Loading...
HomeMy WebLinkAboutP_Street_Profiles_And_Cross_Sections_20210521_v1.pdfLENGTH= 167'-6". PER RMC 4-4-07 STREET TREES REQUIRED: 167.6/50' SPACING=3.35 STREET TREES PROVIDED: 3 LENGTH= 177'-5". PER R MC 4-4-07 STREET TREES RE QUIRED: 177.5/50=3.55STREET TREES PROVIDED: 4 PR O P E R T Y L I N E 4 8 " D EC . 4 0 D L 4 8 " D EC .40DL 32 10+00 11+00 12+00 13+00BP: 10+00.00PI: 12+85.07PT: 12+49.24PCC: 11+37.0320+0021+00B P : 2 0 + 0 0 . 0 0 EG: 31.1031 20 25 30 35 20 25 30 35 FG10+50FG 30.78FG 30.9011+00FG 30.91FG 30.7711+50FG 30.65FG 30.7712+00FG 30.77FG 30.6012+50FG 30.42FG13+00FG FG13+50FGCB # 2, TYPE 1 N: 175905.22 E: 1300687.50 RIM: 30.63 IE: 26.40 24" (NE) IE: 26.40 24" (SW) CB # 1, TYPE 1 N: 175961.47 E: 1300749.60 RIM: 30.56 IE: 26.66 24" (SW) IE: 26.66 24" (NE) CB # 3, TYPE 1 N: 175896.20 E: 1300677.01 RIM: 30.73 IE: 26.92 24" (SE) IE: 26.35 24" (SW) IE: 26.35 24" (NE) CB # 4, TYPE 1 N: 175869.82 E: 1300643.93 RIM: 30.97 IE: 26.22 24" (NE) IE: 26.22 24" (NW) EXISTING GRADE AT CENTERLINE EXISTING GRADE AT FLOW LINE EXISTING 8" STORM PROPOSED 8" WATER @ WATER CENTERLINE 84 LF 24" CPEP @ 0.31% 14 LF 24" CPEP @ 0.36% 42 LF 24" CPEP @ 0.31% 40 LF 24" CPEP @ 0.30% PROPOSED 8" WATER @ STORM CROSSING STA: 11+89.78 ELEV: 30.85 EXISTING GRADE AT EXISTING FLOWLINE PROPOSED GRADE AT PROPOSED FLOW LINE PROPOSED GRADE AT FLOWLINE WATERSHED AFFORDABLE HOUSING APARTMENTS 20200930 PRELIMINARY PLANNED URBAN DEVELOPMENT 05/21/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX below.Know what'sCallbefore you dig. R DATE: May 21, 2021 FILENAME: \\ahbl.com\data\Projects\2020\2200335\10_CIV\CAD\2200335-SH-FRNT.dwg C4.00 ---- GRADY WAY PROFILE GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N SOUTH GRADY WAY PROFILE SCALE: 1"=20' H 1"=10 V APPROX. LOCATION OF 18" WATER @ WATER CL. 1 C4.20 05/21/2021 L ENG TH = 1 6 7 ' - 6 " . P ER RMC 4 - 4 - 0 7 S TR E E T TR E E S R EQU IR ED : 1 6 7 . 6 / 5 0 ' S P AC ING = 3 . 3 5 LENGTH= 177'-5". PER RMC 4-4-07 STREET TREES REQUIRED: 177.5/50=3.55 STREET TREES PROVIDED: 4 12"CON.14DL8"CON.14DL30 31 1 3 + 0 0 PI: 12+85.07PT: 12+49.2420+00 21+00 22+00 23+00BP: 20+00.00PI: 22+11.44EG: 31.10 31 31 20 25 30 35 20 25 30 35 FG20+50FG 30.15FG 29.9021+00FG 29.64FG 29.6521+50FG 29.78FG 29.9022+00FG 30.05FG22+50FG134 LF 18" CPEP @ 0.05% -0.5% EX CB# 1, 48" TYPE 2 N: 176008.15 E: 1300784.06 RIM: 30.69 IE: 27.09 18" (NE) IE: 27.09 18" (N) IE: 