HomeMy WebLinkAboutR-40834600 I O ri w I- i YJ h ["I N 12 *NOTE: WHEN RISER EXTENSIONS ALL STEEL PER ARE USED, THE PLANT SHOULD %4" (#6) REBAR CAN BE CUT FLUSH — ° ASTM A36 CUT 3" FROM THE SIDE RAILS AS (4) %6" FILLET WELDS FROM LADDER RAILS TO OUTSIDE OF RAIL EACH ANGLE CORRUGATION AND RUNGS (BAR LENGTH = 16%4") OR BAR CAN SHOWN CREST (2 WELDS EACH SIDE) EXTEND BEYOND RAIL%"± FABRICATION TOLERANCE: ±%a" ° FLAT BAR AND REBAR: MILL 3/8„ TOLERANCE APPLIES (4) L3" x 3" x 3/6" RISER TYP. 5%2" LONG 01 _ 6" FROM R 12" TYP. R JOINT CENTER TO CENTER 7/$" HOLE w/ 3Y4' REBAR RUNG, *3" FROM O TOM R O RUNG SPACING ® WELD REBAR TO RUNG ON RISER JOINT OUTSIDE OF STEEL RAIL (2)%4" FILLET WELDS 1" LONG FROM EACH ANGLE 2%2" x 3/8" FLAT BAR SIDE RAIL TO LADDER RAIL PLAN SIDE PLAN NOTES: 1. LADDERS CAN BE MADE IN 20'-0" STANDARD LENGTHS AND CUT TO FIT *3" FRO TOP 2. ALL MATERIAL TO MEET ASTM A36 RISER JOINT O 3. LADDER TO BE HOT DIPPED GALVANIZED PER ASTM A-123 AFTER 6" FROM R FABRICATION IS COMPLETE R JOINT STANDARD LADDER DETAIL NOT TO SCALE PART NO. HALAGVL16 — — PROVIDE MINIMUM OF 4 ATTACHMENT — — — ANGLES (2 ON EITHER SIDE OF LADDER RAIL) _ ' — — _ A TO CONNECT LADDER TO RISER EXTENSION RISER w/ LADDER AND STEPS IF EXTENSION IS REQUIRED _ LADDER RAILS AND RUNGS RISER NORMALLY CMP WITH 23/3" x%2" CORRUGATIONS (4) %6" FILLET WELDS RISER w/ LADDER (4) %6" FILLET WELDS FROM EACH ANGLE TO FROM EACH ANGLE TO FROM CREST _I AND STEPS CORRUGATION CREST (2 WELDS EACH SIDE) (2 WELD EACH SIDE) (2)%4" FILLET WELDS 1" LONG111`4 _ _ — ATTACHMENT ANGLE O L3" x 3" x %6" L3" x 3" X 316"— tj L5" x 3" x %4" x 16" LONG AT V-0" MINIMUM OF 4 ANGLES PER 5%2" LONG 5%2" LONG SPACING. LONG LEG TO LADDER SECTION, (2 EACH SIDE OF MAINLINE CMP PROJECT OUT. WELD TOP LADDER) 6' MAX. SPACING 1'_ AND BOTTOM OF 3" LEG TO EACH VERTICALLY- 22/ x %2, 5 x 1, 3 x 1, ETC. AX CORRUGATION CREST _ (THESE ANGLES SHOULD BE USED— o FOR LARGER DIAMETER E MAINLINES WHERE ADDITIONAL SECTION A -A STEPS ARE NEEDED) LADDER RAILS NOTE: AND RUNGS THIS DRAWING IS INTENDED TO APPLY TO LADDERS INSTALLED IN RISERS HAVING A DIAMETER OF 30" OR ELEVATION LARGER. DUE TO SPACE CONSTRAINTS AND LIMITED ACCESSIBILITY, THE PRACTICALITY AND SUITABILITY OF UTILIZING RISERS SMALLER THAN 30" DIAMETER RISER LADDER DETAIL AND/OR INCORPORATING LADDERS IN THESE SMALLER NOT TO SCALE DIAMETER RISERS SHOULD BE ADDRESSED BY THE OWNER AND PROJECT ENGINEER R-408346 The design and information shown on this drawing is provided PROJECT No.: SEC. No.: DATE: as a service to the project owner, engineer and contractor by \I/ ® A ��I% UV00h J® �� �� 624723 030 3/3/2020 Contech Engineered Solutions ayb Contech"). Neither this CV41FNTECH - 35 x24 PERFORATED UNDERGROUND RETENTION SYSTEM-624723-030 drawing, nor any part thereof, may be used, reproduced or%��rmodiied in any manner without the prior written consent of 0,,, �` `� DESIGNED: DRAWN: Contech. comply ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH) KET JPC/DJB Contech expressly disclaims any liability or responsibility for such use. RENTON, WA CHECKED: APPROVED: If discrepancies between the supplied information upon which www.ContechES.com CONTECH JMD JMD the drawing is based and actual field conditions are encountered PROPOSAL assiteworkprogresses, these discrepancies must bereported 11815 NE Glenn Wilding Drive, Portland, OR 97220 SITE DESIGNATION: FUPC BASIN #3 to Contech immediately for re-evaluation of the design. Contact SHEET NO.: accepts no liability for designs based on missing, incomplete orLAR DATE REVISION DESCRIPTION BY 800-548-4667 503-240-3393 800-561-1271 FAX DRAWING 59 OF 65 inaccurate information su lied 11, others. BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. ABOSSEIN ENGINEERING (AE) CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT AE PRIOR TO CONSTRUCTION. U Call before you ff dig PERMIT SUBMITTAL SURVEYED: GEODETIC SURVEYING SCALE: SERVICE VERTICAL: NAVD 1988 AS INDICATED HORIZONTAL HAD 1983/1991 DESIGNED: ON DRAWING DRAWN: ONE INCH DATUM CHECKED: AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) CITY OF ,R RENTON • Planning/Building/Public Works Dept. A 'loe-yeralesj IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Nathan Janders 03/19/2020 ' FIRST UKRAINIAN PENTECOSTAL CHURCH 3811 NE 21 ST ST RENTON, WA 98056 SITE DESIGNATION: FUPC BASIN #3 DATE 02-25-20 FIELDBOOK: PAGE: 59 65 H H 00 T Q J 2 U OC D U J Q U) O U LU F- Z LU 0— Z Q Z_ Q I— V ) H