HomeMy WebLinkAboutR-40834800
I
O
Nt
Ii
w
I-
20 MIL PE
IMPERMEABLE
LIN riNi�o
TOF
(IF RE
TYPICAL SECTION VIEW
NOT TO SCALE
NOTE: IF SALTING AGENTS FOR SNOW AND ICE REMOVAL ARE USED ON OR NEAR THE
PROJECT, A GEOMEMBRANE BARRIER IS RECOMMENDED WITH THE SYSTEM. THE
GEOMEMBRANE LINER IS INTENDED TO HELP PROTECT THE SYSTEM FROM THE
POTENTIAL ADVERSE EFFECTS THAT MAY RESULT FROM A CHANGE IN THE
SURROUNDING ENVIRONMENT OVER A PERIOD OF TIME. PLEASE REFER TO THE
CORRUGATED METAL PIPE DETENTION DESIGN GUIDE FOR ADDITIONAL INFORMATION.
EDGE SPACING EQUAL ON BOTH SIDES
0 0 0 a 0/ 0 0 0
o _� o // -0 0 0
0 0 0 0 0 0
COIL WID
OP = 3.76 SQ IN/SQ FT
NOTES:
1. PERFORATIONS MEET AASHTO AND ASTM SPECIFICATIONS.
2. PERFORATION OPEN AREA PER SQUARE FOOT OF PIPE IS BASED
ON THE NOMINAL DIAMETER AND LENGTH OF PIPE-
3. DIMENSIONS SUBJECT TO MANUFACTURER'S TOLERANCES.
4. ALL HOLES 3/8" O.
EXFILTRATION AREA
STANDARD PERFORATION PATTERNS
APPROXIMATE AREA PER LINEAR FOOT OF PIPE
CORRUGATION PATTERN
PIPE
2 2/3" x 1/2"
3" x 1"
5" x 1"
ULTRA FLO
30"0
30.5 SQ.IN.
32.3 SQ.IN.
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon which
the drawing is based and actual field conditions are encountered
as site work progresses, these discrepancies must be reported
Cori Conimmediately for re-evaluation of the design. Contech
accepts no liability for designs based on missing, incomplete or
inaccurate information supplied by others.
NOTES:
• GAGE AND COATING LIMITATIONS APPLY. 5" x 1" IS NOT AVAILABLE IN
ALUMINUM.
• DIMENSIONS SUBJECT TO MANUFACTURER'S TOLERANCES.
TYPICAL PERFORATION DETAIL
NOT TO SCALE
DATE I REVISION DESCRIPTION I BY
BASE MAP/TOPOGRAPHY PROVIDED BY
OTHERS. ABOSSEIN ENGINEERING (AE)
CANNOT BE HELD LIABLE FOR
ACCURACY. CONTRACTOR SHALL FIELD
VERIFY GRADES, UTILITIES AND ALL
OTHER EX FEATURES & CONDITIONS. IF
CONDITIONS ARE NOT AS SHOWN &/OR
PLANS CANNOT BE CONSTRUCTED AS
SHOWN, CONTACT AE PRIOR TO
CONSTRUCTION.
\►G
L
PLAN
FRONT
48" O to 90" O FITTING REINFORCEMENT
MAY BE REQUIRED BASED ON HEIGHT OF
COVER AND LIVE LOAD CONDITION
TYPICAL MANWAY DETAIL
2
TR N EMBAON
�j FINAL BACKFILL
Z����� IN SITU
MINIMUM HEIGHT OF
COVER FOR PIPE
ARCHES IS SPAN/8 BUT
NOT LESS THAN 12" FOR
CORRUGATIONS:
• 2 2/3" x 1/2"
• 3"x1"
(SEE NOTE 6)
BACKFILL REQUIREMENTS FOLLOW THE GUIDELINES OF AASHTO LRFD BRIDGE DESIGN (SEC 12) AND CONSTRUCTION (SEC 26)
1 MINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER THE PIPE ARCH.
THE MINIMUM TRENCH WIDTH (12.6.6.1):
SPAN > 12": 1.5S + 12"
1a MINIMUM EMBANKMENT WIDTH (IN FEET) FOR INITIAL FILL ENVELOPE (12.6.6.2):
• SPAN < 24": 3.OS
• SPAN 24" - 112": S + 4'-0"
2 THE FOUNDATION UNDER THE PIPE ARCH AND SIDE BACKFILL SHALL BE ADEQUATE TO SUPPORT THE LOADS ACTING UPON IT (26.5.2).
3 ENGINEER TO DETERMINE IF BEDDING IS REQUIRED. BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY
SHAPED TO FIT THE BOTTOM OF THE PIPE ARCH, AND A MINIMUM OF TWICE THE CORRUGATION DEPTH IN THICKNESS, WITH THE
MAXIMUM PARTICLE SIZE OF ONE-HALF OF THE CORRUGATION DEPTH (26.3.8.1). WIDTH OF BEDDING TO BE EXTENTS OF THE INVERT OF
THE PIPE ARCH (26.5.3, FIG. 26.5.3-1).
