HomeMy WebLinkAboutPRE21-000125 Meeting SummaryPREAPPLICATION MEETING FOR
Wu Short Plat
2005 Dayton Ave NE
PRE 21-000125
CITY OF RENTON
Department of Community & Economic Development
Planning Division
April 29, 2021
Contact Information:
Planner: Brittany Gillia, 425.430.7246, bgillia@rentonwa.gov
Public Works Plan Reviewer: Nathan Janders, 425-430-7382, njanders@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 425.430.7235, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
formal submittal.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
M E M O R A N D U M
DATE: April 14, 2021
TO: Brittany Gillia, Associate Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Dayton Short Plat
1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings
up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square
feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is
required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to
1,500 gpm. One existing hydrant appears to meet the minimum requirement; however, it does
require the installation of a 5-inch storz fitting.
2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit.
This fee is paid at building permit issuance. Credit is granted for the removal or retention of the
one existing home.
3. Fire department apparatus access roadways are required to be a minimum of 20-feet
wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways
shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required
within 150-feet of all points on the buildings. Proposed 16-feet wide access roadway does not
meet fire code. Applicant may apply for a variance to 16-feet wide with the condition that an
approved fire sprinkler system is installed in the home on Lot 2.
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: April 26, 2021
TO: Brittany Gillia, Planner
FROM: Nathan Janders, Civil Engineer II
SUBJECT: Wu Short Plat
2005 Dayton Ave NE
PRE21-000125
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
2253200115. The following comments are based on the pre-application submittal made to the City of
Renton by the applicant.
Water
1. The project is within the City of Renton’s water service area in the Highlands 435 Pressure Zone.
2. The static water pressure is approximately 59 psi at ground elevation of 298 feet.
3. There is an existing 8-inch water main located in Dayton Ave NE St that can deliver a maximum flow
capacity of 2,000 GPM (see water plan no. W-213801).
4. There is an existing ¾-inch water meter (LAT-004531) serving the existing residence at 2005
Dayton Ave NE.
5. Civil plans for the water main improvements will be required and must be prepared by a professional
engineer registered in the State of Washington. Please refer to City of Renton General Design and
Construction Standards for Water Main Extensions as shown in Appendix J of the City’s 2012 Water
System Plan. Adequate horizontal and vertical separations between the new water main and other
utilities (storm sewer pipes and vaults, sanitary sewer, power, gas, electrical) shall be provided for the
operation and maintenance of the water main. Retaining walls, rockeries or similar structures cannot
be installed over the water main unless the water main is installed inside a steel casing.
6. A separate water service (1-inch) and meter is required for each lot. The meter will be installed by City
forces and a water meter permit is required. The sizing of the meter and of the private service line to
the buildings shall be in accordance with the most recent edition of the Uniform Plumbing Code
Meters shall be placed in landscape strips, or behind the sidewalk, and within the right‐of‐
way. Meters shall not be installed within driveways
7. A minimum 1-inch meter is required if the new homes are served by sprinkler systems.
8. Based on the review of project information submitted for the pre-application meeting, Renton
Regional Fire Authority has determined that the preliminary fire flow demand for the proposed
development is 1,000 gpm for homes under 3,600 SF and goes up to a minimum of 1,500 gpm for
homes over 3,600 SF.
9. Installation of off-site and on-site fire hydrants, as required. The location and number of hydrants will
be determined by the Fire Authority based on the final fire flow demand and final site plan.
10. A conceptual utility plan will be required as part of the land use application for the subject
development.
11. The development is subject to applicable water system development charges (SDC’s) and meter
installation fees based on the number and size of the meters for domestic uses and for fire sprinkler
use. The development is also subject to fees for water connections, cut and caps, and purity tests.
Current fees can be found in the 2021 Development Fees Document on the City’s website. Fees will
be charged based on the rate at the time of construction permit issuance.
• The SDC fee for water is based on the size of the new domestic water to serve the project.
The current water fee is $4,450.00 per 1-inch service.
• Water service installation charges for each proposed domestic water service is applicable.
Water Service installation is $2,875.00 per 1-inch service line.
• Drop-in meter fee is $400 per ¾-inch meter and $460.00 per 1-inch meter.
