HomeMy WebLinkAboutEx04_Architectural_ElevationsA7.0
Exterior Elevations
Renton, WA 98057
425-271-0082 (office)
425-988-0112 (fax)
www.cwdesigninc.com
P.O. Box 476
Project No:
Drawn By:
Date:
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALLHAVE PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE
CONSTRUCTION PHASE. IT IS THE CONTRACTORS
RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES
TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED.
CW DESIGN, INC MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND/OR
CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH
VARIATION(S) SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH ANY WORK,OR THE CONTRACTOR
SHALL ACCEPT FULL RESPONSIBILTY FOR COST TO
RECTIFY SAME. IN THE EVENT ANY LIABILITY IS
IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU
AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE
FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGS
PRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THE
CONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW
DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS.
Copyright 2019
CW Design, IncC
Status:
Scale:
Sheet Name:
No.Remarks Date
- Submittal Set
WJB
1
2
3
4
5
6
7
8
9 SapphireHomes-TalbotTownhomesLots13-14-15(Bldg'F')Renton,WA19041
July 16, 2021
Submittal Set
12/27/20
City Comments 04/27/21
Mod Request 07/16/21
--
--
--
--
--
--
--
1/4"=1'-0"
NORTH ELEVATION
EXTERIOR ELEVATION NOTES
CAULK ALL EXTERIOR JOINTS AND PENETRATIONS
BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS,
BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THESE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND. ADDRESS
NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH
A MINIMUM STROKE WIDTH OF 1/2 INCH. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE
BUILDING ADDRESS CANNOT BE VIEWED FROM THE
PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR
MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE
(IRC SECTION R319.1)
SURFACE DRAINAGE SHALL BE DIVERTED TO AN
APPROVED POINT OF COLLECTION SO AS TO NOT
CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS. THE GRADE AWAY FROM FOUNDATION WALLS
SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST
10 FEET. WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN
10 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED
TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
IMPERVIOUS SURFACES WITHIN 10 FEET OF THE
BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
2 PERCENT AWAY FROM THE BUILDING (IRC SECTION
R401.3)
APPROVED CORROSION-RESISTANT FLASHING SHALL BE
APPLIED SHINGLE-FASHION IN SUCH A MANNER TO
PREVENT ENTRY OF WATER INTO WALL CAVITY OR
PENETRATION OF WATER TO THE BUILDING
STRUCTURAL FRAMING COMPONENTS. THE FLASHING
SHALL EXTEND TO THE SURFACE OF THE EXTERIOR
WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE
FOLLOWING LOCATIONS: 1) EXTERIOR WINDOW AND
DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW
AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE
WATER-RESISTIVE BARRIER FOR SUBSEQUENT
DRAINAGE. 2) AT THE INTERSECTION OF CHIMNEYS OR
OTHER MASONRY CONSTRUCTION WITH FRAME OR
STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES
UNDER STUCCO COPINGS. 3) UNDER AND AT THE ENDS
OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4)
CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5)
WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH
TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME
CONSTRUCTION. 6) AT WALL AND ROOF INTERSECTIONS.
7) AT BUILT-IN GUTTERS (IRC SECTION R703.8)
WEST ELEVATION
EXHIBIT 4
RECEIVED
Clark Close 07/16/2021
PLANNING DIVISION
DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E
A7.1
Exterior Elevations
Renton, WA 98057
425-271-0082 (office)
425-988-0112 (fax)
www.cwdesigninc.com
P.O. Box 476
Project No:
Drawn By:
Date:
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALLHAVE PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE
CONSTRUCTION PHASE. IT IS THE CONTRACTORS
RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES
TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED.
CW DESIGN, INC MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND/OR
CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH
VARIATION(S) SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH ANY WORK,OR THE CONTRACTOR
SHALL ACCEPT FULL RESPONSIBILTY FOR COST TO
RECTIFY SAME. IN THE EVENT ANY LIABILITY IS
IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU
AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE
FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGS
PRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THE
CONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW
DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS.