4 CORRUGATED ALUMINUM PIPE ARCH (CAPA) [CORLIX PIPE ARCH].
5 HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION
(26.5.2 & 26.5.4).
5a INITIAL BACKFILL FOR PIPE EMBEDMENT TO MEET AASHTO A-1, A-2 OR A-3 CLASSIFICATION, OR APPROVED EQUAL, COMPACTED TO 90%
STANDARD PROCTOR (T 99). MAXIMUM PARTICLE SIZE NOT TO EXCEED 3" (12.4.1.2). ALL LIFTS SHALL BE PLACED IN A CONTROLLED
MANNER. IT IS RECOMMENDED THAT LIFTS NOT EXCEED AN 8" UNCOMPACTED LIFT HEIGHT TO PREVENT UNEVEN LOADING, AND THE
LESSER OF 1/3 THE SPAN OR 24" AS THE MAXIMUM DIFFERENTIAL SIDE -TO -SIDE (26.5.4).
6 INITIAL BACKFILL ABOVE PIPE ARCH MAY INCLUDE ROAD BASE MATERIAL (AND RIGID PAVEMENT IF APPLICABLE).SEE TABLE ABOVE.
INITIAL BACKFILL OF 7.50" PER ENGINEER OF RECORD
6a TOTAL HEIGHT OF COMPACTED COVER FOR CONVENTIONAL HIGHWAY LOADS IS MEASURED FROM TOP OF PIPE ARCH TO BOTTOM OF
FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT (12.6.6.3).
7 FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS SHALL FOLLOW THE PROJECT PLANS AND SPECIFICATIONS
PER THE ENGINEER OF RECORD (26.5.4.1). PER ENGINEER OF RECORD, 10.5" CLEAN ROCK WITH 40% POROSITY.
NOT TO SCALE NOTES:
•
ENGINEER TO DETERMINE IF GEOTEXTILE SHOULD BE CONSIDERED FOR USE TO PREVENT SOIL MIGRATION INTO VARYING SOIL TYPES (PROJECT ENGINEER).
•
FOR MULTIPLE BARREL INSTALLATIONS THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE ARCH RUNS SHALL BE SPAN/3 BUT NO LESS THAN
12", OR 36" FOR PIPE ARCH SPANS 108" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING (SEE TABLE C12.6.7-1).
TYPICAL BACKFILL DETAIL
NOT TO SCALE
R-408348
C721IONTECH ®
A� uTCA�J®
��,,,1`
11 1R
35 x24 PERFORATED UNDERGROUND RETENTION SYSTEM-624723.040
PROJECT No.:
624723
SEC. No.:
040
DATE
3/3/2020
DESIGNED:
DRAWN.
`IMLOW C =
ENGINEERED SOLUTIONS LLC
CMP DETENTION SYSTEMS
FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH)
KET
JPC/DJB
CHECKED:
JSD/JMD
APPROVED:
JSD/JMD
www.ContechES.com
CONTECH
RENTON, WA
11815 NE Glenn Widing Drive, Portland, OR 97220
PROPOSAL
SITE DESIGNATION: FUCP BASIN #4
SHEET NO.:
800-548-4667 503-240-3393 800-561-1271 FAX
DRAWING
61 of 65
PERMIT SUBMITTAL
REVISION
BY I DATE
/ O
1
�U00001) Call before you dig
SURVEYED: GEODETIC SURVEYING
SERVICE
DESIGNED:
DRAWN:
CHECKED:
P RI APPROVED:
SCALE:
AS INDICATED
ON DRAWING
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
CITY OF
RENTON
Planning/Building/Public Works Dept.
R-408348
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING %
Nathan Janders 03/19/2020 '
FIRST UKRAINIAN PENTECOSTAL CHURCH
3811 NE 21 ST ST
RENTON, WA 98056
SITE DESIGNATION: FUPC BASIN #4
DATE:
02-25-20
FIELDBOOK: