Loading...
HomeMy WebLinkAboutzR-4141SetT It T I W w z J <L FOUND 2" DISK W/PUNCH IN CONC IN CASE DOWN 0.5' ® INTX. 160TH AVE SE AND SE 136TH ST 1' SOUTH OF 1/4 SECT LINE .VICES fH AVE S, WA 98026 GINEERING SERVICES PLLC qD PL SW UNIT#B RR -8291 3INEERING@GMAIL.COM GEOTECHNICAL ASSOCIATES, INC. 35TH AVE NE, SUITE A-500 ✓ILLE, WA 98072 1669 LSONGEOTECH.COM 3EOMATIC SERVICES, INC RUS WAY, SUITE 105, D, WA 98275 1620 )eoinc.com D DALE ROPPE 30TH AVE SE WA 98059 97 )TH AVE SE WA 98059 )GRAPHIC SURVEY 'LAN .ITY PLAN N IN 5 0 10 20 ;ALE: 1 INCH = 10 FEET RENTON STANDARDS IEGIONAL FIRE AUTHORITY APPROVED cthomas 02/22/2021 07-22-2020 ;Ua:F DRAWING NO: C1.0 SHEET: 1 OF: 9 M 1 l O O ^O u a IIr ILL w o— n O rr 20 10 0 20 40 SCALE IN FEET LEGEND ® FOUND MONUMENT (AS NOTED) O FOUND REBAR (AS NOTED) SS SANITARY SEWER MANHOLE ® CATCH BASIN (CB) SD STORM DRAIN MANHOLE pQ WATER VALVE ® WATER METER 0 GAS VALVE Q� MAILBOX HHO HAND HOLE JBO ELECTRIC JUNCTION BOX EM® ELECTRIC METER UTILITY POLE WITH LIGHT -0- UTILITY POLE CONIFEROUS TREE 0 DECIDUOUS TREE OHW OVERHEAD WIRE CONC CONCRETE IE INVERT ELEVATION SSMH SANITARY SEWER MANHOLE SD STORM DRAIN LINE SS SANITARY SEWER LINE x FENCE ROCKERY - CENTERLINE - - RIGHT OF WAY - - - - - - - PLAT LOT LINE PROPERTY LINE CITY OF RENTON MON. NO. 478 1 /8" PIN IN CONC. POST IN MON CASE ® INTX. UNION AVE SE & SE 2ND ST TOPOGRAPHIC & BOUNDARY SURVEY SW 1/4, SE 1/4, SEC. 14, T. 23 N., R. 5 E., W.M. KING COUNTY, WASHINGTON CITY OF RENTON MON. NO. 1852 \\� s 3" BRASS SURFACE MON. W/PUNCH ® INTX. NILE AVE NE & NE 4TH ST \\\`� FOUND 2" DISK W/PUNCH IN CONC IN CASE DOWN 0.5' ® INTX. 160TH ` AVE SE AND SE 136TH ST 1' SOUTH OF 1/4 SECT LINE I I 30' 30' 0 FOUND 1/2" REBAR 0 11 0 W/ILLEGIBLE CAP w w c4 0.4' SOUTH OF CALC POSITION _Li Q 4CHAINLINK CONC. ccn o 6' WOOD 4' CHAINLINK � o FENCE PAVERS 4' CHAINLINK FENCE FENCE z N88'18'09"W 165.04 FENCE (c; 1.6' GATE FOUNTAIN - - 10" �- - — GAZEBO RR TIE 8" x2 ®JB 10" BORDER � 8" 10'� 12" � `� GARAGE z 5��� c�Lu SHED ROCK WALL C o 0p o / � ROCK / -- WOOD RR TIE Q STEPS co i ROCK FOOT BORDER o IE-441 �31 m 10 GRASS z z w WALL BRIDGE 8" x3 4' WOOD zNCE o s � 3af 14 o i 00- X w 11110 6' WOOD SHED 0 z Mo FENCE , SPLIT O RAIL in u �_ FENCE o w RR TIE ASPHALT z 0 Sp ri BORDER DRIVEWAYEND 4' DECK WOOD FENCE RR TIEQ o aj I BORDER z 10 x3 W W -------� i i cn c _cn i CARPORT APPROX. i � � > i BORDIER i CONC. LOCATION i- i i PAVERS SEPTIC TANK i GAS G S Q CHIMNEY HOUSE PER COUNTY i SPLIT Q Q i GATE #14005 AS -BUILT 0 RAIL w v - -�i FENCE < APPROX. cn = LOCATION zo �' c°n OLD OIL TANK / v SS c zo GARAGE Q o 0 M GATE w GRASS EM PLANTER i o i i L i i BRICK = cn i - - ASPHALT DECK F — BORDER O DRIVEWAY W/STAIRS — ----J GATE PLANTER ' F2'x3' STEELE OVER APPROX. LOCATION i �30.01ULVERT OF DRAIN FIELD W/THREE _ PER COUNTY ASPHALT CONDUIT o o I AS -BUILT DRIVEWAY to '7 < S88'18'09"E 165 04Ir o HH N o N I CATV W W15' INGRESS/EGRESS AND FOUND 1/2" REBAR o UTILITY EASEMENT PER W/ILLEGIBLE CAP - V) DEED NO. 8709020014 0.4' SOUTH OF ICD N w N SSMH CALC POSITION N RIM=441.98 I o I CTR. CHANNEL=429.9 LO o� o � z Q CD o c I c SSMH RIM=439.52 SS )CTR. CHANNEL=428.2 At;721848''w o 860 .19 co I N A i i I FOUND 2" IP IN CASE DOWN 0.5' ® INTX. 160TH AVE SE AND SE 144TH ST �FOUND 2" DISK W/PUNCH IN CONC IN CAS DOWN 0.5' ® INTX. 160TH AVE SE AND SE 140TH ST SE 140TH ST. LEGAL DESCRIPTION (PER STATUTORY WARRANTY DEED RECORDING NO. 8709020014) THE WEST 165 FEET OF THE EAST 195 FEET OF THE NORTH 132 FEET OF THE NORTHEAST 1/4 OF THE SOUTHWEST 1/4 OF THE SOUTHEAST 1/4 OF SECTION 14, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. TOGETHER WITH A NON-EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS AND FOR UTILITY PURPOSES OVER, ACROSS, AND THROUGH THE SO.15 FEET OF THE EAST 165 FEET OF THE NORTH 132 FEET OF THE WEST 165 FEET BASIS OF BEARING THE BASIS OF BEARING FOR THIS SURVEY IS NORTH 00`25'16" EAST BETWEEN FOUND MONUMENTS ALONG THE CENTERLINE OF 160TH AVE SE AS SHOWN HEREON. VERTICAL DATUM THE VERTICAL DATUM FOR THIS SURVEY IS NAVD 88, BASED ON RTK GPS OBSERVATIONS VIA THE WASHINGTON SPATIAL REFERENCE NETWORK (WSRN) STATI STI CS EQUIPMENT: TRIMBLE VX ROBOTIC TOTAL STATION AND TRIMBLE R8 GNSS RECEIVER METHODOLOGY: FIELD TRAVERSE. MEETS OR EXCEEDS SURVEY STANDARD AS PER: WAC 332-130-050 WAC 332-130-090 WAC 332-130-100 ALL SURVEY WORK OCCURRED IN MARCH OF 2018 REFERENCES 1. PLAT OF MINDY'S PLACE, AFN 20171201000001 2. PLAT OF NICHOLS PLACE, VOL. 231, PG. 1 3. RECORD OF SURVEY AFN 9508099008 SURVEYOR'S NOTES 1. ALL UNDERGROUND UTILITY LOCATIONS ARE BASED ON OBSERVED EVIDENCE OF STRUCTURES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE SURVEYOR DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION PROVIDED. 2. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A COMPLETE TITLE REPORT, WHICH MAY REVEAL ADDITIONAL RESTRICTIONS AND EASEMENTS OF RECORD. 3. LOCATIONS OF THE SEPTIC TANK AND DRAINFIELD ARE SHOWN PER KING COUNTY AS -BUILT MAP. 4. OIL TANK LOCATION IS SHOWN PER INFORMATION FROM THE PROPERTY OWNER. R-414102 � � Q W O �a 0 zz O � xI Q � � 0 o I I No N r--I W O � N O � Z O `J O w a M—I Q �O Z W W U Up m u Lr) W uj H Q o Z) L -�dU cntio N N — � Z� QrnCD a°� �<r �� �a �D >_Ow� ULu ZQ oY0Ljj oo V as �Z)�� U V Z Q. U W o Q 0 00 Ow M--I Op Ld �z� O o w (� Q a � rx z U W o Q 0 J O z O U z O z w L, O r U Ld Q W CHAINLINK PAVERS FENCE 6' 4, WOOD CHAINLINK FENCE FENCE N88"1809"W 165.04 GATE FOUNTS 7.5 - GA�EB0. RR �- BSBL GARAGE I t�0 RDER�- 7 -( 4 / �q I9 RO K Z LL / o ROCK - - WOOD O / STEPS 3 WALL GRASS N U� 0D k10E I 1 N I I � I I I N A47 I I Z / DECK 0 I J 12 TYPx �I-------- j I� I IRR I CARPORT I APPRO I I I TIE KTgp7t I CONC. '1-F. PAVERS TBD 1ONRa CHIMNEY HOUSE \ 14 I c I C I I I #14005 -GTM UILT I C �I c� � I REMAIN )_D I I )IL JK = I I ci E ISTING I o G AGE ir I I o Ia 9 DRIASPIIAL DECK ��A W/STAIR � /AAA / o zzz / 2'x3' STEEL PLATE _ OVER CULVERT , S8818'09"E 165.04 LESS AND BENT PER )9020014 DRIP LINES SHOWN ON PLANS ARE NOT CONSISTENT WITH AERIAL IMAGES. TREE PROTECTION FENCING SHALL BE REVISED TO BE LOCATED OUTSIDE OF THE ACCURATE DRIP LINE, PER THE REQUIREMENTS BELOW, PRIOR TO DEVELOPMENT ACTIVITIES. THE STOCKPILE SHALL BE RELOCATED OUTSIDE OF THE DRIP LINES AND TREE PROTECTIONS FENCING. TREE PROTECTION SHALL BE VERIFIED FOR COMPLIANCE WITH THE CODE REQUIREMENTS VIA CITY INSPECTION PRIOR TO DEVELOPMENT ACTIVITIES. PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET (1.25) FOR EVERY ONE INCH 0 ") OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50') INDICATING THE WORDS, "NO TRESPASSING -- PROTECTED TREES," OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET (50'). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES. i w APPROX. LOCATION OF DRAIN FIELD =S-�OILT� 1 al 2 - BORDER EXISTING SW 1/4 OF THE SE 1/4, SEC. 14, T 23N9 R 05E, W.M. I � I O , I I V II W N x � N FOUND 1/2" REBAR 10 N I W/ILLEGIBLE CAP 0.4' SOUTH OF CALC POSITION 4' I 5 IN INK / 1 TO PREMAIN HALT RIVEWAY�, FOUND 1/2" REBAR W/ILLE Bic LE CAP 0.4' SOUTH OF CALC POSITION CATV RIM=4 IE=436. 1 1 ,WIN 1 1 7 (n Cn Q I c� I VO) I CONSTRUCTION NOTES OUTILIZE EXISTING DRIVEWAY DURING INITIAL PHASE OF MOBILIZATION AND SITE PREPARATION AND DEMOLITION. EXISTING DRIVEWAY TO BE REMOVED. OSTABILIZED CONSTRUCTION ENTRANCE PER DETAIL ON SHEET C2.1 a. ° O SAWCUT FULL DEPTH d. O FILTER FABRIC (SILT) FENCE PER DETAIL ON SHEET C2.1 ° O STORM INLET PROTECTION PER DETAIL ON SHEET C2.1 1d: .'e' D e O PLASTIC COVERED STOCKPILE PER DETAIL ON SHEET C2.1 C 1.. REMOVE EXISTING STRUCTURES f OREMOVE EXISTING FENCES, WALLS, RR TIES, AND TANK CB 54"0 ° EI(18"N)=439.86 O REMOVE ON -SITE PAVING IE(24"N W)=439.61 IE(30"S)=438.91 SEPTIC TANK AND DRAINFIELD. SEE REMOVAL NOTES 11 REMOVE 8 LF OF 24" CPEP I +d �au�.ui.ae y CAN. CNMINF1r .9 12 6' HIGH CHAIN LINK TREE PROTECTION FENCING FOUND 2" DISK •f` + W/PUNCH IN CONC IN CASE DOWN 0.5' ® INTX. ' 160TH AVE SE AND SE 140TH ST a. 