HomeMy WebLinkAboutR-40835000
I
O
w
ION LOADS
R
FINISHED
GRADE
CMP
PROTECTION
SLAB
36"0 MAX., HS-25 ACCESS CASTING
WITH GRADE RINGS AS REQUIRED, TO
BE PROVIDED AND INSTALLED BY
CONTRACTOR. MAYBE TOP MOUNTED
(AS SHOWN) OR RECESSED.
RIM/FINISHED
GRADE _ _ _ _- _�
d a I o a I
-
a
2
II I I if lrull�
�TIII � GASKET MATERIAL
SUFFICIENT TO PREVENT
CONSTRUCTION LOADS SLAB FROM BEARING ON l__
RISER TO BE PROVIDED BY
FOR TEMPORARY CONSTRUCTION VEHICLE LOADS, AN EXTRA AMOUNT OF COMPACTED COVER MAY BE REQUIRED OVER CONTRACTOR. ® 1�
THE TOP OF THE PIPE. THE HEIGHT -OF -COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. SECTION VIEW
THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED
GRADE COVER MINIMUMS FOR NORMAL HIGHWAY TRAFFIC.
AXLE LOADS
PIPE SPAN,
INCHES
(kips)
18-50 1 50-75 1 75-110 1 110-150
MINIMUM COVER (FT)
2.0
2.5
3.0
3.0
12-42
48-72
3.0
3.0
3.5
4.0
78-120
3.0
3.5
4.0
4.0
126-144
3.5
4.0
4.5
4.5
*MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL
COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO
THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE.
CONSTRUCTION LOADING DIAGRAM
NOT TO SCALE
SPECIFICATION FOR CORRUGATED STEEL PIPE -ALUMINIZED TYPE 2 STEEL
SCOPE HANDLING AND ASSEMBLY
THIS SPECIFICATION COVERS THE MANUFACTURE AND SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE
INSTALLATION OF THE CORRUGATED STEEL PIPE (CSP) DETAILED IN NATIONAL CORRUGATED STEEL PIPE ASSOCIATION (NCSPA)
THE PROJECT PLANS.
INSTALLATION
THE ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE
APPLICABLE REQUIREMENTS OF AASHTO M274 OR ASTM A929.
PIPE
THE CSP SHALL BE MANUFACTURED IN ACCORDANCE WITH THE
APPLICABLE REQUIREMENTS OF AASHTO M36 OR ASTM A760. THE
PIPE SIZES, GAGES AND CORRUGATIONS SHALL BE AS SHOWN ON
THE PROJECT PLANS.
ALL FABRICATION OF THE PRODUCT SHALL OCCUR WITHIN THE
UNITED STATES.
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Con expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon wh
the drawing is based and actual field conditions are encounter
as site work progresses, these discrepancies must be report
to Cont
ech immediately for re-evaluation of the design. Conte
accepts no liability for designs based on missing, incomplete
inaccurate information supplied by others.
SHALL BE IN ACCORDANCE WITH AASHTO STANDARD
SPECIFICATIONS FOR HIGHWAY BRIDGES, SECTION 26, DIVISION II
OR ASTM A798 AND IN CONFORMANCE WITH THE PROJECT PLANS
AND SPECIFICATIONS. IF THERE ARE ANY INCONSISTENCIES OR
CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE
WITH THE SITE ENGINEER.
IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO
FOLLOW OSHA GUIDELINES FOR SAFE PRACTICES.
MATERIAL SPECIFICATION
NOT TO SCALE
DATE I REVISION DESCRIPTION
BASE MAP/TOPOGRAPHY PROVIDED BY
OTHERS. ABOSSEIN ENGINEERING (AE)
CANNOT BE HELD LIABLE FOR
ACCURACY. CONTRACTOR SHALL FIELD
VERIFY GRADES, UTILITIES AND ALL
OTHER EX FEATURES & CONDITIONS. IF
CONDITIONS ARE NOT AS SHOWN &/OR
PLANS CANNOT BE CONSTRUCTED AS
SHOWN, CONTACT AE PRIOR TO
CONSTRUCTION.
NO.
