Loading...
HomeMy WebLinkAboutR-40835100 I O ri w I- ["I )� 12 *NOTE: WHEN RISER EXTENSIONS ALL STEEL PER ARE USED, THE PLANT SHOULD %4" (#6) REBAR CAN BE CUT FLUSH — ° ASTM A36 CUT 3" FROM THE SIDE RAILS AS (4) %6" FILLET WELDS FROM LADDER RAILS TO OUTSIDE OF RAIL EACH ANGLE CORRUGATION AND RUNGS (BAR LENGTH = 16%4") OR BAR CAN SHOWN CREST (2 WELDS EACH SIDE) EXTEND BEYOND RAIL%"± FABRICATION TOLERANCE: ±%a" ° FLAT BAR AND REBAR: MILL 3/8„ TOLERANCE APPLIES (4) L3" x 3" x 3/6" RISER TYP. 5%2" LONG 01 _ 6" FROM R 12" TYP. R JOINT CENTER TO CENTER 7/$" HOLE w/ 3Y4' REBAR RUNG, *3" FROM O TOM R O RUNG SPACING ® WELD REBAR TO RUNG ON RISER JOINT OUTSIDE OF STEEL RAIL (2)%4" FILLET WELDS 1" LONG FROM EACH ANGLE 2%2" x 3/8" FLAT BAR SIDE RAIL TO LADDER RAIL PLAN SIDE PLAN NOTES: 1. LADDERS CAN BE MADE IN 20'-0" STANDARD LENGTHS AND CUT TO FIT *3" FRO TOP 2. ALL MATERIAL TO MEET ASTM A36 RISER JOINT O 3. LADDER TO BE HOT DIPPED GALVANIZED PER ASTM A-123 AFTER 6" FROM R FABRICATION IS COMPLETE R JOINT STANDARD LADDER DETAIL NOT TO SCALE PART NO. HALAGVL16 — — PROVIDE MINIMUM OF 4 ATTACHMENT — — — ANGLES (2 ON EITHER SIDE OF LADDER RAIL) _ ' — — _ A TO CONNECT LADDER TO RISER EXTENSION RISER w/ LADDER AND STEPS IF EXTENSION IS REQUIRED _ LADDER RAILS AND RUNGS RISER NORMALLY CMP WITH 23/3" x%2" CORRUGATIONS (4) %6" FILLET WELDS RISER w/ LADDER (4) %6" FILLET WELDS FROM EACH ANGLE TO FROM EACH ANGLE TO CORRUGATION CREST _I AND STEPS CORRUGATION CREST (2 WELDS EACH SIDE) (2 WELD EACH SIDE) (2)%4" FILLET WELDS 1" LONG ATTACHMENT ANGLE O L3" x 3" x %6" L3" x 3" X 316" tj L5" x 3" x %4" x 16" LONG AT V-0" MINIMUM OF 4 ANGLES PER 5%2" LONG 5%2" LONG SPACING. LONG LEG TO LADDER SECTION, (2 EACH SIDE OF MAINLINE CMP PROJECT OUT. WELD TOP LADDER) 6' MAX. SPACING 1v- AND BOTTOM OF 3" LEG TO EACH VERTICALLY- 22/ x %2, 5 x 1, 3 x 1, ETC. AX CORRUGATION CREST _ (THESE ANGLES SHOULD BE USED— o FOR LARGER DIAMETER MAINLINES WHERE ADDITIONAL SECTION A -A STEPS ARE NEEDED) LADDER RAILS NOTE: AND RUNGS THIS DRAWING IS INTENDED TO APPLY TO LADDERS INSTALLED IN RISERS HAVING A DIAMETER OF 30" OR ELEVATION LARGER. DUE TO SPACE CONSTRAINTS AND LIMITED ACCESSIBILITY, THE PRACTICALITY AND SUITABILITY OF UTILIZING RISERS SMALLER THAN 30" DIAMETER RISER LADDER DETAIL AND/OR INCORPORATING LADDERS IN THESE SMALLER NOT TO SCALE DIAMETER RISERS SHOULD BE ADDRESSED BY THE OWNER AND PROJECT ENGINEER R-408351 The design and information shown on this drawing is provided PROJECT No.: SEC. No.: DATE: as a service to the project owner, engineer and contractor byis \I/ ® A ��I% �ITCA�J® �� �� 624723 040 3/3/2020 Contech Engineered Solutions LLC eContech" ). Neither this CV41FNTECH 35 x 24 PERFORATED UNDERGROUND RETENTION SYSTEM - 624723-040 drawing, nor any part thereof, maybe used, reproduced or%��modiied in any manner without the prior written consent of �,,, �` `� DESIGNED: DRAWN: Contech. comply ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH) KET JPC/DJB Contech expressly disclaims any liability or responsibility for such use. www.ContechES.com RENTON, WA CHECKED: APPROVED: If discrepancies between the supplied information upon which CONTECH JSD/JMD JSD/JMD the drawing is based and actual field conditions are encountered PROPOSAL assiteworkprogresses, these discrepancies must bereported 11815 NE Glenn Wilding Drive, Portland, OR 97220 SITE DESIGNATION: FUCP BASIN #4 to Contech immediately for re-evaluation of the design. Contact SHEET NO.: accepts no liability for designs based on missing, incomplete orLAR DATE REVISION DESCRIPTION BY 800-548-4667 503-240-3393 800-561-1271 FAX DRAWING 64 OF 65 inaccurate information supplied b others. BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. ABOSSEIN ENGINEERING (AE) CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT AE PRIOR TO CONSTRUCTION. ff U0� 0 o Call before you dig PERMIT SUBMITTAL SURVEYED: GEODETIC SURVEYING SCALE: SERVICE VERTICAL: NAVD 1988 AS INDICATED HORIZONTAL HAD 1983/1991 DESIGNED: ON DRAWING DRAWN: ONE INCH DATUM CHECKED: AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) CITY OF ,R RENTON • Planning/Building/Public Works Dept. 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Nathan Janders 03/19/2020 FIRST UKRAINIAN PENTECOSTAL CHURCH 3811 NE 21 ST ST RENTON, WA 98056 SITE DESIGNATION: FUPC BASIN #4 DATE 02-25-20 FIELDBOOK: PAGE: 64 65 H H 00 T Q J 2 U OC D U J Q U) O U LU F- Z LU 0— Z Q Z_ Q I— V ) H