Loading...
HomeMy WebLinkAboutR-4137316 1 C) 1 W 3 \-YELLOW N0. 33538 SKIP CENTER LINE 6 YELLOW OR WHITE PER PLAN All nr I Inlr 4 WHITE NO. 37925 PEDESTRIAN AND PARKING LINE NOTE: PAINT MARKINGS PER FAA STANDARDS. LONGITUDINAL PAVEMENT MARKING DETAILS SCALE: NOT TO SCALE PED MAN LAYOUT SHALL ALTERNATE AS SHOWN 4" PAINTED WHITE EDGE LINE i el 3EE PLAN DINT PER BOEING DECIFICATIONS C503 I C226-C228 4"$1 r L F �„ WHITE PAINT L —0 PEDESTRIAN PATHWAY SYMBOL * PEDESTRIAN PATH *PED PATH WIDTH 4FT-6FT INTERIOR 4FT-8FT EXTERIOR NOTE: CENTER PED SYMBOL BETWEEN STRIPES WHEN NO FENCE IS PRESENT. CENTER PED SYMBOL BETWEEN FENCE AND STRIPE WHEN FENCE IS PRESENT. P ED ESTR AN PATHWAY MARKING DETAILS SCALE: NONE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 737 MAX FLIGHTLINE UTILITIES —APRON A CI PROJECT RT TWN 04.13.16 — APRON A CI PROJECT — SITE DCN-06 RT TWN 09.27.16 — CITY OF RENTON PERMIT REVIEW COMMENTS RT TWN 05.23.16 — RECORD DRAWING — 737 MAX FLIGHTLINE UTILITIES RT TWN 10.28.16 — APRON A CI PROJECT — SITE DCN-01 RT TWN 06.13.16 — APRON A SITE STORMWATER IMPROVEMENTS-30% RT TWN 01.17.18 — APRON A CI PROJECT — SITE DCN-02 RT TWN 07.19.16 — APRON A SITE STORMWATER IMPROVEMENTS-60% TO IFC RT TWN 07.14.20 — APRON A CI PROJECT — SITE DCN-03 RT TWN 08.05.16 — APRON A SITE STORMWATER REVISIONS PER CITY COMMENTS RT TWN 09.29.20 C5031C226-C228 Q� BOE/NG` ri- NAL WWII RED VI\ WHITE PAINT \VLVVI\YY I.JL JL UI\ \J\UIVI I\ IJL I LU\I\YY I.J , VI I ,.,SITE TO DIRECTION OF ADJACENT VEHICULAR TRAFFIC) NO PARKING STRIPING SCALE: NONE CENTER CENTER IN IN LANE LANE 10 ii �6"MIN.(TYP.) 24 8"(TYP.)—STRIP 8"(TYP.)—OPEN LANE (TYP.) LANE 8"(TYP.)—STRIPE CONCRETE LINE GUTTER LINE 1 TRACKS—) TRACKS —)TRACKS./ TRACKS * TYPICAL 4-LANE ROADWAY CONFIGURATION * NOTE: FOR ROADWAYS WITH MORE OR LESS LANES, THE SAME CONFIGURATION APPLIES. KEEPING THE THERMOPLASTIC/PAINTED BARS CENTERED ON THE LANE LINES AND IN THE CENTER OF TRAVELLED PORTION OF THE LANE TO MINIMIZE THE WEAR ON THE THERMOPLASTIC/PAINT. _ + PUBLIC WORKS THERMOPLASTIC/PAINTED ROVE P 27 DEPARTMENT CROSSWALK o T THERMOPLASTIC CROSSWALK DETAILS SCALE: NOT TO SCALE C503 I C226-C228 C503 C226-C228 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED R. TEMPLADO CHECKED T. NEU ENGINEER T. NEU APPROVED BY DEPT. DATE CHECKED D. MURATA APPROVED ATE SUBTITLE 09.29.20 09.29.20 TITLE 09.29.20 09.29.20 R-413731 PAVEMENT MARKING DETAILS APRON A -SITE STORMWATER IMPROVEMENTS (STALLS A3-A7 CIVIL MASTER SITE 05-YD PERMIT SUBMITTAL DESIGN BY DOWL RENTON, Wq I °wc No. ItDOWL W5184605 C503 DATE 09.29.20 05-APRON-A-0503 09.29.20 C28