Loading...
HomeMy WebLinkAbout236.00 (2022)DESIGN WATER SURFACE OPTIONAL 5'x10' ACCESS VAULT MAY BE USED IN LIEU OF TOP ACCESS OUTLET PIPE 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 3.PROVIDE WATER STOP AT ALL CAST-IN-PLACE CONSTRUCTION JOINTS. PRECEAST VAULTS SHALL HAVE APPROVED RUBBER GASKET SYSTEM. 4.VAULTS <10' WIDE MUST USE REMOVABLE LIDS. 5.PREFABRICATED VAULT SECTIONS MAY REQUIRE STRUCTURAL MODIFICATIONS TO SUPPORT 5' X 10' OPENING OVER MAIN VAULT. ALTERNATIVELY, ACCESS CAN BE PROVIDED VIA A SIDE VESTIBULE AS SHOWN. 6.ALL VAULT AREAS MUST BE WITHIN 50' OF AN ACCESS POINT. 7.FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HAND-HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE. 8.MINIMUM DIAMETER FOR ALL ACCESS OPENINGS, EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES. 9.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 10.FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO THE TOP OF THE VAULT EXCEEDS 24 INCHES, AN ACCESS STRUCTURE EQUIVALENT TO A TYPE 2 CATCH BASIN OR TYPE 1 MANHOLE SHALL BE USED. 11.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 12.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. FLOW 5%5%FLOW 5' 10' 5'x10' REMOVABLE LOCKING PANEL FOR VAULTS GREATER THAN 1,250 SF OF FLOOR AREA FLOW WALL FLANGE, TYP 16" MAX. 4" MIN. 12" 12" 6" SEDIMENT STORAGE FRAMES, GRATES, AND ROUND SOLID COVERS MARKED "DRAIN" WITH LOCKING BOLTS PLAN VIEW 6" MIN. 2' MIN. 2' MIN. 4' MIN. NOTES: HANDHOLDS, STEPS OR LADDER CAPACITY OF OUTLET PIPE NOT LESS THAN DEVELOPED 100 - YR DESIGN FLOW FLOW RESTRICTOR FLOW SECTION A A SUMP AREA SEE NOTE 11 (TYP.) SEE NOTE 11 (TYP.) 12" MIN. VENTILATION PIPE (TYP), SEE NOTE 9 24" ACCESS MANHOLE WITH BOLT LOCKING RING AND COVER 4' MIN. SEE NOTE 11 (TYP.) SEE NOTE 11 (TYP.) 2' MIN. COVER, SEE NOTE 10 7' MIN. 5'x10' GRATE ACCESS DOORS OR REMOVABLE PANEL TYPICAL DETENTION VAULT STD. PLAN - 236.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT