20 MIL PE
IMPERMEABLE
LIN�o rii�o
TOF
(IF RE
TYPICAL SECTION VIEW
NOT TO SCALE
NOTE: IF SALTING AGENTS FOR SNOW AND ICE REMOVAL ARE USED ON OR NEAR THE
PROJECT, A GEOMEMBRANE BARRIER IS RECOMMENDED WITH THE SYSTEM. THE
GEOMEMBRANE LINER IS INTENDED TO HELP PROTECT THE SYSTEM FROM THE
POTENTIAL ADVERSE EFFECTS THAT MAY RESULT FROM A CHANGE IN THE
SURROUNDING ENVIRONMENT OVER A PERIOD OF TIME. PLEASE REFER TO THE
CORRUGATED METAL PIPE DETENTION DESIGN GUIDE FOR ADDITIONAL INFORMATION.
�u
CD
If
2 � .8"
COIL WIDTH
OPEN AREA = 3.76 SO IN/SQ FT
NOTES:
1. PERFORATIONS MEET AASHTO AND ASTM SPECIFICATIONS.
2. PERFORATION OPEN AREA PER SQUARE FOOT OF PIPE IS BASED
ON THE NOMINAL DIAMETER AND LENGTH OF PIPE.
3. DIMENSIONS SUBJECT TO MANUFACTURER'S TOLERANCES.
4. ALL HOLES 3/8"0.
EXFILTRATION AREA
STANDARD PERFORATION PATTERNS
APPROXIMATE AREA PER LINEAR FOOT OF PIPE
CORRUGATION PATTERN
PIPE
2 2/3" x 1/2"
3" x 1"
5" x 1"
ULTRA FLO
30"0
30.5 SQ.IN.
32.3 SQ.IN.
NOTES:
• GAGE AND COATING LIMITATIONS APPLY. 5" x 1" IS NOT AVAILABLE IN
ALUMINUM.
• DIMENSIONS SUBJECT TO MANUFACTURER'S TOLERANCES.
TYPICAL PERFORATION DETAIL
NOT TO SCALE
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech" ). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon wh
the drawing is based and actual field conditions are encounter
as site work progresses, these discrepancies must be report
to Contech immediately for re-evaluation of the design. Conk
accepts no liability for designs based on missing, incomplete
inaccurate information supplied by others.
BASE MAP/TOPOGRAPHY PROVIDED BY
OTHERS. ABOSSEIN ENGINEERING (AE)
CANNOT BE HELD LIABLE FOR
ACCURACY. CONTRACTOR SHALL FIELD
VERIFY GRADES, UTILITIES AND ALL
OTHER EX FEATURES & CONDITIONS. IF
CONDITIONS ARE NOT AS SHOWN &/OR
PLANS CANNOT BE CONSTRUCTED AS
SHOWN, CONTACT AE PRIOR TO
CONSTRUCTION.
\►G
1
O
w
0-
EL
i
r
IMPERMEABLE LINER\\ o o
0 5a
SUPPLIED BY OTHERS4
LU `ram
LU
a
SPAN (S)
L PIPE 0
PLAN
FRONT
48"0 to 90"0 FITTING REINFORCEMENT
MAY BE REQUIRED BASED ON HEIGHT OF
COVER AND LIVE LOAD CONDITION
TYPICAL MANWAY DETAIL
NOT TO SCALE
C—,\\ I //I—
i%W_NTECH"0
ENGINEERED SOLUTIONS LLC
www.ContechES.com
11815 NE Glenn Widing Drive, Portland, OR 97220
800-548-4667 503-240-3393 800-561-1271 FAX
PERMIT SUBMITTAL
REVISION
5
BEDDING ( 3
FOUNDATION ( 2
INITIAL FILL ENVELOPE( 1 )(1a
LIVE LOADS NOT TO EXCEED CONVENTIONAL HIGHWAY LOADS.
1 MINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER THE PIPE ARCH.
THE TRENCH WIDTH IS THE MINIMUM AMOUNT REQUIRED FOR PROPER INSTALLATION AND TO SUPPORT HORIZONTAL PRESSURE FROM THE
PIPE. THE MANUFACTURER'S SUGGESTED MINIMUM VALUE IS: 1.5S + 12".
1a MINIMUM EMBANKMENT WIDTH (IN FEET) FOR INITIAL FILL ENVELOPE:
3.OS BUT NO LESS THAN S + 4'0".
LIMITS OF DRAIN ROCK MAY BE
PLACED BELOW PIPE AS DEFINED BY
ENGINEER OF RECORD.
FOUNDATION SPEC STILL APPLIES
AND BEDDING WILL BE THE FIRST 4"
TO 6" BELOW INVERT
SPAN
MIN.
COVER
CORR.
