HomeMy WebLinkAboutPRE21-000144_Meeting SummaryPREAPPLICATION MEETING FOR Nicoli Short Plat 3930 Park Ave N PRE 21-000144 CITY OF RENTON Department of Community & Economic Development Planning Division May 13, 2020 Contact Information: Planner: Brittany Gillia, 425.430.7246, bgillia@rentonwa.gov Public Works Plan Reviewer: Jonathan Chavez, 425-430-7288, jchavez@rentonwa.gov Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org Building Department Reviewer: Rob Shuey, 425.430.7235, rshuey@rentonwa.gov Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects, and contractors who work on the project. You will need to submit a copy of this packet when you apply for land use and/or environmental permits. Pre-screening: When you have the project application ready for submittal, call and schedule an appointment with the project manager to have it pre-screened before formal submittal. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services Director, Department of Community & Economic Development Administrator, Public Works Administrator and City Council). M E M O R A N D U M DATE: April 28, 2021 TO: Brittany Gillia, Associate Planner FROM: Corey Thomas, Lead Plans Review Inspector SUBJECT: Nicoli Short Plat 1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. One existing hydrant appears to meet the minimum requirement. 2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is paid at building permit issuance. Credit is granted for the removal or retention of the one existing home. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Dead end access exceeding 150-feet require an approved fire apparatus turnaround. A hammerhead type turnaround would be acceptable. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: May 11, 2021 TO: Brittany Gillia, Planning FROM: Jonathan Chavez, Development Engineering SUBJECT: Nicoli Short Plat 3930 Park Avenue N PRE21-000144 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non- binding and may be subject to modification and/or concurrence by official city decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel 3342700532. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1. Water service is provided by the City of Renton. It is in the Kennydale 308 Pressure Zone. There is an existing 12-inch water main in Park Ave N that can deliver 3,400 gallons per minute. The approximate static water pressure is 83 psi at a ground elevation of 115’. 2. There is an existing ¾-inch domestic water service and ¾-inch water meter to the existing single family residence (3930 Park Ave N) on the subject property. Based on the review of project information submitted for the pre-application meeting, Renton Regional Fire Authority has determined that the preliminary fire flow demand for the proposed development is 1,000 gpm. The following developer’s installed water main improvements will be required to provide domestic and fire protection service to the development including but not limited to: 1. Extension of approximately 270 feet of 8-inch water main from the existing 12-inch water main in Park Avenue N to approximately 10 feet east of the west property line of proposed lot C. 2. A 15-foot utility easement will be required for the new water mains, hydrants, and water meters within the property. 3. Installation of additional fire hydrant as required by the Fire Authority, if the proposed residences on the new lots exceed 3,600 sq-ft. 4. Installation of a new 1-inch water service and meter to each lot of the short-plat including to the existing residence on lot A, connecting the new 8-inch water line within the access road. 5. The existing ¾-inch domestic water service shall be cut and capped at the main line. Nicoli Short Plat - PRE21-000144 May 11, 2021 Page 2 of 5 6. A conceptual utility plan will be required as part of the land use application for the subject development. 7. Civil plans for the water main improvements will be required and must be prepared by a Professional Engineer registered in the State of Washington. Please refer to City of Renton General Design and Construction Standards for Water Main Extensions as shown in Appendix J of the City’s 2012 Water System Plan. 8. Adequate separation between utilities is required. Minimum separation between water and non-potable water utilities is 10-feet horizontal and 1.5-feet vertical. 9. The development is subject to applicable water system development charges (SDC’s) and meter installation fees based on the number and size of the meters for domestic uses and for fire sprinkler use. The development is also subject to fees for water connections, cut and caps, and purity tests. Current fees can be found in the 2021 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. a. The SDC fee for water is based on the size of the new domestic water to serve the project. The 2021 water fees are $4,450.00 per 1-inch meter. b. Water service installation charges for each proposed domestic water service is applicable. Water Service installation fee is $2,875.00* per 1-inch service line. Fee is payable at permit issuance. c. Drop-in meter fee is $460.00* per 1-inch meter, $750.00 per 1-1/2-inch meter, and $950.00 per 2-inch meter. Meters larger than 2-inches are set by the contractor and a processing fee of $220 is required. Fee is payable at permit issuance. d. A credit for the water system redevelopment fee will be issued f or the existing water service to be cut can capped as part of the project. e. Final determination of applicable fees will be made after the water meter size has been determined. SDC fees are assessed and payable at permit issuance. SEWER 1. Sewer service is provided by the City of Renton. 