• A credit will be applied to any service that is abandoned.
Sanitary Sewer
1. The project is within the City of Renton’s sanitary sewer service area.
2. There is an 8-inch gravity wastewater main in Dayton Ave NE (see record drawing S-035203).
3. The existing home on lot 1 is connected to the City sewer.
4. Individual sewer stubs from the sewer main and individual side sewers are required for each lot. All
new sewer stubs shall conform to the standards in RMC 4-6-040 and City of Renton Standard Details.
5. Private utility easements will be needed for any side sewer that passes through an adjacent lot prior
to connecting to the existing sewer main.
6. A conceptual utility plan will be required as part of the land use application for the subject
development.
7. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for
sewer is based on the size of the new domestic water to serve the project. Current fees can be
found in the 2021 Development Fees Document on the City’s website. Fees will be charged based on
the rate at the time of construction permit issuance.
• The current sewer fee for is $3,450.00 per 1-inch meter
• Final determination of applicable fees will be made after the water meter size has been
determined.
8. The development is within the West Kennydale Sewer Interceptor SAD boundary and is subject to
SAD fees. All lots, including the existing are subject to a $1,050 fee; the SAD has reached it’s
maximum value. Payment of these fees is required at time of construction permit issuance.
Surface Water
1. There is currently no stormwater features surrounding the property.
2. Drainage plans and a drainage report complying with the adopted 2017 Renton Surface Water Design
Manual will be required. Refer to Figure 1.1.2.A – Flow Chart of the 2017 Renton Surface Water Design
Manual (RSWDM) to determine what type of drainage review is required for this site. The site falls
within the City’s Forest Duration Flow Control Standard and the City’s . The site falls within the May
Creek drainage basin.
3. Critical areas on site that effect surface water include: regulated slopes.
4. The current Surface Water Standard Plans shall be used in all drainage plan submittals. The current
City of Renton Standard Details are available online in the City of Renton website
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton
5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will
be required to provide basic water quality treatment. Any proposed detention and/or water quality
vault shall be designed in accordance with the RSWDM that is current at the time of civil construction
permit application. Separate structural plans will be required to be submitted for review and approval
under a separate building permit for the detention and/or water quality vault.
6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new
runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated
in order of preference by feasibility as described in Section C.1.3 of the 2017 RSWDM. A preliminary
drainage plan, including the application of on-site BMPs, shall be included with the land use
application, as applicable to the project. The final drainage plan and drainage report must be
submitted with the utility construction permit application.
7. A geotechnical soils report for the site is required per the 2017 Renton Surface Water Design Manual
Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with
recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be
included in the report. The report should also include information concerning the soils, geology,
drainage patterns and vegetation present shall be presented in order to evaluate the drainage,
erosion control and slope stability for site development of the proposed plat. The applicant must
demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage,
or excess surface water runoff.
8. Erosion control measures to meet the City requirements shall be provided.
9. The development falls within the R-8 zone which has a maximum impervious surface area of 65% per
lot.
10. The development is subject to a surface water system development charge (SDC) fees. Fees will be
charged based on the rate at the time of construction permit issuance.
• The current SCD fee for new single family homes is $2,000 per home.
Transportation
1. Per City code 4-6-060 frontage improvements are required for new construction in excess of $150,000.
The proposed project fronts Dayton Ave NE to the east and private property on all other sides.
• Dayton Ave NE is classified as a residential access street, with an existing right-of-way (ROW)
width of 60 feet according to the King County Assessors map with an existing paved width of
approximately 25 feet. To meet the City’s complete street standards for Residential Access
streets, a minimum ROW width of 53 feet is required. Per RMC 4-6-060 half of street
improvements as taken from the ROW centerline shall be required and include a 26 foot
paved road (13 feet each side), a 0.5 foot curb, an 8 foot planting strip, and a 5 foot sidewalk.
No dedication will be required.
2. Shared driveways are allowed for access up to 4 lots provided at least one of the four lots abuts a publ ic
right-of-way with at least fifty linear feet of frontage and the subject lots are not created by a
subdivision of ten or more lots. Refer to the shared driveway requirements as outlined in RMC 4 -6-
060.J. Shared driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of sixteen feet; the Fire Authority may require the tract and paved surface to be up to
twenty feet wide. If a shared driveway abuts properties that are not part of the subdivision an eight
foot wide landscaped strip shall be provided between the shared driveway and neighboring
properties.