'A s EARTHWORK QUANTITIES CUT = 50 CY o FILL = 50 CY V) SEIIdOTH ST. i NET = 0 CY FILL 0 a C� U) I 1n SMH RIM=439.52 CTR. CHANNEL=428.2 LEGEND X SILT FENCE ASPHALT/CONCRETE TO BE REMOVED O�O CONSTRUCTION ACCESS LIMITS OF CLEARING AND GRADING INLET PROTECTION 000000 STOCKPILE AREA SAWCUT/LIMITS OF GRIND { EXISTING SURVEYED TREES TO REMAIN EXISTING TREE TO BE REMOVED TREE PROTECTION FENCING TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. REVISION SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE AP P R APPRovED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY R-414103 1 /712021 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CONSTRUCTION SEQUENCE 1. CONTRACTOR TO ARRANGE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON PRIOR TO BEGINNING SITEWORK. 2. IDENTIFY AND MARK LIMITS OF CLEARING. 3. A COPY OF THE APPROVED TESC/SWPP PLAN IS TO BE KEPT ONSITE AT ALL TIMES DURING CONSTRUCTION. 4. INSTALL TEMPORARY ROCK CONSTRUCTION ENTRANCE, FILTER FABRIC FENCES, AND CATCH BASIN INSERTS AS REQUIRED. 5. A MINIMUM OF ONE SET OF APPROVED CONSTRUCTION DRAWINGS AND A COPY OF THE CITY OF RENTON DESIGN AND CONSTRUCTION STANDARDS SHALL BE MAINTAINED IN GOOD (LEGIBLE) CONDITION ONSITE AT ALL TIMES. 6. BEGIN SITE GRADING AND UTILITY INSTALLATION GRADE AND PAVE ACCESS DRIVEWAY. 7. CONSTRUCT FRONTAGE IMPROVEMENTS 8. A TRAFFIC CONTROL PLAN IS TO BE SUBMITTED BY THE CONTRACTOR TO THE CITY OF RENTON AND APPROVED BY THE CITY PRIOR TO ANY SITE RELATED ACTIVITIES (INCLUDING OFFSITE UTILITY CONNECTIONS) THAT REQUIRE ROAD CLOSURE OR DISRUPTION OF ACCESS TO NEARBY BUSINESSES THAT WILL LAST MORE THAN 15 MINUTES. 9. MAINTAIN TESC FACILITIES IN PROPER OPERATING CONDITION DURING ALL PHASES OF CONSTRUCTION. RELOCATE TESC FACILITIES AS NEEDED AS CONSTRUCTION PROGRESSES. 10. COORDINATE UTILITY CONSTRUCTION AND CONNECTIONS WITH UTILITY PROVIDERS. 11. COMPLETE ONSITE, OFFSITE AND BUILDING CONSTRUCTION AND OBTAIN CIYT/UTILITY PROVIDER APPROVAL. INSTALL LANDSCAPING IN CONFORMANCE WITH LANDSCAPE PLANS. STABILIZE ALL EXPOSED AREAS. 12. REMOVE REMAINING TESC MEASURES AS DIRECTED BY THE CITY OF RENTON INSPECTOR AFTER CITY APPROVAL. SEPTIC SYSTEM ABANDONMENT NOTES: 1. CONTRACTOR SHALL PREPARE A SEATTLE AND KING COUNTY PUBLIC HEALTH "REPORT OF WASTE WATER TANK ABANDONMENT" APPLICATION AND RETURN COMPLETED FORM TO PUBLIC HEALTH - SEATTLE & KING COUNTY, ENVIRONMENTAL HEALTH DIVISION, 14350 SE EASTGATE WAY,BELLEVUE, WA, 98007, TEL. (206) 296-4932. 2. PRIOR TO ABANDONMENT THE SEPTIC TANK AND ALL SEWAGE EFFLUENT IN DRAIN FIELD MUST BE PUMPED AND DISPOSED OF BY A WASHINGTON STATE CERTIFIED LIQUID WASTE PUMPER HAULER TO AN APPROVED DISPOSAL FACILITY. 3. THE SEPTIC TANK AND DISTRIBUTION STRUCTURES MUST BE REMOVED AND DISPOSED OF PROPERLY. 4. PRIOR TO REMOVAL OF ANY TYPE OF "DRAINFIELD," THE SYSTEM MUST BE ALLOWED A DRYING OUT PERIOD OF SIXTY (60) DAYS OR LONGER BEFORE REMOVAL TO ENSURE THAT NO LIQUID SEWAGE EFFLUENT IS PRESENT. THIS WILL MINIMIZE THE POTENTIAL FOR DIRECT HUMAN CONTACT WITH ANY SEWAGE AND HELP PREVENT SPILLS OR LEAKAGE ON BOTH PRIVATE PROPERTY AND PUBLIC ROADWAYS. 5. THE GEO-TEXTILE FABRIC AND DISTRIBUTION PIPING OR SYNTHETIC MEDIA MUST BE REMOVED, DRIED AND DISPOSED OF AT A PERMITTED SANITARY LANDFILL AS MUNICIPAL SOLID WASTE. THIS MATERIAL MUST NOT BE MIXED WITH THE SOIL IF THE SOIL IS TO BE REUSED OR SPREAD. 6. THE DISTRIBUTION MEDIA, IF ROCK, MUST BE HAULED OFF SITE FOR BURIAL OR STOCKPILING IN A REMOTE LOCATION TO MINIMIZE HUMAN EXPOSURE TO POTENTIAL PATHOGENS AND ALLOW FOR PATHOGEN DIE -OFF. 7. BACKFILL WITH CLEAN GRAVEL OR FILL SOIL. FUM 4715 142nd PI. SW #B, Edmonds, WA 98026 ph 206.890.8291 CITY OF RENTON Planning/Building/Public Works Dept. He a • T11*+T Know what's below. 20 10 0 20 40 Call before you dig. SCALE: 1 INCH = 20 FEET IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Ar IL Nathan Janders 02/19/2021 L RRENT PLANNING } LL aweihs 02/19/2021 0 DATE: W 07-22-2020 0- R O P P E S F R FIELDBOOK: PAGE: O TESC PLAN DRAWING SHEET: 3 OF: 9 T DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 I w I- ,`��10' - 1 TOE IN SHEETING IN__/ 4" x 4" MIN. TRENCH `'Li i ti LI-Ini.i= ��ki 11I' PROVIDE ENERGY DISSIPATION AT TOE IF EROSION IS LIKELY - SANDBAG (TYP.) 10' MAX. NOTES: 1. CONDITIONS OF USE 1.1. PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 1.2. PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES. 1.3. CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY -SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH'... CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1.4. THIS METHOD SHALL NOT BE USED UPSLOP_EOFAREA&J}IATMIGHTI3E,A[Djf€RSEUYIMPACTEO.pY RU�IQFF._SUCIi ARFA$INCLUG,E,ST€EP ANp7. UNSTABLE SLOPES. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF 0.06 MILLIMETERS. 2.2. IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTIONSHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 2.3. TIRES, SAND BAGS, OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC. 2.4. SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3.. MAINTENANCE STANDARDS 3.1. TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2. IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED. 3.3. WHEN THE PLASTIC IS NO LONGER NEEDED, IT SHALL BE COMPLETELY REMOVED. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NT5) PUBLIC WORKS PRO STD. PLAN - 213.30 •�• ',„ DEPARTMENT PLASTIC COVERING GAZ 9/28/2018 I :45 am1,1w,,14"-..,,...,..,, DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS EX`5T\NG aOPO 4"-8" QUARRY SPALLS 12" MIN. THICKNESS CONSTRUCTION ENTRANCE NOTES: 1. DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE, CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15' MIN. PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. "2 iFOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTH/WIDTH TO PROVIDE VEHICLE ACCESS/PARKINC.,_BASED ON LOT SIZE/CONFIGURATION:. 2, DESIGN AND INSTALLATION SPECIFICATIONS 1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT -.€ROM PUMPING UP INTO THE_R KPAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 495 LBS. MIN. ADS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 22. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 23. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2A. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY. INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF. SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL? WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. O.L'3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 215.10 PUBLIC WORKS nPPR°vED URDEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 :45 ..,..,.,...,,.............,.... DATE Lii Lq a SW 1/4 OF THE SE 1/4, SEC. 14, T 23N, R 05E, W.M. DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 I DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED --�� FILTER FABRICMna _ _ - - _ _ _ _ _ _ _ - 6' MAX. �I POST SPACING MAY BE INCREASED L 12" MIN. I TO 8' IF WIRE BACKING IS USED � 4"x4" MIN. TRENCH r) I BACKFILL TRENCH WITH NATIVE SOIL I� OR 3/4" TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMO_IUNTS OF OVERLAND FLOW ANY CONCENTRATED;' FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.115mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SEC'MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30 % MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF'THEIFENCE, WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2 IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP ORPOND. 13j IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.41 SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH. 3;59 1F THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. PUBLIC WORKS DEPARTMENT DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 214.00 P SILT FENCE GAZ 9/28/2018 :45 DATE 5" MAX. DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS J a BELOW INLET GRATEt2EV10E: SEDIMENT AND DEBRIS FILTERED WATER - SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.) wo BELOW INLET GRATE DEVICE ISOMETRIC VIEW OVERFLOW BYPASS(TYP.) NOTES: L PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT; POND OR TRAP., ',2d INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. E3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE:, -4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). LBL,. 'ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE [STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216.30 } PUBLIC WORKS Ll E°'DEPARTMENT CATCH BASIN INSERT AZ 9/28/2018 :45 oks DATE NO. I REVISION EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL(ESSC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT;rMAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING' NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC'. ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY Or RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT, ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL, BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE'. WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE'. COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY, 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITEr ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 0PUBLIC WORKS EROSION AND SEDIMENT CONTROL [PPROVID DEPARTMENT STANDARD PLAN NOTES GAZ 9/28/2018 1 9:45 Public Wotks ndministtator. DATE THE 13 ELEMENTS OF A CONSTRUCTION SWPPP 1. PRESERVE VEGETATION/MARK CLEARING LIMITS: THE CLEARING LIMITS ARE INDICATED ON THE PLAN SHEET. FURTHERMORE, CLEARING AND GRADING WILL BE LIMITED TO ONLY AREAS THAT NEED TO BE DISTURBED FOR GRADING/ CONSTRUCTION OF THE SITE AND FRONTAGE IMPROVEMENTS. CONSTRUCTION WILL REQUIRE REGARDING THE ENTIRE SITE. FIELD MARKING THE CLEARING LIMITS SHALL BE COMPLETED PRIOR TO CLEARING AND GRADING ACTIVITIES. BMPS: PRESERVE NATURAL VEGETATION (VEG) 2. ESTABLISH CONSTRUCTION ACCESS: ACCESS TO THE CONSTRUCTION SITE SHALL BE LIMITED TO THE ROCK CONSTRUCTION ENTRANCE. THE ROCK CONSTRUCTION ENTRANCE SHALL BE INSTALLED OFF OF THE STREET TO PROVIDE ACCESS TO THE CONSTRUCTION VEHICLE/EQUIPMENT STAGING AND EMPLOYEE PARKING AREAS. BMP'S: ROCK CONSTRUCTION ENTRANCE (CE) 3. CONTROL OF FLOW RATES: STORM WATER DETENTION: NO DETENTION IS PROPOSED FOR THE SITE SINCE THE WORK SHOULD BE COMPLETED IN A SHORT PERIOD OF TIME. BMP'S NONE PROPOSED 4. INSTALLATION OF SEDIMENT CONTROLS: SEDIMENT CONTROL WILL BE PROVIDED THROUGH A COMBINATION OF FILTRATION THROUGH THE SURROUND ON -SITE VEGETATION, OR FILTER FENCE IF REQUIRED BMP'S: SILT FENCE (SF) 5. SOILS STABILIZATION: TEMPORARY AND PERMANENT SOIL STABILIZATION WILL BE PROVIDED. TEMPORARY STABILIZATION WILL BE PROVIDED THROUGH THE APPLICATION OF STRAW AND/ OR PLASTIC SHEETING TO EXPOSED, WORKED EARTH. FROM OCTOBER 1 UNTIL APRIL 30, NO EXPOSED SOIL MAY REMAIN EXPOSED AND UNWORKED FOR MORE THAN TWO DAYS; AFTER MAY 1, NO EXPOSED SOIL MAY REMAIN EXPOSED AND UNWORKED FOR MORE THAN SEVEN DAYS. BMP'S: STRAW COVERING, PLASTIC SHEETING, FINAL LANDSCAPING(AS REQUIRED) 6. SLOPE PROTECTION: THERE ARE NO SLOPES ON THE SITE. HOWEVER, STOCK PILES SHALL BE PROTECTED FROM EROSION THROUGH COVER AND PREVENTION OF CONCENTRATED SURFACE RUNOFF FLOWS. BMP'S: PLASTIC SHEETING, (AS REQUIRED) 7. PROTECTION OF PERMANENT DRAIN INLETS: INLET PROTECTION WILL BE PROVIDED FOR ALL CATCH BASINS. BMP'S: INLET PROTECTION (IP). 8. STABILIZATION OF CHANNELS AND OUTLETS: ALL CHANNEL SLOPES SHALL BE CONSTRUCTED AND PROTECTED AGAINST EROSION IN ACCORDANCE WITH CITY CODE. BMP'S: NONE REQUIRED 9. POLLUTANT CONTROL: POLLUTANTS SHALL BE CONTROLLED THROUGH THE ON -SITE BMP'S PROPOSED ABOVE. 10. DEWATERING CONTROL: DE -WATERING: INTERCEPTION OF THE WATER TABLE IS NOT EXPECTED TO OCCUR. NO BMP'S ARE PROPOSED. 11. BMP MAINTENANCE: ALL BMP'S AND SWPPP ELEMENTS SHALL BE INSPECTED DAILY AND MAINTAINED AS REQUIRED. 12. PROJECT MANAGEMENT: THE PROJECT SHALL BE MANAGED IN A COOPERATIVE EFFORT BY THE PROJECT MANAGER, CONTRACTOR, ENGINEER, AND THE CITY INSPECTOR. DURING THE CONSTRUCTION PROCESS, IF UNFORESEEN ISSUES ARISE THAT CANNOT BE RESOLVED ON SITE, CONSTRUCTION ACTIVITY (OTHER THAN SWPPP MAINTENANCE) SHALL BE HALTED AND THE OWNER'S REPRESENTATIVE AND THE PROJECT ENGINEER ARE TO BE CONTACTED AND INFORMED OF THE SITUATION. 13. PROTECT LID FACILITIES: INFILTRATION FACILITIES ARE PROPOSED. THE CONTRACTOR IS REQUIRED TO LOCATED THESE AREAS PRIOR TO CONSTRUCTION AND INSTALL A BARRIER (I.E. SILT FENCE OR HIGH-VIS FENCE) AROUND THE FACILITY TO PROTECT THE UNDERLYING SOILS FROM COMPACTION. R-414104 SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE APPR APPROVED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 1 /7/2021 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M 4715 142nd PI. SW #B, Edmonds, WA 98026 ph 206.890.8291 CITY OF RENTON Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ff ` Nathan Janders 02/19/2021 DATE: 07-22-2020 R O P P E S F R FIELDBOOK: PAGE: DRAWING NO: TESC DETAILS C2.1 SHEET: 4 OF: 9 901 a LL U) w I..L O Q� SW 1/4 OF THE SE 1/4, SEC. 14, T 23N,,, R 05E, W.M. CONSTRUCTION NOTES i 0 LU L;j Q Z J a o N I M w.- L0 N 0 z i I I I / I 1 I / I I I I I I I I I I I I I I I I I I I I I I II I I I I .I �I I I I I I I I I I I I I I I I II i I I I I II I I I I I I LXJ DICCL r- LHIC OVER CULVERT JI / co F_ m I I I —41 I L 0---RD RD ROOF DRAIN ROUTING DIAGRAM 3,301SF PORTION OF ROOF TO DISPERSION TRENCH ® 700SF OF NW CORNER TO SPLASH BLOCK ® 700SF OF NORTH SECTION TO SPLASH BLOCK 88°18'09"W 165.04_ FOUNTAIN —El — — — — ,G — BSBL 17n rT S88°18'09"E 165.04 15' INGRESS/EGRESS AND UTILITY EASEMENT PER DEED NO. 8709020014 LEGEND (PROPOSED ❑® CATCH BASIN TYPE 1 O CATCH BASIN TYPE 2 CLEANOUT CONCRETE PROPERTY BOUNDARY EASEMENT LINE STORM — — — — — — 6" STORM SERVICE SURFACE FLOW ARROW 0 YARD DRAIN ASPHALT 20' FOUND 1 /2" REBAR W/ILLEGIBLE CAP 0.4' SOUTH OF CALC POSITION 10» $" 7x2�\ \ F 71 JR EXISTING i ASPHALT DRIVEWAY TO REMAIN HH FOUND 1 /2 REBAR W/ILLEGIBLE CAP 0.4' SOUTH OF CALC POSITION CATV OA POST CONSTRUCTION SOIL AMMENDMENT OPTION 2 (AMEND SOIL IN PLACE) THE SIMPLEST WAY TO RESTORE SOIL QUALITY WHERE THE SOIL HAS BEEN COMPACTED OR THE FOREST DUFF OR TOPSOIL REMOVED IS TO ROTOTILL COMPOST INTO THE EXISTING SOIL. -APPLY A LAYER OF COMPOST TO EXISTING SOIL AT THE PRE -APPROVED AMENDMENT RATE OF 1.75 INCHES FOR TURF AREAS, OR 3 INCHES FOR PLANTING BEDS. USE THE ONLINE COMPOST CALCULATOR AT HTTP://YOUR.KINGCOUNTY.GOV/SOLIDWASTE/COMPOST-CALCULATOR.HTM TO CALCULATE THE AMOUNT OF COMPOST NEEDED. RETAIN COPIES OF RECEIPTS FOR COMPOST DELIVERED TO THE SITE, AS THEY WILL BE USED DURING INSPECTION TO VERIFY THE SOIL REQUIREMENTS HAVE BEEN MET. •ROTOTILL COMPOST INTO SOIL TO A DEPTH OF AT LEAST 8 INCHES. NOTE THAT TILLING TO THIS DEPTH WILL REQUIRE REPEATED PASSES WITH A LARGE MACHINE, SUCH AS A TRACTOR MOUNTED OR HEAVY REAR TINE ROTOTILLER. SURVEYED: DESIGNED: DRAWN: CHECKED: ODRIVEWAY ENTRANCE PER DETAIL SHEET C3.1 OSIDEWALK PER DETAIL SHEET C3.1 OCURB/GUTTER PER DETAIL SHEET C3.1 OPAVEMENT PER DETAIL SHEET C3.1 OASPHALT RAMP DOWN TO STREET LEVEL, 1:12 MAX. SLOPE OFILL-IN EXISTING DITCH WITH IMPORTED SOIL AND TOP SOIL O54" TYPE II CATCH BASIN SEE DETAIL ON SHEET C3.2 OPROPOSED STREET TREE-JAPANESE MAPLE FILLED TRENCH SEE DETAIL COR STD PLAN 224.00 OGRAVEL ON SHEET C3.1 10 SPLASH BLOCK 11 MAIL BOX RELOCATE POWER POLE. UNDERGROUND POWER SERVICE 12 TO PROPOSED ROPPE RESIDENCE 13 INSTALL DEBRIS BARRIER PER COR STD PLAN 223.00 ON SHEET C3.2 14 CB-2 CONCRETE COLLAR SEE DETAIL ON SHEET C3.2 CB 54" 0 RIM=443.46 IE(18"N)=439.86 IE(24"NW)=439.61 IE(30"S)=438.91 SSMH RIM=441.98 CTR. CHANNEL=429.9 FOUND 2" DISK W/PUNCH IN CONIC IN CASE DOWN 0.5' @ INTX. \160TH AVE SE AND SE 140TH ST TH ST co R-4141 Ub 4715 142nd PI. SW #B, ��SSroNALE��� Edmonds, WA 98026 1/7/2021 ph 206.890.8291 SCALE: HORIZONTAL* NAD 1983/1991 AS SHOWN CITY OF R RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY LEGEND (EXISTING ® FOUND MONUMENT (AS NOTED) FOUND REBAR (AS NOTED) O SANITARY SEWER MANHOLE CATCH BASIN (CB) O STORM DRAIN MANHOLE WATER VALVE WATER METER GAS VALVE QO MAILBOX HH • HAND HOLE JB ELECTRIC JUNCTION BOX ELECTRIC METER UTILITY POLE WITH LIGHT UTILITY POLE CONIFEROUS TREE 0 DECIDUOUS TREE OHW OVERHEAD WIRE CONC CONCRETE 1E INVERT ELEVATION SSMH SANITARY SEWER MANHOLE STORM DRAIN LINE SANITARY SEWER LINE FENCE ROCKERY CENTERLINE — RIGHT OF WAY — — — PLAT LOT LINE PROPERTY LINE �G�G1 L a a a , L •0 10 5 0 10 20 Know what's below. Call before you dig. SCALE: 1 INCH = 10 FEET IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: 07-22-2020 R O P P E S F R FIELDBOOK: PAGE: DRAWING NO: ROAD AND STORM PLAN C3.0 SHEET: 5 OF: 9 v (y) t' 1 0 0 0 UN V a ILL U) w 0 SW 1/4 OF THE SE 1/4, SEC. 14, T 23N, R 05E, W.M. DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC1 08 ,, r]_ _ r�jq,lEylr¢tuefssoEVJAuirwJvsi _ I'1- - - 'aL1•+ U �L 'rNARESiaaE NDtE1L. s_ `+s► I ' - - FACE OF CURB 6' _ CEMENT CONCRETE 1R" R. SIDEWALK RAMP 1"R. OR LANDING 6 12" VARIES FROM 1 6• RAISED EDGE DETAIL 1 -a• 6 SIDEWALK vz• LEVEL EXTENDSIDLWALK7RANSVERSE 1'-D' 1'-0' 37d'(IN)PREMOLDEDJOINT FILLER JOINTS TO INCLUDE RAISED EDGE TYPICAL WHERE APPLICABLE 12'0MR ROUr DING 2.. 1 12•(IN)R (rY•P) '► 6" MIN. ,61/2" _ 1" 6" TO O S 1 FOR CURB DETAILS • • . 1.5% SEE STD PLAN 101 � u u IsEE!+OrE e I t+Ot! al �'- 1f2"R. 1"R. 1:24 6" _ d >• ^^:!;�;: 571NG ROADWAY •• r •• `• • • • 1' pN) 0.. / .'• EEY" 1 •••r • : • ti� CRUSHED ROCKBAS�IGLFOF " J t -�� J 12" 12" '-II II--� MIN. MIN. FLOW SECOND l 1 TOP OF T • (p 3/6" PREMOLDED 112" R. ROADWAY v r� SEE RAISED EDGE I LTYPICILL UNDER �� OMRYMY.IEOUNEo -� o _ I E.PANSOUJOSR(tt0 I� SA DISPERSAL TRENCH NECESSARY JOINT FILLER 1 CEMENT CONCRETE SIDEWALK DETAIL -THIS SHE CRUSHED SURFACING TOP COURSE(CSTC) ALL CUT SIDEWALK OMPACT TO 95% MODIFIED PROCTOR WITH RAISED EDGE ENGINES R TYPIC L UN WANED BY SLOPES(� GUTTE &SIDE ALKCSTC UALL NCUR6, rloN,,, tl2' IN) R. (TYP.) GUTTER dSIDEWALK CSTC UNDER_.PEDESTRIAN ;s ceraErn 1SEE KM WAN R] COE.- I�� EW._62"x2" P NOTCHED GRADE BOARD,IF NOTCHES, 18" O.C. TYPE i CATCH BASIN (CB)WITH SOLID COVER CURB m �� 1 CURB d GUTTER TO BE 6THICKNESS OR FOR CURB DLTAllS `��- 1.5% MATCH EXISTING ROADWAY CRUSHED ROCK _ -^ - - - - G /J SOLID COVER T - AT SIDEWALK RAMPS AND LANDINGS SEE STD PLAN 101 14� BASE, WHICHEVER IS GREATER (TYP. FOR 0 A T 4NkTtfP •• •• •.• .• 1•f ALL CURB& GUTTER). -_-1 LI 7I =° I ,1 ` FACE OF ADJACENT CURB CEMENT CONCRETE - FINISHED GRADE r pN) BELav ° •• 1 TOP OF CONCRETE SURFACE r-o SIDEWALK 1.EaKOEas I J ul of „- - I� I� -1 Ip rD - f - 50' MAX. ❑ i �` �`" TRAFFIC CURB AND GUTTER _s1n"- 'I SEE DEPRESSED CURB DETAIL THIS SHEET ADJACENT TO CURB ,.-0 ,.-0 MIN 12-(IN) R. (TYP.) RW DING F o @ILL I ' � III ,� � L INFLUENT PIPE (MAX DESIGN FLOW <0.5 CFS PER TRENCH) _T 1 FOR CURB DETALS W {I/L it 1:24 FACE OF ADJACENT CURB 2.0% b 1.5% _ SEE STD PUW 101 �- •• ...... W �e \ 1 TOP OF L - 6 tit"-- FLUSH WITH GUTTER 1" 1!2' R. ROADWAY PAN AT SIDEWALK T 5t, • • - BRIDGE OR PEDESTRIAN 5�ad� `�'^Y� N '�f�"A S NT' '' - - -- • r "II "miEMER1cw GREiE JC'E�II CAPPED CLEANOUT WYE FROM PIPE II RAMP ENTRANCE 1 - 1.12 1.24 1 BARRIER-SEEPALI FOR CURB DETAILS ADJACENT SIDEWALK SEE CURBDSTO TAILS FlLL SLOPES) CONTRACT PLANS �---WALL OR BARRIER µ•, ra;s CWIYTMGTNN JONr mT.l: ri•-e ��� _ '�� \r`1'�J S ��tr�amWAN1o>t',� PLANVIEW'o 'I A� FLOW TO OTHER BRANCHING CB'S END CAP OR PLUG AS NECESSARY TOP OF tD 1/2'R. ROADWAY 1 DEPRESSED CURB SECTION � I _ / 12• (IN) R. (TYP ) I ts% SIDEWALK FLUSH •,1 M FRL VERTICAL WALL- r' ,�� r� '3-- • , . SEE DETAIL LNP o c _ L �VM6a 1,.I JI- --'rrti ew seE NotE�tiTry]0 IIIIr 1-FlI �I..."� -'- l = �� PLAN 2"xi2 GRADE BOARD, SEE NOTE 6 EXPOSED ROCK, DO NOT FILL AT RESIDENTIAL DRIVEWAYS ONLY. T FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 p . ►' 3ra Joil)vpT F1uE�Eo '� -I ;-____ I . L: •.. .dke_ GALVANIZED BOLT TYP. ( ) SEE V - 6" ADJACENT TO CURB AND RAILING OR WALL ' s MN � - u- �� 15 /NOTE 5 DEPRESSED CURB SECTION FACE OF CURB pRB. EMOLDEo JOINT FILLER FOR SIDE BUFFCR STRIP c TREATMENT SIDEWALK SIDEWALK ADJACENT TO WALL DETAIL 1'JRI pr \ cLNE 'c 4 Q ExPA1 fJpN 1pWtlTw 119 M��rE hl 59F tix t-,+SEE sto �,AN tOT - � o -'- , "'^'" F II EE °Py S `� 15°I° .KES �'� 2" (TYP.) 612' AT SIDEWALK RAMPS 61In 1" 12' R. 3/8" 1" R' SIDEWALK sEfS CTjORNES (SEE NOTE IO) 12'(IN)R. 1 [rrP_) FOR CURB DETAILS L5% 15%MIN._ SEE STD PLAN 101 .. . . ;;» • • ' ' ' \ GROOMED FINISH ,-.DrrEnEr+cE r+srovE r.w .. j:,, _ J\. J V -- L o o rfl �' OtaVEWA sw - nwE tsLarE a�q•Mit01AODEMTiio tss !�. �� 'rs`"�I st 7.__ _ .. -� L e'- e_ S / �_i v n SECTION B i '.._ 0 8 , ��-- /� � 2" GRADE BOARD NOTCHE ( ) 18 O.C. JG CJ •, / S TYP. - WRAP TRENCH SIDES WITH 12" MIN. ) GEOTEXTILE LEAVE TOP AND ( NOTCH DETAIL FACE OF ADJACENT CURB 1 1 TOP °�� OR du7CH IX1snNc r ,0� 4•WIDE,SMOOTM - ORNEWAY W RELATIVE } , �� NSAC i E SLOPEISLOPE RAUU �� /� - -- 5N(YNl+ExAlcEMTED � - , q 36" MAX O _ . `, BOTTOM EXPOSED), SEE NOTE 7 ROADWAY -- W • • . p 6 •3� • GUTTER SURFACE (lo p. TO .• - o -L S' TROWELED PERIMETER FINISHED GRADE 1• (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING -FLUSH IF PAVED.- • \ J�,I F_ �• ti 6" MIN. PERFORATED PIPE LAID FLAT/LEVEL • ,p PREMOLDED fQ!J" CEMENT CONCRETE CURB \(CURB AND GUTTER SHOWN)oADJACENT,TO BUFFER STRIP FOR CURB DETAILS "SEE STD PLAN 101 � � ' '� e �- :\- ` 3l4" -1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5) JOINT FILLER 1 E FULL -DEPTH 81/4' `% \� � V '�� _ 6" MIN. EXPANSION JOINT 1" R. / CEMENT CONCRETE / TRAFFIC CURB NOTES ��� - 1. Four feet of the sidewalk width shall , be the minimum pedestrian j IINSIIDDEWALKOf1ONLYNT •Ta'2 ro •• teaw*aa1,-J I��IsSUPPORT IIII a POST, SEE NOTE 6 SECTION A �! accessible route (PAR) free of vertical • •' and horizontal obstructions. Gratings, •'► "•_• R CEMENT w oECw�AIx ro•+(xnnc •'• FULL -DEPTH EXPANSION JOINT IN BOTH Access Covers, Junction Boxes, \ - _ T _ \ ,, �. ' E-1. STD PW410/7�Fi NOTES' ' DEPRESSED CURB DETAIL Cable Vaults, Pull Box84 and other CURB AND SIDEWALK (SEE sto FUN tD1.1) ` `ro 7 1. THIS TRENCH SHALL BE CONSTRUCTED SO AS TO PREVENT POINT DISCHARGE AND/OR EROSION. AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS the sidewalk Fly ffi9• C CONTRACTION JOINT appurtenances with must o flush with auRace, and match - surface, 'f grade of the sidewalk. JOINT AND FINISH ��- �.-�-� _ J' - ` 2. TRENCHES MAY BE PLACED NO CLOSER THAN 50 FEET TO ONE ANOTHER, 10 FEET MINIMUM TO ANY BUILDING DETAIL - Y� n 'iu (100 FEET ALONG FLOWLINE). 2. Monolithic Cement Concrete Curb and • `� O �'' � 3. TRENCH AND GRADE BOARD MUST BE LEVEL. ALIGN TO FOLLOW CONTOURS OF SITE. GENERAL NOTES: Sidewalk IS not ••� '•• . permitted in new For other referenced NOTES see i'• p , When TYPE R18� ISOMETRIC VIEW 1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. construction. replacement work STD PLAN 104.2. necessitates a Monolithic Cement PREMOLDE Concrete Curb build per WSDOT (RESIDENTWGcW17H BUFFER) _ _ l I' pp 4. SUPPORT POST SPACING AS REQUIRED BY SOIL CONDITIONS TO ENSURE GRADE BOARD REMAINS LEVEL. 2. Expansion joint shall be full depth, 3/B" (inJ premolded joint filler. Standard Plan F-30.10-03. Paved surfaces must comply with JOINT FILTER For NOTES STD PLAN 104.2'.I 5. 15% MAX UNLESS OTHERWISE EVALUATED AND APPROVED, SEE SECTION C.2.1.1. 3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2 STD PLAN 102.1 as applicable. E FULL -DEPTH 3. Concrete to be 4,000 PSI. 6. GRADE BOARD AND SUPPORT POST TO BE UNTREATED CEDAR OR RECYCLED PLASTIC. SPACE SUPPORT POSTS EXPANSION JOINT _ _ EVERY 10 FEET MINIMUM. • PUBLIC WORKS � DEPARTMENT CEMENT CONCRETE CURBS STD. PLAN - 101 • PUBLIC WORKS DEPARTMENT CEMENT CONCRETE SIDEWALK STD PLAN - 102 1 O PUBLIC WORKS � � �, DEPARTMENT CEMENT CONCRETE DRIVEWAY RIB STD. PLAN - 104.3 7. GEOTEXTILE TO BE NON -WOVEN TYPE FOR SEPARATION PER WSDOT 9-33.2(1). UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NITS) �T , PEpitO, 'P ��T , F F El QED / `�®Alsll. PUBLIC WORKS 50-FOOT DISPERSION TRENCH WITH STD. PLAN - 224.00 De y 10 % ENTRANCE -TYPE /'r` 8/13/20 0 8 `>�� DEPARTMENT NOTCHED BOARD artin Pastucha zGeege2lmmerman;hWk,WortAdTdnls_trator;� y�yvy�y p DATE �I CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS PURPOSE THE PURPOSE OF THIS CODE SECTION IS TO ESTABLISH GUIDELINES FOR THE RESTORATION OF CITY STREETS DISTURBED BY INSTALLATION OF UTILITIES AND OTHER CONSTRUCTION ACTIVITIES. ANY PUBLIC OR PRIVATE UTILITIES, GENERAL CONTRACTORS, OR OTHERS PERMITTED TO WORK IN THE b PUBLIC RIGHT-OF-WAY WILL ADHERE TO THE PROCEDURES SET FORTH IN THIS POLICY. DEFINITION ENGINEER: THE TERM "ENGINEER" SHALL DENOTE THE CITY PROJECT MANAGER, INSPECTOR AND/OR PLAN REVIEWER, OR THEIR DESIGNATED REPRESENTATIVE. ADDI IP`ATIPIKI THE FOLLOWING STANDARDS IN THIS SECTION SHALL BE FOLLOWED WHEN DOING TRENCH OR EXCAVATION WORK WITHIN THE PAVED PORTION OF ANY CITY OF RENTON RIGHT-OF-WAY. MODIFICATIONS OR EXEMPTIONS TO THESE STANDARDS MAY BE AUTHORIZED BY THE COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATOR OR AUTHORIZED REPRESENTATIVE UPON WRITTEN REQUEST BY THE PERMITTEE, THE PERMITTEE'S CONTRACTOR OR ENGINEER, AND DEMONSTRATION OF AN EQUIVALENT ALTERNATIVE. HOURS OF OPERATIONS HOURS FOR WORK WITHIN THE ROADWAY FOR ASPHALT OVERLAYS OR TRENCH RESTORATION SHALL BE AS DIRECTED BY THE TRAFFIC CONTROL PLAN REQUIREMENTS AND THE TRAFFIC OPERATIONS C. ENGINEER. INSPECTION THE ENGINEER MAY DETERMINE IN THE FIELD THAT A FULL STREET -WIDTH EDGE -OF -PAVEMENT TO EDGE -OF -PAVEMENT) OVERLAY IS REQUIRED DUE TO CHANGES IN THE PERMIT CONDITIONS SUCH AS, BUT NOT LIMITED TO THE FOLLOWING: 1. THERE HAS BEEN DAMAGE TO THE EXISTING ASPHALT SURFACE DUE TO THE CONTRACTOR'S EQUIPMENT. 