Loading...
HomeMy WebLinkAboutMFP21001633.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21001633 IVR Number: 21001633 Permit Information Permit Name: ExteNet Systems - Fiber - SOUTH RENTON - PHASE 2 - SEG 15 Address/Location:04/16/2021Application Date:2193100010Parcel Number: 300 SW 27TH ST Permit Type:05/10/2021Issue Date:Franchise Permit Work Class:05/10/2022Expiration Date:Major Utility Job Number: SOUTH RENTON - PHASE 2 - SEG 15Franchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 SOUTH RENTON PHASE 2 SEG 15 ROD & PROOF EXISTING CTL/LUMEN VAULTS AND CONDUIT ALONG W 27TH ST FROM JUST WEST OF E VALLEY RD ST TO NACHES AVE SW, ALONG NACHES AVE SW SOUTH OF W 27TH AVE, AND ALONG OAKSDALE AVE SW NORTH OF W 27TH ST. PLACE INNERDUCT & FIBER Contacts Name Address PhoneTypeBilling MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 2501 EAST VALLEY ROAD LLC 1717 MCKINNEY AVE #1900 DALLAS , TX 75202 Owner Rachel Fenton Extenet Systems LLC 3030 Warrenville Rd Lisle, IL 60532 Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 5/10/2021 MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 114Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE AND MULTI-LANE SHIFT (FOR URBAN STREET)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST AND WEST BOUND DIRECTIONS)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COM300 SW 27TH STPARCEL NO. 2193100010299 SW 27TH STPARCEL NO. 1253800110WORKVEHICLEW20-1W20-5RW4-2RXXXW20-1W20-5CW1-4RXXXW16-7RW16-7RL50' - 100'L/2L/2ROADWORKAHEADRIGHTLANECLOSEDAHEADCENTERLANECLOSEDAHEADHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESMFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 214Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE AND MULTI-LANE SHIFT (FOR URBAN STREET)TRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESWORKVEHICLELROADWORKAHEADRIGHTLANECLOSEDAHEADOKW20-1W20-5RW4-2RXXXR3-6RSW 27TH STLIND AVE SWPARCEL NO. 12538100902423 LIND AVE SWPARCEL NO. 30230590862700 LIND AVE SWPARCEL NO. 1253800120MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 314Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SINGLE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADWORKVEHICLELW20-1W20-5RW4-2RXXX2423 LIND AVE SWPARCEL NO. 3023059086800 SW 27TH STPARCEL NO. 2523049064PARCEL NO. 2523049004SW 27TH STSPRINGBROOK CREEK 50' - 100'MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 414Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SINGLE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #4 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADWORKVEHICLE L50' - 100'PARCEL NO. 2523049004800 SW 27TH STPARCEL NO. 25230490641100 SW 27TH STPARCEL NO. 2523049058SW 27TH STW20-1W20-5RW4-2RXXXMFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 514Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #5 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADWORKVEHICLEW20-1W20-5RW4-2RXXXW20-5RW20-1X W20-5RW20-1X PARCEL NO. 2523049004PARCEL NO. 2523049001PARCEL NO. 0886700400OAKESDALE AVE SW SW 27TH STL50' - 100'MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 614Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SINGLE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #6 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADWORKVEHICLEW20-1W20-5RW4-2RXXXOAKESDALE AVE SW SW 27TH STLOKR3-6RPARCEL NO. 0886700170PARCEL NO. 0886700400PARCEL NO. 2523049004PARCEL NO. 2523049001MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 714Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SINGLE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #7 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADSW 27TH STWORKVEHICLE L50' - 100'FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLSPOTTER FLAGGERS ON SITETO ESCORT PEDESTRIANSAROUND THE WORK AREAW20-1W20-5RW4-2RXXX2700 NACHES AVE SWPARCEL NO. 0886700330PARCEL NO. 0886700170MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 814Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - ONE-LANE, TWO-WAY CLOSURE WITH CONTROLLED INTERSECTION (FOR URBAN STREET)TRAFFIC CONTROL PLAN #8 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESROADWORKAHEADWORKVEHICLE4' MIN50' - 100'SIGNAL TO BE SET TO FOUR WAYRED FLASHING