-03—LED—U-5MQ
TYPE V MEDIUM OPTICS
" WITH
3 8 CU. T E
----------------------------------------
08/06/2024
INTERCEPT EXISTING UG LIGHTING CONDUIT
AT THIS APPROXIMATE LOCATION AND EXTEND
TO NEW LIGHT FIXTURE. PROVIDED (3) #8 CU.
THWN WIRE IN EXISTING 1" PVC SCH 40 CONDUIT
BACK TO JUNCTION BOX MOUNTED ON BUILDING.
PO WER
1) 1" PVC CONDUIT WITH
3) #8 CU. THWN WIRE
REMOVE LIGHT FIXTURE AND
ELECTRICAL SYSTEMS AS NEEDED
FOR DEMOLITION OF SHED.
APPROXIMATE LOCATION.
PERMIT SUBMITTAL
03-13-19
SURVEYED:
PERMIT SUBMITTAL WITH CIVIL CHANGES
08-05-19
DESIGNED:
CITY COMMENTS
11-25-19
JBW
CITY COMMENTS
02-05-20
DRAWN:
CHECKED:
N0.
REVISION
I BY
I DATE
APP
AA
APPROVED:
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
VIRC TY OF
1431v
RENTON
Planning/Building/Public Works Dept.
R-408329
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
4ngelea Weihs 07/23/2019 '
FIRST UKRAINIAN PENTECOSTAL CHURCH
3811 NE 21 ST ST
RENTON, WA 98056
SITE LIGHTING AND
POWER PLAN
DATE:
2/5/20
FIELDBOOK:
PACE:
E2.0
SHEET: 32 OF: 65
0
CM
M
O
V J
Ali
J
C'7
Ln
N
O
O
cb
a
J
O
T
C)
C)
C)
I
T
CU
oC
CU
J
Q
O
U
LU
z
LU
-
z
Z_
Q
r�
V /
LL