HomeMy WebLinkAboutR-407222LEGEND m TYPE 1 JUNCTION BOX FP-Bl PULL BOX LIGHT STANDARD - SINGLE ARM -� LIGHT STANDARD - DOUBLE ARM 0 WIRE NOTE O CONSTRUCTION NOTE - - - PVC CONDUIT ® SERVICE CABINET m 50 KVA PSE VAULT R.A. 1 /2020 G.N. 1 /2020 R.A. 1 /2020 R.A. 1 /2020 V AF-------- - - - SOUTH 48TH STREET BREAKER SCHEDULE SERVICE & CIRCUITS MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS VOLTS CIRCUIT A1,A2,13,16,18 20 30 240 REVISIONS BY I APPR. S 4 CONSTRUCTION NOTES OFURNISH AND INSTALL ALUMINUM LIGHT STANDARD, 35' MOUNTING HEIGHT, 240 VAC, DOMUS DMS5X108W48LED4K-T-LED3K AND AT 14' DOMUS DOS- 35W32LED4K- T- LE3F. INSTALL CONCRETE FOUNDATION AT LOCATIONS SHOWN ON THE LUMINAIRE SCHEDULE. SEE DETAILS SHEET SL4 AND CITY OF RENTON STD PLAN 117.1. Z OFURNISH AND INSTALL ALUMINUM LIGHT STANDARD 14' MOUNTING HEIGHT, 240 VAC, CY17T4X-VS3AR-34W-4K. INSTALL CONCRETE FOUNDATION AT LOCATIONS ON THE LUMINAIRE SCHEDULE. SEE DETAILS ON SHEET SL4 AND 10 0 10 CITY OF RENTON STD PLAN 116.1. 20 O3 FURNISH AND INSTALL JUNCTION BOXES, WIRING, FUSE KITS, SPLICE KITS, AND GROUND RODS TO MAKE THE SYSTEM COMPLETE/ OPERATIONAL. SEE DETAILS ON SHEET SL4 AND CITY OF RENTON STD PLAN 120. O4 FURNISH AND INSTALL CONCRETE FOUNDATION, SERVICE CABINET AND JUNCTION BOX AT STA 3+27, 16' RT. ON TALBOT ROAD SOUTH. SERVICE CABINET SHALL BE SKYLINE MODEL 58309-GHRS OR APPROVED EQUAL. SEE „ , SCALE 1 = 20 DETAIL SHEET SL4 AND CITY OF RENTON STANDARD DETAILS 122.1, 122.2. O5 CONNECT TO PROPOSED PSE VAULT ON THE SOUTHWEST CORNER OF S. 48TH COURT AND TALBOT ROAD S. GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC), PSE DETAILS, CITY OF RENTON STANDARD PLANS, WSDOT, AND THESE PLANS. 2. THE LUMINAIRE POLES ON TALBOT ROAD SHALL BE HAPCO RSA SERIES ROUND POLE OR APPROVED EQUAL. 3. THE LUMINAIRES ON TALBOT ROAD SHALL BE DOMUS DMS5X108W48LED4K-T-LE3F AND DOMUS DOS- 35W32LED4K-T-LE3F OR APPROVED EQUAL. 4. THE LUMINAIRE POLES ON NEW STREETS SHALL BE LUMEC P135A-14-85-BKTX OR APPROVED EQUAL. 5. THE LUMINAIRES ON NEW STREETS SHALL BE CYl l T4K-VS3AR-2-34W-4K OR APPROVED EQUAL. 6. ALL CONDUIT USED FOR THE LIGHTING SYSTEM SHALL BE SCHEDULE 40 PVC, SIZED AS SHOWN ON THE PLANS. PVC SCHEDULE 80 SHALL BE USED ON ROADWAY CROSSINGS OR UNDER VEHICLE TRAFFIC. 7. ALL WIRE SHALL BE U.S.E. COPPER SIZED PER WIRING SCHEDULE. 8. POLE ID NUMBERS WILL BE ISSUED UPON INSTALLATION OF POLE. CONTACT TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL AT 425-430-7423 FOR POLE ID NUMBERS. THESE PLANS ARE ';IS -BUILT' AND THE INFORMATION SHOWN ACCURATELY REFLECTS EMSTING FIELD CONDITIONS AS OF THIS DATE: MARCH 3, 2021 STEVEN D. McCASREY PL5 42676 LUMINAIRE SCHEDULE POLE POLE POLE MOUNTING MAST ARM SERVICE/ MAST ARM / OR POLE STATION OFFSET HEIGHT LENGTH LUMINAIRE TYPE CIRCUIT POLE TYPE POLE TOP TYPE LAT / LONG VOLTAGE POLE I.D. NO. (FEET) (FEET) (FEET) (FEET) 47026'10.4553", 1 1+11 19.90' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE -122 12 50.9145 120/240 2 1 +33 19.50' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.4533" 120/240 -122012'50.6043". 