2. THE TRENCH WIDTH WAS INCREASED SIGNIFICANTLY OR THE EXISTING PAVEMENT IS 4. UNDERMINED OR DAMAGED. 3. ANY OTHER CONSTRUCTION RELATED ACTIVITIES THAT REQUIRE ADDITIONAL PAVEMENT RESTORATION. CITY OF RENTON STANDARDS ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD AND SUPPLEMENTAL SPECIFICATIONS(CURRENT ADOPTED VERSION) EXCEPT WHERE OTHERWISE NOTED IN THESE STANDARDS. MATERIALS AND WORKMANSHIP ARE REQUIRED TO BE IN CONFORMANCE WITH STANDARDS FOR THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION PREPARED BY THE WASHINGTON STATE CHAPTER OF THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA) AND THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION (WSDOTP AND SHALL COMPLY WITH THE CURRENT EDITION, AS MODIFIED BY THE CITY OF RENTON SUPPPLEM NTAL 5 SPECIFICATIONS. 1. AN ASPHALT PAVER SHALL BE USED IN ACCORDANCE WITH SECTION 5-04.3(3) OF STANDARD a. SPECIFICATIONS. A "LAYTON BOX" OR EQUAL MAY BE USED IN PLACE OF THE POWER -PROPELLED PAVER. ROLLERS SHALL BE USED IN ACCORDANCE WITH SECTION 5-04.3(4) OF THE STANDARD b. SPECIFICATIONS. "PLATE COMPACTORS" AND "JUMPING JACKS" SHALL NOT BE USED IN LIEU OF ROLLERS. 2. TRENCH BACKFILL AND RESURFACING SHALL BE AS SHOWN IN THE CITY OF RENTON STANDARD C. DETAILS, UNLESS MODIFIED BY THE CITY PERMIT. SURFACING DEPTHS SHOWN IN THE STANDARD DETAILS ARE MINIMUMS AND MAY BE INCREASED BY THE ENGINEER TO MEET TRAFFIC LOADS OR SITE CONDITIONS. 3. REQUIREMENT FOR PATCHING, OVERLAY, AND OVERLAY WIDTHS: a. ALL TRENCH AND PAVEMENT CUTS SHALL BE MADE BY SAWCUT OR BY GRINDING. SAWCUTS OR GRINDING SHALL BE A MINIMUM OF ONE FOOT (1') OUTSIDE THE TRENCH WIDTH. THE TOP TWO INCHES (2") OF ASPHALT SHALL BE GROUND DOWN TO A MINIMUM DISTANCE OF ONE FOOT (1') BEYOND THE e. ACTUAL OUTSIDE EDGES OF THE TRENCH AND SHALL BE REPLACED WITH TWO INCHES (2") OF CLASS B ASPHALT, PER CITY OF RENTON STANDARD PLANS. AT THE DISCRETION OF THE ENGINEER, A FULL STREET WIDTH OVERLAY MAY BE REQUIRED. LANE -WIDTH OR A FULL STREET -WIDTH OVERLAY WILL BE DETERMINED BASED UPON THE LOCATION AND LENGTH OF THE PROPOSED TRENCH WITHIN THE ROADWAY CROSS-SECTION. CHANGES IN FIELD CONDITIONS MAY WARRANT IMPLEMENTATION OF ADDITIONAL OVERLAY REQUIREMENTS. a. TRENCHES (ROAD CROSSINGS): f. (1) THE MINIMUM WIDTH OF A TRANSVERSE PATCH (ROAD CROSSING) SHALL BE SIX AND ONE-HALF FEET (6.5'). SEE CITY OF RENTON STANDARD PLANS. (2) ANY AFFECTED LANE WILL BE GROUND DOWN TWO INCHES (2") AND PAVED FOR THE ENTIRE J. WIDTH OF THE LANE. (3) THE PATCH SHALL BE A MINIMUM OF ONE FOOT (1') BEYOND THE EXCAVATION AND PATCH LENGTH SHALL BE A MINIMUM OF AN ENTIRE TRAVELED LANE. (4) IF THE OUTSIDE OF THE TRENCHING IS WITHIN THREE FEET (T) OF ANY ADJACENT LANE LINE, THE ENTIRE ADJACENT TRAVELED LANE AFFECTED WILL BE REPAVED. (5) NOT AREA INCLUDING AND ET (6.5') TOTAL FORTHEENTIRE WIDTH AN FOT OEACH SIDE TTRENCH LESS THAN SIX AND 0 EHA F OF THE AFFECTED TRAVELED LANES WILL BE GROUND DOWN TO A DEPTH OF TWO INCHES (2"). A TWO-INCH (T) OVERLAY OF CLASS B ASPHALT WILL BE APPLIED PER CITY STANDARDS. TRENCHES RUNNING PARALLEL WITH THE STREET: (1) THE MINIMUM WIDTH OF A LONGITUDINAL PATCH SHALL BE FOUR AND ONE-HALF FEET (45). SEE CITY OF RENTON STANDARD PLANS. (2) IF THE TRENCHING IS WITHIN A SINGLE TRAVELED LANE, AN ENTIRE LANE -WIDTH OVERLAY WILL BE REQUIRED. (3) IF THE OUTSIDE OF THE TRENCHING IS WITHIN THREE FEET (T) OF ANY ADJACENT LANE LINE, THE ENTIRE ADJACENT TRAVELED LAND AFFECTED WILL BE OVERLAID. (4) IF THE TRENCHING IS GREATER THAN OR EQUAL TO 30% OF LANE PER BLOCK (660 FOOT MAXIMUM BLOCK LENGTH), OR IF THE TOTAL PATCHES EXCEED 12 PER BLOCK, THEN THE LANES AFFECTED WILL BE OVERLAID. MINIMUM OVERLAY SHALL INCLUDE ALL PATCHES WITHIN THE BLOCK SECTION. (5) THE ENTIRE TRAVELED LANE WIDTH FOR THE LENGTH OF THE TRENCH AND AN ADDITIONAL TEN FEET (10') AT EACH END OF THE TRENCH WILL BE GROUND DOWN TO A DEPTH INCHES (2"). A TWO-INCH (2") OVERLAY OF CLASS B WILL BE APPLIED PER CITY STANDARDS. POTHOLING: POTHOLING SHALL MEET THE SAME REQUIREMENTS AS TRENCHING AND PAVEMENT RESTORATION. POTHOLING SHALL BE A MINIMUM OF ONE FOOT (V) BEYOND THE EXCAVATION. ALL AFFECTED LANES WILL BE GROUND DOWN TO A DEPTH OF TWO INCHES (T) AND PAVED NOT LESS THAN SIX AND ONE HALF FEET (65) WIDE FOR THE ENTIRE WIDTH OF THE LANE. POTHOLES GREATER THAN FIVE FEET (5) IN LENGTH, WIDTH OR DIAMETER SHALL BE RESTORED TO TRENCH RESTORATION STANDARDS. IN ALL CASES POTHOLES SHALL BE REPAIRED PER RENTON STANDARD PLANS. RESTORATION REQUIREMENTS UTILIZING VACTOR EQUIPMENT WILL BE DETERMINED BY THE ENGINEER. PAVEMENT REMOVAL IN LIEU OF GRINDING: THE CONTRACTOR IN ALL CASES CAN REMOVE THE PAVEMENT IN THE REPLACEMENT AREA INSTEAD OF GRINDING OUT THE SPECIFIED TWO INCHES (2") OF ASPHALT. FULL PAVEMENT REPLACEMENT TO MEET OR EXCEED THE EXISTING PAVEMENT DEPTH WILL BE REQUIRED FOR THE AREA OF PAVEMENT REMOVAL. PATCHING OF PERVIOUS CONCRETE SHALL FOLLOW AMERICAN CONCRETE INSTITUTE (ACI) 522.1-13. POROUS ASPHALT SHALL BE SPECIFIED ON A PROJECT -BY -PROJECT BASIS BY THE ENGINEER. PERMEABLE MATERIALS SHOULD BE REPLACED IN -KIND WHERE FEASIBLE. PATCHING POROUS ASPHALT WITH CONVENTIONAL ASPHALT IS ACCEPTABLE IF IT IS NO MORE THAN TEN PERCENT (10%) OF THE TOTAL FACILITY AREA OR DOES NOT IMPACT THE OVERALL FACILITY FUNCTION. APPROPRIATE PRECAUTIONS SHALL BE TAKEN DURING PAVEMENT REPAIR AND REPLACEMENT EFFORTS TO PREVENT CLOGGING OF ADJACENT SURFACES, TRENCH BACKFILL AND RESTORATION CONSTRUCTION REQUIREMENTS: TRENCH RESTORATION SHALL BE EITHER BY A PATCH OR OVERLAY METHOD, AS REQUIRED AND INDICATED ON CITY OF RENTON STANDARD PLANS. ALL TRENCH AND PAVEMENT CUTS, WHICH WILL NOT BE OVERLAID, SHALL BE MADE BY SAWCUT OR GRINDING. SAWCUTS SHALL BE A MINIMUM OF TWO FEET (2') OUTSIDE THE EXCAVATED TRENCH WIDTH. ALL TRENCHING WITHIN THE TOP FOUR FEET (4') SHALL BE BACKFILLED WITH CRUSHED SURFACING MATERIALS CONFORMING TO SECTION 4-04 OF THE STANDARD SPECIFICATIONS. ANY TRENCHING OVER FOUR FEET (4') IN DEPTH MAY USE MATERIALS APPROVED BY THE ENGINEER OR MATERIALS LAB FOR BACKFILLING BELOW THE FOUR -FOOT (4') DEPTH. IF THE EXISTING MATERIAL PR OTHER MATERIAL) IS DETERMINED BY THE ENGINEER TO BE SUITABLE FOR BACKFILL, TH CONTRACTOR MAY USE THE NATIVE MATERIAL EXCEPT THAT THE TOP SIX INCHES (6") SHALL BE CRUSHED SURFACING TOP COURSE MATERIAL. THE TRENCH SHALL BE COMPACTED TO A MINIMUM NINETY-FIVE PERCENT (95%) DENSITY, AS DESCRIBED IN SECTION 2- 03 OF THE STANDARD SPECIFICATIONS. IN THE TOP SIX FEET (6) OF ANY TRENCH, BACKFILL COMPACTION SHALL BE PERFORMED IN EIGHT (8) TO TWELVE -INCH (12") LIFTS. ANY TRENCH DEEPER THAN SIX FEET (6) MAY BE COMPACTED INTWENTY-FOUR INCH (24") LIFTS, UP TO THE TOP SIX-FOOT (6) ZONE. ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN NINETY-TWO PERCENT (92%) OF MAXIMUM DENSITY IN PERMEABLE PAVEMENT AREAS. ALL COMPACTION SHALL BE PERFORMED BY MECHANICAL METHODS. THE COMPACTION TESTS MAY BE PERFORMED IN FOUR -FOOT (4') VERTICAL INCREMENTS MAXIMUM. THE TEST RESULTS SHALL BE GIVEN TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO PAVING. THE NUMBER AND LOCATION OF TESTS REQUIRED SHALL BE DETERMINED BY THE ENGINEER. TEMPORARY RESTORATION OF TRENCHES FOR OVERNIGHT USE SHALL BE ACCOMPLISHED BY USING MC MIX (COLD MIX), ASPHALT TREATED BASE (ATB), OR STEEL PLATES, AS APPROVED BY THE ENGINEER. ATB USED FOR TEMPORARY RESTORATION MAY BE DUMPED DIRECTLY INTO THE TRENCH, BLADED OUT AND ROLLED. AFTER ROLLING, THE TRENCH MUST BE FILLED FLUSH WITH ASPHALT TO PROVIDE A SMOOTH RIDING SURFACE. IF THE TEMPORARY TRENCH RESTORATION DOES NOT HOLD UP, THE CONTRACTOR SHALL REPAIR THE PATCH WITHIN EIGHT HOURS OF BEING NOTIFIED OF THE PROBLEM BY THE CITY. THIS REQUIREMENT APPLIES 24 HOURS PER DAY, SEVEN DAYS PER WEEK. IN THE EVENT THAT THE CITY DETERMINES TO REPAIR THE TEMPORARY PATCH, THE CONTRACTOR SHALL REIMBURSE THE CITY IN AN AMOUNT THAT IS DOUBLE THE CITY'S COSTS IN REPAIRING THE PATCH, WITH THE SECOND HALF OF THE REIMBURSEMENT TO REPRESENT CITY OVERHEAD AND HIDDEN COSTS. e. ASPHALT CONCRETE CLASS E OR CLASS B SHALL BE PLACED TO THE COMPACTED DEPTH AS REQUIRED AND INDICATED ON CITY OF RENTON STANDARD PLANS OR AS DIRECTED BY THE ENGINEER. THE GRADE OF ASPHALT SHALL BE AR-4000W. THE MATERIALS SHALL BE MADE IN CONFORMANCE WITH SECTION 9-02.1(4) OF THE STANDARD SPECIFICATIONS. f. TACK COAT SHALL BE APPLIED TO THE EXISTING PAVEMENT AT EDGE OF SAW CUTS AND SHALL BE EMULSIFIED ASPHALT GRADE CSS-1, AS SPECIFIED IN SECTION 9-02.1(6) OF THE STANDARD SPECIFICATIONS. TACK SHALL BE APPLIED AS SPECIFIED IN SECTION 5-04 OF THE STANDARD SPECIFICATIONS. g. ASPHALT CONCRETE CLASS E OR CLASS B SHALL BE PLACED IN ACCORDANCE WITH SECTION 5-04 OF THE STANDARD SPECIFICATIONS; EXCEPT THOSE LONGITUDINAL JOINTS BETWEEN SUCCESSIVE LAYERS OF ASPHALT CONCRETE SHALL BE DISPLACED LATERALLY A MINIMUM OF TWELVE INCHES (12"), UNLESS OTHERWISE APPROVED BY THE ENGINEER. FINE AND COARSE AGGREGATE SHALL BE IN ACCORDANCE WITH SECTION 9-03.8 OF THE STANDARD SPECIFICATIONS.ALL STREET SURFACES, WALKS OR DRIVEWAYS WITHIN THE STREET TRENCHING AREAS SHALL BE FEATHERED AND SHIMMED TO AN EXTENT THAT PROVIDES A SMOOTH -RIDING CONNECTION AND EXPEDITIOUS DRAINAGE FLOW FOR THE NEWLY PAVED SURFACE. FEATHERING AND SHIMMING SHALL NOT DECREASE THE MINIMUM VERTICAL CURB DEPTH BELOW FOUR INCHES (4") FOR STORM WATER FLOW. THE ENGINEER MAY REQUIRE ADDITIONAL GRINDING TO INCREASE THE CURB DEPTH AVAILABLE FOR STORM WATER FLOW IN AREAS THAT ARE INADEQUATE. SHIMMING AND FEATHERING AS REQUIRED BY THE ENGINEER SHALL BE ACCOMPLISHED BY RAKING OUT THE OVERSIZED AGGREGATES FROM THE CLASS B MIX AS APPROPRIATE. SURFACE SMOOTHNESS SHALL BE PER SECTION 5-04.3(13) OF THE STANDARD SPECIFICATIONS. THE PAVING SHALL BE CORRECTED BY REMOVAL AND REPAVING OF THE TRENCH ONLY. ASPHALT PATCH DEPTHS WILL VARY BASED UPON THE STREETS BEING TRENCHED. THE ACTUAL DEPTHS OF ASPHALT AND THE WORK TO BE PERFORMED SHALL BE AS REQUIRED AND INDICATED ON CITY OF RENTON STANDARD PLANS. COMPACTION OF ALL LIFTS OF ASPHALT SHALL BE A MINIMUM NINETY-TWO PERCENT (92%) OF DENSITY AS DETERMINED BY WSDOT TEST METHOD 705. THE NUMBER OF TESTS REQUIRED SHALL BE DETERMINED BY THE ENGINEER. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING LAB WITH THE RESULTS BEING SUPPLIED TO THE ENGINEER. TESTING IS NOT INTENDED TO RELIEVE THE CONTRACTOR FROM ANY LIABILITY FOR THE TRENCH RESTORATION. IT IS INTENDED TO SHOW THE INSPECTOR, AND THE CITY, THAT THE RESTORATION MEETS THESE SPECIFICATIONS. h. ALL JOINTS, EXCEPT THOSE ASSOCIATED WITH PERMEABLE PAVEMENT, SHALL BE SEALED USING PAVING ASPHALT AR4000W. I. WHEN TRENCHING WITHIN THE UNPAVED ROADWAY SHOULDER(S), THE SHOULDER SHALL BE RESTORED TO ITS ORIGINAL CONDITION, OR BETTER. j. THE FINAL PATCH SHALL BE COMPLETED AS SOON AS POSSIBLE AND SHALL NOT EXCEED FIFTEEN 15) WORKING DAYS AFTER FIRST OPENING THE TRENCH. THIS TIME FRAME MAY BE ADJUSTED IF DELAYS ARE DUE TO INCLEMENT PAVING WEATHER OR OTHER ADVERSE CONDITIONS THAT MAY EXIST. HOWEVER, DELAYING OF FINAL PATCH OR OVERLAY WORK IS SUBJECT TO THE ENGINEER'S APPROVAL. THE ENGINEER MAY DEEM IT NECESSARY TO COMPLETE THE WORK WITHIN THE FIFTEEN (15) WORKING DAY TIME FRAME AND NOT ALLOW ANY TIME EXTENSION. SHOULD THIS OCCU , THE CONTRACTOR SHALL PERFORM THE NECESSARY WORK, AS DIRECTED BY THE ENGINEER. k. A CITY OF RENTON TEMPORARY TRAFFIC CONTROL PLAN (FROM RENTON TRANSPORTATION ENGINEERING) SHALL BE SUBMITTED AND APPROVED BY THE ENGINEER A MINIMUM OF THREE (3) WORKING DAYS PRIOR TO COMMENCEMENT OF WORK. 6. REMOVAL OF UTILITY LOCATE MARKINGS FROM SIDEWALKS REQUIRED: THE PERMITTEE WILL BE REQUIRED TO REMOVE UTILITY LOCATE MARKS ON SIDEWALKS ONLY WITHIN THE CENTER DOWNTOWN ZONE. THE PERMITTEE SHALL REMOVE THE UTILITY LOCATE MARKS WITHIN 14 DAYS OF JOB COMPLETION. NO. REVISION J L� I Or LANDSCAPE STRIP 0.5' 5 IDEWALK �� SURVEYED: DESIGNED: DRAWN: CHECKED: BY I DATE I APPR I APPROVED: 1. 5 0//D _ ,'.r-1 0.5' CURB SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 30' SAWCUT 16' TRAVELLANE VARIES 6" CRUSHED SURFACING BASE COURSE (CSBC) 4" COMMERCIAL HMA CONCRETE CURB AND GUTTER PER CITY OF RENTON STANDARD PLAN 101, SEE SHEET C3.1 R-414106 1 /7/2021 VERnCAL- NAVD 19M HORIZONTAL- NAD 1983/1991 DATU M T± 30' VARIES T- EX. PAVEMENT q 160TH AVENUE SE ROADWAY SECTION 'A' C3,0 NITS \URVICES 4715142nd PI. SW #B, Edmonds, WA 98026 ph 206.890.8291 uR CITY OF RENTON Planning/Building/Public Works Dept. 1. UTILITY CORRIDOR REQ'D FOR TELEPHONE PEDESTALS, FIRE HYDRANTS, UTILITY POLES, LUMINAIRES, SIGNS, ETC. 2. PAVEMENT DESIGN BY CURRENT WASHINGTON STATE LICENSED CIVIL ENGINEER AND AS APPROVED BY THE CITY ENGINEER. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Nathan Janders 02/19/2021 ROPPE SFR ROAD DETAILS 901 B co W DATE: 07-22-2020 0- 0- O FIELDBOOK: PAGE: DRAWING NO: C3.1 SHEET: 6 OF: 9 T T I 6 I W I- DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT, THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION(APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTSFPUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN'DOESNOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY, REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND1 MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION. AREAS_, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 51NSIDE AND OUTSIDE. 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, 204.30, 204.40, AND 204.50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16, LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.00 .®� PUBLIC WORKS SURFACE WATER STANDARD PLAN +?60I�dby: ` DEPARTMENT NOTES (1 OF 2)vkuv artin Pastucha8/13/2020 11T96LaS44®D... DATE DocuSign ErtVel_* ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 28" MAX. 15' MAX. FOR MAINTENANCE '0" RING - 12" 6" 4" MIN. 16" MAX. 48", 54", 60", 72", 84", 96", 120" OR 144" STEPS OR LADDER, 12- (TYP.) T 1" MIN. 24" r MAX. MIN. I 12.5" I 12" MAX. CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) - MORTAR, (TYP.), SEE NOTE 5 FLAT SLAB TOP SEE NOTE 6, TYP. REINFORCING STEEL, (TYP.) GRAVEL BACKFILL FO",lPE'Z'ONE ;A 2'• BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) s" SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4. 6" 36" 81, 54" 4.5" 8" 42" 81, 60" 5" 8" 48" 8" 72" 6" 8" 1 60" 1 12" 84" - 8" 12" 72" 12" 96" - 8" 12" 84" 12" 120" 2 12" 96" 12" 144" 12" 12" 108" 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP' SOLID WALL PVC' PROFILE WALL PVC' 48" 24" 30" 24" 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48„ 48" 84" 54" 60" 54" 48" 48" 96" 60" 72" 1 601, L48" 48" 120" 66" 1 84" 1 60" CI)_B" 4W 144" 78" 1 96" 1 60" �4 'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 'STD. SPEC. 9-05.12(1) a STD. SPEC. 9-05.12(2) UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 201.00 o PUBLIC WORKS CATCH BASIN TYPE 2 PR DEPARTMENT GAZ 9/28/2018 1 - P„nrm works nemm�a.amr DATE SW 1/4 OF THE SE 1/4, SEC. 14, T 23N,, R 05E, W.M. DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY - PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE'. APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4-8INCH ROCK / 40 - 70% PASSING; • 2-4INCH ROCK 130-40%PASSING: AND • LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20, THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED_' TO THE CITY PRIOR TO CONSTRUCTION. 22, ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY, CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM. SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS or STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM 31. CONSTRUCTED PERMEABLE PAVEMENT SHALLBE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE"OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 3/4" DIA. BAR FRAME -- --------------- I I _ A I I I I 4" CLEAR SPACING INSERT ALUMINUM TRASH RACK INTO BEVELED PIPE END PLAN VIEW GROUND SURFACE INSERT ALUMINUM TRASH RACK INTO BEVELED PIPE END 6" CLEAR FROM DEBRIS BARRIER TO FINISHED GRADE JI FLOW, (J 4" CLEAR SPACING 45° I SECTION A GROUND SURFACE 3" MIN. 6" CLEAR FROM DEBRIS BARRIER TO FINISHED GRADE TO FIT INNER ROLLED SMOOTH DIAMETER OF PIPE I 16 GA. ALUMINUM PLATE NOTES: 4" CLEAR SPACING 1/4"x2" F.B. ANCHOR STRAPS. FASTEN WITH 1/2" GALVANIZED OR NON -CORROSIVE BOLTS AND NUTS (TYP., 4 PLACES) 1. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 2. CONTRACTOR TO VERIFY DIMENSIONS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.10 PUBLIC WORKS SURFACE WATER STANDARD PLAN] bi46M§Bed by: PUBLIC WORKS I 8:4 DEPARTMENT /13/2020 8:48 DEPARTMENT DEBRIS BARRIER NOTES (2 OF 2) Aartin Pastuch v4sipaRO.azF/]ONBdiODI DATE :45 OA POST CONSTRUCTION SOIL AMMENDMENT OPTION 2 (AMEND SOIL IN PLACE) THE SIMPLEST WAY TO RESTORE SOIL QUALITY WHERE THE SOIL HAS BEEN COMPACTED OR THE FOREST DUFF OR TOPSOIL REMOVED IS TO ROTOTILL COMPOST INTO THE EXISTING SOIL. -APPLY A LAYER OF COMPOST TO EXISTING SOIL AT THE PRE -APPROVED AMENDMENT RATE OF 1.75 INCHES FOR TURF AREAS, OR 3 INCHES FOR PLANTING BEDS. USE THE ONLINE COMPOST CALCULATOR AT HTTP://YOUR.KINGCOUNTY.GOV/SOLIDWASTE/COMPOST-CALCULATOR.HTM TO CALCULATE THE AMOUNT OF COMPOST NEEDED. RETAIN COPIES OF RECEIPTS FOR COMPOST DELIVERED TO THE SITE, AS THEY WILL BE USED DURING INSPECTION TO VERIFY THE SOIL REQUIREMENTS HAVE BEEN MET. •ROTOTILL COMPOST INTO SOIL TO A DEPTH OF AT LEAST 8 INCHES. NOTE THAT TILLING TO THIS DEPTH WILL REQUIRE REPEATED PASSES WITH A LARGE MACHINE, SUCH AS A TRACTOR MOUNTED OR HEAVY REAR TINE ROTOTILLER. NO. I REVISION #NDS 121012"x12" GRATE, GREY #NDS 121 OS 12"A2" GRATE, SAND #NDS 1211 12"x12" GRATE, BLACK #NDS 1212 12"x12" GRATE, GREEN 12"x12" GRATE FITS ALL CATCH BASINS, EXTENSIONS & ADAPTERS PROVIDE: #NDS 1216 6" EXTENSION #NDS 1218 12" EXTENSION AS REQUIRED. #NDS 121312N12" CATCHBASIN, SINGLE OUTLET #NDS 1214 12N12" CATCH BASIN, DOUBLE OUTLET 6" SD COUPLING SIZE, SINGLE OUTLET ACCOMODATES NDS 1212, 1211 OR 1210 12"x12" GRATE AREA -14" WITH 11" SQUARE BOTTOM. 12-4" SQUARE BOTTOM WITH 3" AREA BELOW OUTLET ALLOWS 363 CUBIC INCHES OF SUMP AREA. ADAPTABLE UP TO 8" PIPE OR DOWN TO 3" OR 4" PIPE. 6" SD COUPLING SIZE, DOUBLE OUTLET ACCOMODATES NDS 1212, 1211 OR 1210. 12"x12" GRATE AREA -14" HIGH WITH 11" SQUARE BOTTOM. 12-4" SQUARE TOP WITH 3" AREA BELOW OUTLET ALLOWS 363 CUBIC INCHES OF SUMP AREA. ADAPTABLE UP TO 8" PIPE OR DOWN TO 3" TO 4" PIPE USING ADAPTER #643. YARD DRAIN DETAIL NOT TO SCALE SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE AP P R APPROVED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 223.00 JPPROV D GAZ 9/28/2018 1 1 :45 Public works namininra�oDATE R-414107 1 /7/2021 VERTICAL NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM TOP OF CURB FLOW LINE EL. = 444.72 EX.ASPHALT C 0.5' 4.58' V GUTTER 1' TYP d a , a. Q. a'd a o a 04 4.108' ° a d as . 8. a' a a d' c d a da d' C a . a C A 8. CB-2 CONCRETE COLLAR NTS IN COMPLIANCE WITH CITY OF RENTON STANDARDS um DEVELOPMENT ENGINEERING EN61MEMN6 :0" Nathan Janders 02/19/2021 4715142nd PI. SW #B, Edmonds, WA 98026 ph 206.890.8291 CITY OF AR RENTON Planning/Building/Public Works Dept. DATE: 07-22-2020 R O P P E S F R FIELDBOOK: PAGE: DRAWING NO: STORM DETAILS C3.2 SHEET: OF 7 : 9 e LL w W 0- 10- iY GENERAL LANDSCAPE NOTES 1. Contractor is responsible for obtaining all necessary permits from the appropriate agency prior to commencing work. Contractor shall contact Line Locators (811) a min. of 48 hours prior to any digging or trenching. If there are any discrepancies with existing lines and landscaping, it is the contractor's responsibility to contact the landscape architect and request a site visit to address the conflicts. Contractor shall comply and conform to any and all local and state codes for work, schedules and any other project related requirements. 2. Contractor shall coordinate directly with the landscape architect for all landscape related issues, concerns, inspections and approvals. Contractor shall provide the landscape architect with a written request for a site visit to address any related items. 3. Scope of work shall include any and all specified and unspecified but related incidental work to achieve the design indicated on the landscape plans. All labor, materials, subcontractors, equipment, and related incidental items shall be supplied and installed to achieve a complete project, unless directed otherwise by the general contractor or landscape architect. 4. Contractor to verify all sub grades are set below required amendments to insure the finished grade will match what is intended by civil or drainage design. All sub grades and finished or final grades shall be graded to drain to the designed drainage system with positive drainage away from all structures. 5. Grade Preparation: a. Slopes used for grass plantings or turf shall be less than 3:1 or 33 percent. Otherwise plantings should not require mechanized mowing equipment. Soil Preparation. a. Where soils are compacted, planting beds should be deep tilled to a depth of at least 12 inches. Soils shall be enhanced through the addition of the following materials: bark and forestry by-products, organic matter such as composted yard waste, organics and other amendments as needed through a soils test. Where Pit Planting, see planting detail for planting ring sizes and depths. Scarify the edges of planting pits to encourage root expansion. b. On project sites where topsoil is limited or nonexistent, a minimum depth of 6 (six) inches of sandy loam topsoil should be tilled into the soil to a depth of 12 inches through all planting areas with compacted soils. c. For all newly planted areas, three cubic yards of composted organic matter per 1,000 square feet of landscape area should be added to a depth of four inches to the top of the soil and Tilled in. d. Seeded areas shall be fine graded and rolled. New Soil depths in lawn areas shall be 4 Inches. 2. Mulching of Newly Planted or Replanted Areas. a. Mulches must be applied to the following depths: a minimum 3 (three) inches over bare soil. b. Mulches must include organic materials, such as wood chips and shredded bark. c. Nonporous materials, such as plastic sheeting, shall not be used in any area of the landscape because of down -slope erosion and potential soil contamination from herbicide washing. d. Mulch should be applied regularly to and maintained in all planting areas to assist soils in retaining moisture, reducing weed growth, and minimizing erosion. 7. Contractor shall field layout all plant material and contact the landscape architect for a site visit to approve the layout. Any field modifications shall be done by the landscape architect prior to planting. 8. Contractor shall immediately notify the landscape architect of any poor drainage condition in landscape areas. No standing water shall be permitted in any landscape areas - either on the surface or below the topsoil. The landscape architect shall coordinate the drainage solution with the general contractor and civil engineer. Once the concerns have been remedied planting shall commence. 9. All groundcover to be planted in a triangular spacing formation, equal in all directions to the centers of the groundcovers in distances indicated in the legend. Contractor shall verify all quantities of groundcovers by area calculations and spacing requirements. 10. Landscaping is to be per plan. Plant substitutions due to availability or otherwise will be allowed only with landscape architect, owner and agency approval. Any substitutions will be with material of similar size, growth characteristics, and quality. 