3. Refer to City code 4-4-080 regarding driveway regulations.
• A minimum separation of 5 feet is required between driveway and the property line.
• Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide
slotted drains.
• The maximum width of single loaded garage driveway shall not exceed nine feet (9') and
double-loaded garage driveway shall not exceed sixteen feet (16').
4. Undergrounding of all existing utilities is required on all frontages per RMC 4-6-090.
5. No Street lighting is required for a project that consists of less than 4 residential units.
6. Paving and trench restoration within the City of Renton right of way shall comply with the City’s Trench
Restoration and Street Overlay Requirements.
7. The development is subject to transportation impact fees. Fees will be charged based on the rate at
the time of construction permit issuance.
• The 2021 transportation impact fee is $10,861.69 per single family home.
• A credit will be applied if the existing home is demoed.
General Comments
1. If frontage improvements are required, all existing and proposed utility lines (i.e. electrical, phone, and
cable services, etc.) along property frontage or within the site must be underground as outlined in
RMC 4-6-090 – UTILITY LINES - UNDERGROUND INSTALLATION. The construction of these franchise
utilities must be inspected and approved by a City of Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the right-
of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in accordance with
code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
4. All construction utility permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer
shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up -
to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
5. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate sheets.
6. Fees quoted in this document reflect the fees applicable in the year 2019 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to the
permit type. Please visit www.rentonwa.gov for the current development fee schedule.
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: April 29, 2021
TO: Pre-Application File No. 21-000125
FROM: Brittany Gillia, Assistant Planner
SUBJECT: Wu Short Plat
2005 Dayton Ave NE
(Parcel No. 2253200115)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Ad ministrator, Public
Works Administrator, Planning Director, and City Council). Review comments may also need to be
revised based on site planning and other design changes required by City staff or made by the
applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal
Code. The Development Regulations are available online at
https://www.codepublishing.com/WA/Renton/.
Project Proposal: The applicant is proposing to subdivide an existing parcel into two (2) lots. The
subject property is located at 2005 Dayton Ave NE (APN 2253200115). The project site totals
12,180 square feet (0.27 acres) in area and is currently developed with a single-family home. The
applicant has provided two proposals and Staff has performed the analysis below based on
proposal 2. Proposal 1 contains a flag lot and flag lots are only considered when there is no other
feasible alternative to achieving minimum density, which does not appear to be the case in this
scenario. The applicant is proposing to remove the existing structure and construct new single
family homes on each of the new lots. The applicant proposes Lot 1 with an area of 4,757 square
feet and Lot 2 with 5,629 square feet. Access for Lot 2 is proposed off of a shared driveway
connecting to Dayton Ave NE and not enough information is provided regarding access for the
new home on Lot 1. Regulated Slopes and Wellhead Protection Area Zone 2 are mapped on the
project site.
Current Use: The project site is currently developed with a single-family home that is proposed
for removal.
Zoning/Density Requirements: The subject property is located within the Residential-8 (R-8)
zoning classification. The density range allowed in the R-8 zone is a minimum of 4.0 to a maximum
of 8.0 dwelling units per 1 net acre. The Residential Medium Density Land Use designation is
intended to implement the R-8 zone. Development in the R-8 zone is intended to create
opportunities for new single family residential neighborhoods and to facilitate high-quality infill
Wu Short Plat, PRE21-000125
Page 2 of 6
April 29, 2021
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
development that promotes reinvestment in existing single family neighborhoods. It is intended
to accommodate uses that are compatible with and support a high-quality residential
environment and add to a sense of community. Detached single family residential dwelling units
are permitted uses within the R-8 zoning designation.