2. There is existing 8-inch diameter sewer main on Park Avenue N. a. As-built: https://edocs.rentonwa.gov/Documents/DocView.aspx?id=291627&dbid=0&repo=Cityo fRenton&searchid=af2dd81d-8d07-4f48-8d8d-afd5119b2e66 3. A sewer main extension will be required to serve the proposed project. 4. A 15-foot utility easement will be required for the new sewer mains and manholes within the property. 5. The developer will need to show how they propose to serve the new development with sanitary sewer service to each of the units. 6. A separate side sewer will be required for each new lot. All new side sewers shall be a minimum of 6”. All side sewers shall flow by gravity to the main at a minimum slope of 2%. 7. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. Current fees can be found in the 2021 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. a. The 2021 Wastewater fees are $3,450.00 per 1-inch meter. SURFACE WATER Nicoli Short Plat - PRE21-000144 May 11, 2021 Page 3 of 5 1. A drainage report complying with the current Renton Surface Water Design Manual (RSWDM) will be required. Based on the City’s flow control map, the site falls within the City’s Peak Rate Flow Control Standard (Matching Existing Conditions). The site falls within the May Creek Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. All stormwater improvements as per the drainage review along with stormwater improvements in the frontage are required to be provided by the developer. 2. This site contains steep slopes (regulated). The topography slopes moderately from southeast to northwest. There is a conveyance system on Park Avenue N. 3. Storm drainage improvements along all public street frontages are required to conform to the City’s street and stormwater conveyance standards. Any new storm drain installed on or off -site shall be designed and sized in accordance with standards found in Chapter 4 of the 2017 RSWDM and shall account for the total upstream tributary area, assuming developed conditions for onsite tributary areas and existing conditions for any offsite tributary areas. 4. Maintenance access is required for any proposed stormwater tracts and shall be designed and installed in accordance with the City adopted SWDM. 5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide basic water quality treatment. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2017 RSWDM. A preliminary drain age plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. 7. A geotechnical soils report for the site is required per the 2017 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 8. Erosion control measures to meet the City requirements shall be provided. 9. The current City of Renton Surface Water Standard Plans that shall be used in all drainage submittals are available online at the City of Renton website. 10. The 2021 Surface water system development fee is $2,000 per new single family lot. Fees that are current will be charged at the time of permit issuance. TRANSPORTATION 1. The proposed development fronts Park Avenue N along the west property line. Park Avenue N is classified as a Collector Arterial. Existing right-of-way (ROW) width in Park Avenue NE is approximately 57 feet. To meet the City’s complete street standards for collector arterial streets, minimum right of way width is 83 feet. Nicoli Short Plat - PRE21-000144 May 11, 2021 Page 4 of 5 a. The Transportation Division has no plans to widen Park Avenue N at this time. Development Engineering would support a modification request by the Applicant to provide the following modified street improvements on Park Avenue N: maintain a pavement width of 36 feet, install a 0.5-foot curb, an 8-foot planting strip, a 5-foot sidewalk, 2 feet of clear space at back of walk, street trees and storm drainage improvements. Dedication to accommodate these improvements will be required, pending field survey. 2. Street grades shall not exceed 15 percent. 3. Refer to City code 4-4-080 regarding driveway regulations: a. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage. b. The maximum width of a single loaded garage driveway is 9-feet and the maximum width of a double loaded garage driveway is 16-feet. If a garage is not present, the maximum driveway width is 16-feet. c. Driveways shall not be closer than 5-feet to any property line. 4. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 5. The transportation impact fee is based on the type of land use. For a single-family homes, the 2021 transportation impact fee is $10,861.69 per lot. Transportation impact fees are subject to change based on the year the building permit is applied for. GENERAL COMMENTS 1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property frontage or within the site must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 2. Adequate separation between utilities as well as other features shall be provi ded in accordance with code requirements: a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 3. All civil construction permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 4. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on separate sheets. 5. Additional Building Permit Applications will be required for the following: a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040. b. Detention vaults for storm water flow control. c. Demo of any existing structures on the project site(s). 6. Fees quoted in this document reflect the fees applicable in the year 2021 only and will be Nicoli Short Plat - PRE21-000144 May 11, 2021 Page 5 of 5 assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. CONNECT TO EXIST. 12" WATER IN PARK AVE N EXTEND APPROXIMATELY 270 FEET OF 8-INCH WATER MAIN IN ACCESS ROAD EXIST 3/4" METER TO BE CAPPED AT MAIN LINE RE: PRE21-000144 - Nicoli Short Plat Conceptual Water Main Extension Layout 05/11/21 10 ft NEW 1" WATER SERVICE AND METER (TYPICAL) DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: May 13, 2021 TO: Pre-Application File No. PRE21-000144 FROM: Brittany Gillia, Assistant Planner SUBJECT: Nicoli Short Plat 3930 Park Ave N (Parcel No. 3342700532) General: We have completed a preliminary review of the pre-application for the above- referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, Development Services Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are available online at www.rentonwa.gov Project Proposal: The applicant is proposing to subdivide one (1) existing single family parcel into three (3) lots. The project site (Tax Parcel 3342700532) is located at 3930 Park Ave N and totals approximately 23,149 sq. ft. (0.53 acres) in area and is zoned Residential-6 (R-6). The site is rectangular in shape with a 20-foot wide pipestem off Park Ave N. The existing single family residence and associated accessory structures are proposed to be removed. Proposed Lot A would have an area of 9,185 sq. ft. and would access off Park Ave N via the existing pipestem. Proposed Lot B would have an area of 6,760 sq. ft. and Proposed Lot C would have an area of 7,203 sq. ft. and both are proposed to be accessed via a 20’ ingress/egress and utility easement leading up to the pipestem driveway. The site is mapped within a Moderate Landslide Hazard and Sensitive Slope area. Current Use: The property is developed with an existing single family home and associated accessory structures that are all proposed for removal. Zoning/Density Requirements: The subject property is zoned Residential-6 (R-6). The minimum density in the R-6 zone is 3.0 dwelling units per net acre (du/ac) and the maximum density is 6.0 du/ac. Private access easements, critical areas and public right-of-way are deducted from the total area to determine net density. For purposes of calculating net density: All fractions shall be truncated at two numbers past the decimal. Should a calculation result in a fraction of a dwelling unit that is 0.50 or greater, the fraction shall be rounded up to the nearest whole number, for example, 4.56 dwelling units becomes 5.0. Should a calculation result in a fraction that is less than 0.50, the fraction shall be rounded down to the nearest whole number, for Nicoli Short Plat, PRE21-000144 Page 2 of 5 May 13, 2021 example, 4.49 dwelling units becomes 4.0 dwelling units. The proposal for 3 lots on the 0.53 acre gross site area would result in a gross density of 5.65 dwelling units per acre (3 lots / 0.53 acres = 5.65 du/ac). The applicant would be required to submit a density worksheet demonstrating compliance with net density at the time of formal land use application. Development Standards: The project would be subject to RMC 4-2-110A, “Development Standards for Single Family Zoning Designations” effective at the time of complete application (noted as “R-6 standards” herein). Minimum Lot Size, Width and Depth – The minimum lot size permitted in Zone R-6 is 7,000 square feet for parcels less than one acre, with one lot allowed to be sma ller than the required minimum lot size. This single lot is allowed to be 6,250 square feet in Zone R-6. Minimum lot width is 60 feet for interior lots, or 70 feet for corner lots. Minimum lot depth is 90 feet. The proposed lots would provide adequate area for compliance with the minimum area required, however Lots A and B would not provide the minimum 90-foot depth required. Building Standards – The R-6 standards allow a maximum building coverage of 40% of the lot area. The maximum impervious coverage in the R-6 zone is 55%. The maximum wall plate height is restricted to 24 feet, and the buildings shall not be more than two stories. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height; common rooftop features, such as chimneys, may project an additional four (4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.) shall not extend above the maximum wall plate height unless the projection is stepped back one-and-a-half (1.5) horizontal feet from each façade for each one (1) vertical foot above the maximum wall plate height. Detached accessory structures are restricted to a maximum wall plate height of 12 feet. The gross floor area must be less than that of the primary structure. Accessory structures are also included in building lot coverage calculations. The proposal’s compliance with the building standards for the new homes would be verified at the time of building permit review. Setbacks – Setbacks are the minimum required distance between the building footprint and the property line and any private access easement or tract. The required setbacks for the R-6 zone are: Front yard: 25 feet for the primary structure; Rear yard: 25 feet; Side yards: combined 15 ft. with not less than 5 ft. on either side. Corner lots required to have a front yard and a secondary front yard are relieved of the requirement to have a rear yard; in place of a rear yard setback, the side yard setback of the zone shall apply. Lots adjacent to both public ROW and driveway tract frontage are classified as corner lots. Setback compliance for the new homes would be verified at the time of building permit review. Residential Design and Open Space Standards: The Residential Design and Open Space Standards contained in RMC 4-2-115 would be applicable to any new residential structures. Access: Access to proposed Lot A would be provided via the existing 20-foot wide pipestem. Access to proposed Lots B and C would be provided via easement access off of the pipestem connecting to Park Ave N. Flag lots may be permitted for new plats to achieve the minimum density within the Zoning Code when there is no other feasible alternative to achieving the minimum density. The “flagpole” shall not exceed one hundred fifty feet (150') in length and not be less than twenty feet (20') in width. The portion of the lot narrower than eighty percent (80%) of the minimum permitted width shall not be used for lot area calculations or for the Nicoli Short Plat, PRE21-000144 Page 3 of 5 May 13, 2021 measurement of required yard setbacks. Land area included in private access easements shall not be included in lot area calculations. Flag lots shall not abut one another. Shared driveways may be allowed for access to four (4) or fewer residential lots, provided: a. At least one of the four (4) lots abuts a public right-of-way and the street frontage of the lot is equal to or greater than the lot width requirement of the zone; b. The subject lots are not created by a subdivision of ten (10) or more lots; c. A public street is not anticipated by the City of Renton to be necessary for existing or future traffic and/or pedestrian circulation through the short subdivision or to serve adjacent property; d. The shared driveway would not adversely affect future circulation to neighboring properties; e. The shared driveway is no more than three hundred feet (300') in length; and f. The shared driveway poses no safety risk and provides suff icient access for emergency vehicles and personnel. Shared driveways shall be within a tract; the width of the tract and paved surface shall be a minimum of sixteen feet (16'); the Fire Department may require the tract and paved surface to be up to twenty feet (20') wide. If a shared driveway abuts properties that are not part of the subdivision, an eight foot (8') wide landscaped strip shall be provided between the shared driveway and neighboring properties. The landscape strip shall be within a tract and planted with a mixture of trees, shrubs, and groundcover. The shared driveway may be requi red to include a turnaround per subsection H of RMC 4-6-060. The maximum grade for the shared driveway shall not exceed fifteen percent (15%), except for within approved hillside subdivisions. Parking: Each lot is required to accommodate off-street parking for a minimum of two vehicles. Compliance with parking regulations would be verified at the time of building permit review. Driveways: Driveways exceeding 8% must provide slotted drains at the lower end of the driveway. The maximum driveway slopes cannot exceed 15%. If the grade exceeds 15%, a variance is required. The maximum width of single loaded garage driveways shall not exceed 9 feet and double loaded garage driveways shall not exceed 16 feet. Compliance with the driveway regulations would be verified at the time of formal land use review. Landscaping: With the exception of critical areas, all pervious area shall have landscape treatment. Landscaping may include hardscape such as decorative paving, rock outcroppings, fountains, plant containers, etc. Ten feet (10') of on-site landscaping is required along all public street frontages. Where there is insufficient right-of-way space or no public frontage, street trees