Loading...
HomeMy WebLinkAboutEx05_Floor_PlansRenton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots13-14-15(Bldg'F')Renton,WA19041 Apr 27, 2021 Submittal Set 12/27/20 City Comments 04/27/21 -- -- -- -- -- -- -- -- 1/4"=1'-0" A3.0 Lower Floor Plan UNIT 'A' - LOWER FLOOR PLAN 9'-1 1/8" LOWER FLR PLATE HEIGHT (TYP UNO) 8'-0" WDW HDR HT ABV LOWER FLR SOG (TYP UNO) EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE-TREATED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). PROVIDE MINIMUM 1/2" GWB ON GARAGE SIDE OF WALLS COMMON TO HOUSE AND WALLS THAT SUPPORT CEILINGS COMMON TO HOUSE. USE MINIMUM 5/8" TYPE 'X' GWB ON GARAGE CEILING COMMON TO HOUSE. INSTALL 1/2" GWB AT ALL USEABLE AREAS UNDER STAIRS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. FLOOR PLAN NOTES SYMBOL LEGEND HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP N 4'8'2'0' 1'3'6' SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS UNIT 'B' - LOWER FLOOR PLAN UNIT 'C' - LOWER FLOOR PLAN B21000302 EXHIBIT 5 RECEIVED Clark Close 07/16/2021 PLANNING DIVISION DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E Renton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots13-14-15(Bldg'F')Renton,WA19041 Apr 27, 2021 Submittal Set 12/27/20 City Comments 04/27/21 -- -- -- -- -- -- -- -- 1/4"=1'-0" A4.0 Main Floor Plan UNIT 'A' - MAIN FLOOR PLAN 2015 WSEC NOTES THE DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. (WSEC R401.3) AIR LEAKAGE SHALL NOT EXCEED 5 AIR CHANGES/HOUR, AND SHALL BE TESTED PER WSEC R402.4.1.2. PROVIDE A WRITTEN REPORT OF THE TEST RESULTS, SIGNED BY THE TESTING PARTY, PRIOR TO APPROVED FINAL INSPECTION. (WSEC R402.4.1.2) PROVIDE A PROGRAMMABLE THERMOSTAT FOR THE PRIMARY SPACE CONDITIONING SYSTEM WITHIN EACH DWELLING UNIT. (WSEC R403.1.1) DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. (WSEC R403.2.2) A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. (WSEC R404.1) N 4'8'2'0' 1'3'6' EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE-TREATED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). PROVIDE MINIMUM 1/2" GWB ON GARAGE SIDE OF WALLS COMMON TO HOUSE AND WALLS THAT SUPPORT CEILINGS COMMON TO HOUSE. USE MINIMUM 5/8" TYPE 'X' GWB ON GARAGE CEILING COMMON TO HOUSE. INSTALL 1/2" GWB AT ALL USEABLE AREAS UNDER STAIRS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. DISHWASHER SHALL BE INSTALLED WITH AIR GAP PER UPC SEC 807.4. RANGE HOOD DUCT SHALL BE METAL WITH SMOOTH INNER WALLS, SHALL BE AIR TIGHT, AND SHALL EXHAUST TO THE OUTSIDE PER IMC SEC 505 FLOOR PLAN NOTES SYMBOL LEGEND 9'-1 1/8" MAIN FLOOR PLATE HEIGHT (TYP UNO) 8'-0" WDW HDR HT ABV MAIN FLR (TYP UNO) HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP LOWER FLOOR MAIN FLOOR UPPER FLOOR TOTAL HEATED AREA GARAGE CVR'D PORCH CVR'D DECK CVR'D PATIO SQUARE FOOTAGE SUMMARY UNIT A UNIT B UNIT C 527 906 924 2,357 371 28 54 - 539 950 980 2,469 431 27 56 - UNIT 'B' - MAIN FLOOR PLAN UNIT 'C' - MAIN FLOOR PLAN 464 877 923 2,264 420 45 54 -B21000302 DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E Renton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots13-14-15(Bldg'F')Renton,WA19041 