MODE. OFFICERREQUIRED TO MONITOR /CONTROL TRAFFIC WHENWORKING IN INTERSECTION.FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLW20-1W20-4W20-7XXXONE LANEROADAHEADBEPREPAREDTO STOPW20-1W20-4W20-7XXW20-7W3-4W20-1X X W20-7W3-4W20-1XXSW 27TH STNACHES AVE SW W16-7L2700 NACHES AVE SWPARCEL NO. 08867003302715 NACHES AVE SWPARCEL NO. 08867002701300 SW 27TH STPARCEL NO. 0886700100MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 914Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #9 - USE SET-UP WHERE APPLICABLE ALONG NANCHES AVE SW (NORTH AND SOUTH BOUND DIRECTIONS)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESROADWORKAHEADWORKVEHICLEW20-1W20-5LW1-4LXXW20-1W20-1W20-150' - 100'NANCHES AVE SWSW 27TH STLEFTLANECLOSEDAHEAD2715 NACHES AVE SWPARCEL NO. 08867002702700 NACHES AVE SWPARCEL NO. 0886700330OFFICER REQUIRED TOMONITOR / CONTROLTRAFFIC WHEN WORKINGIN INTERSECTION.MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1014Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - ONE-LANE, TWO-WAY CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #10 - USE SET-UP WHERE APPLICABLE ALONG NANCHES AVE SW (NORTH AND SOUTH BOUND LANES)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICES50' - 100'50'±ROADWORKAHEADONE LANEROADAHEADWORKVEHICLE50' - 100'W20-1W20-4W20-7XXXW20-1W20-4W20-7XXXNACHES AVE SW2715 NACHES AVE SWPARCEL NO. 08867002702700 NACHES AVE SWPARCEL NO. 0886700330FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLMFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1114Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE AND BIKE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #11 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (SOUTH BOUND LANE)CITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADWORKVEHICLE L/2L MINLBIKESMERGEWITHTRAFFICW20-1W4-1BW1-4LXXXW20-5RW4-2RXXW20-1W20-5RW20-1X W20-5RW20-1X 50' - 100'BIKE LANEBIKE LANEOAKESDALE AVE SWSW 27TH STPARCEL NO. 0886700400PARCEL NO. 2523049004PARCEL NO. 2523049001PARCEL NO. 0886700170MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1214Know what'sbelow.before you dig.CallRCITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND 35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLNORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADBIKESMERGEWITHTRAFFICWORKVEHICLEW20-1W4-1BW1-4LXXXW20-5RW4-2RXXL/2L MINLOKR3-6RW20-1W20-1W20-1BIKE LANEBIKE LANESHORT-TERM STATIONARY WORK ZONE - LANE AND BIKE LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN STREET)TRAFFIC CONTROL PLAN #12 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (SOUTH BOUND LANE)OAKESDALE AVE SWSW 27TH STPARCEL NO. 0886700170PARCEL NO. 2523049001NOTESPOTTER FLAGGERS ON SITE TOESCORT PEDESTRIANS AROUNDTHE WORK AREA. PLACETEMPORARY ADA RAMPS AT THEENDS OF THE TRANSITION AREA ASNEEDED TO DETOUR PEDESTRIANSTHROUGH THE STAGING AREA.SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYMFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1314Know what'sbelow.before you dig.CallRCITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND 35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLNORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADBIKESMERGEWITHTRAFFICSHORT-TERM STATIONARY WORK ZONE - LANE AND BIKE LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN STREET)TRAFFIC CONTROL PLAN #13 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (SOUTH BOUND LANE)OAKESDALE AVE SWNOTESPOTTER FLAGGERS ON SITE TOESCORT PEDESTRIANS AROUNDTHE WORK AREA. PLACETEMPORARY ADA RAMPS AT THEENDS OF THE TRANSITION AREA ASNEEDED TO DETOUR PEDESTRIANSTHROUGH THE STAGING AREA.SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYW20-1W4-1BW1-4LXXXW20-1L/2L MINL50' - 100'W20-5RW4-2RXXPARCEL NO. 0886700200PARCEL NO. 08867002501300 SW 27TH STPARCEL NO. 0886700100MFP21001633 NO.123PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPSCLIENT ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING TCPs.