Loading...
HomeMy WebLinkAboutR-406807A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M. \ o ( CB M � \ USED OIL TANKS \ R/M.•21.00 \ 1E(NW)4'PVC20.01 (2)BLi O BTU 17.56 �b QD \ Cv OG CB �I \ I co ® '� SE 4'PW 19.63 %IM.21.74 \ j \ \ (J 9 HVAC � \ BL D 11 > i E(NE)8'PVC.18.82 / ti 00 1E(NE)6 �G'P.20.03 \ \ O \ BP: 7+32.10 r(SW)8'PVC:18.80 / 0SW) 4 P:19.93 \ \ \ \ CB BTU=18.60 / , i ti M.18.5201 \ R/M.•22.01 / - 9 0 /E(SW)8'PLASTIC:18.86 R j i / / WATER SHUT OFF / w IE(NE)8'PVC:18. / , I \ / �o VALVE c�1E(W)8'PVC 18.71 \ Sp BT . 10E 1 CB \ W/ SOL i / y� \ J, \ \ \ RIM.•23.90 l \ 22 lE(NE)4'lP.22.45 5' CPEP ti / / \ i \ 1F(NW)6'PVC.•2216 Z \ c�0 (E 9 E, 8'rPVC tiG \ Rr�A• �n �4 PROPOSED 12"SDCO \ FENCE RIM TO GRACl)DE Z \\ X � ��\ \ \ ���/ IE=28.91 Jp END PAVING AND CURB WORK AT f �\ \\ o ��\\ PROPANE TANK \ 1g \ STATION=14+75.00 X CB LUz� ` ` 1SPh� RIM.•21.2 �\ <\ \ F o 1-STORY STEEL / \ lE 20.14 \ LU\ \ �� ry o BLD6 15801 SO /RO�b'CP.•20.04 �\ `\ ` RAISE MH LID TO GRADE FT � \ 1E6 W)6'PVC20.04 \ CONNECT TO EX CB IE=18.00 12" (IN)SE BTM.18.54 \ \ IE=18.00 18"(OUT)NW C113#61 CB TYPE I \/ RIM=22.52 IE=18.17 8"(IN)SE IE=18.1712"(OUT)N 12g2 f P� / ijA \ \ SDMH(5v O ` \ '\ �1E(SW)8 ADS 19. ti ti PS 22\ \ o ASPH o `\ ` lE(NE)8'lP ELB iz ti i \ BTM.• 16.36 �\ / ^ APPLY ECO - MIX HYDROSEED ASPH �S \ \ / \\ ON ALL 3:1 FILL SLOPES - - - cn ' REMOVE THRU-CURB FRAME 19 LF 8" DI @ 0.6% Aso \ \ \ :� o \ / AND GRATE & REPLACE WITH ASPH N s \ �P NEW STANDARD FRAME WITH �o s o \ ` o `� \ `\ 22.45 1E sE)6 ADS: / os GG�NEG(/ \ NOTE: / ADA HERRINGBONE GRATE �, ��,�G»��,- \ B( S G / PROPOSED STORM WATER / ADA RAMP \ EG F�GN CB SYSTEM IS PRIVATELY \ '� 21.70 \ `\ CB RIM•20.82 �CB OWNED AND MAINTAINED \ SEE DETAIL \. \ RIM.•20.88 EX CB TYPE l /1E(SE)47P:19.61 \ RIM.•21.27 \ CVO 1-C2-12-1 \ `\ 3c' LE(SE)6'PVC:19.53 W/ SOLID LOCK/N lD IE(W)8'CP:19.41 \ 22.4 / 1E(NW)6'CP.•I9.I9 RLM 22.10 BTM.19.37 BTM <. \ CONNECT TO EX CB C I 21.60 \ \ lE(NE)6'PVC.19.13 /E 18 NE 15 CPEP I V 21.66 G \ � - IE(SW)12ADS:18.88 18.20 SW 15" CPEP IE=19.41 8"( U )N PLACE ADDITIONAL CB#C1 CB TYPE I-L BTM.•17.79 /E 18.00 N 18" CPEP / �� �► I� STRUCTURAL FILL SOIL AT BASE H RIM=21.99 1.70' O �V�y `\ +\ 22.38 - - - - � W IE=18.1912 (IN)SW - \ 22.64 CONNECT TO EX CB \ OF SLOPE TO ELIMINATE LOW = IE=17.6918"(IN)SE � �o\\ IE=18.36 8"(IN)SW RIM.