HomeMy WebLinkAboutEx 13_Tree Retention Plan.pdfDUVALL AVE. NE
CHELAN AVE. NE
NE 12TH ST.WETLAND
TREE DENSITY CALCULATIONS
AS PER THE CITY OF RENTON TREE DENSITY REQUIREMENT (RMC 4-4-130.H.1), THE REQUIRED MINIMUM TREE
DENSITY IS 2 SIGNIFICANT TREES PER 5,000 SF.
PROJECT SITE: 484,329 SF
PROJECT TREE CREDITS REQUIRED (484329 / 5000): 97
PROJECT TREE CREDITS PROVIDED (18 EX. SIGNIF. TREES TO REMAIN + 114 REPLACEMENT TREES): 132
(SYMBOLS SHOWN AT 1"=20'-0" SCALE)TREE SCHEDULE
DESCRIPTIONSYMBOL
EXISTING TREES
EXISTING LANDMARK CONIFEROUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY)
EXISTING LANDMARK DECIDUOUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY)
EXISTING EVERGREEN TREE TO REMAIN
EXISTING DECIDUOUS TREE TO REMAIN
EXISTING NON SIGNIFICANT CONIFEROUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SIZE)
EXISTING NON SIGNIFICANT DECIDUOUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SIZE)
TREE RETENTION CALCULATIONS
AS PER THE CITY OF RENTON TREE RETENTION REQUIREMENT (RMC 4-4-130.H.1), THE PERCENTAGE OF TREES TO
BE RETAINED IS AT LEAST 30% OF THE SIGNIFICANT TREES IN R-8 ZONES.
TOTAL # SIGNIFICANT TREES (OVER 6" DIAMETER, OR ALDER /COTTONWOOD AT LEAST 8" DIA.): 499
TOTAL # EXCLUDED TREES (TREES IN CRITICAL AREAS / BUFFERS & PROPOSED PUBLIC STREETS): 228
SUBTOTAL TREES TO BE COUNTED (499 - 228): 271
REQUIRED # TO BE RETAINED (271 * 0.3): (81.3) 82
TOTAL # SIGNIFICANT TREES PROPOSED TO BE RETAINED: 18
PERCENTAGE OF TREES TO REMAIN (18 / 271): (6.66) 7%
# REQUIRED REPLACEMENT INCHES (81.3 - 18 * 12): (759.6) 760
# REPLACEMENT TREES REQUIRED (MIN. 2" CALIPER TREES REQUIRED FOR REPLACEMENT)
(759.6 / 2): (379.8) 380
30" EVG
30" DEC
30" DEC
30" EVG
5" DEC
5" EVG
EXISTING SIGNIFICANT CONIFEROUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY)
EXISTING SIGNIFICANT DECIDUOUS TREE TO BE REMOVED
(DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY)8" DEC
8" EVG
REPLACEMENT TREES
MIN. 2" CAL. DECIDUOUS REPLACEMENT TREE
MIN. 6' HT. EVERGREEN REPLACEMENT TREE
EXCLUDED SITE AREA - CRITICAL AREA (WETLAND) AND 100' BUFFER
QTY
127,685 SF
9
9
29
5
204
67
15
22
82
52
NON SIGNIFICANT TREES TO BE REMOVED SUBTOTAL 37
SIGNIFICANT TREES TO BE REMOVED SUBTOTAL 271
LANDMARK TREES TO BE REMOVED SUBTOTAL 34
EXISTING TREES TO REMAIN SUBTOTAL 18
1.SEE CIVIL GRADING PLANS FOR TREE PROTECTION FENCING. ALL TREE RETENTION, PROTECTION AND
CLEARING ACTIVITIES SHALL BE IN ACCORDANCE WITH RENTON MUNICIPAL CODE (RMC) 4-4-130 TREE
RETENTION AND LAND CLEARING REGULATIONS.
2.PRIOR TO DEVELOPMENT ACTIVITIES, THE CONTRACTOR SHALL PROVIDE TREE PROTECTION MEASURES IN
ACCORDANCE WITH RMC 4 4 130H FOR ALL EXISTING TREES SHOWN TO BE SAVED.