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1414Know what'sbelow.before you dig.CallRCITY OF RENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND 35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKY.COMHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESROADWORKAHEADRIGHTLANECLOSEDAHEADBIKESMERGEWITHTRAFFICSHORT-TERM STATIONARY WORK ZONE - LANE AND BIKE LANE CLOSURE (FOR URBAN STREET)TRAFFIC CONTROL PLAN #14 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (SOUTH BOUND LANE)SCOPE OF WORK:USE PROPOSED WORK ZONE TO ACCESS ANDPROOF EXISTING CTL/LUMEN VAULT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYW20-1W4-1BW1-4LXXXWORKVEHICLE L/2L MINLW20-5RW4-2RXXW20-1OAKESDALE AVE SW1901 OAKESDALE AVE SWPARCEL NO. 0886700210PARCEL NO. 0886700240MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: R© 2021 Microsoft Corporation © 2021 TomTom SITE LOCATIONSHEET INDEXSCOPE OF WORK:PROOF EXISTING CTL/LUMEN VAULTS ANDCONDUIT ALONG W 27TH ST FROM JUSTWEST OF E VALLEY RD ST TO NACHES AVESW, ALONG NACHES AVE SW SOUTH OF W27TH AVE, AND ALONG OAKSDALE AVE SWNORTH OF W 27TH ST.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 125ADDRESS: 300 SW 27TH ST, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS1.COVER SHEET / SITE LOCATION2.LEGEND3.GENERAL NOTES4-23.DESIGN VIEWS A-T24-25.SITE PHOTOSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMNORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C.206.305.5881MSMITH@NORTHSKY.COMSHEET 4SHEET 23SHEET 12SHEET 16SHEET 18SHEET 19MFP21001633This permit is for Major construction work in the ROW and will be billed at an additional$60/HR for inspections. After hours and weekend work will be billed at $125/HR NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 225#F#F#F##LEGENDMFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 325The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRSW 27TH STCONFIDENTIAL/PROPRIETARYSHEET: OF 425PLAN VIEW A CONSTRUCTION NOTESMATCH TO SHEET 5 300 SW 27TH STPARCEL NO. 2193100010299 SW 27TH STPARCEL NO. 125380011091'36'12'13'11'312'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.1MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 525PLAN VIEW B CONSTRUCTION NOTESMATCH TO SHEET 4 MATCH TO SHEET 6 SW 27TH STLIND AVE SW 2700 LIND AVE SWPARCEL NO. 1253800120PARCEL NO. 219310009092'56'12'10'12'11'11'372'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 625PLAN VIEW C CONSTRUCTION NOTESMATCH TO SHEET 5 MATCH TO SHEET 7 SW 27TH STLIND AVE SWPARCEL NO. 12538100902423 LIND AVE SWPARCEL NO. 302305908689'43'22'10'10'111'261'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 725PLAN VIEW D CONSTRUCTION NOTESMATCH TO SHEET 6 MATCH TO SHEET 8 SW 27TH STPARCEL NO. 12538100902423 LIND AVE SWPARCEL NO. 302305908691'43'10'10'22'372'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 825PLAN VIEW E CONSTRUCTION NOTESMATCH TO SHEET 7 MATCH TO SHEET 9 SW 27TH STSPRINGBROOK CREEK PARCEL NO. 12538100902423 LIND AVE SWPARCEL NO. 3023059086PARCEL NO. 2523049004800 SW 27TH STPARCEL NO. 252304906492'43'10'10'22'340'34'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.3MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 925PLAN VIEW F CONSTRUCTION NOTESMATCH TO SHEET 8 MATCH TO SHEET 10 SW 27TH STPARCEL NO. 2523049004800 SW 27TH STPARCEL NO. 252304906492'43'10'10'22'372'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1025PLAN VIEW G CONSTRUCTION NOTESMATCH TO SHEET 9 MATCH TO SHEET11SW 27TH STPARCEL NO. 2523049004800 SW 27TH STPARCEL NO. 25230490641100 SW 27TH STPARCEL NO. 252304905891'47'12'10'24'182'190'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.4MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1125PLAN VIEW H CONSTRUCTION NOTESMATCH TO SHEET 10 MATCH TO SHEET 12 SW 27TH STPARCEL NO. 25230490041100 SW 27TH STPARCEL NO. 2523049058PARCEL NO. 252304900190'54'10'10'12'21'372'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1225PLAN VIEW I CONSTRUCTION NOTESMATCH TO SHEET 11 MATCH TO SHEET 13 MATCH TO SHEET 19SW 27TH STOAKESDALE AVE SWPARCEL NO. 0886700170PARCEL NO. 0886700400PARCEL NO. 2523049004PARCEL NO. 252304900190'60'12'12'12'11'12'34'140'9'187'145'42'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.222221111CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.5611MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1325PLAN VIEW J CONSTRUCTION NOTESMATCH TO SHEET12MATCH TO SHEET14 SW 27TH STPARCEL NO. 0886700170PARCEL NO. 0886700390PARCEL NO. 