Density: The area of public and private streets and critical areas would be deducted from the
gross site area to determine the “net” site area prior to calculating density. In order to calculate
the proposed density of the project, any area of public road, private driveway/easement, and/or
critical area dedication must be known. Public and private alleys are not deducted for the purpose
of net density calculation. All fractions which result from net density calculations shall be
truncated at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for
minimum or maximum density that result in a fraction that is 0.50 or greater shall be rounded up
to the nearest whole number. Those density calculations resulting in a fraction that is less than
0.50 shall be rounded down to the nearest whole number. Based on the gross land area of 12,180
square feet, the 2-lot proposal arrives at a gross density of approximately 7.2 du/ac (2 lots / 0.28
gross acres = 5.7 du/ac). Based on the gross density of 7.2 du/ac, the subject site would meet the
minimum density requirements of the zone. The applicant would be required to demonstrate
compliance with the net density requirements of the zone at the time of formal application.
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Single Family Zoning Designations” effective at the time of complete application
(noted as “R-8 standards” herein).
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-8 zone is 5,000
square feet for parcels being subdivided. Minimum lot width is 50 feet for interior lots and 60 feet
for corner lots; minimum lot depth is 80 feet. Please note that for short plats of parcels smaller
than one acre, one parcel may be allowed to be smaller than the required minimum lot size, if all
other parcels meet the required minimum lot size standard of the zone. In the R-8 zone, one parcel
may be allowed to be four thousand five hundred (4,500) square feet.
Lot depth shall be the horizontal distance between the front and rear lot lines, measured from
midpoint to midpoint; except in the case irregularly shaped lots. For irregularly shaped lots and
lots without an obvious rear lot line, the lot depth shall be measured to the midpoint of an
imaginary line at least fifteen feet (15') in length located entirely within the lot and farthest
removed and parallel to the front lot line or its tangent.
Based on the materials provided by the applicant in the second proposal, the proposed lots
would provide adequate area for compliance with the minimum area required, however,
proposed Lot 1 does not meet the minimum 60-foot width requirement for a corner lot. The
applicant will need to demonstrate compliance with the minimum lot size, width and depth
criteria of the zone, based on the definitions of lot size, width, and depth (RMC 4-11-120), at the
time of formal land use application.
Building Standards – The R-8 standards allow a maximum building coverage of 50% of the lot area.
The maximum impervious coverage in the R-8 zone is 65%. The maximum wall plate height is
restricted to 24 feet, and the buildings shall be not more than two stories. Roofs with a pitch equal
to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate
height; common rooftop features, such as chimneys, may project an additional four (4) vertical
feet from the roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.) shall not
extend above the maximum wall plate height unless the projection is stepped back one-and-a-
half (1.5) horizontal feet from each façade for each one (1) vertical foot above the maximum wall
Wu Short Plat, PRE21-000125
Page 3 of 6
April 29, 2021
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
plate height. The maximum wall plate height for detached accessory structures is 12 feet. The
gross floor area must be less than that of the primary structure. Accessory structures are also
included in building lot coverage calculations. The proposal’s compliance with the building
standards for the new home would be verified at the time of building permit review.
Setbacks – Setbacks are the minimum required distance between the building footprint and the
property line. The required setbacks for the R-8 zone are: Front yard: 20 feet for the primary
structure; Rear yard: 20 feet; Side yards: 5 feet; and Side yards along streets: 15 feet. Side yard
along a street is defined as the yard requirement that is neither a front yard nor a rear yard, yet
it abuts a street right-of-way or private street. New single family homes must comply with the
secondary front yard setback requirements from the both private street (Dayton Ave NE) and the
proposed shared driveway. Based on the provided site plan, the existing structure would
encroach into the proposed access tract, therefore a phased development would not be feasible.
Any retained structures must comply with the setback regulations of proposed lot lines.
Compliance with required setbacks for the new single family homes would be verified at the
time of building permit application.
Residential Design and Open Space Standards: The Residential Design and Open Space Standards
contained in RMC 4-2-115 would be applicable to any new residential structures.
Access: The applicant proposes to access proposed Lot 2 off of Dayton Ave NE and has not
provided information on proposed access to Lot 1. Shared driveways may be allowed for access
to four (4) or fewer residential lots, provided:
a. At least one of the four (4) lots abuts a public right-of-way and the street frontage of the
lot is equal to or greater than the lot width requirement of the zone;
b. The subject lots are not created by a subdivision of ten (10) or more lots;
c. A public street is not anticipated by the City of Renton to be necessary for existing or future
traffic and/or pedestrian circulation through the short subdivision or to serve adjacent
property;
d. The shared driveway would not adversely affect future circulation to neighboring
properties;
e. The shared driveway is no more than three hundred feet (300') in length; and
f. The shared driveway poses no safety risk and provides sufficient access for emergency
vehicles and personnel.