Copyright 2019
CW Design, IncC
Status:
Scale:
Sheet Name:
No.Remarks Date
- Submittal Set
WJB
1
2
3
4
5
6
7
8
9 SapphireHomes-TalbotTownhomesLots13-14-15(Bldg'F')Renton,WA19041
Apr 27, 2021
Submittal Set
12/27/20
City Comments 04/27/21
--
--
--
--
--
--
--
--
1/4"=1'-0"
SOUTH ELEVATION
EXTERIOR ELEVATION NOTES
CAULK ALL EXTERIOR JOINTS AND PENETRATIONS
BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS,
BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THESE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND. ADDRESS
NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH
A MINIMUM STROKE WIDTH OF 1/2 INCH. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE
BUILDING ADDRESS CANNOT BE VIEWED FROM THE
PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR
MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE
(IRC SECTION R319.1)
SURFACE DRAINAGE SHALL BE DIVERTED TO AN
APPROVED POINT OF COLLECTION SO AS TO NOT
CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS. THE GRADE AWAY FROM FOUNDATION WALLS
SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST
10 FEET. WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN
10 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED
TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
IMPERVIOUS SURFACES WITHIN 10 FEET OF THE
BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
2 PERCENT AWAY FROM THE BUILDING (IRC SECTION
R401.3)
APPROVED CORROSION-RESISTANT FLASHING SHALL BE
APPLIED SHINGLE-FASHION IN SUCH A MANNER TO
PREVENT ENTRY OF WATER INTO WALL CAVITY OR
PENETRATION OF WATER TO THE BUILDING
STRUCTURAL FRAMING COMPONENTS. THE FLASHING
SHALL EXTEND TO THE SURFACE OF THE EXTERIOR
WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE
FOLLOWING LOCATIONS: 1) EXTERIOR WINDOW AND
DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW
AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE
WATER-RESISTIVE BARRIER FOR SUBSEQUENT
DRAINAGE. 2) AT THE INTERSECTION OF CHIMNEYS OR
OTHER MASONRY CONSTRUCTION WITH FRAME OR
STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES
UNDER STUCCO COPINGS. 3) UNDER AND AT THE ENDS
OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4)
CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5)
WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH
TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME
CONSTRUCTION. 6) AT WALL AND ROOF INTERSECTIONS.
7) AT BUILT-IN GUTTERS (IRC SECTION R703.8)
EAST ELEVATION
DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E
A7.0
Exterior Elevations
Renton, WA 98057
425-271-0082 (office)
425-988-0112 (fax)
www.cwdesigninc.com
P.O. Box 476
Project No:
Drawn By:
Date:
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALLHAVE PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE
CONSTRUCTION PHASE. IT IS THE CONTRACTORS
RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES
TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED.
CW DESIGN, INC MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND/OR
CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH
VARIATION(S) SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH ANY WORK,OR THE CONTRACTOR
SHALL ACCEPT FULL RESPONSIBILTY FOR COST TO
RECTIFY SAME. IN THE EVENT ANY LIABILITY IS
IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU
AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE
FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGS
PRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THE
CONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW
DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS.
Copyright 2019
CW Design, IncC
Status:
Scale:
Sheet Name:
No.Remarks Date
- Submittal Set
WJB
1
2
3
4
5
6
7
8
9 SapphireHomes-TalbotTownhomesLots16-17-18(Bldg'G')Renton,WA19042
Apr 20, 2021
Submittal Set
12/27/20
City Comments 04/20/21
--
--
--
--
--
--
--
--
1/4"=1'-0"
SOUTH ELEVATION
EXTERIOR ELEVATION NOTES
CAULK ALL EXTERIOR JOINTS AND PENETRATIONS
BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS,
BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THESE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND. ADDRESS
NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH
A MINIMUM STROKE WIDTH OF 1/2 INCH. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE
BUILDING ADDRESS CANNOT BE VIEWED FROM THE
PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR
MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE
(IRC SECTION R319.1)
SURFACE DRAINAGE SHALL BE DIVERTED TO AN
APPROVED POINT OF COLLECTION SO AS TO NOT
CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS. THE GRADE AWAY FROM FOUNDATION WALLS
SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST
10 FEET. WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN
10 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED
TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
IMPERVIOUS SURFACES WITHIN 10 FEET OF THE
BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
2 PERCENT AWAY FROM THE BUILDING (IRC SECTION
R401.3)
APPROVED CORROSION-RESISTANT FLASHING SHALL BE
APPLIED SHINGLE-FASHION IN SUCH A MANNER TO
PREVENT ENTRY OF WATER INTO WALL CAVITY OR
PENETRATION OF WATER TO THE BUILDING
STRUCTURAL FRAMING COMPONENTS. THE FLASHING
SHALL EXTEND TO THE SURFACE OF THE EXTERIOR
WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE
FOLLOWING LOCATIONS: 1) EXTERIOR WINDOW AND
DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW
AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE
WATER-RESISTIVE BARRIER FOR SUBSEQUENT
DRAINAGE. 2) AT THE INTERSECTION OF CHIMNEYS OR
OTHER MASONRY CONSTRUCTION WITH FRAME OR
STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES
UNDER STUCCO COPINGS. 3) UNDER AND AT THE ENDS
OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4)
CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5)
WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH
TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME
CONSTRUCTION. 6) AT WALL AND ROOF INTERSECTIONS.
