HomeMy WebLinkAboutR-411306I—
Q
n
ry
IN-
0
_
U)
z
2
U
0
0
z
\lJ
I—
W
W
r2
V
N
0
(n
n
N
00
C
O
0
0
Q
U
CD
n
O
U�
C
6
U
O
z
cn
r�
w
Un
0
Ln
N
co
0
J
I=
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
OF*O 0,Sok
R=2E MIN.
INSTALL DRIVEWAY CULVERT
IF THERE IS A ROADSIDE
DITCH PRESENT, AS PER CITY '
ROAD STANDARDS
100' MIN.
4"-8- QUARRY $PALLS
GE07EXTILE
12" MIN. THICKNESS
1. DRIVEWAYS SHALL BE PAVED TO
THE EDGE OF THE RIGHT-OF-WAY
PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO
AVOID DAMAGING OF THE
ROADWAY.
2. IT IS RECOMMENDED THAT THE
ENTRANCE BE. CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
15' MIN.
PROVIDE FULL WIDTH OF
INGR ESSrEGRE SS AREA
NOTES:
1. CONDITIONOFUSE
1.1, CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER
PAVED AREAS WITHIN 1,001D FEET OF THE SITE
1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION
ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHAVIDTH TO PROVIDE VEHICLE ACCESSIPARKING. BASED ON LOT SIZEICONFIGURATION
R DESIGN AND INSTALLATION SPECIFICATIONS
2-1. A SEPARATION GEOTE)MLE SHALL BE PLACED UNDER THE SPALLS 70 PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE
SHALL MEET THE FOLLOWING STANDARDS!
GRAB TENSILE STRENGTH (ASTM D4632)
200 LSS. MIN.
GRAB TENSILE ELONGATION (ASTM C46323
30%MAT(. (WOVEN)
CBR PUNCTURE STRENGTH (ASTM D6241)
445 LBS. MIN.
ADS (ASTM D4751)
20-05 (U.S. STANDARD SIEVE SIZE)
2.2, DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH
LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED.
2.3. HOG FUEL (WOOD BASED MULCHy MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS,
HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REOUIRE THE USE OF QUARRY SPALLS
IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL 1S BEING CARRIED ONTO PAVEMENT.
2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.5. WHENEVER POSSIBLE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE
EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF
SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL
WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE
REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AN
THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED THE SEDIMENT WOULD THEN BE
WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND
CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND ENO UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL
TRAFFIC.
UNLESS OT H ERWISf NOTED, DRAWING IS NOT TO SCALE INTS)
STD. PLAN - 215.10
aR PUBLIC WORKS rPR°>ED'
DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 I
wWr wo..+.e•.iw DATE
j�G�J LLCM
Land Planning e Civil Engineering
0
N 5130 South 166th Lane
SeaTac, WA 98188
T (206) 229-6422
U
0
:45 P
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
TOE IN SHEETING IN
4" x 4" MIN. TRENCH
PROVIDE ENERGY DISSIPATION
AT TOE IF EROSION IS LIKELY —
SANDBAG (TYP. )
NOTES-
1. CONDITIONS OF USE
1.1. PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS.
12. PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES.
1.3. CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY -SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH.
CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS.
1.4. THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND
UNSTABLE SLOPES.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2-1. PLASTIC SHEETING SHOULD HAVE A MINIMVM THICKNESS OF 0.06 MILLIMETERS.
2.2. IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE
OF THE SLOPE IN ORDER 70 REDUCE THE VELOCITY OF RUNOFF-
2.3. TIRES, SAND BAGS, OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC.
2.4. SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12INCHES AND BE WEIGHTED OR TAPED.
3, MAINTENANCE STANDARDS
3-1. TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED.