Shared driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of sixteen feet (16'); the Fire Department may require the tract and paved surface to
be up to twenty feet (20') wide. If a shared driveway abuts properties that are not part of the
subdivision, an eight foot (8') wide landscaped strip shall be provided between the shared
driveway and neighboring properties. The landscape strip shall be within a tract and planted with
a mixture of trees, shrubs, and groundcover. The shared driveway may be required to include a
turnaround per subsection H of RMC 4-6-060. The maximum grade for the shared driveway shall
not exceed fifteen percent (15%), except for within approved hillside subdivisions. The driveway
slopes cannot exceed 15%. If the grade exceeds 15%, a variance is required.
Alley access is the preferred street pattern for all new residential development except in the
Residential Low Density land use designation (RC, R-1, and R-4 zones) and the R-6 zone. All new
residential development in an area that has existing alleys shall utilize alley access. New
Wu Short Plat, PRE21-000125
Page 4 of 6
April 29, 2021
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
residential development in areas without existing alleys shall utilize alley access for interior lots.
If the developer or property owner demonstrates that alley access is not practical, the use of alleys
may not be required. The City will consider the following factors in determining whether the use
of alleys is not practical:
a. Size: The new development is a short plat.
b. Topography: The topography of the site proposed for development is not conducive
for an alley configuration.
c. Environmental Impacts: The use of alleys would have more of a negative impact on
the environment than a street pattern without alleys.
d. If site characteristics allow for the effective use of alleys.
Compliance with access standards would be verified at the time of formal land use application.
Driveways: The maximum width of single loaded garage driveways shall not exceed 9 feet and
double loaded garage driveways shall not exceed 16 feet. Compliance with driveway standards
would be verified at the time of building permit review. Compliance with driveway standards
would be verified at the time of formal land use review.
Parking: Each lot is required to accommodate off street parking for a minimum of two vehicles.
Compliance with driveway and parking standards would be verified at the time of building
permit review.
Landscaping: With the exception of critical areas, all pervious area shall have landscape
treatment. Landscaping may include hardscape such as decorative paving, rock outcroppings,
fountains, plant containers, etc. Ten feet (10') of on-site landscaping is required along all public
street frontages, with the exception of areas for required walkways and driveways and those
zones with building setbacks less than ten feet (10'). In those cases, ten feet (10') of landscaping
shall be required where buildings are not located. Street trees and, at a minimum, groundcover
shall be planted within the required landscape strips pursuant to the landscaping standards found
in RMC 4-4-070. A conceptual landscape plan shall be provided with the formal land use
application as prepared by a registered Landscape Architect, a certified nurseryman or other
certified professional.
Significant Tree Retention: An aerial image of the site identifies mature trees on the site. If
significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are
proposed to be removed, a tree inventory and a tree retention plan along with an arborist report,
tree retention plan and tree retention worksheet shall be provided with the formal land use
application as defined in RMC 4-8-120. The tree retention plan must show preservation of at least
30% of significant trees. The Administrator may authorize the planting of replacement trees on
the site if it can be demonstrated to the Administrator's satisfaction that an insufficient number
of trees can be retained. Please refer to Tree Retention and Land Clearing Regulations RMC 4-4-
130 for further general and specific tree retention and land clearing requirements.
In addition to retaining 30% of existing significant trees, each new lot would be required to provide
a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected trees that
do not contribute to a lot's required minimum tree density shall be held in perpetuity within a
tree protection tract.
Significant trees shall be retained in the following priority order:
Wu Short Plat, PRE21-000125
Page 5 of 6
April 29, 2021
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on
slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their
associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen
inches (18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; Other
significant native evergreen or deciduous trees; and Other significant non- native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods
are used as part of an approved enhancement project within a critical area or its buffer.