27.09 12" (SW) EX CB# 2, EXISTING TYPE 1 RIM: 29.67 ADJUST RIM TO PROPOSED GRADE IE OUT: 27.46 (12"S) N: 176062.37 E: 1300764.83 EX CB# 3, 48" TYPE 2 RIM: 30.56 IE IN: 27.16 (18"S) IE OUT: 27.16 (12"W) IE OUT: 27.11 (18"N) IE OUT: 27.18 (12"E) N: 176141.75 E: 1300787.52 EX CB# 4, EXISTING TYPE 1 RIM: 29.97 IE IN: 27.41 (12"E) N: 176142.86 E: 1300765.95 PROPOSED WATER AT CENTERLINE 8" DIP EXISTING 18" WATER MAIN AT ROAD CENTERLINE APPROXIMATE EXISTING 12-INCH WATER MAIN, @ WATER MAIN CENTERLINE. EXISTING GAS SIZE UNKNOWN EXISTING GRADE AT CENTERLINE EXISTING GRADE AT EXISTING FLOWLINE -1.0% EXISTING GRADE AT EXISTING FLOWLINE PROPOSED GRADE AT PROPOSED FLOW LINE WATERSHED AFFORDABLE HOUSING APARTMENTS 20200930 PRELIMINARY PLANNED URBAN DEVELOPMENT 05/21/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX below.Know what'sCallbefore you dig. R DATE: May 21, 2021 FILENAME: \\ahbl.com\data\Projects\2020\2200335\10_CIV\CAD\2200335-SH-FRNT.dwg C4.10 ---- WILLIAMS AVE PROFILE GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 NSOUTH GRADY WAY PROFILE SCALE: 1"=20' H 1"=2' V PROPOSED GRADE AT FLOWLINE 2 C4.20 B B 05/21/2021 -1.5%1:12 MAX -2.1% 8.0' PROPOSED AMENITY STRIP 8.0' ROW DEDICATION ℄SOUTH GRADY WAY40.8' 48.8' EXISTING ROW LINE PROPOSED ROW LINE PROPOSED BUILDING EDGE CURB AND GUTTER PER COR STD PLAN 103 EXISTING GRADE 8.0' CEMENT CONCRETE SIDEWALK PER COR STD PLAN 102. SURFACING PER LANDSCAPING ℄WILLIAMS AVENUE SOUTHEXISTING ROW LINE PROPOSED ROW LINE 5.0' ROW DEDICATION PROPOSED BUILDING EDGE 12.0' CEMENT CONCRETE SIDEWALK PER COR STD PLAN 102. CURB AND GUTTER PER COR STD PLAN 103 EXISTING GRADE PROPOSED GRADE 30.0' 35.0' -3.3% SURFACING PER LANDSCAPING 1.0' WATERSHED AFFORDABLE HOUSING APARTMENTS 20200930 PRELIMINARY PLANNED URBAN DEVELOPMENT 05/21/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX below.Know what'sCallbefore you dig. R DATE: May 21, 2021 FILENAME: \\ahbl.com\data\Projects\2020\2200335\10_CIV\CAD\2200335-SH-FRNT.dwg C4.20 ---- STREET SECTIONS 1 SCALE: 1"=5' H SOUTH GRADY WAY SECTION 2 SCALE: 1"=5'H WILLIAMS AVENUE SOUTH SECTION HMA CL 1 2" PG 64-22, MATCH EXISTING THICKNESS, NO LESS THAN 6-INCHES. 6-INCHES CRUSHED SURFACING TOP COURSE. PAVEMENT SECTION PER STD PLAN 110.1. HMA CL 1 2" PG 64-22, MATCH EXISTING THICKNESS, NO LESS THAN 6-INCHES. 6-INCHES CRUSHED SURFACING TOP COURSE. PAVEMENT SECTION PER STD PLAN 110.1. 05/21/2021