3.A CERTIFIED ARBORIST OR LANDSCAPE ARCHITECT SHALL MONITOR THE CONSTRUCTION ACTIVITIES THAT ARE
NECESSARY WITHIN THE TREE DRIPLINES.
4.WRITTEN NEED FOR REMOVAL OR REVISED LANDSCAPE AND CLEARING/ GRADING PLANS SHALL BE REVIEWED
AND APPROVED BY CURRENT PLANNING PROJECT MANAGER PRIOR TO CONSTRUCTION PERMIT APPROVAL.
REPLACEMENT TREE SUBTOTAL 114
*TREES IN PROPOSED PUBLIC STREETS -20
TREE RETENTION NOTES
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ANDR E W J R ASM
U
S
SENNO.
739 EXP.6 /2 6 /2021STATE O F W A SHI
N
GTONLANDS
C
AP E A R C H ITECT0'
SCALE:N200'100'50'25'
1"=50'-0"
NEW ELEMENTARY SCHOOL #16
CHELAN AVE NE
RENTON, WA 98059
TREE RETENTION
OVERALL PLAN
NOTE: REFER TO L0.1 FOR TREE RETENTION
WORKSHEET AND TREE PROTECTION DETAIL.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ANDR E W J R ASM
U
S
SENNO.
739 EXP.6 /2 6 /2021STATE O F W A SHI
N
GTONLANDS
C
AP E A R C H ITECTNEW ELEMENTARY SCHOOL #16
CHELAN AVE NE
RENTON, WA 98059
TREE RETENTION
WORKSHEET & DETAIL
TREE PROTECTION NOTES:
EXISTING TREE INDICATED
TO SAVE OR POTENTIALLY
TO SAVE.
1. A 6-FOOT HIGH TEMPORARY CHAIN LINK FENCE
MUST BE PLACED WHERE SHOWN ON PLANS A MINIMUM OF FOUR BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF WORK
OR SITE DEMOLITION. VERIFY LOCATIONS WITH CIVIL. NOTIFY THE CLEARING AND GRADING INSPECTOR TO GET BOTH THE
INSPECTION AND WRITTEN APPROVAL OF FLAGGED TREES AND TEMPORARY PROTECTION FENCING AROUND TREES TO BE
SAVED PER THE APPROVED PLANS.
2. NO STOCKPILING OF MATERIAL AND NO VEHICULAR TRAFFIC ARE ALLOWED WITHIN THE
LIMITS OF THE TEMPORARY FENCING. LIMIT INTRUSION INTO TREE DRIP ZONES WHEN POSSIBLE. FILLING, EXCAVATING, AND
CLEARING WITHIN FENCED AREAS MUST BE ACCOMPLISHED BY HAND METHODS ONLY.
3. ROOTS OF TREES TO BE SAVED WHICH ARE DAMAGED DURING CONSTRUCTION WILL BE
TREATED IN THE FOLLOWING WAY:
FOR DAMAGED ROOTS OVER 1'' IN DIAMETER, MAKE A CLEAN, STRAIGHT CUT TO REMOVE THE DAMAGED PORTION OF THE
ROOT. ALL EXPOSED ROOTS WILL BE TEMPORARILY COVERED WITH DAMP BURLAP OR WOOD SHAVING TO PREVENT DRYING
AND COVERED WITH EARTH AS SOON AS POSSIBLE.
4. PER RMC 4-4-130-H.9.f, ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A
MINIMUM OF THREE INCHES (3") OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING.
RESTRICTIONS:
TREES TO BE PRESERVED SHALL BE DESIGNATED IN ACCORDANCE WITH
APPROVED TREE PRESERVATION PLAN ON FILE WITH THE CITY OF RENTON.
DESIGNATED TREES WHICH ARE DAMAGED OR DESTROYED SHALL BE
REPLACED IN ACCORDANCE WITH RMC 4-4-130 TREE RETENTION AND LAND
CLEARING REGULATIONS, OR AS HEREAFTER AMENDED.
TREE PROTECTION DETAIL
16'-0'' CHAIN LINK ORSAFETY FENCING4' ORANGE LAMINAR