-21.12 F 8' D� @ 0.9% \ \ / POINT AS NEEDED TO PREVENT IE=17.6918 (OUT)NW \ / / IE=18.36 8"(OUT NE IE(SE)fi CP.•19.08 / \ PONDING AGAINST SLOPE 22.54 ) / � � / 17 F 12 \ lE(NE)8 ADS O j �� � SEf SD W \ D I BTM.1 ASPH C� W 2217 RIDGE LINE / ( W)4'PVC ELBOW.•20.78 / \ 22.72 BTM.• 18.38 / / \ LU GPS / / EX 22.10 00, dill \ / !/ No �\ CB#A8 CB TYPE I / 6" DOM Sr1C WATER MFTF = O E E \ RIM 22.52 � V �/ 6 -OR STD PLAN 32C \\ \P ' 9+43.28 IE=20.47 12"(IN)S o0 / ADA RAMP SEE DETAIL \ IE=20.42 12"(OUT)N 'A ADA 38 LF 12" DI @ 3.9% \ Mid: 12+97.92 i / EX 18" PSE BYPASS CB#C2 CB TYPE I \ STORM SYSTEM RIM=21.96 CB#A5 CB TYPE I IE=19.6712"(OUT)NE- RIM=21.45 1 CARTRIDGE STORMFILTER \ \ Mid: 9+88.65 IE=19.5012"(IN)SE SEE DETAIL (� 31 LF 12" IE=18.4512"(OUT)N C`210 DI @ 0.7% 3 PC: 12+23.01 / 26 4 CARTRIDGE STORMFILTER 9�F72 \ 11+00 12+00 SEE DETAIL 107 LF 12" DI @ 0.8% C-211 . a....: ;.:" @0 \ : 10+34.03 10+50 23 11 +50 2 to llWl� . . . . . . . . \ S o 41 LF - - - - - - - - - - - - - --. :' _` i 12 D/@ 'L5 10% LIMIT LIMIT 12" DI Cq0.6% 92 LF 12" DI @ 0.5% 4. - - - - - - - - - - - - - - B#A CB TYPE 0 _ - t 0 0 Ll ITLIMIT LI ITMEMO 0_- �__ RiM=22:07-now-L4M -� �� I - - - - - - �MF��- -- - - -- - ��-t#hAFT-Ldto41T # - INJ IE-17.4718"(IN)NW CB#A6 CB TYPE IE=17.5712"(IN)S RIM=22.11 30' DRIVEWAY APRON CB#A7 CB TYPE I TW=23.50 p - CB#A10 CB TYPE I B AND CONCRETE PAD BW=23.00 o o CB#A9 CB TYPE I TW=24.10 TW=25.10 W/ SOLID IE=19.71 12"(IN)S RIM=22.26 g ^ BW=23.00 RIM=24.24 BW=23.00 TW=25.55 SEE ENLARGEMENT CONTRACTOR TO RAISE RIM TO °° RIM=23.18 IE=21.44 12"(IN)SE BW=23.50 LOCKING LID IE=19.71 12 (OUT)NW C-212 IE=20.01 12 (IN)S `IE=20.9812"(IN)S IE=21.4412 (OUT)N IE-20.01 12"(OUT)N GRADE AND INSTALL NON-SKID LID m W W - - " RIM=23.45 IE=20.9812"(OUT)N Legend ' PROPERTY LINE GRAVEL 12" D/ W W WATER MAIN ` ASPHALT PAVEMENT 1 ! 1 t 1 ! 1 ! ROCKERY WALL F�FDC0 Pl o WVM FH/FDC/PIV/VALVE 0 10 20 40 CONCRETE PAVEMENT 8" SD @ xx% STORM DRAINAGE PIPE ® 63PM WATER VAULT/METER CONSTRUCTION RECORD iiiGRAVEL O YD/CO/CB/CB 2/MH This construction record drawing is a copy of COUGHLIN PORTER LUNDEEN and has been SCALE 1 =20' CONCRETE RETAINING WALL m e ❑ O STORM FILTER CB verified invert and rim elevations of the storm, sa main systems. Field verified invert and rim elevat CONCRETE CURB SANITARY SEWER KLB CONSTRUCTION IN JUN The on -site private storm drainage facilities and D. Bj�� sewer systems were installed in