Loading...
HomeMy WebLinkAboutExhibit_7_Advisory_NotesDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 6 LUA21-000168 ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Alex Morganroth, 425-430-7219, amorganroth@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division’s approval of this work is required prior to final inspection and approval of the permit. 4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is being cleared. 5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. 6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. 7. This permit is shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and /or your U.S. Fish and Wildlife Service permit. Development Engineering: (Contact: Brianne Bannwarth, 425-430-7299,bbannwarth@rentonwa.gov) 1. See Attached Development Engineering Memo dated June 4, 2021 Fire Authority: (Contact: Corey Thomas, 425-430-7024, cthomas@rentonrfa.gov) Environmental Impact Comments: DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089 ADVISORY NOTES TO APPLICANT Page 2 of 6 LUA21-000143 1. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. No charge for the retention of the existing home. Code Related Comments: 1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed building and two hydrants if the fire flow goes up to 1,500 gpm. There is one existing hydrant within 300-feet. A water availability certificate shall be obtained from Cedar River Water District. 2. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Dead end streets are limited to 700-feet maximum, due to extreme length of the dead- end street, the Renton Fire Authority would not normally support a new plat at this location. The applicant has requested and a variance has been approved to provide the new home with an approved fire sprinkler system in lieu of the normal fire apparatus access requirements. Community Services: (Contact: Leslie Betlach, 425-430-6619, lbetlach@rentonwa.gov) 1. Parks Impact fee per Ordinance 5670 applies. Exhibit 7DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089 ADVISORY NOTES TO APPLICANT Page 3 of 6 LUA21-000143 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: June 14, 2021 TO: Alex Morganroth, Senior Planner FROM: Brianne Bannwarth, Civil Plan Reviewer SUBJECT: Utility and Transportation Comments for Sandhu Short Plat 13952 SE 159th Place LUA 21-000143 I have reviewed the application for the Error! Reference source not found. at 13952 SE 159th Place (APN 2223059022) and have the following comments: EXISTING CONDITIONS The site is approximately 0.65 acres in size and is rectangular in shape. “An existing, two-story single-family residence with a basement that daylights to the north is present at the eastern portion of the site. The existing residence has an attached three-car garage located at the southeast side of the existing residence. An accessory building or detached garage is located at the middle of the west side of the site. A paved loop driveway is present at the central portion of the site to provide vehicular access to the attached 3-car garage and the detached garage with access at two locations along SE 159th Place. The driveway is paved with asphalt concrete closest to the SE 159th Place and Portland concrete cement between the two garages. Concrete stairs are located west of the existing residence.” (Otto Rosenau & Associates, Inc., Geotechnical Report, June 25, 2019) Water Water service is provided by Cedar River Water and Sewer District. Sewer Wastewater service is provided by the Cedar River Water and Sewer District. Storm There is an existing storm drainage system in SE 159th Place. The existing property does not contain stormwater facilities. Runoff from the existing site includes roof downspouts from the single-family residences where no stormwater infrastructure currently exists on-site. Runoff from the site sheet flows north into top the adjacent properties. Streets SE 159th Place is a Residential Street with an existing right of way (ROW) width of 48 feet as measured using the King County Assessor’s Map. The existing roadway is a paved width of 28-foot with a rolled curb and a 5-foot sidewalk on either side of the roadway. DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089 ADVISORY NOTES TO APPLICANT Page 4 of 6 LUA21-000143 DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089 ADVISORY NOTES TO APPLICANT Page 5 of 6 LUA21-000143 CODE REQUIREMENTS WATER 1. A water availability certificate from Cedar River Water and Sewer District has been provided and the project is able to be serviced by the District. SEWER 1. A sewer availability certificate from Cedar River Water and Sewer District has been provided and the project is able to be serviced by the District. SURFACE WATER 1. A geotechnical report, dated June 25, 2019, completed by Otto Rosenau & Associates, Inc. for the site has been provided. The submitted report describes the site is a Low Erosion Hazard area of the till soils on site. Erosion control measures will need to be in place prior to starting grading activities on the site. The report discusses the soil and groundwater characteristics of the site including a measured infiltration rate of 1.25 inches per hour on the south side of the western lot and it provided recommendations for project design and construction. Geotechnical recommendations presented need to be address within the project plans. 2. A Storm Drainage Report was not submitted with the land use application. Based on the City of Renton’s flow control map, the site falls within the Flow Control Duration Standard area matching Forested Site Conditions and is within the Lower Cedar River Drainage Basin. The development is anticipated to trigger Simplified Drainage Review based on the addition of one new single-family lot in accordance with the 2016 City of Renton Surface Water Design Manual (RSWDM). All core requirements and the six special requirements must be discussed in the storm drainage report/assessment. It does appear that Onsite BMPs will be able to be addressed on site to mitigate for the impervious area added on the new lot. Note: If new/replaced effective impervious area exceeds 5,000 square feet, directed drainage review may be required. 3. A Construction Stormwater General Permit from Department of Ecology will be required if grading and clearing of the site exceeds one acre. A Stormwater Pollution Prevention Plan (SWPPP) is required for this site. Currently the site does not appear to trigger this requirement. 4. A surface water development fee of $2,000.00 per new single-family residence will apply. This is subject to final design and payable prior to issuance of the storm water utility permit. TRANSPORTATION 1. The proposed development fronts SE 159th Place along the south property lines. SE 159th Place is a Residential Street with an existing right of way (ROW) width of 48 feet as measured using the King County Assessor’s Map. The existing roadway is a paved width of 28-foot with a rolled curb and a 5-foot sidewalk on either side of the roadway. To meet the City’s complete street standards for residential street, minimum right of way width is 53 feet. Dedication of 2.5 feet of right of way would be required. The applicant has requested a street modification to modify the ROW width and street cross section match the existing improvements. City Staff has reviewed the requested modification and will support the modification to match the established standard street section for SE 159th Place since it is within an established neighborhood, provides safe access for pedestrians and vehicles. DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089 ADVISORY NOTES TO APPLICANT Page 6 of 6 LUA21-000143 2. Current City standards require a turnaround for dead-end streets greater than 150 feet. Dead-end streets up to 300 feet may utilize a hammerhead turnaround provided it meets the requirements for emergency services access, including a 25-ft inside and 45-ft outside turning radius. Dead end streets are limited to 700-feet maximum. Reference RMC 4-6-060H. This project does not have the required fire apparatus access; however, the Renton Regional Fire Authority will support the installation of a fire sprinkler system in lieu of providing the required fire apparatus access. 3. The proposed subdivision is anticipated to create one additional PM Peak Hour Vehicle Trip for the new additional single-family lot. It is not anticipated to adversely impact the City’s transportation system. 4. Refer to City code 4-4-080 regarding driveway regulations. Driveways shall be designed in accordance with City standard plans 104.1 and 104.2. 5. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 6. The current rate of transportation impact fee is $10,861.69 per dwelling unit for single family homes. The transportation impact fee that is current at the time of building permit application will be levied. Traffic impact fees will be owed at the time of building permit issuance. GENERAL COMMENTS 1. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements (if applicable). a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required except for water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 2. If the street modification is approved with the land use application, all public works permits can be obtained concurrently with the building permit for the house on the property. 3. All utility lines (i.e. electrical, phone, and cable services, etc.) serving the proposed development must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 4. Fees quoted in this document reflect the fees applicable in the year 2021 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. DocuSign Envelope ID: 31A7AF34-3202-4862-8D19-13E93B7C6089