3.2. IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED.
3-3. WHEN THE PLASTIC IS NO LONGER NEEDED, IT SHALL BE COMPLETELY REMOVED -
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE [NTS)
STD, PLAN - 213.30
AOM� v - PUBLIC WORKS PR0
Pl' DEPARTMENT PLASTIC COVERING GAZ 9/28/2018 I
v.bkww,am„",n.ia DATE
JOB NO.
M8325
NO.
REVISION
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
:45
BY I DATE I APPR
JOINTS IN FILTER FABRIC SHALL BE SPLICED AT
POSTS- USE STAPLES, WIRE RINGS. OR
EQUIVALENT TO ATTACH FABRIC TO POSTS
2712' 14 GAUGE WIRE. OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
2' MIN.
FILTER FABRIC
�6 MAX.
POST SPACING MAY BE INCREASED ^ 4-x4" MIN. TRENCH
LJ TO B' IF WIRE BACKING IS USED 1 I I I�
BACKF ILL TRENCH WITH NATIVE SOILLi
OR 314" TO I.112" WASHED GRAVEL
2"x4' WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.)
NOTES:
1. CONDITIONS OF USE
1,1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1,2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED
FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTI LE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE.
ADS [ASTM D4751]
3D-100 SIEVE SIZE (D.60-0.15mmy FOR SILT FILM
50.700 SIEVE SI2E (D.30-0.15m ) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D4491)
0.02 SECT MINIMUM
GRAB TENSILE STRENGTH [ASTM 04632]
1 80 LBS. MIN. FOR EXTRA STRENGTH FABRIC
10O LBS- MIN- FOR STANDARD STRENGTH FABRIC
GRAB TENSILE ELONGATION (ASTM D4632)
30% MAX. (WOVEN)
ULTRAVIOLET RESISTANCE (ASTM D4355)
70% MIN.
22. STANDARD STRENGTH FABRIC REOU IRE S WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED
FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V
2.4. IF ATYPICAL SILT FENCE IS USEDTHE STANDARD 4'X4' TRENCH MAYBE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND
SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE.
2.5, FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3-3- IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING
CHANNE LIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE TINE TRAPPED SEDIMENT-
3-4, SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
UNLESS OTHERWISE NOTED- DRAWING 1S NOT TO SCALE INTS)
STD. PLAN - 214.00
w PUBLIC WORKS SILT FENCE PR 9/28/2018 1
DEPARTMENT GAZ
m„ CATF
DESIGNED:
H. H. PHAN
DRAWN:
H. H. PHAN
CHECKED:
APPROVED:
SCALE:
NONE
ONEINCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
:45
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
MAX-
Lt/_
S"DRAINAGE GRATE TR[M
GRATE FRAME _
C_ OVERFLOW BYPASS
1
BELOW INLET GRATE DEVICE
SEDIMENT AND DEBRIS gy
f ILTERED
WATER
SECTION VIEW
DRAINAGE GRATE
(RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM
OVERFLOW BYPASS (TYP.)
BELOW INLET GRATE DEVICE
ISOMETRIC VIEW
NOTES:
1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLET$ DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR
CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP-
2- INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM.
3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE.
4. SIZE THE BELOW INLET GRATE DEVICE IBIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE-
S, THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS).
6, THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL.
7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15).
S. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THRO OF THE AVAILABLE
STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY,
UNLESS 0THERWI5E NOTED, DRAWING IS NOT TO SCALE jNTS)
STD. PLAN • 116,30
PUBLIcwaRKs '�lCATCH BASIN INSERT A ED 9/28/2018 I
` DEPARTMENT GAZ
w.rwe.nam+...rw DATE
Know what's below.
Call before you dig.
CITY OF
RENTON
Planning/Building/Public Works Dept.
:45 A
R-411306
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
jchavez 12/11 /2020
NGOCHAN SHORT PLAT
10814 SE 173RD STREET
RENTON, WA 98055
STANDARD DETAILS - 1
DATE:
10-10-202
PAGE:
DT2
• f
co
C)
C)
O
,
LJ
Q
J
ry
0
vJ
z
Q
U
f0
V
z