Loading...
HomeMy WebLinkAboutMFP21001575.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP21001575 IVR Number: 21001575 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:03/31/2021Application Date:8857670110Parcel Number: 3915 TALBOT RD S Permit Type:05/05/2021Issue Date:Franchise Permit Work Class:05/05/2022Expiration Date:Minor Utility Job Number: 591303Franchise Type:Cable Description: Comcast proposes to push fiber 238'; risers up existing riser, overlash fiber 447' to splice case. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Stefania Spencer Sefnco Communications Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Comcast Cable Communications Management, LLC (253) 235-7406 Cody Shackett owen_shackett@comcast.com SEFNCO Communications (253) 999-2271 SEFNCC1850QD BL029666 JB0000591303 3915 Talbot Rd S Allied Dermatology LLC Comcast proposes push fiber ~238'; risers up existing riser, overlash fiber another ~447' to case SP.WAKV0145. XX 03/23/2021 MFP21001575 RESTORATION PER CITY OF RENTON STANDARDS Scott Warlick 5/5/2021 DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering x x x x x x x x x x x Allied Dermatology LLC 3915 Talbot Rd S Monday Friday 9:00 a.m.3:00 p.m. Comcast proposes push fiber ~238'; risers up existing riser, overlash fiber another ~447' to case SP.WAKV0145. SEFNCO Communications, Inc 253 999 2271 Ashley Kiehn askiehn@sefnco.com 4610 Tacoma Avenue Sumner, WA 98390 MFP21001575 Scott Warlick CED 5/5/2021 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 11/25/2019 APPLICANT AGREES TO ALL THE FOLLOWING: •TCP must be approved prior to commencing the work, and all permit conditions shall be met. •Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. •Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. •TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. •Approved Temporary TCP must be at the work site during work hours. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. •The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date 03/23/2021Ashley Kiehn/Area Manager EOPEOPFLFLFLFLFLFLFLWORKVEHICLEWORKVEHICLEEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPFLFLSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WEOPSWSWR/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→17620 TALBOT RD S #7,RENTON, WA 9805517600 TALBOT RD S #5TH,RENTON, WA 980553901 TALBOT RD S,RENTON, WA 980553915 TALBOT RD S #401,RENTON, WA 98055TALBOT RD STALBOT RD SS 177TH ST S 177TH ST POLE 1AAAAAAAAA180'58'235'WORKZONEWORKZONEWORKZONEALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTNREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-112ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7040/5540/5540/2525DISTANCEABCD1000' +/-1000' +/-1000' +/-1000' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-200' +/-100' +/-SPEEDLONGITUDINAL BUFFER SPACE = BLENGTHÄÄÄÄÄLANEWIDTHMINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)GENERAL NOTE:1.ALL ROW WORK MUST YIELD TO SCHOOLTRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPEDOR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS,DEPART: COMMENCE WORK.CONSTRUCTION TCP NOTES:1. /#+06#+0&4+8'9#;#%%'55#6#..6+/'52. 5+&'9#.-#4''+6*'412'01401612'0#5+&'9#.-+5%.15'&+(#/+0+/7/ž2#6*%#0016$'/#+06#+0'&/'#574'&(41/2412'46;.+0'14ž+(%4'#6'&(41/(#%'1(%74$(PEDESTRIAN PATH PROVIDED WHEREREQUIRED)#0&9+..$'MONITORED BY A SPOTTER TO INSUREFLOW AND SAFETY DURING WORK UNLESS OTHERWISENOTED.SPOTTER IS NOT TO TRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADACOMPLIANCE#..%10641.5'6Ä725+)052#%+0)#0&241%'&74'59+..%10(14/6152'%+(+%#6+10556#6'&+06*'('&'4#./#07#.1070+(14/'&64#((+%%10641.&'8+%'5 /76%& %+6+'5#0&8#4+175/70+%+2#.+6+'5/#;*#8'#.51#&126'&52'%+#.+<'&)7+&'.+0'5(1464#((+%%10641.9+6*+06*'+4,74+5&+%6+10+6+56*'4'52105+$+.+6;1(6*'10Ä5+6'64#((+%%10641.2'4510#.615''+(#0&#0;52'%+#.%10&+6+105':+56(.#))'455*#..$'75'&+0#%%14&#0%'9+6*9#%ÄÄ+(10.;10'.#0'+512'0+0#&+4'%6+106*#6.#0'5*#..$'#/+0+/7/1(ž9+&'70.'5552166'4(.#))'45#4'75'&+09*+%*%#5'6*'.