PROFILE
17"-83"
12"
2 2/3" x 1/2"
<53"
12"
3" x 1" & 5" x 1"
54"-66"
15"
3" x 1 " & 5" x 1 "
67"-103"
18"
3" x 1" & 5" x 1"
104"-117"
21 "
3" x 1 " & 5" x 1 "
118" 142"
24"
3" x 1 " & 5" x 1 "
2 FOUNDATION SHALL BE WELL CONSOLIDATED. STABLE & CAPABLE OF SUPPORTING FILL MATERIAL LOAD.
3 OPEN -GRADED GRANULAR BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE BOTTOM OF
THE PIPE ARCH, 4" TO 6" IN DEPTH. SUGGESTED PARTICLE SIZE IS 1/2 CORRUGATION DEPTH. THE WIDTH OF BEDDING SHOULD BE THE EXTENTS
OF THE INVERT OF THE PIPE ARCH.
4 CORRUGATED STEEL PIPE ARCH (CSPA) [HEL-COR PIPE ARCH].
5 HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION. REFER TO AASHTO
26.5.2, 26.5.4 OR ASTM A798 10.3 TO PROPERLY ADDRESS CORNER BEARING PRESSURE.
5a THE BACKFILL MATERIAL SHALL BE A FREE -DRAINING, ANGULAR, WASHED -STONE PER AASHTO M 43 SIZE #3 WITH A'/�" 2" PARTICLE SIZE OR
APPROVED EQUAL. MATERIAL SHALL BE PLACED IN 12" MAXIMUM LIFTS AND SHALL BE WORKED INTO THE PIPE HAUNCHES BY MEANS OF
SHOVEL -SLICING, RODDING, AIR -TAMPER, VIBRATORY PLATE OR OTHER EFFECTIVE METHODS. COMPACTION IS CONSIDERED ADEQUATE WHEN
A DENSITY EQUIVALENT TO 90% STANDARD PROCTOR IS ACHIEVED OR WHEN NO FURTHER YIELDING OF THE MATERIAL IS OBSERVED UNDER
THE COMPACTOR OR UNDER FOOT. THE PROJECT ENGINEER OR HIS REPRESENTATIVE MUST BE SATISFIED WITH THE LEVEL OF COMPACTION.
INADEQUATE COMPACTION CAN LEAD TO EXCESSIVE PIPE DEFLECTIONS AND SETTLEMENT OF THE SOILS OVER THE SYSTEM. BACKFILL SHALL
BE PLACED SUCH THAT THERE IS NO MORE THAN A TWO -LIFT DIFFERENTIAL BETWEEN THE SIDES OF ANY PIPE IN THE SYSTEM AT ALL TIMES
DURING THE BACKFILL PROCESS. BACKFILL SHALL BE ADVANCED ALONG THE LENGTH OF THE SYSTEM AT THE SAME RATE TO AVOID
DIFFERENTIAL LOADING ON ANY PIPES IN THE SYSTEM.
6 INITIAL OPEN GRADED GRANULAR BACKFILL ABOVE PIPE ARCH MAY INCLUDE ROAD BASE MATERIAL (AND RIGID PAVEMENT IF APPLICABLE).
SEE TABLE ABOVE. INITIAL BACKFILL OF 7.0" PER ENGINEER OF RECORD.
6a TOTAL HEIGHT OF COMPACTED COVER IS MEASURED FROM TOP OF PIPE ARCH TO BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID
PAVEMENT.
7 FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS SHALL FOLLOW THE PROJECT PLANS AND SPECIFICATIONS PER THE
ENGINEER OF RECORD. PER ENGINEER OF RECORD, 4" CLEAN ROCK WITH 40% POROSITY.
NOTES:
• GEOTEXTILE SHALL BE USED AS REQUIRED TO PREVENT SOIL MIGRATION.
• FOR MULTIPLE BARREL INSTALLATIONS THE RECOMMENDED STANDARD SPACING BETWEEN
PARALLEL PIPE ARCH RUNS SHALL BE SPAN/2 BUT NO LESS THAN 12", OR 36" FOR PIPE SPANS
108" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING.
441 0 \` ■ r04LOM r-0
CMP DETENTION SYSTEMS
CONTECH
PROPOSAL
DRAWING
BY I DATE
TYPICAL BACKFILL DETAIL
NOT TO SCALE R-408333
PROJECT No.: SEC. No.: DATE:
35" x 24" PERFORATED UNDERGROUND RETENTION SYSTEM - 62472M10 624723 1 010 2/28/2020
DESIGNED: DRAWN:
FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH) KET JPC/DJB
RE N TO N , WA CHECKED: APPROVED
SITE DESIGNATION: FUPC SUBBASIN #1 SHEET NO.:
46 OF 65
/ O
1
�U00001) Call before you dig
SURVEYED: GEODETIC SURVEYING
SERVICE
DESIGNED:
DRAWN:
CHECKED:
P R APPROVED:
SCALE:
AS INDICATED
ON DRAWING
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
CITY OF
RENTON
Planning/Building/Public Works Dept.
R-408333
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING %
Nathan Janders 03/19/2020 '
FIRST UKRAINIAN PENTECOSTAL CHURCH
3811 NE 21 ST ST
RENTON, WA 98056
SITE DESIGNATION: FUPC SUBBASIN #1
DATE:
02-25-20
FIELDBOOK:
PAGE:
DRAWING NO:
sHEEr: 46 OF* 65
H
H
T
Q
J
2
U
OC
D
U
J
Q
U)
O
U
LU
Z
LU
0—
Z
Q
Z_
Q
Irn
—
V )
H