Loading...
HomeMy WebLinkAboutR-40834100 10 O w 12' %4" (#6) REBAR CAN BE CUT FLUSH — a ALL STEEL PER ASTM A36 TO OUTSIDE OF RAIL (BAR LENGTH = 16%4") OR BAR CAN _ EXTEND BEYOND RAIL %2"± FABRICATION TOLERANCE: �" _ � o FLAT BAR AND REBAR: MILL TOLERANCE APPLIES TYP. 3/$„ 12" TYP. CENTER TO CENTER 7/$" HOLE w/ 3/4" REBAR RUNG, RUNG SPACING ® WELD REBAR TO RUNG ON OUTSIDE OF STEEL RAIL — o 2%2" x Y8" FLAT BAR SIDE RAIL PLAN SIDE NOTES: 1. LADDERS CAN BE MADE IN 20'-0" STANDARD LENGTHS AND CUT TO FIT 2. ALL MATERIAL TO MEET ASTM A36 3. LADDER TO BE HOT DIPPED GALVANIZED PER ASTM A-123 AFTER FABRICATION IS COMPLETE STANDARD LADDER DETAIL NOT TO SCALE PART NO. HALAGVL16 PROVIDE MINIMUM OF 4 ATTACHMENT ANGLES (2 ON EITHER SIDE OF LADDER RAIL) TO CONNECT LADDER TO RISER EXTENSION RISER w/ LADDER AND STEPS IF EXTENSION IS REQUIRED RISER w/ LADDER AND STEPS L5" x 3" x %4" x 16" LONG AT V-0" SPACING. LONG LEG TO MAINLINE CMP PROJECT OUT. WELD TOP Fffl AND BOTTOM OF 3" LEG TO EACH 2% x %2, 5 x 1, 3 x 1, ETC. AX CORRUGATION CREST (THESE ANGLES SHOULD BE USED LU d FOR LARGER DIAMETER a MAINLINES WHERE ADDITIONAL STEPS ARE NEEDED) -3" 'NOTE: WHEN RISER EXTENSIONS ARE USED, THE PLANT SHOULD CUT 3" FROM THE SIDE RAILS AS SHOWN C SER JOINT -'• •- • ,.i •I� LADDER RAILS AND RUNGS (2)%4" FILLET WELDS 1" LONG ATTACHMENT ANC MINIMUM OF 4 ANGLES P LADDER SECTION, (2 EACH SIDE LADDER) 6' MAX. SPACI VERTICAL SECTION A -A JOINT RISER NORMALLY CMP WITH 2%3" x%" CORRUGATIONS (4) %6" FILLET WELDS FROM EACH ANGLE TO CORRUGATION CREST (2 WELD EACH SIDE) L3"x3"x%6" 5%2" LONG (4)%6" FILLET WELDS FROM EACH ANGLE CORRUGA- CREST (2 WELDS EACH S (4)L3"x3"x%6" 5%2" LONG (2)%4" FILLET WELDS 1" LONG FROM EACH ANGLE TO LADDER RAIL (4)%6" FILLET WELDS FROM EACH ANGLE TO CORRUGATION CREST (2 WELDS EACH SIDE) L3" x 3" x %6" 5%2" LONG LADDER RAILS PLAN RISER \� LADDER RAILS NOTE: AND RUNGS THIS DRAWING IS INTENDED TO APPLY TO LADDERS INSTALLED IN RISERS HAVING A DIAMETER OF 30" OR ELEVATION LARGER. DUE TO SPACE CONSTRAINTS AND LIMITED ACCESSIBILITY, THE PRACTICALITY AND SUITABILITY OF UTILIZING RISERS SMALLER THAN 30" DIAMETER RISER LADDER DETAIL AND/OR INCORPORATING LADDERS IN THESE SMALLER NOT TO SCALE DIAMETER RISERS SHOULD BE ADDRESSED BY THE OWNER AND PROJECT ENGINEER R-408341 The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor is Contech Engineered Solutions LLC ("Contech"). Neither this drawing,n part thereof, t ay be used, reproducedor ® �\I/� C741FNTECH �`I/ems / 0^�® !'% ' ��W lI1 �� x 24 PERFORATED UNDERGROUND RETENTION SYSTEM - 624723-020 PROJECT No.: 624723 SEC. No.: 020 DATE: 3/2/2020 DESIGNED. KET DRAWN: JPC/DJB in any consent y p Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for ENGINEERED SOLUTIONS LLC � ,► — `� = = CMP DETENTION SYSTEMS FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH) such use. If discrepancies between the supplied information upon which www.ContechES.com CONTECH RENTON, WA CHECKED: APPROVED: the drawing is based and actual conditions are encountered JMD JMD disc to site work progresses, ediatelyforr-these re-evaluationfth must be reported to Contech immediately for re-evaluation of the design. Contech 11815 NE Glenn Widing Drive, Portland, OR 97220 PROPOSAL SITE DESIGNATION: FUPC BASIN #2 SHEET NO.: accepts no liability for designs based on missing, incomplete or 800-548-4667 503-240-3393 800-561-1271 FAX DRAWING 54 OP 65::] AR DATE REVISION DESCRIPTION BY inaccurate information su plied b others. BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. ABOSSEIN ENGINEERING (AE) CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT AE PRIOR TO CONSTRUCTION. NO. PERMIT SUBMITTAL REVISION BY I DATE / O 1 0� � Call before you dig SURVEYED: GEODETIC SURVEYING SCALE: SERVICE VERTICAL 111 1988 AS INDICATED HORIZONTAL• NAD 1983/1991 DESIGNED: ON DRAWING DRAWN: ONE INCH DATUM CHECKED: AT FULL SCALE IF NOT ONE INCH ) P APPROvi SCALE ACCORDINGLY CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) CITY OF RENTON • Planning/Building/Public Works Dept. W IN COMPLIANCE WITH CITY OF RENTON STANDARDS FV ELOPMENT ENGINEERINGan Janders 03/19/2020 FIRST UKRAINIAN PENTECOSTAL CHURCH 3811 NE 21 ST ST RENTON, WA 98056 SITE DESIGNATION: FUPC BASIN #1 DATE 02-25-20 FIELDBOOK: PAGE: 54 65 H H T Q J O O O O I T 2 U OC D U J Q U) O U LU Z LU 0— Z Q Z_ Q I— V ) H