#0'%#0$'#/+0+/7/1(žTABLE 6C-2CBRIGHTLANECLOSEDAHEAD ROADWORKAHEAD LIMIT SPEED R2-1 35AFAS SPOTTER SPOTTER ROADWORKAHEADA MFP21001575 EOPFLFLEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWEOPR/WR/WSWSWSWR/WEOPEOPR/WR/WR/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/WR/WEOP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DR I V EW A Y →←DRIVEWAY→ ←DRIVEWAY→501 S 38TH CT,RENTON, WA 98055507 S 38TH CT,RENTON, WA 980553721 TALBOT RD S,RENTON, WA 98055500 S 38TH CT,RENTON, WA 980553710 TALBOT RD S,RENTON, WA 980553704 TALBOT RD S,RENTON, WA 98055517 S 37TH ST,RENTON, WA 980553620 TALBOT RD S,RENTON, WA 980553623 TALBOT RD S,RENTON, WA 98055418 S 37TH ST,RENTON, WA 98055TALBOT RD STALBOT RD SS 174TH ST S 37TH ST S 38TH ST S 38TH STPOLE 2APOLE 3AAAAAAAAAAAAAAAA235'106'234'WORKZONEPOLE 4ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTNREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-222ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7040/5540/5540/2525DISTANCEABCD1000' +/-1000' +/-1000' +/-1000' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-200' +/-100' +/-SPEEDLONGITUDINAL BUFFER SPACE = BLENGTHÄÄÄÄÄLANEWIDTHMINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)GENERAL NOTE:1.ALL ROW WORK MUST YIELD TO SCHOOLTRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPEDOR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS,DEPART: COMMENCE WORK.CONSTRUCTION TCP NOTES:1. /#+06#+0&4+8'9#;#%%'55#6#..6+/'52. 5+&'9#.-#4''+6*'412'01401612'0#5+&'9#.-+5%.15'&+(#/+0+/7/ž2#6*%#0016$'/#+06#+0'&/'#574'&(41/2412'46;.+0'14ž+(%4'#6'&(41/(#%'1(%74$(PEDESTRIAN PATH PROVIDED WHEREREQUIRED)#0&9+..$'MONITORED BY A SPOTTER TO INSUREFLOW AND SAFETY DURING WORK UNLESS OTHERWISENOTED.SPOTTER IS NOT TO TRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADACOMPLIANCE#..%10641.5'6Ä725+)052#%+0)#0&241%'&74'59+..%10(14/6152'%+(+%#6+10556#6'&+06*'('&'4#./#07#.1070+(14/'&64#((+%%10641.&'8+%'5 /76%& %+6+'5#0&8#4+175/70+%+2#.+6+'5/#;*#8'#.51#&126'&52'%+#.+<'&)7+&'.+0'5(1464#((+%%10641.9+6*+06*'+4,74+5&+%6+10+6+56*'4'52105+$+.+6;1(6*'10Ä5+6'64#((+%%10641.2'4510#.615''+(#0&#0;52'%+#.%10&+6+105':+56(.#))'455*#..$'75'&+0#%%14&#0%'9+6*9#%ÄÄ+(10.;10'.#0'+512'0+0#&+4'%6+106*#6.#0'5*#..$'#/+0+/7/1(ž9+&'70.'5552166'4(.#))'45#4'75'&+09*+%*%#5'6*'.#0'%#0$'#/+0+/7/1(žTABLE 6C-2SHOULDER WORK BROAD WORKAHEAD LIMIT SPEED R2-1 35AROADWORKAHEADA ROADWORKAHEADA MFP21001575 SEFNCOCOMMUNICATIONSPROPOSED AERIAL AND UNDERGROUND FIBER INSTALLATIONCOMCASTALLIED DERMATOLOGY3915 TALBOT RD S, RENTON, WA 98055JB# 0000591303MFP21001575 A A A A A A A A A A A A A A A A A A A ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21VICINITY MAP3915 TALBOT RD S,RENTON, WA 98055COSTRUCTION SUPERVISORSEFNCOCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-6SITE-PLAN7-8TYPICAL DETAILS82N/AN/ADESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER575LFPROOF/PULL 48CT FIBER238LFTOTAL:813LFVICINITY MAPBEGIN 3623 TALBOT RD S,RENTON, WA 98055ENDAARON HINES4610 TACOMA AVESUMNER, WA 98104PHONE:253-299-4948EMAIL:AARHINES@SEFNCO.COMPERMITTINGASHLEY KIEHN253-999-22714610 TACOMA AVESUMNER, WA 98104ASKIEHN@SEFNCO.COMBRANDON MORRIS410 TACOMA AVESUMNER, WA 98104PHONE:253-306-1908EMAIL: BRANDONMORRIS@SEFNCO.COMMFP21001575 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21GENERAL NOTES8REVISIONSDATEDESCRIPTIONINITIAL3N/AN/ATHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.GENERAL NOTESRENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP21001575 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/218REVISIONSDATEDESCRIPTIONINITIAL4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREPROPOSED AERIAL OVERLASH AAPROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED PEDESTALPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS BORE PITN/AN/ALEGEND PROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFMHMHBUILDING OUTLINEFLFOG LINETRENCHPSPLICE CASEPROPOSED AERIAL STORAGEEXISTING AERIAL STORAGE0'0'POTHOLESWSIDEWALK