3 1+86 19.80' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.4542" 120/240 4 2+02 19.50' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.0663", 120/240 -122° 12'49.5942" 5 2+45 19.50' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.4512"1 120/240 -122012'48.9641" 6 11+62 13.60' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026"0.0639", 120/240 -122012'48.6625" 7 12+18 11.90' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.6154", 120/240 -122 12 48.6447 8 12+48 11.90' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 120/240 12 -1221226'10.948302.3022 9 11+37 12.30' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47°26'09.8113", 120/240 -122 12 48.2822 10 10+92 12.30' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'09.3711", 120/240 -122012'48.6341" 11 10+62 11.80' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'09.0786", 120/240 -122012'48.2790" 12 10+04 12.60' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'08.5075", 120/240 -122012'48.2790" 13 3+15 17.00' LT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.3867"'If 120/240 14 3+36 15.50' RT 14' 0 CY1 7T4X- VS3AR- 2- 34W- 4K A2 P135A-14-850-BKTX LUMEC 240 PED FIXTURE 47026'10.0656", 120/240 -122 12 47.6679 15 100+87 26.00 LT 35> /14 8 /4 DOMUS DMS5X108W48LED4K-T-LE3F Al HAPCO RSA SERIES RSA 65638-010, 8 47026'11.0765", 120/240 DOMUS DOS- 35W32LED4K-T-LE3F -122012'47.2483" 16 99+61 25.90 LT 35> /14 8 /4 DOMUS DMS5X108W48LED4K-T-LE3F Al HAPCO RSA SERIES RSA 65638-010, 8„ 47026'09.8345", 120/240 DOMUS DOS- 35W32LED4K-T-LE3F -122012'47.231" 17 99+55 26.20' LT 35'/l4' 8'/4' DOMUS DMS5X108W48LED4K-T-LE3F Al HAPCO RSA SERIES RSA 65638-010, 8" 47026'08.7826", 120/240 DOMUS DOS-35W32LED4K-T-LE3F -122012'47.2200" WIRE / CONDUIT SCHEDULE RUN CONDUIT NO. SIZE CONDUCTORS COMMENTS 2" PVC 2-#10 LIGHTING CIRCUIT 2" PVC 2 #8 LIGHTING CIRCUIT Al 1 #10 GROUND 2" PVC 3 #2 TO PSE SERVICE GROUND DN TRAFFIC CONSULTANTS 8316 - 309th Avenue SE Preston, WA 98050 Info@dntraffic consultants.com PANEL SCHEDULE NO. LOCATION: STA. 10+03 120/240 VOLTS 1 PHASE 3 WIRE S-1 SERVING: STREET LIGHTS 100 AMP with MAIN BREAKER CKT TRIP TRIP CKT NO. LOAD DESCRIPTION KVA ® AMPS I AMPS 20 1 2 20 KVA LOAD DESCRIPTION NO. Al STREET LIGHTS - 15,16,17 .287 .474 RESIDENTIAL LIGHTS 1-14 A2 9 ^10 11 ,-,12 13 GFCI DUPLEX RECEPTACLE 2.40 20 13^ ^14 15^ .-,16 15 1.80 STRIP HEATER 16 17^ ^18 15 1.80 PHOTOCELL 18 19^ ^20 REMARKS: CONNECTED LOAD: 6.76 KVA 45 AMPS DEMAND LOAD: KVA AMPS SAPPHIRE ON TALBOT CITY OF RENTON SL1 ILLUMINATION PLAN SHT 1 OF 5