The Administrator may require independent review of any land use application that involves tree
removal and land clearing at the City's discretion.
If staff determines that the trees cannot be retained, replacement trees, with at least a 2-inch
caliper or an evergreen at least 6 feet tall, shall be planted at a rate of 12 caliper inches of new
trees to replace each protected tree removed. A formal tree retention plan prepared by an
arborist or landscape architect would be reviewed at the time of the Short Plat application.
Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project,
the location must be designated on the landscape plan or grading plan. A fence and/or wall detail
should also be included on the plan. A fence taller than 7 feet shall require a building permit or
an explicit exemption from the Building Official. A retaining wall that is 4 feet or taller, as
measured by the vertical distance from the bottom of the footing to the finish grade at the top of
the wall requires a building permit. A fence shall not be constructed on top of a retaining wall
unless the total combined height of the retaining wall and the fence does not exceed the allowed
height of a standalone fence. For more information about fences and retaining walls refer to RMC
4-4-040.
Critical Areas: Wellhead Protection Area Zone 2 and Regulated Slopes are mapped on the project
site. The overall purpose of the wellhead protection regulations is to protect aquifers used as
potable water supply sources by the City from contamination by hazardous materials. Some uses
are restricted that store, handle, treat, use, or produce substances that pose a hazard to
groundwater quality. If fill is used, then a fill source statement is needed. A geotechnical report
and erosion control plan shall be required at time of formal land use application. It is the
applicant’s responsibility to ascertain whether any additional critical areas or environmental
concerns are present on the site during site development or building construction.
Environmental Review: Short plats are categorically exempt from Environmental (SEPA) Review
except for lands covered by water or critical areas as designated in RMC 4-9-070H.2. The proposed
short plat would no longer be exempt from environmental review if further investigation of the
site results in the identification of designated critical areas.
Permit Requirements: The proposal would require administrative short plat approval. The
application would be reviewed within an estimated time frame of six to eight weeks. The 2021
administrative short plat application fee is $5,680.50 ($5,410.00 each plus a 5% Technology
Surcharge Fee). Each modification request is $262.50 ($250.00 each plus a 5% Technology
Surcharge Fee). All fees are subject to change. A Short Plat Submittal Requirements Checklist is
linked here. Additional information and forms needed for the land use application submittal can
be found on the City’s new website by clicking “Land Use Applications” on the Community &
Economic Development page, then “All Forms (A to Z).” The City now requires electronic plan
Wu Short Plat, PRE21-000125
Page 6 of 6
April 29, 2021
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2021\PRE21-000125
submittal for all applications. The City’s Electronic File Standards can be found on the City’s
website at https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=867190&dbid=0
Once Preliminary Short Plat approval is obtained, the applicant must complete the required
improvements, as well as satisfy any conditions of the preliminary approval before submitting for
Final Short Plat review. Once final approval is received, the plat may be recorded. The newly
created lots may only be sold after the plat has been recorded. In addition to the required land
use permits, separate construction and building permits would be required.
Public Notice: A minimum of one Public Information Sign is required for a Short Plat application.
The applicant is responsible for the procurement, installation and maintenance of the sign.
Detailed information regarding the land use application submittal requirements is provided on
the City of Renton website (www.rentonwa.gov).
Fees: In addition to the applicable building and construction fees, impact fees would be required.
Such fees would apply to all projects and are payable prior to building permit issuance. The 2021
impact fees are as follows:
• A Transportation Impact Fee based on $10,861.69 per each new detached dwelling unit.
• A Parks Impact Fee based on $2,914.99 per each new detached dwelling unit.
• A Fire Impact fee of $829.77 per each new detached dwelling unit.
• Renton School District Impact Fee is $7,681.00 per each new detached dwelling unit.
A handout listing Renton’s development-related fees is available on the City of Renton website
for your review.
Note: When the formal application materials are complete, the applicant is required to have
the materials prescreened prior to submitting the complete application package. Please contact
Brittany Gillia, Assistant Planner, at bgillia@rentonwa.gov for pre-screening.
Expiration: Upon approval, the Short Plat is valid for five years with a possible one year extension
(RMC 4-7-070M). It is the responsibility of the owner to monitor the expiration date.