088670040090'24'24'12'12'12'12'350'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1425PLAN VIEW K CONSTRUCTION NOTESMATCH TO SHEET13MATCH TO SHEET15SW 27TH ST2700 NACHES AVE SWPARCEL NO. 0886700330PARCEL NO. 0886700170PARCEL NO. 088670039090'24'24'12'12'108'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.11224'2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1525PLAN VIEW L CONSTRUCTION NOTESMATCH TO SH E E T 14 MATCH TO SHEET16SW 27TH ST2700 NACHES AVE SWPARCEL NO. 08867003301300 SW 27TH STPARCEL NO. 0886700100PARCEL NO. 0886700160PARCEL NO. 088670017091'60'14'11'11'12'286'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1625PLAN VIEW M CONSTRUCTION NOTESMA T C H T O S H E E T 15 SW 27TH STNACHES AVE SWMATCH TO SHEET 172715 NACHES AVE SWPARCEL NO. 08867002702700 NACHES AVE SWPARCEL NO. 08867003301300 SW 27TH STPARCEL NO. 08867001001300 SW 27TH STPARCEL NO. 088670010090'14'27'13'38'12'11'14'15'168'61'19'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2222111CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.78MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1725PLAN VIEW N CONSTRUCTION NOTESMATCH TO SHEET 16 MATCH TO SHEET18NACHES AVE SW2715 NACHES AVE SWPARCEL NO. 08867002702700 NACHES AVE SWPARCEL NO. 088670033041' 13' 13' 12' 10'11'39'177'197'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.9MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1825PLAN VIEW O CONSTRUCTION NOTESMATCH TO SHEET 17NACHES AVE SW2715 NACHES AVE SWPARCEL NO. 08867002702700 NACHES AVE SWPARCEL NO. 088670033023'11'12'88'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.10MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1925PLAN VIEW P CONSTRUCTION NOTESMATCH TO SHEET 12MATCH TO SHEET 20OAKESDALE AVE SWPARCEL NO. 0886700170PARCEL NO. 2523049001PARCEL NO. 088670018066'11'11'11'11'11'206'166'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.12MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 2025PLAN VIEW Q CONSTRUCTION NOTESMATCH TO SHEET19MATCH TO SHEET 21OAKESDALE AVE SWPARCEL NO. 2523049001PARCEL NO. 08867001801300 SW 27TH STPARCEL NO. 0886700100PARCEL NO. 000580001967'11'11'13'11'11'333'39'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.132MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 2125PLAN VIEW R CONSTRUCTION NOTESMATCH TO SHEET20MATCH TO SHEET 22OAKESDALE AVE SW1300 SW 27TH STPARCEL NO. 0886700100PARCEL NO. 0005800019PARCEL NO. 088670020066'11'11'13'11'11'372'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 2225PLAN VIEW S CONSTRUCTION NOTESMATCH TO SHEET21MATCH TO SHEET 23OAKESDALE AVE SWPARCEL NO. 0886700200PARCEL NO. 088670025090'66'11'11'13'11'11'88'284'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.14MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 2325PLAN VIEW T CONSTRUCTION NOTESMATCH TO SHEET22OAKESDALE AVE SWPARCEL NO. 08867002501901 OAKESDALE AVE SWPARCEL NO. 0886700210PARCEL NO. 088670024091'67'11'11'13'11'11'217'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #24-25 FOR SITE PHOTOGRAPHS.15MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRPHOTO #1: FACING WEST ON EAST SIDE OF SW 27TH STPHOTO #5: FACING NORTH ON EAST SIDE OF SW 27TH STPHOTO #7: FACING EAST ON EAST SIDE OF SW 27TH STPHOTO #8: FACING NORTH ON SOUTH SIDE OF NACHES AVE SWPHOTO #9: FACING WEST ON SOUTH SIDE OF NACHES AVE SWCONFIDENTIAL/PROPRIETARYSHEET: OF 24251EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12122PHOTO #2: FACING WEST ON EAST SIDE OF SW 27TH STPHOTO #3: FACING WEST ON EAST SIDE OF SW 27TH ST122PHOTO #4: FACING WEST ON EAST SIDE OF SW 27TH ST122221122PHOTO #6: FACING EAST ON EAST SIDE OF SW 27TH ST12212212122MFP21001633 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 15NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 15 - PROOFING PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 2525PHOTO #10: FACING NORTH ON SOUTH SIDE OF NACHES AVE SWPHOTO #11: FACING NORTH ON WEST SIDE OF SW 27TH STPHOTO #12: FACING SOUTH ON SOUTH SIDE OF OAKESDALE AVE SWPHOTO #15: FACING WEST ON SOUTH SIDE OF OAKSDALE AVE SW1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122122122PHOTO #13: FACING SOUTH ON SOUTH SIDE OF OAKESDALE AVE SWPHOTO #14: FACING SOUTH ON SOUTH SIDE OF OAKESDALE AVE SW12212MFP21001633