HomeMy WebLinkAboutR-4068250 00 0 LIJ _O U) z LLI X W W Q Q rr 0 n D 0 U) w z J L, ILLUMINATION POLE SCHEDULE LUM. STREET STATION OFFSET MOUNT. ARM VOLTAGE SERVICE/ WATTAGE LUMINAIRE TYPE - BASE COMMENT POLE NO. HEIGHT LENGTH CIRCUIT ITYPE DISTRIBUTION 0 PARK 9+34.0 26.0' RT 30' 6' 240 (1) 80 LED CYCLONE FIXED NEW ROUND TAPERED STEEL POLE PER COR STANDARD PLAN 115, THIS SHEET. AVE N TRIS2-FCG-3M-80W-4K-PG PARK AVE N 10+85.0 30.0' RT 30' 6' 240 (1) 80 LED CYCLONE FIXED NEW ROUND TAPERED STEEL POLE PER COR STANDARD PLAN 115, THIS SHEET. TRIS2-FCG-3M-80W-4K-PG PARK 12+58.5 30.0' RT 30' 6' 240 (1) 80 LED CYCLONE FIXED NEW ROUND TAPERED STEEL POLE PER COR STANDARD PLAN 115, THIS SHEET. AVE N TRIS2-FCG-3M-80W-4K-PG PARK 14+08.5 36.5' RT 30' 6' 240 (1) 80 LED CYCLONE FIXED NEW ROUND TAPERED STEEL POLE PER COR STANDARD PLAN 115, THIS SHEET. AVE N TRIS2-FCG-3M-80W-4K-PG GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON —SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT—OF—WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48—HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JO° S,' "f WHENEVER CONSTRUCTION IS IN PROGRESS. 9• ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL AT THE EARLIEST POSSIBLE DATE. 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10—FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 07/08/2022 VTENW Transportation Engineering NorthWest Transportation Planning I Design I Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 Project Contact: Elyse Stemmler, P.E. Phone: 425-250-5004 M88 WALL BRACKET ALUM. ALLOY 6063—T6 T/2" ONO LOCK13OLT GR. 18-8 S.S. FLUSH JOINT 4-1/2„ O.D. TAPERED ALUM. POLE 0.188 WALL ALLOY -6%3 T6`-"—'"` SATIN GROUND FINISH 151 HANDHOLE. 4"X6" OPENING W/COVER AND S.S. SCREWS — BASE FLANGE ALLOY 356—T6 WiTH :BOLT COVERS & S.S. SCREWS — SIZE AS REQUIRED 7 5'-9" RADIUS 1 qr-3n 23'-3" 28'-3" 331-3" SHAFT B" O.D. ROUND .LUG 1 r-6" 11-1 /4"' SQ. 2" N.P.S. SLI P FI TTER J 11 " TO 12" DIA. BOLT CIRCLE 4 1/2" OF BOLT ABOVE 4" CONCRETE PAD FINISHED GRADE 2' 25'-0" 30I-0" 35'-0" 40'-0" (4) 1"x42" BNC GALV. STEEL 124 ANCHOR BOLTS WITH NUTS 4' AND WASHERS DEW 4" + PUBLIC WORKS STANDARD 2W - 40' DAVIT POLE VSM. PI4H "' 115 DEPARTMENT DAM 22" 161=1 ze j61 cm] WEIGHT: 32LBS115KG EPA: 1.0 ft' ORDERING TEMPLATE MODEL LENS TRIS2 NIL FGC FGF DIST. 1 2 3 3M 4 5 2HS 3HS 3MHS 4HS ORDERING CODE REFERENCES TRIKA SIDE MOUNT TRIS2 WATT CCT VOLT REDUCER OPTIONS 20W 3K 120 NONE NONE 40W 4K 208 PT 60W 240 PTL 80W 277 PTDR 100W 347 PX 120W 480 SD LENS FGC FLAT GLASS CLEAR FGF FLAT GLASS FROSTED NIL NO LENS DISTRIBUTION HS INTERNAL HOUSE SHIEL❑ CCT 3K 3000K 4K 4000K REDUCER NONE FITS 4" 0.0, X 3" LONG TENON OPTIONS NONE NONE PT PHOTOCELL W/7-PIN RECEPTACLE (ANSI C136,41) PTL LONG LIFE PHOTOCELL W/7-PIN RECEPTACLE (ANSI C136.41) PTDR' 7-PIN RECEPTACLE (ANSI C136.41) PX SHORTING CAP WI7-PIN RECEPTACLE (ANSI C136.41) SD FIELO ADJUSTABLE 10% INCREMENT STEP -DIMMING SWITCH 24 SURVEYED: SCALE: DESIGNED: DMA DRAWN: KEW/VF ONE INCH CHECKED: AT FULL SCALE EMS IF NOT ONE INCH N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY CTB COLOR BK DG MA SI BZ BG GM PG WH TEXTURE OP. FIN. TX MG SM COLOR BK BLACK RAL9005 DG DARK GREEN RAL6012 MA MARINE BLUE RAL5013 SI METALLIC SILVER RAL9005 (SMOOTH ONLY) B2 DARK BRONZE RAL8019 BG BURGUNDY RAL3005 GM MOSS GREEN RAL6005 PG PALE GREY RAL7040 WH WHITE RAL9003 TEXTURE TX TEXTURED SM SMOOTH OP. FIN. (OPTIONAL FINISH) MG MARINE GRADE PRE -FINISH ' Contact factory for wireless control options and more information regarding SD options. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF RENTON i Planning/Building/Public Works Dept. GGG`''O O CpP� OF G INCA O CD� N\pp0RC�FFO\N��pSVpR�``�ENCWPg�p� e� ppNPO��PSN�pG�E P�p 10po0? NS� EE EUFgsRER�SQ Q�gy pS 8 PS ANON ��Nw OBS� \N JOB WAS \NFpR PES NO C "N�g`l HERss OR QRO�pEp R-406825 IN COMPLIANCE WITH CITY OF RENTON STANDARDS PARK AVENUE NORTH EXTENSION RENTON, WASHINGTON ILLUMINATION PLAN DATE: 10/15/2021 FIELDBOOK: PAGE: IL-02 SHEET: OF: 29 30 U a J z _O U) z UJ X LLJ LU > a Q O L.L 2 0 U)