11. All trees must be staked as necessary so as to maintain material in a healthy, vigorous growing condition. 12. Landscaping shall be installed in a professional workmanlike manner that is consistent and accepted throughout the industry. All landscape and irrigation work shall be performed by experienced persons familiar with scope of project. 13. All landscape material and labor is to be guaranteed for a period of one full year from the time of completion. 14. When planting 'Balled and Burlapped' product, remove all burlap, string & wire from any B&B plant material, cut and remove jute strings. Gently place in tact Rootbal into planting pit. If rootball breaks or is not solid - the plant is unacceptable and shall be replaced. 15. Street trees shall have caliper size of at least 1 1/2" measure per American Association of Nurserymen Standards. 16. Street trees shall be high branching with canopy that starts at least 6' above finish grade. 17. All plant I.D. tags are to remain on the plant material until final inspection has been completed. Once approved all plant I.D. tags shall be removed and discarded appropriately. 18. Trees shall be cared for in accordance with the American National Standards Institute (ANSI) standard practices for trees, shrubs and other woody plant maintenance (ANSI 300) in order to allow them to reach there mature height and form. 19. Pruning of street trees shall be performed per the ANSI 300 standards so as to maintain the natural form of the tree, encourage vigorous growth to a mature spread and height, and avoid weakening the tree to create a hazard. Street trees shall not be topped pollarded, or otherwise pruned in a manner contrary to these goals, unless there is no practicable alternative that would preserve essential utility services. 20. Plant material selected is drought tolerant or native species. The project proponent shall be responsible for maintaining and watering all plant material throughout the first growing season and in times of drought. Temporary irrigation shall be provided via TREE GATOR BAGS attached to each tree. A temporary method for watering the planting areas shall consist of minimally a hose bib access to the area and drip hoses on a battery operated hose bib timer. For planting warranties from contractor to be ensured, contractor shall be responsible for watering the plant material and keeping the mulch ring weed free for the first growing season as part of the contract. It is recommended to install the landscaping in the Spring (February - April) or Fall (October - December)when dormant but before hard freeze. TEMPORARY IRRIGATION The project proponent shall ensure that a minimum of one (1) inch of water is supplied each week to the restoration area between May 1 and October 15 for a least the first two years following initial planting. The calculated amount of required water shall include both natural rainfall and temporary irrigation. PLANT LEGEND TREES SYMBOL QTY DESCRIPTION SIZE Cercis canadensis 'Forest Pansy'- Medium (1) 2" Cal. Min 02 Forest Pansy or sim. Eastern Red Bud Well Formed Hydroseed for Typical Lawn Areas SUNMARK NATIVE ECOTURF- OR EQUIV. Sunmark Seeds www.sunmarkseeds.com 0 Botanical Name Common Name /o by Weigh ht Festuca rubra Native Red Fescue 45% Bouteloua gracilis Blue Grama 25% Buchate dactyloides Buffalograss 20% Koeleria macrantha Prairie Junegrass 7% Trifolium fragiferum Strawberry Clover 3% 1 Ibs per 1,000 SF or 43.67 Ibs per acre Stree trees may be substituted with approved City of Renton Street tree list. CURRENT PLANNING" 9-+Ik aweihs 02/19/2021 4' CHAINLNK FENCE am GATE GARAGE UF,O I / / g n14" 'M 0 I 30' 30' 3 0 12,627 SF / Minumum Number of Trees = (Lot area = 5,000) x 2 I I 2.52 X 2 = 5 TREES REQUIRED Z II 5 EXISTING ON SITE + 2 NEW STREET TREES I I I N N (10 6' FOUND 1/2 REBARWOOD WOOD FENCE CAP CHAINLINK 0.4' SOUTH OFECALC� N88'18'09"W 165.04 - FENCE - POSITION ( J I I CHAINLINK FOUNTAIN 7.5 J 1011 - ¶ BseL JB/I �47 �- BORDER $Yrt(�_1 `rr 10" ° 1J++ 47 sHEo RD ; HYD OSE30' WOOD R FOOT BORDgggRRRE ROCK BRIDGE 1 4' a S RE WALL FENCE z + + i- � ro 1 + +++ HED- SPLIT NICE r I RAIL I 'L� II + + -ENCE I +$4 N I 1 a Aa;•+ + 25' S �/D+i•a+RIVEWA} L ++A+ z +++ly + NN+* / ++ 1 10" x3 iI1 ----- 1 - - - -I ++ ++ +++++ +++++ CARPORT PROPOSED + + + RR HOUSE APPROX. ♦+ TIILOCATION +E -CONC. BSEPTIC PAVERS TANK + 3 HIMNEY PER + + + II GATE I I HOUSE Ix #14005 � I II I I APPROX. 1 II LOCATION I I I OLD / 1 I I. I OIL 1 I i EXISTING 1 I GARAGE / G 1 I 1 I I \ (X) EQUIDISTAI)jfi'"\ DISTANCE (X) PER PLANT LEGEND NOTES: ALL GROUNDCOVER SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING AS SPECIFIED IN THE PLANT LEGEND. LOCATE GROUNDCOVER ONE-HALF OF SPECIFIED ON -CENTER SPACING FROM ANY CURB, SIDEWALK OR OTHER HARD SURFACE. CONIC. PAVERS t 6� ROCK--� STEPS - �6IIj GRASS WOOD Y PORCH mlm ° SECF d W/STAIRS �Tl 7TT�� � I i g - 2'x3' STEEL PLATE OVER CULVERT S88409"E 165.04 15'INGRESS/EGRESS AND UTILITY EASEMENT PER DEED NO. 8709020014 TANK COUNTY AS -BUILT 11'7 PORCH APPROX. LOCATION 20' OF DRAIN FIELD RD ++• + . d - 4 • + . a .°. • ♦ + .. d ♦ + ••• 14, • + • • ••+ :D +41�4+ cF / ° • i • +W / ••• +++ ° / BRICK � + +•+ ORDER �PL NTER •+++ sky GATE / U I so Cn Cn tn� II Q GO V (n I� � o N THREE I EXISTING 4 ASPHALT DRIVEWAY .k�, -° -�_f TO REMAIN T HH V) 7 N FOUND 1/2" REBAR W/ILLEGIBLE CAP 0.4' SOUTH OF CALC POSITION I cATv J W 0 I � = a 0 0 C cn RIM=438.97 IL IE=436.09(S) SMH CTR. C 9.52 I CTR. CHANNEL=428.2 0 0 1n I N GRAPHIC SCALE LANDSCAPE PLAN N 20 '° 20 a° ( IN FEET ) 1 inch = 20 ft. WHEN PLANTING ON STEEP SLOPE, -� MAINTAIN PLANT IN VERTICAL POSITION WITHIN PLANTING PIT. MAKE A RIM ON DOWNSLOPE SIDE OF 6" FROM BASE PLANT PIT TO RETAIN WATER, OF BRANCHING ` s I Y. J 3" MULCH ` ENSURE PROPER SUBBASE IIIIII I IIIII IIIII"' """'nlllllll EXISTS; CLEAR ALL CONCRETE AND OTHER - DEBRIS FROM PLANTERS 1.5III - PRIOR TO BACKFILLING _ AND PLANTING NOTES: 12" = III -III . 1. PLANTING BACKFILL: 1III-III. 50 % EXISTING SOIL, 50 % 1/4 MINUS COMPOST, MIXED THOROUGHLY 2. FOR MULCH TYPE SEE 2 X BALL DIA. LANDSCAPE NOTES. 3. IF B&B AND BURLAP IS GREEN IN COLOR. REMOVE COMPLETELY BEFORE INSTALLING PLANT. GROUNDCOVER PLANTING DETAIL No Scale DECIDUOUS TREE INTERLOCKING PLASTIC TREE TIES OR AGENCY APPROVED EQUAL (2) 2x2 OR 2" DIA. WOOD STAKES DRIVEN INTO SUBGRADE OR SIM. METHOD FORM SAUCER WITH CONTINUOUS RIM TOP SOIL OR AMENDED BASE, REFER TO LANDSCAPE NOTES FOR DEPTH WHEN B&B REMOVE ALL WIRE AND ROLL III. OFF TOP OF ROOTBALL LP I1 11= SCARIFY SIDES OF PIT, BACKFILL WITH SOIL MIXTURE INDICATED IN THE NOTES IN 9" LAYERS. WATER AND TAMP TO REMOVE AIR POCKETS DECIDUOUS TREE PLANTING & STAKING DETAIL No Scale .f r CB 54"0 RIM=443.46 IE(18"N)=439.86 °. IE(24"NW)=439.61 IE(30"S)=438.91 ea SSNN RN-"1.W ° CAR WMNE1- 'Q 4. FOUND 2" DISK W/PUNCH IN CONIC IN CASE DOWN 0.5' ® INTX. '60, AVE SE AND SE 140TH ST .A a. A° 'I N SE114077-1 ST. U0U Know what's below. Call before you dig. REMOVE ALL WIRE WRAP AND PLASTIC WRAP. REMOVE BURLAP FROM MULCH TO DEPTH TOP OF ROOT BALL SPECIFIED IN NOTES MULCH & TOPSOIL OR FORM CONTINUOUS AMENDED BASE, REFER TO RIM 'lllllllllllllllllllllll IIIIIII"" '.11 IIIII III�IIIIIIIIIIIIIII' LS NOTES FOR DEPTH WHEN B&B: REMOVE ALL WIRE AND ROLL BURLAP OFF OF TOP _ BACKFILL W/ BACKFILL OF ROOTBALL MIXTURE AS INDICATED _ NOTES: IN NOTE IN 9" LAYERS. 1 . PLANTING BACKFILL: WATER AND TAMP TO Q 50%EXISTING SOIL, 50% 1/4 MINUS REMOVE AIR POCKETS _ -III COMPOST, MIXED THOROUGHLY 2 X BALL DIA. 2. FOR MULCH TYPE SEE 10 LANDSCAPE NOTES. 3. IF B&B AND BURLAP IS GREEN IN COLOR. REMOVE COMPLETELY BEFORE INSTALLING PLANT. SHRUB PLANTING DETAIL N.T.S. ,4A Nature By Design Landscape Architecture 253.460.6067 1320 Alameda Avenue, Suite 3, Fimrest, WA 98466 www.naturebydesigninc.com 00 A a � Ocd LO 0 o � ao� � W ►n 00 O OC REVISIONS: DRAWING ISSUED FOR: AGENCY REVIEW DATE: JANUARY 11, 2021 PROJECT NO.: 2052 FILE NAME: 2052LSB X-REFS: DRAWN BY: KLO CHECKED BY: KLO PLOT SCALE: 1:1 DRAWING SCALES: 1:10 DRAWING CONTENTS LANDSCAPE PLANTING PLAN, NOTES & DETAILS DRAWING NO.: L 1 1 OF 1 901 (y) t' 1 0 0 0 UN V B