HomeMy WebLinkAbout221.30 (2022)6" MIN. 2' MIN. 6" MIN. 3' MIN. PIPE BEDDING CONCRETE BLOCK A B STRAP FOOTING ANCHOR 6" MIN. (TYP.) 12" MIN. 6" MIN. 6" MIN. CONCRETE FOOTING KEYED INTO UNDISTURBED SOIL AS SHOWN GENERAL NOTES: 1.FOR SOLID WALL HDPE PIPE LAID ON THE SURFACE, PIPE MUST BE FREE TO SLIDE INSIDE A 4' LONG SECTION OF PIPE ONE SIZE DIAMETER LARGER. 1" MIN. DIA. STEEL ROD (STRAP) CLAMPED SECURELY TO PIPE CONCRETE FOOTING KEYED INTO UNDISTURBED SOIL AS SHOWN 6" MIN. 12" MIN.2 x PIPE DIA. MIN. SECTION A CONCRETE BLOCK ANCHOR SECTION B TABLE 4.2.1.A3 MAXIMUM PIPE SLOPES AND VELOCITIES PIPE MATERIAL PIPE SLOPE ABOVE WHICH PIPE ANCHORS REQUIRED AND MIN. ANCHOR SPACING MAX. SLOPE ALLOWED MAX. VELOCITY AT FULL FLOW CMP, SPIRAL RIB, PVC1 20% (1 ANCHOR PER 100 LF OF PIPE)30%3 30 FPS CONCRETE, CPE, OR PP1 10% (1 ANCHOR PER 50 LF OF PIPE)20%3 30 FPS DUCTILE IRON2 20% (1 ANCHOR PER PIPE SECTION)NONE NONE SOLID WALL HDPE2 20% (1 ANCHOR PER 100 LF OF PIPE, CROSS-SLOPE INSTALLATIONS ONLY) NONE NONE NOTES: 1 THESE MATERIALS ARE NOT ALLOWED IN LANDSLIDE HAZARD AREAS. 2 BUTT-FUSED OR FLANGED PIPE JOINTS ARE REQUIRED; ABOVE GROUND INSTALLATION IS RECOMMENDED ON SLOPES GREATER THAN 40%. 3 A MAXIMUM SLOPE OF 200% IS ALLOWED FOR THESE PIPE MATERIALS WITH NO JOINTS (ONE SECTION), WITH STRUCTURES AT EACH END, AND WITH PROPER GROUTING STRAP PIPE ANCHOR STD. PLAN - 221.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT