HomeMy WebLinkAboutPRE21000195 and 199_Meeting SummaryPREAPPLICATION MEETING FOR
Bloodworks Renton Donor Center and West Office TI
PRE 21-000195 & 000199
CITY OF RENTON
Department of Community & Economic Development
Planning Division
June 17, 2021
Contact Information:
Planner: Jill Ding, 425.430.6598, jding@rentonwa.gov
Public Works Plan Reviewer: Jonathan Chavez, 425-430-7288, jchavez@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 425.430.7235, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
formal submittal.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
M E M O R A N D U M
DATE: June 11, 2021
TO: Jill Ding, Senior Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Bloodworks NW tenant improvements
1. Existing approved fire sprinkler and fire alarm systems are required to be revised
accordingly and maintained throughout all buildings. Separate plans and permits
required by the fire department. Fully addressable and full detection is required for the
fire alarm system.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: June 16, 2021
TO: Jonathan Chavez, Development Engineering
FROM: Jill Ding, Planning
SUBJECT: Bloodworks Renton West Office TI
600 & 701 SW 39th Street
PRE21-000195 & PRE21-000199
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
1253810020. The following comments are based on the pre-application submittal made to the City of
Renton by the applicant.
WATER
Existing Water Services:
1. 600 SW 39th Street
There is an existing 3-inch domestic water meter, south of the building (MTR-015969).
o The existing backflow prevention device for the domestic service must meet current
standards as required by Washington State Department of Health (WAC 246-290-
490). In accordance with Drinking Water Regulations, the building must have a 1.5-
inch RPBA (Reduced Pressure Backflow Assembly). The RPBA shall be installed inside
an above ground heated enclosure per City Standard Plan 350.2. The RPBA may be
located inside the building if a drainage outlet for the relief valve is provided and the
location is approved by the City Plan Reviewer and City Water Utility Department.
There is an existing 8-inch fire service meter, south of the building (MTR-015801).
o The existing backflow prevention device for the fire sprinkler system must meet
current standards as required by Washington State Department of Health (WAC
246-290-490). In accordance with Drinking Water Regulations, the building must
have an 8” DCDA (Double Check Detector Assembly). Per the City of Renton
standard plan number 360.2, the DCDA must be installed outside the building in a
vault. It may also be installed inside the building at a location pre-approved by the
water utility Cross Connection Specialist. Please contact Mick Holte, Cross
Connection Specialist, by email mholte@rentonwa.gov or by phone at (425) 430-
Bloodworks Renton West Office TI – PRE21-000195 & PRE21-000199
Page 5 of 5
June 16, 2021
7207 to verify that your building is equipped with an approved DCDA, or for any
questions regarding these requirements.
2. 701 SW 39th Street
There is an existing 3/4-inch domestic water meter, south of the building (MTR-001899).
o The existing backflow prevention device for the domestic service must meet current
standards as required by Washington State Department of Health (WAC 246-290-
490). In accordance with Drinking Water Regulations, the building must have a 1.5-
inch RPBA (Reduced Pressure Backflow Assembly). The RPBA shall be installed inside
an above ground heated enclosure per City Standard Plan 350.2. The RPBA may be
located inside the building if a drainage outlet for the relief valve is provided and the
location is approved by the City Plan Reviewer and City Water Utility Department.
There is an existing 8-inch fire service meter, south of the building (MTR-000944).
o The existing backflow prevention device for the fire sprinkler system must meet
current standards as required by Washington State Department of Health (WAC
246-290-490). In accordance with Drinking Water Regulations, the building must
have an 8” DCDA (Double Check Detector Assembly). Per the City of Renton
standard plan number 360.2, the DCDA must be installed outside the building in a
vault. It may also be installed inside the building at a location pre-approved by the
water utility Cross Connection Specialist. Please contact Mick Holte, Cross
Connection Specialist, by email mholte@rentonwa.gov or by phone at (425) 430-
7207 to verify that your building is equipped with an approved DCDA, or for any
questions regarding these requirements.
