HomeMy WebLinkAboutEx 28_Electrical Plan.pdfADCBADCBADCBADCBADCBDUVALL AVE. NECHELAN AVE. NENE 12TH ST.CHELAN PL. NESmart Play®(5-12 years)Max Fall Height: 87 inchesGENERATORBACKUPFUEL TANKUTILITYTRANSFORMER& VAULTE7.0114"C - UTILITY PRIMARYFURNISHED BY UTILITYINSTALLED BY CONTRACTOR(E) UTILITY POLE W/ (E)POLE-MOUNT XFMR(E) UTILITY POLE W/(E) POLE-MOUNTXFMR(E) UTILITY POLE W/(E) POLE-MOUNTXFMR(E) OVERHEADSERVICE LATERAL -POWER & TV(E) UTILITY POLE(E) OVERHEADSERVICE LATERAL -POWER(E)WEATHERHEAD(E) STREETLUMINAIRE (TYP OF 2)(E) STREETLUMINIARE MOUNTEDTO UTILITY POLE(E) STREET LIGHTINGPEDESTAL(E) 37.5 KVA PAD-MOUNTEDUTILITY TRANSFORMER(E) TV PEDESTAL(E) TELEPHONE PEDESTAL(E) UTILITY POLE(E) STREETLUMINIARE MOUNTEDTO UTILITY POLE(E) STREETLUMINAIRE (TYP OF 2)(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITY POLE(E) STREETLUMINAIRE (TYP OF 3)(E) STREET LIGHTINGHANDHOLE (TYP)(E) STREET LIGHTINGPEDESTAL(E) TELEPHONEPEDESTAL(E) SIGNALIZATIONPEDESTAL(E) STREET LIGHTINGPEDESTAL(E) UTILITY POWERMETER(E) SCHOOL SPEEDLIMIT SIGN WITHFLASHER(E) TELEPHONEPEDESTAL(E) TELEPHONEPEDESTAL(E) CATV AND PHONESERVICE AERIAL CABLINGTO REMAIN(E) OVERHEADSERVICE - CATVUTILITY JUNCTION VAULTFURNISHED BY UTILITYINSTALLED BY CONTRACTOR (1) 4"C - FURNISHED BYUTILITY INSTALLED BYCONTRACTORNEW THREE-PHASEOVERHEAD UTILITYDISTRIBUTION BY PSEE1E1E1E1E1E1E1E1E1E1E1E2E2E2 E2E2SL1SL125' STREET LIGHTING LUMINAIREPER CITY OF RENTONSTANDARDS (TYP OF 3)FGFGFGFGFG(2) 2-1/2"C - POWER(1) 2"C - FIRE ALARMV4V4(2) 1"C - FUTURE EVCHARGING STATIONS(1) 2"C - READERBOARDV3READERBOARDV5V5 #8 AWG, 2"CV5 #8 AWG, 2"CFAAPFAAPFACPGENERATORMANUALTRANSFERSWITCHNEW RENTONELEMENTARYSCHOOL #1625' PARKINGSCALELUMINAIRE(TYP)12' PEDESTRIAN SCALELUMINAIRE (TYP)1(E) SERVICE1(E) SERVICE1222124"C - UTILITY PRIMARYFURNISHED BY UTILITYINSTALLED BY CONTRACTOR(E) SERVICE12(E) SERVICE12FUTURE EVCHARGINGSTATIONSFUTUREPORTABLESE2FGV3V3(1) 1"C - LIGHTING(1) 1"C - POWER333333333(N) 2" CONDUIT RISERFURNISHED AND INSTALLED BYUTILITY4(N) UTILITY POLE WITH (E)POLE-TOP TRANSFORMERAND (N) CONDUIT RISERSFURNISHED AND INSTALLEDBY UTILITYNEW THREE-PHASEOVERHEAD UTILITYDISTRIBUTION BY PSE12(1) 2"C - POWERE1E1E1E1E1E1E2FGE2E2FG(1) 1"C - LIGHTINGV333FLAG NOTES:COORDINATE RECONNECTION OF EXISTING SERVICES TOREMAIN FROM DEMOLISHED UTILITY POLE TO BE FED FROM NEWRELOCATED POLE-TOP TRANSFORMER/UTILITY PRIMARY.NEW CONDUCTORS PROVIDED BY PSE TO RECONNECT EXISTINGSERVICES TO REMAIN.PROVIDE (2) 1"C TO SITE LIGHTING LUMINAIRE INDICATED, (1) FORLIGHTING CIRCUIT AND (1) FOR FUTURE CAMERA POWER.UTILITY SHALL PROVIDE REFEED OF PRIMARY SIDE OF EXISTINGPOLE-TOP TRANSFORMER.1VAULT SCHEDULEVAULT TYPEMANUFACTURERVAULT MODELCOVER MODELCOVER RATINGCOVER