LINEPROPOSED AERIAL STRAND AAMFP21001575 EOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WEOPSWSWSWR/WSW R/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→17710 TALBOT RD S,RENTON, WA 9805517620 TALBOT RD S #7,RENTON, WA 9805517600 TALBOT RD S #5TH,RENTON, WA 980553901 TALBOT RD S,RENTON, WA 980553915 TALBOT RD S #401,RENTON, WA 98055TALBOT RD STALBOT RD SS 177TH ST S 177TH ST60'7'43'10'51'12'32'7'60'14'36'10'POLE 1AAAAA180'58'235'ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTN8REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN - 1 EXISTING VAULTSCOPE OF WORKPROOF/PULL THRU EXISTINGCOUNDUIT WITH 48CT FIBEREXISTING POLE (1)1234CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.TIE IN TO EXISTING SPLICEOVERLASH 48CT FIBER TOEXISTING STRAND.52123345MATCH TO SITE PLAN - 2 MFP21001575 EOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWEOPEOPR/WR/WR/WSWSWSWSWSWR/WEOPEOPEOPR/WR/WR/WR/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/WR/WEOP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRI V EW A Y →←DRIVEWAY→ ←DRIVEWAY→501 S 38TH CT,RENTON, WA 98055507 S 38TH CT,RENTON, WA 980553721 TALBOT RD S,RENTON, WA 98055500 S 38TH CT,RENTON, WA 980553710 TALBOT RD S,RENTON, WA 980553704 TALBOT RD S,RENTON, WA 98055517 S 37TH ST,RENTON, WA 980553620 TALBOT R D S , RENTON, WA 9 8 0 5 5 3623 TALBOT RD S,RENTON, WA 98055418 S 37TH ST,RENTON, WA 98055TALBOT RD STALBOT RD SS 174TH ST S 37TH ST S 38TH ST S 38TH ST 60' 7' 41' 12'59'13'35'11'40'6'28'6'36'9'18'9'39'6'20'13'POLE 2AAAAAAPOLE 3AAAAAPOLE 4AAAAAAAAAAA235'106'234'ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTN8REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN - 2 EXISTING POLE (2-4)SCOPE OF WORKEND AT EXISTING SPLICE123CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.OVERLASH 48CT FIBER TOEXISTING STRANDMATCH TO SITE PLAN - 1 122231MFP21001575 AERIAL TYPICALS8REVISIONSDATEDESCRIPTIONINITIAL7TYPICAL DETAILS-1 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTNTSMFP21001575 13"18"17"14"3"12"19"22"TYPICAL VAULT DETAILALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERT8REVISIONSDATEDESCRIPTIONINITIAL8TYPICAL DETAILS-2 NTSMFP21001575 SEFNCO COMMUNICATIONS 4610 TACOMA AVE SUMNER WA, 98390 March 23, 2021 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB0000591303 To whom it may concern, SEFNCO Communications has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash fiber ~447’ to case SP.WAKV0145. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. If you have any further questions regarding this project please contact Aaron Hines: 253-307-0248. Thank you for your consideration in this matter. Ashley Kiehn Permit Area Manager SEFNCO Communications, Inc. o 253 999-2271 | e askiehn@sefnco.com Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan May 5, 2021 Owen Shackett Comcast Cable Communications Management 410 Valley Ave NW Puyallup, WA 98371 Via Email: owen_shackett@comcast.net SUBJECT: Request for Undergrounding Exemption (JB#591303, MFP21001575, 3915 Talbot Road S) Dear Mr. Shackett: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have SEFNCO Communications, Inc. overlash 48ct fiber approximately 575 lineal feet to existing Puget Sound Energy (PSE) poles along the west side of Talbot Road South within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#591303 Page 2 of 2 May 5, 2021 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, May 19, 2021. Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. Sincerely, Brianne Bannwarth, PE Development Engineering Manager cc: C.E. “Chip” Vincent, CED Administrator Vanessa Dolbee, Planning Director Justin Johnson, Assistant Development Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Permit Technician Franchise Permits Ashley Kiehn, SEFNCO Communications, Inc., askiehn@sefnco.com Enclosures: Site Plan SEFNCOCOMMUNICATIONSPROPOSED AERIAL AND UNDERGROUND FIBER INSTALLATIONCOMCASTALLIED DERMATOLOGY3915 TALBOT RD S, RENTON, WA 98055JB# 0000591303MFP21001575 A A A A A A A A A A A A A A A A A A A ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21VICINITY MAP3915 TALBOT RD S,RENTON, WA 98055COSTRUCTION SUPERVISORSEFNCOCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-6SITE-PLAN7-8TYPICAL DETAILS82N/AN/ADESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER575LFPROOF/PULL 48CT FIBER238LFTOTAL:813LFVICINITY MAPBEGIN 3623 TALBOT RD S,RENTON, WA 98055ENDAARON HINES4610 TACOMA AVESUMNER, WA 98104PHONE:253-299-4948EMAIL:AARHINES@SEFNCO.COMPERMITTINGASHLEY KIEHN253-999-22714610 TACOMA AVESUMNER, WA 98104ASKIEHN@SEFNCO.COMBRANDON MORRIS410 TACOMA AVESUMNER, WA 98104PHONE:253-306-1908EMAIL: BRANDONMORRIS@SEFNCO.COMMFP21001575 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21GENERAL NOTES8REVISIONSDATEDESCRIPTIONINITIAL3N/AN/ATHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.GENERAL NOTESRENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP21001575 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/218REVISIONSDATEDESCRIPTIONINITIAL4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREPROPOSED AERIAL OVERLASH AAPROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED PEDESTALPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS BORE PITN/AN/ALEGEND PROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFMHMHBUILDING OUTLINEFLFOG LINETRENCHPSPLICE CASEPROPOSED AERIAL STORAGEEXISTING AERIAL STORAGE0'0'POTHOLESWSIDEWALK LINEPROPOSED AERIAL STRAND AAMFP21001575 EOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WEOPSWSWSWR/WSW R/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→17710 TALBOT RD S,RENTON, WA 9805517620 TALBOT RD S #7,RENTON, WA 9805517600 TALBOT RD S #5TH,RENTON, WA 980553901 TALBOT RD S,RENTON, WA 980553915 TALBOT RD S #401,RENTON, WA 98055TALBOT RD STALBOT RD SS 177TH ST S 177TH ST60'7'43'10'51'12'32'7'60'14'36'10'POLE 1AAAAA180'58'235'ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTN8REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN - 1 EXISTING VAULTSCOPE OF WORKPROOF/PULL THRU EXISTINGCOUNDUIT WITH 48CT FIBEREXISTING POLE (1)1234CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.TIE IN TO EXISTING SPLICEOVERLASH 48CT FIBER TOEXISTING STRAND.52123345MATCH TO SITE PLAN - 2 MFP21001575 EOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWEOPEOPR/WR/WR/WSWSWSWSWSWR/WEOPEOPEOPR/WR/WR/WR/WEOPEOPR/WR/WR/WR/WEOPR/WR/WR/WR/WEOP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRI V EW A Y →←DRIVEWAY→ ←DRIVEWAY→501 S 38TH CT,RENTON, WA 98055507 S 38TH CT,RENTON, WA 980553721 TALBOT RD S,RENTON, WA 98055500 S 38TH CT,RENTON, WA 980553710 TALBOT RD S,RENTON, WA 980553704 TALBOT RD S,RENTON, WA 98055517 S 37TH ST,RENTON, WA 980553620 TALBOT R D S , RENTON, WA 9 8 0 5 5 3623 TALBOT RD S,RENTON, WA 98055418 S 37TH ST,RENTON, WA 98055TALBOT RD STALBOT RD SS 174TH ST S 37TH ST S 38TH ST S 38TH ST 60' 7' 41' 12'59'13'35'11'40'6'28'6'36'9'18'9'39'6'20'13'POLE 2AAAAAAPOLE 3AAAAAPOLE 4AAAAAAAAAAA235'106'234'ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTN8REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN - 2 EXISTING POLE (2-4)SCOPE OF WORKEND AT EXISTING SPLICE123CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.OVERLASH 48CT FIBER TOEXISTING STRANDMATCH TO SITE PLAN - 1 122231MFP21001575 AERIAL TYPICALS8REVISIONSDATEDESCRIPTIONINITIAL7TYPICAL DETAILS-1 ALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERTNTSMFP21001575 13"18"17"14"3"12"19"22"TYPICAL VAULT DETAILALLIED DERMATOLOGY 3915 TALBOT RD S RENTON, WA 98055 JB# 0000591303REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV03/24/21R DIGALERT8REVISIONSDATEDESCRIPTIONINITIAL8TYPICAL DETAILS-2 NTSMFP21001575 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP21001575 Engineering 1 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 2 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 3 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 4 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. Page 1 of 1