3. As the existing water services will be reused, no water system development charges are
applicable.
SEWER
1. Sewer service is provided by City of Renton.
2. As the existing water services will be reused, no water system development charges are
applicable.
SURFACE WATER
1. All tenant improvements will occur within the existing building. Since no new plus replaced
impervious area will be added to the site, no drainage report is required.
TRANSPORTATION
1. As this project is proposing an interior remodel and no new construction or additions valued at
over $150,000, no street frontage improvements or right of way dedication are required.
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: June 17, 2021
TO: Pre-Application File No. 21-000195 & 000199
FROM: Jill Ding, Senior Planner
SUBJECT: Bloodworks Renton Donor Center and West Office TI
600 SW 39th St (Suites 101A & C) and 700 SW 39th St
(Parcel No. 1253810020)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, Development Services Director, and City Council). Review
comments may also need to be revised based on site planning and other design changes required
by City staff or made by the applicant. The applicant is encouraged to review all applicable
sections of the Renton Municipal Code. The Development Regulations are available for purchase
for $50.00 plus tax from the Finance Division on the first floor of City Hall or online at
www.rentonwa.gov.
Project Proposal: The applicant, Puget Sound Blood Center, is proposing interior improvements
of approximately 6,074 square feet in two vacant, existing suites (101A & C) at 600 SW 39th St and
tenant improvements of approximately 1,925 square feet of existing shell space at 700 SW 39th
St into offices. Some minor exterior building alterations are proposed including modifications to
existing doorways and the addition of new windows. No changes in access or parking are
proposed. The project site totals 17.99 acres and is located in the Industrial, Light (IL) zone and
Employment Area Comprehensive Plan Land Use designation. No trees or vegetation are
proposed for removal as part of the project. According to COR Maps, multiple critical areas are
present on the site including a high seismic hazard, a special flood hazard area, and the 200-foot
shoreline jurisdiction of Springbrook Creek.
Current Use: The site is developed with as the Times Square Office Park and the associated surface
parking.
Comprehensive Plan/Zoning: The property has a Comprehensive Plan land use designation of
Employment Area (EA) and is zoned Industrial - Light (IL). The IL zoning designation is primarily
intended to provide areas for low-intensity manufacturing, industrial services, distribution,
storage, and technical schools. The proposed Renton bloodworks would be considered a
Medical Office use, which is an outright permitted use in the IL zone.
Page 2 of 5
June 17, 2021
Bloodworks Renton Donor Center and West Office TI
Development Standards: The project would be subject to RMC 4-2-120B, “Development
Standards for Industrial Zoning Designations” effective at the time of complete application (noted
as “IL standards” herein). These standards are available on the City’s website at
https://www.codepublishing.com/WA/Renton/#!/Renton04/Renton0402/Renton0402130A.htm
l
Minimum Lot Size, Width and Depth: There are no minimum requirements for lot width or depth
IL in the zone for lots created after September 1, 1985. The minimum lot size for lots created after
September 1, 1985 in the CO zone is 35,000 square feet. No changes are proposed to the lot size,
width or depth as part of the future tenant improvement project.
Lot Coverage: The IL zone allows a maximum building coverage of 65 percent, or 75 percent if
parking is provided within a building or within an on-site parking garage. There is no maximum
impervious surface coverage for the zone. The submitted site plans indicate that the proposed
project will not increase the building coverage on the site. No changes are proposed to the
existing building or impervious surface coverage on site.
Setbacks: Setbacks are the distance between the building and the property line or any private
access easement. Setback requirements in the IL zone are as follows:
Minimum Front Yard 20 ft; When abutting a Principal Arterial street
15 ft; All other streets, except 20 ft if a lot is adjacent to or
abutting a lot zoned residential.