Dec 27, 2020 Submittal Set 12/27/20 -- -- -- -- -- -- -- -- -- 1/4"=1'-0" A5.0 Upper Floor Plan UNIT 'A' - UPPER FLOOR PLAN N 4'8'2'0' 1'3'6' 8'-1 1/8" UPPER FLOOR PLATE HEIGHT (TYP UNO) 7'-0" WDW HDR HT ABV UPPER FLR (TYP UNO) EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. FLOOR PLAN NOTES SYMBOL LEGEND HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP UNIT 'C' - UPPER FLOOR PLAN UNIT 'B' - UPPER FLOOR PLAN B21000302 DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E Renton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots16-17-18(Bldg'G')Renton,WA19042 Apr 20, 2021 Submittal Set 12/27/20 City Comments 04/20/21 -- -- -- -- -- -- -- -- 1/4"=1'-0" A3.0 Lower Floor Plan UNIT 'A' - LOWER FLOOR PLAN 9'-1 1/8" LOWER FLR PLATE HEIGHT (TYP UNO) 8'-0" WDW HDR HT ABV LOWER FLR SOG (TYP UNO) EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE-TREATED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). PROVIDE MINIMUM 1/2" GWB ON GARAGE SIDE OF WALLS COMMON TO HOUSE AND WALLS THAT SUPPORT CEILINGS COMMON TO HOUSE. USE MINIMUM 5/8" TYPE 'X' GWB ON GARAGE CEILING COMMON TO HOUSE. INSTALL 1/2" GWB AT ALL USEABLE AREAS UNDER STAIRS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. FLOOR PLAN NOTES SYMBOL LEGEND HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP N 4'8'2'0' 1'3'6' SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS UNIT 'B' - LOWER FLOOR PLAN UNIT 'C' - LOWER FLOOR PLAN B20005991 DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E Renton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots16-17-18(Bldg'G')Renton,WA19042 Apr 20, 2021 Submittal Set 12/27/20 City Comments 04/20/21 -- -- -- -- -- -- -- -- 1/4"=1'-0" A4.0 Main Floor Plan UNIT 'A' - MAIN FLOOR PLAN 2015 WSEC NOTES THE DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. (WSEC R401.3) AIR LEAKAGE SHALL NOT EXCEED 5 AIR CHANGES/HOUR, AND SHALL BE TESTED PER WSEC R402.4.1.2. PROVIDE A WRITTEN REPORT OF THE TEST RESULTS, SIGNED BY THE TESTING PARTY, PRIOR TO APPROVED FINAL INSPECTION. (WSEC R402.4.1.2) PROVIDE A PROGRAMMABLE THERMOSTAT FOR THE PRIMARY SPACE CONDITIONING SYSTEM WITHIN EACH DWELLING UNIT. (WSEC R403.1.1) DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. (WSEC R403.2.2) A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. (WSEC R404.1) N 4'8'2'0' 1'3'6' 9'-1 1/8" MAIN FLOOR PLATE HEIGHT (TYP UNO) 8'-0" WDW HDR HT ABV MAIN FLR (TYP UNO) EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE-TREATED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). PROVIDE MINIMUM 1/2" GWB ON GARAGE SIDE OF WALLS COMMON TO HOUSE AND WALLS THAT SUPPORT CEILINGS COMMON TO HOUSE. USE MINIMUM 5/8" TYPE 'X' GWB ON GARAGE CEILING COMMON TO HOUSE. INSTALL 1/2" GWB AT ALL USEABLE AREAS UNDER STAIRS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. DISHWASHER SHALL BE INSTALLED WITH AIR GAP PER UPC SEC 807.4 RANGE HOOD DUCT SHALL BE METAL WITH SMOOTH INNER WALLS, SHALL BE AIR TIGHT, AND SHALL EXHAUST TO THE OUTSIDE PER IMC SEC 505 FLOOR PLAN NOTES SYMBOL LEGEND HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP LOWER FLOOR MAIN FLOOR UPPER FLOOR TOTAL HEATED AREA GARAGE CVR'D PORCH CVR'D DECK CVR'D PATIO SQUARE FOOTAGE SUMMARY UNIT A UNIT B UNIT C 527 906 924 2,357 371 28 54 - 539 950 980 2,469 431 27 56 - UNIT 'B' - MAIN FLOOR PLAN UNIT 'C' - MAIN FLOOR PLAN 527 906 924 2,357 371 28 54 -B20005991 DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E Renton, WA 98057 425-271-0082 (office) 425-988-0112 (fax) www.cwdesigninc.com P.O. Box 476 Project No: Drawn By: Date: WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS FOR THIS PROJECT, PRIOR TO THE CONSTRUCTION PHASE. IT IS THE CONTRACTORS RESPONSIBILITY TO REPORT ANY/ALL DISCREPANCIES TO THE DESIGNER AT THE TIME THEY ARE IDENTIFIED. CW DESIGN, INC MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. ANY SUCH VARIATION(S) SHALL BE RESOLVED PRIOR TO PROCEEDING WITH ANY WORK,OR THE CONTRACTORSHALL ACCEPT FULL RESPONSIBILTY FOR COST TORECTIFY SAME. IN THE EVENT ANY LIABILITY IS IMPOSED ON CW DESIGN, INC, OUR LIABILITY TO YOU AND/OR ANY THIRD PARTY SHALL NOT EXCEED THE FEE PAID TO CW DESIGN, INC, FOR THE DRAWINGSPRODUCED FOR THIS PROJECT. ANY UNAUTHORIZEDALTERATIONS OF THESE DRAWINGS BY THECONTRACTOR AND/OR THIRD PARTY SHALL HOLD CW DESIGN, INC. HARMLESS FROM ANY AND ALL CLAIMS. Copyright 2019 CW Design, IncC Status: Scale: Sheet Name: No.Remarks Date - Submittal Set WJB 1 2 3 4 5 6 7 8 9 SapphireHomes-TalbotTownhomesLots16-17-18(Bldg'G')Renton,WA19042 Dec 27, 2020 Submittal Set 12/27/20 -- -- -- -- -- -- -- -- -- 1/4"=1'-0" A5.0 Upper Floor Plan UNIT 'A' - UPPER FLOOR PLAN N 4'8'2'0' 1'3'6' 8'-1 1/8" UPPER FLOOR PLATE HEIGHT (TYP UNO) 7'-0" WDW HDR HT ABV UPPER FLR (TYP UNO) EXTERIOR WALL CONSTRUCTION (TYP UNO): -SIDING PER ELEVATIONS -VAPOR BARRIER -WALL SHEATHING PER PLAN -2x6 HF#2 STUDS AT 16" OC -R-21 INSULATION -1/2" GWB INTERIOR WALL CONSTRUCTION (TYP UNO): -1/2" GWB AT EACH SIDE -2x4 STUDS AT 16" OC INSTALL TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. INSTALL FIRE BLOCKING AT ALL WALLS OVER 10'-0" IN HEIGHT, STAIRS AND AT ALL PLUMBING AND MECHANICAL PENETRATIONS (TYP UNO). FIREBLOCK BETWEEN STUDS AT ALL SHOWERS STALLS, WALLS TO BE WATERPROOF TO A MIN OF +72" ABOVE THE FLOOR . INSTALL FURRING AS NEEDED TO CONCEAL MECHANICAL DUCTWORK, ELECTRICAL WIRING OR PLUMBING PIPES. INSTALL 2x BLOCKING (FULL STUD DEPTH) FOR ATTACHMENT OF UPPER CABINETS (TYP UNO). INSTALL 1/2" GWB AT ALL USEABLE AREAS UNDER STAIRS (TYP UNO). ALL DOORS AND WINDOWS ARE MEASURED TO THE CENTER (UNO). ALL DOORS THAT ARE NOT DIMENSIONED, ARE 4" FROM CORNERS. FLOOR PLAN NOTES SYMBOL LEGEND HEAT REGISTER. VERIFY LOCATIONS WITH MECH CONTRACTOR SD EFVTOS (EXHAUST FAN, VENT TO OUTSIDE) MINIMUM 80 CFM SDCM SYMBOL DESCRIPTION DOWNSPOUT FROM ROOFDS 110v SMOKE ALARM, HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP 110v SMOKE ALARM/CARBON MONOXIDE DETECTOR (COMBO UNIT), HARD-WIRED & INTERCONNECTED WITH BATTERY BACKUP UNIT 'C' - UPPER FLOOR PLAN UNIT 'B' - UPPER FLOOR PLAN B20005991RECEIVED Clark Close 07/16/2021 PLANNING DIVISION DocuSign Envelope ID: 573794A8-A312-4F54-AA97-AAAAB681975E