1 CV4NTECH®
ENGINEERED SOLUTIONS LLC
11815 NE Glenn Wilding Drive, Portland, OR 97220
BY 800-548-4667 503-240-3393 800-561-1271 FAX
PERMIT SUBMITTAL
REVISION
LLI
REINFORCING TABLE
"BEARING
0 CMP
A
B 0
REINFORCING
PRESSURE
RISER
(PSF)
24
4'0
26
#5 @ 10" OCEW
2,540
4'x4'
#5 @ 10" OCEW
1,900
30"
4'-6"0
32
#5 @ 10" OCEW
2,260
4'-6" x 4'-6"
#5 @ 9" OCEW
1,670
36"
5'0
38
#5 @ 9" OCEW
2,060
5' x 5'
#5 @ 8" OCEW
1,500
42
5'-6"0
44
#5 @ 8" OCEW
1,490
5'-6" x 5-6"
#5 @ 8" OCEW
1,370
48
6'0
50
#5 @ 7" OCEW
1,210
6' x 6'
#5 @ 7" OCEW
1,270
** ASSUMED SOIL BEARING CAPACITY
ACCESS CASTING NOT SUPPLIED BY CONTECH
c'OO A
o B
#4 DIAGONAL TRIM
#4 DIAGONAL TRIM fi I BAR (TYP. 4 PLACES),
BAR (TYP. 4 PLACES), _ _ _ _ i� �� _ _ _ _I SEE NOTE 7.
SEE NOTE 7. - _--__kT__-�_ ___I -
j----1t�tL---1
1 i
Q
kl
-----IT-----47---t a-----TI - -----I
--� --- U-----
------ -- �I-----J
LI-----�
I IA/ M JI
I -1/1r I
INI I� 11
Ir iiI j I
{ I OPENING IN I Ill j l I
OPENING IN __ _ ILL_ �> <- __ I_____ PROTECTION
--1-� -�----J---1---- ---:::I-
_--_ -_�
PROTECTION ----fit- ------7{--�.�-It---- SLAB FOR - I
r----t-tl �-- --- --�--1
SLAB FOR I �I �� I�� I ACESS I I I ���I �� �� I��' I I I
ACCESS I I I� �� -'r I I I I I I�-�� 1 I I INTERRUPTED BAR
I I I I II i� I II
REPLACEMENT,
INTERRUPTED BAR �J LI11V_SEE NOTE 6.
REPLACEMENT, SEE , I �� I I I
NOTE 6. I I I I I I
I
STANDARD STANDARD
REINFORCING, REINFORCING,
SEE TABLE SEE TABLE
ROUND OPTION PLAN VIEW
wo 14 1 F z q_ i W,
CMP DETENTION SYSTEMS
CONTECH
PROPOSAL
DRAWING
BY I DATE
NOTES:
1. DESIGN IN ACCORDANCE WITH AASHTO, 17th
EDITION AND ACI 350.
2. DESIGN LOAD HS25.
3. EARTH COVER = V MAX.
4. CONCRETE STRENGTH = 4,000 psi
5. REINFORCING STEEL = ASTM A615, GRADE 60.
6. PROVIDE ADDITIONAL REINFORCING AROUND
OPENINGS EQUAL TO THE BARS INTERRUPTED,
HALF EACH SIDE. ADDITIONAL BARS TO BE IN THE
SAME PLANE.
l]
SQUARE OPTION PLAN VIEW
7. TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND BARS A
MINIMUM OF 12" BEYOND OPENING, BEND BARS AS REQUIRED
TO MAINTAIN BAR COVER.
8. PROTECTION SLAB AND ALL MATERIALS TO BE PROVIDED AND
INSTALLED BY CONTRACTOR.
9. DETAIL DESIGN BY DELTA ENGINEERS, ARCHITECTS AND LAND
SURVEYORS, ENDWELL, NY.
MANHOLE CAP DETAIL
NOT TO SCALE
35" x 24" PERFORATED UNDERGROUND RETENTION SYSTEM - U4723-040
FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH)
RENTON, WA
SITE DESIGNATION: FUCP BASIN #4
'o
Call before you dig
SURVEYED: GEODETIC SURVEYING
SERVICE
DESIGNED:
DRAWN:
CHECKED.
al` . �
SCALE
AS INDICATED
ON DRAWING
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERnCAL: NAVD 19ea
HORIZONTAL- HAD 1983/1991
DATUM
PROJECT No.:
SEC. No.:
DATE:
624723
040
3/3/2020
DESIGNED:
DRAWN:
KET
JPC/DJB
CHECKED:
APPROVED:
JSD/JMD
JSD/JMD
SHEET NO.:
63
OF 65
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
CITY OF
OR) RENTON
•
Planning/Building/Public Works Dept.
R-408350
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING Ar IL
Nathan Janders 03/19/2020 '
FIRST UKRAINIAN PENTECOSTAL CHURCH
3811 NE 21 ST ST
RENTON, WA 98056
SITE DESIGNATION: FUPC BASIN #4
DATE:
02-25-20
FIELDBOOK:
PAGE:
DRAWING NO:
SHEET: OF:
63 65