7) AT BUILT-IN GUTTERS (IRC SECTION R703.8)
WEST ELEVATION
DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E
A7.1
Exterior Elevations
Renton, WA 98057
425-271-0082 (office)
425-988-0112 (fax)
www.cwdesigninc.com
P.O. Box 476
Project No:
Drawn By:
Date:
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALLHAVE PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE
CONSTRUCTION PHASE. IT IS THE CONTRACTORS
RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES
TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED.
CW DESIGN, INC MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND/OR
CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH
VARIATION(S) SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH ANY WORK,OR THE CONTRACTOR
SHALL ACCEPT FULL RESPONSIBILTY FOR COST TO
RECTIFY SAME. IN THE EVENT ANY LIABILITY IS
IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU
AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE
FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGS
PRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THE
CONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW
DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS.
Copyright 2019
CW Design, IncC
Status:
Scale:
Sheet Name:
No.Remarks Date
- Submittal Set
WJB
1
2
3
4
5
6
7
8
9 SapphireHomes-TalbotTownhomesLots16-17-18(Bldg'G')Renton,WA19042
Apr 20, 2021
Submittal Set
12/27/20
City Comments 04/20/21
--
--
--
--
--
--
--
--
1/4"=1'-0"
NORTH ELEVATION
EXTERIOR ELEVATION NOTES
CAULK ALL EXTERIOR JOINTS AND PENETRATIONS
BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS,
BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THESE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND. ADDRESS
NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH
A MINIMUM STROKE WIDTH OF 1/2 INCH. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE
BUILDING ADDRESS CANNOT BE VIEWED FROM THE
PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR
MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE
(IRC SECTION R319.1)
SURFACE DRAINAGE SHALL BE DIVERTED TO AN
APPROVED POINT OF COLLECTION SO AS TO NOT
CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS. THE GRADE AWAY FROM FOUNDATION WALLS
SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST
10 FEET. WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN
10 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED
TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
IMPERVIOUS SURFACES WITHIN 10 FEET OF THE
BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
2 PERCENT AWAY FROM THE BUILDING (IRC SECTION
R401.3)
APPROVED CORROSION-RESISTANT FLASHING SHALL BE
APPLIED SHINGLE-FASHION IN SUCH A MANNER TO
PREVENT ENTRY OF WATER INTO WALL CAVITY OR
PENETRATION OF WATER TO THE BUILDING
STRUCTURAL FRAMING COMPONENTS. THE FLASHING
SHALL EXTEND TO THE SURFACE OF THE EXTERIOR
WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE
FOLLOWING LOCATIONS: 1) EXTERIOR WINDOW AND
DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW
AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE
WATER-RESISTIVE BARRIER FOR SUBSEQUENT
DRAINAGE. 2) AT THE INTERSECTION OF CHIMNEYS OR
OTHER MASONRY CONSTRUCTION WITH FRAME OR
STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES
UNDER STUCCO COPINGS. 3) UNDER AND AT THE ENDS
OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4)
CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5)
WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH
TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME
CONSTRUCTION. 6) AT WALL AND ROOF INTERSECTIONS.
7) AT BUILT-IN GUTTERS (IRC SECTION R703.8)
EAST ELEVATION