are required in the front yard subject to approval of the Administrator. A minimum of two (2) trees are to be located in the front yard prior to final inspection. A conceptual landscape plan shall be provided with the formal land use application as prepared by a registered Landscape Architect, a certified nurseryman or other certified professional. Significant Tree Retention: A Tree Retention/ Land Clearing (Tree Inventory) Plan along with a tree retention worksheet shall be provided with the formal land use application. The tree retention plan must show preservation of at least 30 percent (30 %) of significant trees, and indicate how proposed building footprints would be sited to accommodate preservation of Nicoli Short Plat, PRE21-000144 Page 4 of 5 May 13, 2021 significant trees that would be retained. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that an insufficient number of trees can be retained. In addition to retaining 30 percent of existing significant trees, each new lot would be required to provide a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected trees that do not contribute to a lot's required minimum tree density shall be held in perpetuity within a tree protection tract. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen inches ( 18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; Other significant native evergreen or deciduous trees; and Other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. The Administrator may require independent review of any land use application that involves tree removal and land clearing at the City's discretion. Critical Areas: The site is mapped within a Moderate Landslide Hazard and Sensitive Slope designation. A geotechnical soils report will be required at the time of for mal land use application. Environmental Review: Short plats are categorically exempt from Environmental (SEPA) Review except for lands covered by water or critical areas as designated in RMC 4-9-070H.2. The proposed short plat would no longer be exempt from environmental review if further investigation of the site results in the identification of designated critical areas. Permit Requirements: The subdivision of fewer than 10 lots requires a Short Plat application. The application review is administrative and would be processed within an estimated time frame of six to eight weeks. The 2021 administrative short plat application fee is $5,680.50 ($5,410.00 each plus a 5% Technology Surcharge Fee). Each modification request is $262.50 ($250.00 each plus a 5% Technology Surcharge Fee). All fees are subject to change. A Short Plat Submittal Requirements Checklist is linked here. Additional information and forms needed for the land use application submittal can be found on the City’s new website by clicking “Land Use Applications” on the Community & Economic Development page, then “All Forms (A to Z).” The City now requires electronic plan submittal for all applications. The City’s Electronic File Standards can be found on the City’s website at https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=867190&dbid=0 Once Preliminary Short Plat approval is obtained, the applicant must complete the required improvements and dedications, as well as satisfy any conditions of the preliminary approval before submitting for Final Short Plat review. Once final approval is received, the plat may be recorded. The newly created lots may only be sold after the plat has been recorded. In addition to the required land use permits, separate construction and building permits would be required. Nicoli Short Plat, PRE21-000144 Page 5 of 5 May 13, 2021 Public Notice: A minimum of one Public Information Sign is required for a Short Plat application. The applicant is responsible for the procurement, installation and maintenance of the sign. Detailed information regarding the public information sign requirements is provided on the City of Renton website “All Forms” page noted above. Fees: In addition to the applicable building and construction fees, impact fees would be required. Such fees would be payable prior to building permit issuance. The 2021 impact fees are as follows: • A Transportation Impact Fee based on $10,861.69 per each new detached dwelling unit. • A Parks Impact Fee based on $2,914.99 per each new detached dwelling unit. • A Fire Impact fee of $829.77 per each new detached dwelling unit. • Renton School District Impact Fee is $7,681.00 (plus a 5% surcharge fee) per each new detached dwelling unit. A handout listing Renton’s development-related fees is available on the City of Renton website for your review. Note: When the formal application materials are complete, the applicant is required to have the application materials pre-screened prior to submitting the complete application package. Please contact Brittany Gillia, Assistant Planner at bgillia@rentonwa.gov for pre-screening. Expiration: Upon approval, the Short Plat is valid for five years with a possible one year extension (RMC 4-7-070M). It is the responsibility of the owner to monitor the expiration date.