LABELVAULT DIMENSIONSNOTES(L X W X D)V1V2OLDCASTLE444-BL44-332PMEDIUM DUTY: H-20 OFF STREET4'-0" X 4'-0" X 4'-0"V3OLDCASTLEB1324 BOXN1324-51JHHEAVY DUTY: H-20 ROADWAYELECTRIC29-1/2" X 18-3/4" X 12"V4OLDCASTLE233-BL23-2436PMEDIUM DUTY: H-20 OFF STREETELECTRIC3'-8" X 2'-8" X 3'-6"V5OLDCASTLETYPE-1-MEDIUM DUTY: H-20 OFF STREETLT22"X17"X12"1NOTES1.COORDINATE WITH CITY OF RENTON REQUIREMENTS STANDARDS 119,120.2.3.234SHEET NOTES:1.REFER TO CIVIL, LANDSCAPE AND SURVEY DRAWINGS FOR ADDITIONAL INFORMATION.2.COORDINATE PLACEMENT OF SITE LIGHTING, VAULTS AND RACEWAY WITH DIVISION 31, CIVIL AND DIVISION 32,LANDSCAPE CONTRACTORS. COORDINATE WITH TREE PROTECTION PLANS AND AVOID CRITICAL ROOT ZONES OFEXISTING TREES. CONFLICTS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TOCOMMENCEMENT OF SITE WORK.3.COORDINATE ELECTRICAL UTILITY SERVICE AND OFF-SITE UTILITY ELECTRICAL WORK WITH PUGET SOUND ENERGYPRIOR TO COMMENCING WORK. INSTALLATION SHALL COMPLY WITH POWER COMPANY'S ELECTRICAL INSTALLATIONREQUIREMENTS. CONTACT TIN NGUYEN WITH PUGET SOUND ENERGY AT 253-244-4303, TIN.NGUYEN@PSE.COM FORADDITIONAL REQUIREMENTS.4.MINIMUM CONDUIT SIZE SHALL BE 1 INCH. MINIMUM CONDUCTOR SIZE SHALL BE #10 AWG FOR BRANCH CIRCUIT WORKSHOWN ON THIS SHEET.5.PROVIDE #8 AWG CONDUCTORS FOR LIGHTING BRANCH CIRCUIT WORK SHOWN ON THIS SHEET.6.PROVIDE A WATER-TIGHT SEAL FOR EACH UNDERGROUND RACEWAY ENTERING THE ELECTRICAL ROOM AFTERCONDUCTORS HAVE BEEN INSTALLED. REFER TO RACEWAY SPECIFICATION SECTION 260533 FOR ADDITIONALINFORMATION.7.REFER TO ONE-LINE DIAGRAM ON SHEET E9.01 FOR ADDITIONAL INFORMATION.8.ROUTE SITE LIGHTING CIRCUITS TO PANELS INDICATED VIA ASSOCIATED LIGHTING CONTROL PANELS. REFER TO E2SERIES DRAWINGS FOR SITE LIGHTING CONTROL REQUIREMENTS. PROVIDE WIRING AND CONTROL DEVICES REQUIREDFOR COMPLETE SYSTEM.9.INSTALL UNDERGROUND CONDUIT PER TRENCHING DETAIL. REFER TO DETAIL 3, SHEET E7.03.10.PROVIDE CONCRETE BASE FOR SITE LIGHTING POLES. REFER TO DETAILS 1 AND 2, SHEET E7.03 FOR ADDITIONALINFORMATION.11.REFER TO VAULT SCHEDULE ON THIS SHEET FOR VAULT AND HANDHOLE TYPES. REFER TO SPECIFICATIONSECTION 260543 FOR ADDITIONAL INFORMATION.12.SEE STREET LIGHTING DETAILS ON SHEET E7.04 FOR ADDITIONAL INFORMATION.4010 LAKE WASHINGTON BLVD NESUITE 320KIRKLAND, WA 98033425.828.8948HOARCH.COMPROJECT INFORMATIONCONSULTANT STAMPARCHITECT STAMPSCHOOL DISTRICT LOGOPROJECT NUMBER:SHEET NAMESHEET NUMBERNewElementaryNo. 16Duvall Avenue NERenton, WA 98059RENTON SCHOOL DISTRICTNO. 40311.4.2020SCHEMATIC DESIGN1.21.202150% DESIGN DEVELOPMENT50% DESIGNDEVELOPMENT1.21.20212014PRELIM INARY KB MH BHELECTRICAL SITE PLAN1SCALE: 1" = 40'-0"RONHTE1.00ElectricalSite Plan03.24.2021School #16Conditional UsePermit