accordance with jy FLUSH CONCRETE CURB SANITARY MHICO the documented field revisions and functi 7 o y RECORD DRAWINGS 07 08 22 SURVEYED: SCALE: 2 VTENW HORIZONTAL- NAD 1983/1991 COUGHLINPORTERLUNDEEN DESIGNED: As SHOWN CITY �+ Transportation Engineering NorthWest DRAWN: VR RENT Q 33708 STRUCTURAL CIVIL SEISMIC ENGINEERING 1�� �CISTIV Transportation Planning I Design I Traffic Impact & Operations PRW ONE INCH DATUM 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 CHECKED: S/0NAL /^n Office (425) 889-6747 801 SECOND AVENUE, SUITE 900 (206) 343-0460 BSB AT FULL SCALE Planning/Building/Public / /fSEATTLE, WA 98104 www.cplinc.comIF NOT 0 Project Contact: Elyse Stemmler, P.E. N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY Phone: 425-250-5004 TBB *RKAVENUE CVNSION PROJEC OO BUILTBY THE CI . SHOWNFOR C) -' EF RENCE�CONLY. P U 1 - - A _--- 1 - TENSION PR OWN FOR RE ENC-E T LU, \� \� �� �� PI: 15+00.22 WIRE Ue STAT =15+ .22 PT: 14 5.86 31.90 ��;�\� �\ TEMP ARY 1. -1 W N . � \ \� ♦ \ FIN PAVI CV WIRE Ei�� \�( SHAL BE CO D BY T Cl Co C 31.36 \ ` \ �� EL=32.18 O / 41 LF 12" \�� ��\�� - Ci PVC 3.7% \ � � \�� V\ r ' \\� �\ CB#A14 CB TYPE id: 14+ 4.34 = \,a. �� ; \�\ \ RIM=31.18 IE=27.38 12"(IN)NE IE=27.43 12" OUT W \ 40 LF 12"\\ice / / PVC @ 3.1 % I N EVEL PAD FOR FUTURE DESIGN - WOOD PP -' BUILD SIGN (UNDER ELEVATION OF TOP WIRE. 51.6 "' a SEPARATE PE ELEVATION OF BOTTOM WIRE: 50.6 PRC:13+72.82 \ I CB#A13 CB TYPE I RIM=30.25 �. IE=26.20 12 (IN)E II 8' SECURIT p \ E=26.2512 (OUT)W FENCE ✓� • \ I - I 2$ CB#Al2 CB TYPE I I \o RIM=28.44 I o IE=24.4412"(IN)E \ I GRAY m IE=24.3912"(OUT)W d CENTERLINE OF I ROAD DESIGN \\ 27 PROFILE \ OWER POLE N ELEVATION OF TOP WIRE: 86.7' \ \ ELEVATION OF BOTTOM WIRE. 64.7' \ CB#A11 CB TYPE I \ \ \ RIM=25.98 \ \ IE=21.8812"(IN)E \ \ IE=21.8812"(OUT)NW \ CB#D1 CB TYPE I < RIM=21.82 \ CONNECT TO EX \ 8" STORM DRAIN \ �LI .... W=24.50 ® g J W=24.00 b' \ ADDRESS: 737 LOGAN AVE N Z OWNER: THE BOEING COMPANY 0 Z w R-406807 x w IN COMPLIANCE WITH CITY OF RENTON STANDARDS w DRAWING > a cad file prepared by Q edited to reflect field nitary sewer and water ions were obtained by E 2022 Q public/private water and the approved plans and on as intended. DATE OF PARK AVENUE NORTH EXTENSION 04/30/2021 0 RENTON, WASHINGTON FIELDBOOK: O N PAGE: DRAWING NO: works Dept. ROADWAY GRADING AND DRAINAGE PLAN C-201 SHEET: 0F:30 O