Minimum Side Yard
Along a Street
20 ft; When abutting a Principal Arterial street
15 ft; All other streets, except 50 ft if a lot is adjacent to or
abutting a lot zoned residential.
Minimum Rear and
Side Yards
None, except 20 ft. if lot abuts a lot zoned residential, which may
be reduced to 15 ft through the Site Plan development review
process.
Clear Vision Area In no case shall a structure over 42 in. in height intrude into the
20 ft. clear vision area defined in RMC 4-11-030.
No changes are proposed to the building footprint that would impacts the existing setback
areas.
Gross Floor Area: There are no minimum requirements for gross floor area within the IL zone.
Building Height: The maximum building height permitted in the CA zone is 50 feet, except 100 ft
if the lot is located in the Employment Area (EA). The subject property is located in the
Employment Area (EA) and is therefore allowed a maximum building height of 100 ft. No
changes are proposed to the existing building height.
Screening: Screening must be provided for all surface-mounted and roof top utility and
mechanical equipment. The application must include elevations and details for the proposed
methods of screening if utility and mechanical equipment are added as part of the tenant
improvements. No mechanical or utility equipment was identified in the submitted materials.
See RMC 4-4-095 for specific requirements.
Page 3 of 5
June 17, 2021
Bloodworks Renton Donor Center and West Office TI
Refuse and Recycling Areas: In office, educational and institutional developments, a minimum of
two (2) square feet per every one thousand (1,000) square feet of building gross floor area shall
be provided for recyclables deposit areas and a minimum of four (4) square feet per one thousand
(1,000) square feet of building gross floor area shall be provided for refuse deposit areas. A total
minimum area of one hundred (100) square feet shall be provided for recycling and refuse deposit
areas. The applicant shall demonstrate compliance with the refuse and recycling area
requirements at the time of formal building permit application.
Landscaping: All portions of the development area not covered by structures, required parking,
access, circulation or service areas, must be landscaped with native, drought-resistant vegetative
cover. The minimum on-site landscape width required along street frontages is 10 feet. Street
trees and groundcover in the ROW planter strip will also be required. Interior Tenant
Improvements are not subject to the landscaping requirements.
Tree Retention: If significant trees are proposed to be removed, a tree inventory and a tree
retention plan along with a tree retention worksheet shall be provided with the formal land use
application. The tree retention plan must show preservation of at least 10 percent (10%) of
significant trees, and indicate how proposed building footprints would be sited to accommodate
preservation of significant trees that would be retained. The Administrator may authorize the
planting of replacement trees on the site if it can be demonstrated to the Administrator's
satisfaction that an insufficient number of trees can be retained.
Significant trees include trees with a caliper of at least six inches (6"), or an alder or cottonwood
tree with a caliper of at least eight inches (8"). Trees qualified as dangerous shall not be considered
significant. Trees planted within the most recent ten (10) years shall qualify as significant trees,
regardless of the actual caliper.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant
trees on slopes greater than twenty percent (20%); Significant trees adjacent to critical
areas and their associated buffers; and Significant trees over sixty feet (60') in height or
greater than eighteen inches (18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved;
Other significant native evergreen or deciduous trees; and Other significant non- native
trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical area
or its buffer.
The Administrator may require independent review of any land use application that involves tree
removal and land clearing at the City's discretion.
If staff determines that the trees cannot be retained, replacement trees, with at least a 2-inch
caliper or an evergreen at least 6 feet tall, shall be planted at a rate of 12 caliper inches of new
trees to replace each protected tree removed. A formal tree retention plan prepared by an
arborist or landscape architect would be reviewed at the time of the formal land use application
if any trees are proposed for removal.
Page 4 of 5
June 17, 2021
Bloodworks Renton Donor Center and West Office TI
Fences or Retaining Walls: If the applicant intends to install any fences as part of this project, the
location must be designated on the landscape plan. A wall taller than four feet (4') requires a
building permit. Fences up to six feet (6’) in height are permitted in the rear yard or side yard;
fences up to four feet (4’) are allowed in the front yard. A fence taller than six feet (6') requires a
building permit. A fence shall not be constructed on top of a retaining wall unless the total
combined height of the retaining wall and the fence does not exceed the allowed height of a
standalone fence. New or existing fencing would need to comply with the fence requirements of
the code (RMC 4-4-040).
Retaining walls shall be composed of brick, rock, textured or patterned concrete, or other
masonry product that complement the proposed building and site development. There shall be a
minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-
of-way. Please refer to retaining wall standards (RMC 4-4-040) for additional information about
fences and retaining walls. No fences or retaining walls were shown on the submitted materials.
Parking: Parking for vehicles, loading areas, and driveways shall be provided in accordance with
the provisions of the current parking regulations of RMC 4-4-080, “Parking, Loading, and Driveway
Regulations.” Parking requirements for uses classified as “Office, General” are to provide a
minimum of 2.0 per 1,000 square feet of net floor area and a maximum of 4.5 parking spaces per
1,000 square feet of net floor area, and for “Offices, Medical and Dental” are to provide a
minimum and maximum of five (5) spaces per 1,000 square feet of net floor area.
The applicant will be required at the time of building permit application to provide a parking
analysis of the subject site (analysis should include parking requirements for all uses on the site)
with calculations based on the requirements noted above. The analysis would include
dimensions of stalls and drive aisles.
All non-residential development that exceeds 4,000 gross sf in size would also be required to
comply with the bicycle parking requirements of RMC 4-4-080F.11. The number of bicycle parking
spaces required would be based on 10% of the required number of off-street vehicle parking
stalls. Each bicycle parking space shall be at least two feet (2') by six feet (6'), with no less than an
overhead clearance of seven feet (7'). Bicycle parking shall be conveniently located with respect
to the street right-of-way and must be within fifty feet (50') of at least one main building entrance,
as measured along the most direct pedestrian access route. Bicycle parking shall be provided for
secure extended use and shall protect the entire bicycle and its components and accessories from
theft and weather. Acceptable examples include bike lockers, bike check-in systems, in-building
parking, and limited access fenced areas with weather protection. Please review RMC 4-4-
080F.11.b-c for further general and specific bicycle parking standards. Modification of these
minimum standards requires written approval from the Department of Community and Economic
Development. An analysis demonstrating compliance with the bicycle parking standards shall be
submitted at the time of formal land use application.
Access: Driveway widths are limited by the driveway standards, in RMC 4-4080I. No changes to
access are proposed as a part of the project.
Critical Areas: According to COR Maps, the site is located within a High Seismic Hazard Area. A
geotechnical report prepared by a licensed professional may be required by the Building Official
at the time of building permit application submittal. It is the applicant’s responsibility to ascertain
if any other critical areas or environmental concerns are present on the site during site
development or building construction.
Page 5 of 5
June 17, 2021
Bloodworks Renton Donor Center and West Office TI
A special flood hazard area is also mapped on the project site. No work is proposed within the
flood hazard area, therefore it is unlikely that a flood hazard study would be required. If the scope
changes prior to formal land use submittal, a professional study may be required at staffs
discretion.
The site is mapped within the Black River/Springbrook Creek Regulated Shoreline Area, however
no work is proposed within the shoreline buffer.
Environmental Review: The proposal includes a tenant improvement that does not involve a
change of use beyond what was previously existing, therefore the proposal would be exempt from
Environmental (SEPA) Review.
Permit Requirements: The proposal would require a building permit. The City now requires
electronic plan submittal for all applications. The City’s Electronic File Standards can also be found
on the City’s website at:
https://www.rentonwa.gov/cms/ one.aspx?portalId=7922741&pageId=9666400.
Impact Mitigation Fees: Fire and transportation impact fees would be assessed based on the final
assessed use of the building. These fees would be payable prior to building permit issuance.